• Title/Summary/Keyword: earthquake protection

Search Result 125, Processing Time 0.023 seconds

Analysis of correlation between groundwater level decline and wetland area decrease

  • Amos Agossou;Jae-Boem Lee;Bo-Gwon Jung;Jeong-Seok Yang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.374-374
    • /
    • 2023
  • Groundwater is the main source of water on which relies many countries in case of emergency, this is the case of Japan in 2011 after the great Sendai Earthquake. This important resource is found to be heavily influenced by human induced factors such as wetland area reduction. For groundwater sustainable management in perfect cohesion with wetland it is important to understand the relationship between both resources. Wetlands have a strong interaction with both groundwater and surface water, influencing catchment hydrology and water quality. Quantifying groundwater-wetland interactions can help better identify locations for wetlands restoration and/or protection. This study uses observation data from piezometers and wetland to study the qualitative and quantitative aspects of the correlation. Groundwater level, wetland area, chemical, organic and inorganic contaminants are the important parameters used. the results proved that few contaminants in the wetland are found in groundwater and in general the wetland quality does not affect that much groundwater quality. The strong linear relationship found between wetland water level and nearest groundwater level proved that, in term of quantity, groundwater and wetland are strongly correlated. While wetland becoming dry, groundwater level has dropped in the region about 0.52m. The area of wetland was found to be lightly correlated with groundwater level, proving that wetlands dry has contributed to groundwater level declining. This study has showed that whilst rainfall variability contributed to the decline and loss of wetlands, the impacts from landuse changes and groundwater extraction were likely to be significant contributors to the observed losses.

  • PDF

A Study on Base Isolation Performance and Phenomenological Model of E-Shape Steel Hysteretic Damper (E-Shape 강재이력댐퍼의 수치모델과 기초격리구조물의 지진응답)

  • Hwang, Inho;Ju, Minkwan;Sim, Jongsung;Lee, Jong Seh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.685-690
    • /
    • 2008
  • Recently, as large structures become lighter and more flexible, the necessity of structural control for reducing excessive displacement and acceleration due to seismic excitation is increased. As a means to minimize seismic damages, various base isolation systems are adopted or considered for adoption. In this study, a base isolation system using hysteretic damper is shown to effectively protect structures against earthquakes. A mechanical model is determined that can effectively portray the behavior of a typical E-shape device. Comparison with experimental results for a hysteretic damper indicates that the model is accurate over a wide range of operating conditions and adequate for analysis. The seismic performance of hysteretic dampers are studied and compared with the conventional systems as a base isolation system. A five-story building is modeled and the seismic performance of the systems subjected to three different earthquake is compared. The results show that the hysteretic damper system can provide superior protection than the other systems for a wide range of ground motions.

A Study on the Establishment of Disaster Prevention Plans for Nuclear Facilities considering Complex Disasters (복합재난을 고려한 원자력시설 사고대비 방재계획 수립방안)

  • Jihoon Shin;Younwon Park;Seunghyeon Kim;Minho Cha;Minsang Ryu
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.4
    • /
    • pp.85-99
    • /
    • 2023
  • By the social advancement, radiological disaster prevention planning is getting important considering complex disasters as in the Fukushima radiological disaster occurred by a chain of natural disasters. However, it has yet to be suggested the specific prevention plans for the complex disasters in the field of national radiological disaster prevention. This study aims to analyze the types of complex disasters in order to select the ones that are relatively more likely to occur in the domestic environment. It is also to analyze the impact on the radiological disaster prevention by searching damage spread of the classified natural disasters. We provides the necessary criterial for establishing disaster prevention plans through the scenarios for radiological emergency responses based on complex disasters. it is thought that these criteria can help prepare for the worst case scenario and implement effective resident protection.

