• Title/Summary/Keyword: e-liquid

Search Result 1,520, Processing Time 0.027 seconds

A Study on the Small Disturbance Measurement of Liquid Film Thickness by $Moir\acute{e}$ Fringe ($Moir\acute{e}$ Fringe에 의한 액막 두께 미소 변위 측정 연구)

  • Jeon, H.S.;Kim, K.H.
    • Journal of ILASS-Korea
    • /
    • v.2 no.4
    • /
    • pp.29-35
    • /
    • 1997
  • Liquid film thickness is measured by $moir\acute{e}$ topography which monitored liquid surface. $Moir\acute{e}$ fringe measurement techniques share the inherent simplicity found in optical interferometric techniques have the advantage of use over a greater range of displacement. $Moir\acute{e}$ fringe are the geometric interference patterns observed when two dense line grating are superposed. Light transmitted through a fixed line grating is deviated by the liquid film surface, producing a distored image of the grating. The $moir\acute{e}$ fringe produced by projection of this optically distored grating onto a second stationary grating permit visualization of the liquid surface and measurement of the liquid film thickness. This study measured the small amplitude of liquid film thickness to the $moir\acute{e}$ fringe pattern produced when spherical metal was dropped glycerin put)1 And the measurement of liquid film thickness flowing down an inclined plate are required to calculate the liquid slope in a position.

  • PDF

Persistence of Salmonella enterica, Escherichia coli O157:H7, and Listeria monocytogenes in Soil, Liquid Manure Amended Soil, and Liquid Manure

  • Jung, Kyu-Seok;Kim, Min-Ha;Heu, Sung-Gi;Roh, Eun-Jung;Lee, Dong-Hwan;Lim, Jeong-A;Ryu, Jae-Gee;Kim, Kye-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.6
    • /
    • pp.432-436
    • /
    • 2014
  • While searching for healthier diets, people became more attentive to agricultural organic products. However, organic foods may be more susceptible to microbiological contamination because of the use of livestock manure compost and liquid manure, potential sources of pathogenic bacteria. This study was undertaken to investigate the persistence of Salmonella enterica, Escherichia coli O157:H7, and Listeria monocytogenes in soil, liquid manure amended soil, and liquid manure. Loamy soil, liquid manure amended soil, and liquid manure were inoculated with S. enterica, E. coli O157:H7, and L. monocytogenes. Samples were incubated in consistent moisture content at $25^{\circ}C$. Samples had been periodically collected during 120 days depending on the given conditions. S. enterica and E. coli O157:H7 survived over 120 days in loamy soil and over 60 days in liquid manure amended soil, respectively. L. monocytogenes decreased faster than other pathogens in soil. S. enterica, E. coli O157:H7, and L. monocytogenes survived for up to 5 days in liquid manure. S. enterica and E. coli O157:H7 in soil decreased by 2 to $2.5log\;CFU\;g^{-1}$ for 120 days. S. enterica and E. coli O157:H7 in liquid manure amended soil decreased slowly for 21 days. However, S. enterica, E. coli O157:H7, and L. monocytogenes sharply decreased after 21 days. S. enterica, E. coli O157:H7, and L. monocytogenes in soil increased by 0.5 to $1.0log\;CFU\;g^{-1}$ for 7 days. Foodborne pathogens in soil and liquid manure amended soil gradually decreased over time.

Simulation Study of an e-Beam Addressed Liquid Crystal Display for Projection

  • Zhou, Fushan;Yang, Deng-Ke;Molitor, R.J.
    • Journal of Information Display
    • /
    • v.3 no.4
    • /
    • pp.8-12
    • /
    • 2002
  • We have carried out a simulation study on an e-beam addressed liquid crystal projection display in which the liquid crystal is switched by the electric field of the charge, produced by an electron beam, on the surface of the display. We calculated the electric field produced by the surface charge, the liquid crystal director configuration and the profile of the transmitted light. We studied the factors affecting the resolution of the display and the effect of pretilt angle on the performance of the display. The e-beam addressed liquid crystal projection display potentially has the advantages of high resolution and high brightness.

Cardiac arrest and severe encephalopathy following e-cigarette nicotine intoxication: a case report (심정지 및 심각한 뇌병변 장애를 초래한 전자 담배용 Nicotine 중독 1례)

  • Jinwon Park;Sunghyun Yun
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.20 no.2
    • /
    • pp.82-85
    • /
    • 2022
  • Traditionally, most cases of nicotine poisoning have been due to ingestion of nicotine pesticides. However, the increasing use of electronic cigarettes (e-cigarettes) has resulted in both intentional and unintentional exposure to concentrated liquid nicotine or "e-liquid" leading to an increase in nicotine poisoning cases. However, fatalities following the ingestion of the e-liquid are extremely rare. We report a rare case of cardiac arrest and severe encephalopathy following the intentional ingestion of e-liquid. We present the case of a 20-year-old woman who intentionally ingested liquid nicotine intended for e-cigarette use. She was found in asystole and experienced a return of spontaneous circulation (ROSC) after undergoing approximately 46 mins of cardiopulmonary resuscitation. Her plasma nicotine levels were >500 ng/ml. Despite aggressive supportive care, she was found to have encephalopathy consistent with severe anoxic brain injury on magnetic resonance imaging. In recent times, there have been some reports of deaths following liquid nicotine ingestion. Our case illustrates the potential for fatal nicotine toxicity from ingestion of e-cigarettes.

