• 제목/요약/키워드: earth-fill dam

검색결과 38건 처리시간 0.026초

필댐 하류사면 자생식물의 습생지수 결정 (Determination of Hydrophyte Index of Native Plant on the Downstream Slope of Earth Fill Dam)

  • 김현수;류범희;박승기
    • 한국농공학회논문집
    • /
    • 제61권1호
    • /
    • pp.131-144
    • /
    • 2019
  • The purpose of study was to determine the hygrophyte index of each plant(HIP) considering the moisture environment condition (MEC) of the native plants on the downstream slope of the fill dam and evaluate its applicability which to develop a method to search for leaks and saturated zones of the fill dam for status evaluation of precision safety diagnosis. The HIP was weighted average and consisted of 19 ranks. The weighted average was calculated according to the following three procedures: First, the linear assumption was made according to the actual habitat environmental conditions, the second one was weighted to 10% of the optimal habitat condition, and finally the average value of the distribution range values. The Hygrophyte index of vegetation at each plot (HIV) was obtained from the Sinheung reservoir (Yesan-gun, Chungcheongnam-do) using the results of vegetation survey of the Sinheung reservoir with precision safety diagnosis and suggested the use of the hygrophyte index of the cultivated vegetation. The average HIP range of plant species that emerged in 50 survey sites on the downstream slope of the Sinheung reservoir is 2.99 to 3.56. The coefficient of variation showed a large difference depending on the appearance of the leakage indicator plant(LIP) species. The range of HIV is 2.80 to 4.26, the mean value is 3.37, standard deviation is 0.37 and the coefficient of variation is 9.7%. As a result, the value of the coefficient of variation showed a large difference depending on the appearance of the plant species.

필댐의 안정성 해석 연구 (II) (A STUDY ON THE SAFETY ANALYSIS OF ROCK FILL DAM (2))

  • 손호웅;이대근
    • 지구물리
    • /
    • 제6권3호
    • /
    • pp.189-207
    • /
    • 2003
  • 경북 청도군 소재 운문댐의 안전진단을 목적으로 지반조사 및 계측자료의 분석이 수행되었다 특히 운문댐은 1998년에 차례에 걸쳐 댐의 정상부에 함몰현상이 발생되었으며 이러한 함몰현상이 대해 많은 조사가 이루어졌으며 이에 따라 CGS보강공법을 2000년에 시행하였다 댐의 함몰현상의 메카니즘에 대해 많은 의견이 있으나 누수에 의한 내부침식이 가장 유력하다 필댐에 있어서의 과대누수는 댐의 안정성의 평가하는데 가장 중요한 변수로 작용 하므로 토질시험 계측자료 및 시추자료를 통한 댐체의 누수 및 거동분석을 수행하였다 자료들을 종합해 본 결과 부실시공 댐의 응력전이 수압할렬의 가능성 누수 취약대 등과 같은 댐의 거동에 대한 여러 가지 정보를 얻을 수 있었다 또한 토질시험에서 코아재료의 적합성에 문제가 있었음을 발견하였다 댐 제체에서도 연약대가 발견되었 으며 여수로 근접한 부분에서 누수의 가능성이 높은 것으로 나타났다 거동분석에서는 댐 코아의 수압할렬이나 응력전이에 의한 손상이나 유로의 가능성도 배제할 수 없었다

  • PDF

Seismic fragility analysis of a cemented Sand-gravel dam considering two failure modes

  • Mahmoodi, Khadije;Noorzad, Ali;Mahboubi, Ahmad
    • Computers and Concrete
    • /
    • 제26권6호
    • /
    • pp.483-495
    • /
    • 2020
  • Dams are vital infrastructures that are expected to maintain their stability during seismic excitations. Accordingly, cemented material dams are an emerging type, which are being increasingly used around the world owing to benefiting from advantages of both earth-fill and concrete gravity dams, which should be designed safely when subjected to strong ground motion. In the present paper, the seismic performance of a cemented sand and gravel (CSG) dam is assessed using incremental dynamic analysis (IDA) method by accounting for two failure modes of tension cracking and base joint sliding considering the dam-reservoir-foundation interactions. To take the seismic uncertainties into account, the dam is analyzed under a suite of ground motion records and then, the effect of friction angle for base sliding as well as deformability of the foundation are investigated on the response of dam. To carry out the analyses, the Cindere dam in Turkey is selected as a case study, and various limit states corresponding to seismic performance levels of the dam are determined aiming to estimate the seismic fragilities. Based on the results, sliding of the Cindere dam could be serious under the maximum credible earthquake (MCE). Besides, dam faces are mostly to be cracked under such level of intensity. Moreover, the results indicate that as friction angle increases, probability of sliding between dam and foundation is reduced whereas, increases tensile cracking. Lastly, it is observed that foundation stiffening increases the probability of dam sliding but, reduces the tensile damage in the dam body.