The use of SMA wire dampers to enhance the seismic performance of two historical Islamic minarets

  • El-Attar, Adel;Saleh, Ahmed;El-Habbal, Islam;Zaghw, Abdel Hamid;Osman, Ashraf
    • Smart Structures and Systems
    • /
    • v.4 no.2
    • /
    • pp.221-232
    • /
    • 2008
  • This paper represents the final results of a research program sponsored by the European Commission through project WIND-CHIME ($\underline{W}$ide Range Non-$\underline{IN}$trusive $\underline{D}$evices toward $\underline{C}$onservation of $\underline{HI}$storical Monuments in the $\underline{ME}$diterranean Area), in which the possibility of using advanced seismic protection technologies to preserve historical monuments in the Mediterranean area is investigated. In the current research, the dynamic characteristics of two outstanding Mamluk-Style minarets, which similar minarets were reported to experience extensive damage during Dahshur 1992 earthquake, are investigated. The first minaret is the Qusun minaret (1337 A.D, 736 Hijri Date (H.D)) located in El-Suyuti cemetery on the southern side of the Salah El-Din citadel. The minaret is currently separated from the surrounding building and is directly resting on the ground (no vaults underneath). The total height of the minaret is 40.28 meters with a base rectangular shaft of about 5.42 ${\times}$ 5.20 m. The second minaret is the southern minaret of Al-Sultaniya (1340 A.D, 739 H.D). It is located about 30.0 meters from Qusun minaret, and it is now standing alone but it seems that it used to be attached to a huge unidentified structure. The style of the minaret and its size attribute it to the first half of the fourteenth century. The minaret total height is 36.69 meters and has a 4.48 ${\times}$ 4.48 m rectangular base. Field investigations were conducted to obtain: (a) geometrical description of the minarets, (b) material properties of the minarets' stones, and (c) soil conditions at the minarets' location. Ambient vibration tests were performed to determine the modal parameters of the minarets such as natural frequencies and mode shapes. A $1/16^{th}$ scale model of Qusun minaret was constructed at Cairo University Concrete Research Laboratory and tested under free vibration with and without SMA wire dampers. The contribution of SMA wire dampers to the structural damping coefficient was evaluated under different vertical loads and vibration amplitudes. Experimental results were used along with the field investigation data to develop a realistic 3-D finite element model that can be used for seismic risk evaluation of the minarets. Examining the updated finite element models under different seismic excitations indicated the vulnerability of such structures to earthquakes with medium to high a/v ratio. The use of SMA wire dampers was found feasible for reducing the seismic risk for this type of structures.

Semi-active storey isolation system employing MRE isolator with parameter identification based on NSGA-II with DCD

  • Gu, Xiaoyu;Yu, Yang;Li, Jianchun;Li, Yancheng;Alamdari, Mehrisadat Makki
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.1101-1121
    • /
    • 2016
  • Base isolation, one of the popular seismic protection approaches proven to be effective in practical applications, has been widely applied worldwide during the past few decades. As the techniques mature, it has been recognised that, the biggest issue faced in base isolation technique is the challenge of great base displacement demand, which leads to the potential of overturning of the structure, instability and permanent damage of the isolators. Meanwhile, drain, ventilation and regular maintenance at the base isolation level are quite difficult and rather time- and fund- consuming, especially in the highly populated areas. To address these challenges, a number of efforts have been dedicated to propose new isolation systems, including segmental building, additional storey isolation (ASI) and mid-storey isolation system, etc. However, such techniques have their own flaws, among which whipping effect is the most obvious one. Moreover, due to their inherent passive nature, all these techniques, including traditional base isolation system, show incapability to cope with the unpredictable and diverse nature of earthquakes. The solution for the aforementioned challenge is to develop an innovative vibration isolation system to realise variable structural stiffness to maximise the adaptability and controllability of the system. Recently, advances on the development of an adaptive magneto-rheological elastomer (MRE) vibration isolator has enlightened the development of adaptive base isolation systems due to its ability to alter stiffness by changing applied electrical current. In this study, an innovative semi-active storey isolation system inserting such novel MRE isolators between each floor is proposed. The stiffness of each level in the proposed isolation system can thus be changed according to characteristics of the MRE isolators. Non-dominated sorting genetic algorithm type II (NSGA-II) with dynamic crowding distance (DCD) is utilised for the optimisation of the parameters at isolation level in the system. Extensive comparative simulation studies have been conducted using 5-storey benchmark model to evaluate the performance of the proposed isolation system under different earthquake excitations. Simulation results compare the seismic responses of bare building, building with passive controlled MRE base isolation system, building with passive-controlled MRE storey isolation system and building with optimised storey isolation system.