Discrimination of biological and artificial nicotine in e-liquid

  • Hyoung-Joon Park;Heesung Moon;Min Kyoung Lee;Min Soo Kim;Seok Heo;Chang-Yong Yoon;Sunyoung Baek
    • Analytical Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.22-31
    • /
    • 2023
  • As the use of e-liquid cigarettes is rapidly increasing worldwide, it multiplies the potential risk undisclosed to the health of non- and smokers. To reduce the hazard, each country has its own set of regulations for controlling e-liquids. In Korea, the narrow definition of tobacco makes it difficult and have been steadily occurring tax evasion exploiting the difference in natural and artificial nicotine. Therefore, it is very important to distinguish source of nicotine for their regulation. To find biochemical discriminant markers, this study established analysis methods based on high-performance liquid chromatography coupled with diode array detector (HPLC-DAD) and high-performance liquid chromatography coupled with triple Quadrupole mass spectrometry (HPLC-MS/MS) for nicotine enantiomers and tobacco alkaloids targeted using the difference in pathways of nicotine biosynthesis and chemical synthesis. The method was validated by experimenting linearity (R2 > 0.999), recovery (80.99-108.41 %), accuracy (94.11-109.73 %) and precision (0.04-8.27 %). Then, the results for discrimination of the nicotine obtained from analysis of 65 commercial e-liquid products available in Korean market was evaluated. The method successfully applied to the e-liquids and one sample labelled 'synthetic nicotine' for tax exemption was found to contain a natural nicotine product. This method can be used to determine whether an e-liquid product uses natural or artificial nicotine and monitor non-taxable e-liquid products. The method is more scientific than the existing one, which relies only on field evidence.

The color comparison of zirconia fabricated by using various coloring liquids (수종의 색소체용액으로 제작된 유색 지르코니아의 색조비교)

  • Oh, Gye-Jeong;Jung, Jong-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.36 no.4
    • /
    • pp.247-253
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate the effect of colored zirconia with different coloring liquids. Methods: Total 30 specimens were prepared. Specimens were classified into 6 groups: IPS e.max Ceram(P), Uncolored zirconia(C), VITA In-Ceram$^{(R)}$2000 YZ LL1(L), Zirkonzahn coloring liquid(Z), Wieland coloring liquid(W), and Kuwotech coloring liquid(K). Four different types of zirconia coloring liquid, VITA In-Ceram$^{(R)}$ 2000 YZ LL1(VITA Zahnfabrik, Germany), Zirkonzahn coloring liquid(Zirkonzahn, Italy), Wieland coloring liquid(Wieland, Germany), Kuwotech coloring liquid(Kuwotech, Korea) were used to fabricate colored zirconia by using infiltrating method and then completely sintered. The color of the all specimens was measured using the spectrophotometer(CM-2600d, Konica Minolta, Japan) and expressed in terms of the 3-coordinated values(CIE $L^*a^*b^*$). Color differences were calculated using the equation $${\Delta}E^*=[({\Delta}L^*)^2+({\Delta}a^*)^2+({\Delta}b^*)^2]^{1/2}$$. Results: $L^*a^*b^*$ values of the colored zirconia were affected by the coloring liquids. The uncolored zirconia(C) group showed the highest $L^*$ value and zirkonzahn coloring liquid(Z) group showed the lowest $L^*$ value. Zirkonzahn coloring liquid(Z) showed the highest $a^*$ value and VITA In-Ceram 2000 YZ LL1(L) group showed the highest $b^*$ value. Generally, the color difference(${\Delta}E^*$) in all groups showed higher than 3.7 except between IPS e.max Ceram(P) and wieland coloring liquid(W) group. Conclusion: Within the limitations of this study, various coloring liquids influenced the $L^*$, $a^*$, and $b^*$ values of colored zirconia. IPS e.max Ceram(P) and wieland coloring liquid(W) group did not show clinically perceiving color difference.