흙댐의 누수구역 판별을 위한 물리탐사와 온도 모니터링 자료의 해석 (An Analysis of Geophysical and Temperature Monitoring Data for Leakage Detection of Earth Dam)

  • 오석훈;서백수;김중열
    • 한국지구과학회지
    • /
    • 제31권6호
    • /
    • pp.563-572
    • /
    • 2010
  • 흙댐에서의 누수 구역을 판별하기 위해 다채널 연속 온도 모니터링을 수행하고 이를 검증하기 위해 전기비저항 물리탐사를 함께 수행하였다. 일반적으로 댐이나 사면과 같은 인공구조물의 내부는 시간과 위치에 따라 상이한 온도 분포를 갖는 것으로 여겨진다. 이와 같은 분포는 구조물의 안전성을 판단하는 데 매우 중요한 기본 자료로 이용될 수 있으며, 특히 댐 구조물의 경우 과도 침투수나 누수에 의한 위험 대역을 파악할 수 있는 기술로 이용될 수 있다. 그러나 기존의 온도 측정 방식은 대형 구조물의 온도를 연속적으로 동시에 측정할 수 없는 단점을 가지고 있다. 본 연구에서는 이를 극복한 새로운 온도 모니터링 장비를 이용하여 댐의 상부 및 하부에 걸쳐, 여러 지점에서 동시에 온도 분포를 측정하였으며, 실내 시험을 통해 누수 대역이 온도 분포의 이상을 충분히 반영하고 있음을 관측하였다. 또한 대상 댐의 전 구역에 걸쳐 전기비저항 조사를 수행한 결과와 온도 모니터링 자료를 비교 분석하여 누수구역의 판별력을 높일 수 있는 방법을 제시하고자 하였다.

수중구조물을 위한 가물막이 설계 및 시공사례에 대한 연구 (A Case Study on Design and Construction of Cofferdam for Hydraulic Structure)

  • 조주환;신동훈;정승태;우상윤;남용
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.124-143
    • /
    • 2010
  • Cofferdam is a temporary levee or dam structure built by using sheet pile or earth materials to prevent water infiltration during construction work of bridge, dam, harbour dock, or hydraulic structures in the river. In this regard, it is required to secure cutoff ability for dry work and workability for rapid installation and removal of the temporary dam or levee structures. In this paper, case studies for design and construction of cofferdam were performed, and water diversion method was briefed with some examples of cofferdam type as well. For the case study details of design and construction were reviewed based on cofferdams under construction related to 16 submerged weirs of "The 4-river restoration project" and dam type cofferdam respectively. From the review, it was known that the method for changing the water flow is selected based on the data from geological and geo-hydraulic site investigation in order to mitigate environmental effects by making sure if the design cross-sectional area of flow and maximum working days are sufficiently guaranteed. Finally, the primary findings and main conclusion derived are summarized that determination of applicable type of cofferdam should be checked by case study and meet design requirements such as water inflow control, constructability.

