• Title/Summary/Keyword: ear protector

Search Result 4, Processing Time 0.019 seconds

Clinical Report of Aural Rehabilitation in Unilateral Sharply Slop Sensorineural Hearing Loss with Tinnitus and Increased Sound Sensitivity (이명과 청각민감증을 동반한 편측 고음 급추형 감각신경성 난청의 청각 재활)

  • Heo, Seung-Deok;Kang, Myung-Koo;Ko, Do-Heung;Jung, Dong-Keun
    • Speech Sciences
    • /
    • v.11 no.3
    • /
    • pp.175-180
    • /
    • 2004
  • In case of the hearing impairment with tinnitus and increased sound sensitivity, it is known that the patients tend to appeal the psychologically oriented social handicap rather than communication disability. The audiologist who is responsible for such patients in aural rehabilitation should pay special attention to the counseling techniques including tinnitus retain therapy (TRT), ear protector, noise generator, or specific acoustic training based on close cooperation and rapport. And then the audiologist should try to lessen their reaction to the tinnitus by using a hearing aid. This therapies tries to focus not a. total approach but a treatment to lessen the severity of tinnitus. This paper as a case report that a unilateral sharply slopped sensorineural hearing impaired person with tinnitus and increased sound sensitivity by using four channel digital signal processing (DSP) hearing aid with programming increment at low level (PILL).

  • PDF

Design of Small Acoustic Filter for ITE Type Noise Protector (ITE 타입의 소음 차폐기용 소형 음향 필터의 설계)

  • Lee, Yun-Jung;Kim, Pil-Un;Chang, Yong-Min;Lee, Sang-Heun;Cho, Jin-Ho;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.479-487
    • /
    • 2004
  • The prevention of noise induced hearing loss is very important, because there is no treatment for it. There are some kinds of devices for hearing protection, and those are effective in preventing a noise induced hearing loss. However, people often resist the use of hearing protection devices because it is difficult to have a conversation. Therefore, a hearing protection device is must effective not only in hearing protection but also in preserving communication ability. In this paper, we proposed a small acoustic filter for ITE type noise protector to solving the problem about the difficulties of conversation. That is applied a principle of acoustic filters that have been used for a muffler of automobiles, guns, and etc. To find out the sound transmission characteristic at the eardrum, we regarded an acoustic filter and external ear canal as a coupled system. So, we simulated the coupled system with OrCad, and experimented with a designed acoustic filter and a 2 cc coupler which has the same transmission characteristic as the external ear canal has. We confirmed that it is possible to adjustment acoustic transmission characteristics through simulation of electrical model for acoustic filter and external ear and experiments using designed small acoustic filters.

development of an ear-muff with active noise control for selective noise attenuation (특정주파수 소음제거를 위한 능동소음제어식 청각보호구 개발연구)

  • Kim, Dong-Gyun;Kim, Ok-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.12
    • /
    • pp.2068-2072
    • /
    • 1997
  • Acoustic noise has become an increasingly important issue, especially in the industrial environment. Nowadays home and office are not exceptional, mainly due to the increase in the usage of machinery. Active Noise Control(ANC) becomes efficiently an available tool for the noise suppression with rapid advances of solid state electronics. In this study an ANC system is developed for audio headphone to work as a noise protector, so called an ear-muff. The system is developed to kill a certain frequency band noises selectively which is purposed to suppress only the dominant ambient noise such that normal numan conversation is not disturbed with wearing the ear-muff. For the purpose, an ANC design strategy is suggested and implemented with an analogue control circuit. The performance is evaluated by frequency response test, which shows well consistence with theoretical one. The results are so satisfactory that noise of 640 Hz, which is aimed to suppress, is reduced by 20db without significant distortion in other frequency band.

A Study on Diagnostic Criteria of Noise-Induced Hearing Loss among Workers in an Iron Foundry (철강공장 근로자를 대상으로 살펴본 소음성 난청 진단기준에 관한 조사)

  • Kim, Ji-Yong;Lim, Hyun-Sul;Cheong, Hae-Kwan;Moon, Ok-Ryun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.3 s.43
    • /
    • pp.371-386
    • /
    • 1993
  • This study was carried out to evaluate diagnostic criteria of noise-induced hearing loss (NIHL) among-workers in an iron foundry. Of 1,093 workers under the observation of noise-specific health examination, 184 workers were selected by way of first and second screening audiometric examination. A questionnaire survey, otological examinations, Rinne test and audiometric test were performed and the results were as follows ; The degree of hearing impairment in the left ear was more severe than in the right ear (p<0.05). The difference between hearing threshold of the first and the second hearing test at 1,000 Hz was about 5 dB with a narrow range of deviations while the difference at 4,000 Hz was about -7 dB with a wide range. Of the total study workers, 84.8% were tested within 15 hours away from noise exposure, and the rest after 16 hours. This study has identified that mean hearing loss at 4,000 Hz showed a significant statistical difference among the two study groups while mean hearing loss by 4-divided classification did not. The same phenomena were observed between the group with and without tinnitus and between the group with and without difficulty in hearing (p<0.05). Among 184 workers, 10 workers (5.4%) diagnosed as NIHL by old diagnostic criteria in contrast to 150 workers diagnosed as NIHL by the new diagnostic criteria. There was a significant difference between the two groups in the average hearing loss at 4,000 Hz and 4-divided classification (p<0.01), but there were no significant differences in age, the duration of employment, blood pressure and the duration wearing the personal hearing protector (p>0.05). If we apply Early Loss Index (ELI) method, some workers in younger age group diagnosed as NIHL by the new diagnostic criteria were fallen into within the normal range. In the mean time older age group show reverse results in contrast to the above finding. It is too early to confirm the value of the usage of the new diagnostic criteria in hearing examination. Further study is called for to verify the value of this criteria.

  • PDF