Modeling an e-Beam Addressed Liquid Crystal Projection Display

  • Yang, Deng-Ke;Zhou, Fushan;Molitor, R.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.930-932
    • /
    • 2002
  • We have carried a theoretical study on e-beam addressed liquid crystal projection display in which the liquid crystal is switched by the electric field of the charge, produced by an electron beam, on the surface of the display. We calculated the electric field produced by the surface charge, the liquid crystal director configuration and the profile of the transmitted light. We studied the factors affecting the resolution of the display. We also studied the effect of pretilt angle on the performance of the display. The e-beam addressed liquid crystal projection display potentially has the advantages of high resolution and high brightness.

  • PDF

Effective determination of nicotine enantiomers from e-liquids and biological fluids by high performance liquid chromatography (HPLC) using dispersive liquid-liquid microextraction (DLLME)

  • Song, Seunghoon;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.180-190
    • /
    • 2021
  • This study compared the efficacy of chiral GC and chiral HPLC for the analysis of nicotine. To develop a suitable dispersive liquid-liquid microextraction (DLLME) method, the following parameters were optimized: pH, extraction solvent, dispersive solvent, type and quantity of salt, and laboratory temperature. The validation of the method was carried out by the established HPLC method. The LODs were 0.11 ㎍/mL and 0.17 ㎍/mL for the (S)- and (R)- enantiomers, respectively. The LOQs were 0.30 ㎍/mL and 0.44 ㎍/mL, respectively. The optimal calibration range was between 0.30-18 ㎍/mL and 0.44-4.40 ㎍/mL, respectively, and the correlation coefficient (r2) was 0.9978-0.9996. The intra-day accuracy was 79.9-110.6 %, and the intra-day precision was 1.3-12.0 %. The inter-day accuracy was 87.8-108.0 %, and the inter-day precision was 4.0-12.8 %. E-liquid and biological fluids (urine and saliva) were analyzed using the established method.

Review on Toxic Substances in the Liquid and Gas Phases of Electronic Cigarettes (전자담배 액상 및 기체상 중 유해물질 고찰)

  • Shin, Ho-Sang
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.6
    • /
    • pp.483-491
    • /
    • 2013
  • Objectives: Electronic cigarettes are battery powered devices that convert a nicotine-containing liquid into an inhalable vapor. The device aerosolizes nicotine so that it is readily entrained into the respiratory tract, from where it enters the bloodstream. Information on the safety of E-cigarettes is required. Methods: Seventeen articles on studies analyzing toxic substances in the liquid and gas phases of electronic cigarettes were reviewed. Results: Tobacco-specific nitrosamines, bis(2-ethylhexyl) phthalate, formaldehyde and acetaldehyde, known to be carcinogenic agents in humans or animals, were detected in the liquid and gas phases. In addition, diethyl phthalate, acetone, ethanol, cresol, xylene, propylene, styrene, triethylene glycol, tetraethylene glycol, pentaethylene glycol cis-3-hexen-1-ol, methyl cinnamate and undecane were identified in the liquid and gas phases of E-cigarettes. Propylene glycol, glycerin, 1-methoxy-2-propanol, 1-hydroxy-2- propanone, acetic acid, 1-menthone, 2,3-butanediol, menthol, carvone, maple lactone, benzyl alcohol, 2-methyl-2-pentanoic acid, ethyl mantel, ethyl cinnamate, myosamine, benzoic acid, 2,3-bipyridine, cotinine, hexadecanoic acid, and 1'1-oxybis-2-propanol were detected in the vapors of E-cigarettes. Conclusion: The hazardous compounds identified in the liquid and gas phases of E-cigarettes should be controlled for the lowest concentrations in the raw materials and production procedures.

Thermal Inactivation of Salmonella enteritidis, Salmonella typhimurium and E. coli O111 in Liquid Cultures During Microwave Radiation (Microwave 조사에 의한 Salmonella enteritidis, Salmonella typhimurium 과 E. coli의 불활성에 관한 연구)

  • 이조윤;이강욱;배형철;김종우
    • Food Science of Animal Resources
    • /
    • v.18 no.3
    • /
    • pp.269-275
    • /
    • 1998
  • The purpose of this study was to determine the thermal inactivation of Salmonella enteritidis, Salmonella typhimurium and E. coli O111 in liquid cultures treated with microwave energy. Furthermore, this study was to introduce new methodologies for studying nonthermal microwave effects on microorganisms, using controlled microwave energy and specially designed apparatuses. For the automatic temperature control during microwave heating, the real time data acquisition and computation system is designed with BASIC routine. The automatic temperature control system used in the experiments perform relatively stable control at the experiment temperature of 45, 50, 55 60$^{\circ}C$ and 65$^{\circ}C$ for 30 minutes. The effects of microwave heating on liquid cultures was compared with that of conventional heating, still reduces effectively the number of pathogenic bacteria in liquid cultures. While no particular differences between microwave heating and conventional heating was observed in the activation of E. coli at 45$^{\circ}C$ test, the activation of Sal. enteritidis and Sal. typhimurium was slightly reduced during the microwave treatments.

  • PDF