  • PDF

P파 초동주시와 표면파 분산곡선 역산을 통한 흙댐의 이상대 탐지 (Detection of anomalous features in an earthen dam using inversion of P-wave first-arrival times and surface-wave dispersion curves)

  • 김기영;전광민;홍명호;박영규
    • 지구물리와물리탐사
    • /
    • 제14권1호
    • /
    • pp.42-49
    • /
    • 2011
  • 대룡 흙댐익 누수경로를 포함한 이상대 탐지를 위하여, 댐 정상부의 250 m 측선을 따라 P 파와 레일리파를 기록하였다. 5 kg 해머를 이용하여 인공적으로 소규모 지진파를 발생시켰으며, 3m 간격으로 설치한 4.5 Hz 수직지오폰 24개로 탐지하였다. 이 저수지댐과 하부 기반암의 P파 속도와 S파 겉보기속도를 초동주시와 레일리파 분산곡선 역산으로 각각 구하였다. 겉보기 동포아송비가 0.46에 달하는 높은 값들이 복통이 위치한 북서쪽 끝부분의 댐 기저와 누수저지를 위해 과거 여러 차례 그라우팅 작업을 실시한 측선 남서쪽 끝 부분의 점토코아 내에서 탐지되었다. 상부 점토코아의 높은 포아송비를 갖는 이 이상대는, 조사 후 실시한 그라우팅 작업 시 그라우트 물질이 유출된 부분에 해당한다. P파 토모그래피와 레일리파 분산곡선 역산을 함께 사용하면 흙댐의 잠재적 누수경로 및 기존 그라우팅 위치를 매우 효과적으로 탐지할 수 있다.

노후 코어형 필댐의 잠재 위해성 유형 분류 (Potential Hazard Classification of Aged Cored Fill Dams)

  • 박동순;오제헌
    • 지질공학
    • /
    • 제26권2호
    • /
    • pp.207-221
    • /
    • 2016
  • 최근 국내 필댐 및 저수지의 노후화가 급속도로 진행되고 있으며, 이에 따른 제체의 손상이나 붕괴사고가 잇따르고 있다. 그러나 필댐의 핵심적인 차수기능을 담당하는 코어층에 대한 열화와 잠재 위해성 분류에 대한 연구는 거의 미진한 실정이다. 본 연구에서는 노후화가 진행 중인 13개 기존 코어형 필댐에 대해(준공 후 경과년수 9-52년, 댐 높이 22-67 m), 무수보링에 의한 코어층 시추 지반조사와 표준관입시험, 2D 및 3D 전기비저항탐사, 물성·역학시험을 수행하여 공학적 기반의 잠재적 위해성 유형을 국내 최초로 분류, 제시하였다. 중심코어층에 대한 무수보링 시추 지반조사 결과, 코어재 잠재 위해성 유형을 국부적 포화대, 신속한 공내수 유입, 조립질 혼재 코어재, 상대적 저 강성의 네 종류로 분류하였다. 코어형 필댐의 잠재 위해성 유형 중국부적 포화대 유형은 코어존 내 유로의 성장 및 발달에 의한 내적침식의 가능성이 존재하므로 가장 위험한 위해성으로 분류 되었으며, 코어재의 열화 등급에 따라 적절한 차수능 회복을 위한 보수보강이 필요한 것으로 판단되었다. 그 외 세 가지 위해성 유형은 즉각적인 조치보다는 지속적인 모니터링과 정기 검사의 강화가 필요할 것으로 검토되었다. 본 연구대상 댐의 분석 결과, 준공 후 경과년수와 댐 코어재의 열화 양상과는 상관성이 크게 없는 것으로 나타났다. 본 연구 결과는 코어형 필댐의 노후화에 따른 댐의 안전관리와 성능개선에 있어 유용한 자료로 활용 가능할 것으로 판단된다.

필댐의 3차원 기하 효과에 따른 전기비저항 왜곡 효과 분석 (Analysis of distortion effect of resistivity data due to 3D geometry of fill dam)

  • 오석훈;김형수
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2005년도 공동학술대회 논문집
    • /
    • pp.55-58
    • /
    • 2005
  • CFRD (콘크리트 표면 차수벽형 석괴댐)에서 수행한 전기비저항 탐사 결과, 하부에서 매우 낮은 비저항대가 관측되었다. 일반적으로 CFRD 형식의 댐은 내부 포화가 발생하지 않는 것으로 알려져 있으나, 금번 조사에서 하부 20m 깊이에서 일정하게 저비저항대가 발견되어 이에 대한 검토를 위해 3차원 해석을 수행하였다. 탐사 당시의 수위는 댐 정상부에서 10m 정도 내려가 있는 상태였다. 첫 탐사 이후 6개월이 지난 후에 이루어진 탐사에서도 비슷한 양상을 보이고 있었다. 이에 대한 해석을 위해서 조사 댐의 모양을 대상으로 3차원 순산 모델링을 수행하고, 이에 대한 2차원 역산 해석을 적용하여 기존 해석 방법의 오류 가능성을 검토하였다. 또한 비저항 조사가 많이 적용된 중심코아 형 댐의 경우의 사례와 비교하였다. 해석 결과, 3차원 댐체 구조에 대한 2차원 역산 해석은 저수부의 수위와 밀접한 관련을 갖는 것으로 보이며, 3차원의 사다리꼴 기하구조로 인하여 댐 내부에 비저항의 이상대가 존재할 경우에도 그 민감도가 떨어지는 것으로 분석되었다.

  • PDF

필댐의 3차원 기하 효과에 따른 전기비저항 왜곡 효과 분석 (Analysis of Distortion Effect of Resistivity Data Due to 3D Geometry of Fill Dam)

  • 오석훈;김형수
    • 지구물리
    • /
    • 제8권4호
    • /
    • pp.211-214
    • /
    • 2005
  • CFRD (콘크리트 표면 차수벽형 석괴댐)에서 수행한 전기비저항 탐사 결과, 하부에서 매우 낮은 비저항대가 관측되었다. 일반적으로 CFRD 형식의 댐은 내부 포화가 발생하지 않는 것으로 알려져 있으나, 금번 조사에서 하부 20m 깊이에서 일정하게 저비저항대가 발견되어 이에 대한 검토를 위해 3차원 해석을 수행하였다. 탐사 당시의 수위는 댐 정상부에서 10 m 정도 내려가 있는 상태였다. 첫 탐사 이후 6개월이 지난 후에 이루어진 탐사에서도 비슷한 양상을 보이고 있었다. 이에 대한 해석을 위해서 조사 댐의 모양을 대상으로 3차원 순산 모델링을 수행하고, 이에 대한 2차원 역산 해석을 적용하여 기존 해석 방법의 오류 가능성을 검토하였다. 또한 비저항 조사가 많이 적용된 중심코아형 댐의 경우의 사례와 비교하였다. 해석 결과, 3차원 댐체 구조에 대한 2차원 역산 해석은 저수부의 수위와 밀접한 관련을 갖는 것으로 보이며, 3차원의 사다리꼴 기하구조로 인하여 댐 내부에 비저항의 이상대가 존재할 경우에도 그 민감도가 떨어지는 것으로 분석되었다.

  • PDF

수변구조물의 누수 경로 탐지를 위한 변형된 전기비저항 탐사 및 자료 해석 (Modified Electrical Resistivity Survey and its Interpretation for Leakage Path Detection of Water Facilities)

  • 이보미;오석훈
    • 지구물리와물리탐사
    • /
    • 제19권4호
    • /
    • pp.200-211
    • /
    • 2016
  • 횡단 전위 배열(cross potential array)과 동일열 전위배열(direct potential array) 자료를 뒷받침하여 다양한 수변 구조물의 누수 경로 예측을 가능하게 하는 배열을 제시하고 이를 D-Lux array 라고 명명하였다. 또한 D-Lux array 자료를 색으로 가시화한 하나의 행렬로 정리하여 D-Lux view라고 제시하고 D-Lux view에서 관찰되는 저 전위차 이상대의 위치로 누수 구역의 위치를 해석하였다. D-Lux view의 보다 직관적인 해석을 위해서 D-Lux array 자료와 동일열 전위 배열 자료를 함께 사용하여 각 지점들 사이의 전위차 자료를 각 지점의 전위값으로 역산하고 이를 이용하여 등전위 분포도를 작성하였다. 등전위 분포도는 그래프나 D-Lux view에서 알 수 없었던 누수의 유입구, 유출구 뿐만 아니라 경로까지 예측 가능하게 하였다. 수조 실험과 수치 해석으로 예비 탐사를 실시한 후 현장 탐사로 콘크리트 보와 필 댐에 대한 적용이 이루어졌다. 그 결과, 콘크리트 보와 필 댐에 대해 누수 경로 탐지가 가능함을 확인하였다.