• 제목/요약/키워드: e-N curve

검색결과 220건 처리시간 0.022초

고온초전도 더블 팬케이크 코일들 사이의 접합 방법 (A Joining Method between HTS Double Pancake Coils)

  • 손명환;심기덕;김석호;김해종;배준한;이언용;민치현;성기철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권12호
    • /
    • pp.633-639
    • /
    • 2006
  • High temperature superconductor (HTS) winding coil is one of the key component in superconducting device fabrication. Double-pancake style coils are widely used for such application. High resistance between pancake coils greatly affects the machine design, operating condition and thus the stability. In order to reduce such resistance, experimentalists are looking for efficient and damage free coil connecting methods. In this respect, here we proposed parallel joining method to connect the coils. This is to do crossly joining with HTS tapes on two parallel HTS tapes. Joint samples between two parallel HTS tapes were prepared by using HTS tapes and current-voltage (I-V) characteristic curves were investigated at liquid nitrogen temperature i.e., 77.3 K. A 20 cm length joint connected between two parallel HTS tapes shows $32.5n{\Omega}$, for currents up to 250 A. A small HTS magnet, having two double pancake sub-coils connected together through new parallel joint method was fabricated and their current-voltage (I-V) characteristic curve was investigated. At 77.3K, critical current(Ic) of 97 A and resistance of $55n{\Omega}$ for currents upto 130 A were measured. At operating current 86 A lower than Ic, Joule heats generated in whole magnet and at joint region between sub-coils were 226 mW and 0.4 mW, respectively. Low Joule heat generation suggests that this joining method may be used to fabricate HTS magnet or windings.

Ionic Dependence and Modulatory Factors of the Background Current Activated by Isoprenaline in Rabbit Ventricular Cells

  • Leem, Chae-Hun;Lee, Suk-Ho;So, In-Suk;Ho, Won-Kyung;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • 제26권1호
    • /
    • pp.15-25
    • /
    • 1992
  • In order to elucidate the properties of the background current whole cell patch clamp studies were performed in rabbit ventricular cells. Ramp pulses of ${\pm}80\;mV$ from holding potential of 40 mV(or 20 mV) at the speed of 0.8 V/sec were given every 30 sec(or 10 sec) and current-voltage diagrams(I-V curve) were obtained. For the activation of the background current isoprenaline, adenosine 3',5'-cyclic monophosphate(dBcAMP), guanosine 3',5'-cyclic monophosphate(cGMP), and $N^6$-2'-o-dibutyryladenosine 3',5'-cyclic monophosphate(dBcAMP) were applied after all known current systems were blocked with 2mM Ba, 1 mM Cd ,5 mM Ni, 10 ${\mu}M$ diltiazem, 10 ${\mu}m$ ouabain, and 20 mM tetraethylammonium(TEA). The conductance of background current in control was $0.65{\pm}0.69$ nS at 0 mV, its I-V curves was almost linear and reversed near 50 mV. When there was no taurine in pipette solution, isoprenaline hardly activated the background current but when taurine existed in pipette solution, isoprenaline activated the larger background current. Cyclic AMP or cyclic GMP alone had little effect on the activation of the background current, while cGMP potentiated cGMP effect. When the background current was activated with cGMP and cAMP, isoprenaline could not further increased the background current. The background current activated by isoprenaline depended on extracellular $Cl^-$ concentration and its reversal potential was shifted according to chloride equilibrium potential. The change of extracellular $Na+$ concentration had little effect on reversal potential of the background current activated by isoprenaline.

  • PDF

Ti-6Al-4V 재의 UNSM 처리에 의한 피로특성변화 - 회전굽힘 피로시험과 축하중 인장압축 피로시험 비교 - (Variation of Fatigue Properties in Nanoskinned Ti-6Al-4V - Rotating Bending and Axial Loading Tension-Compression Cycle -)

  • 서민수;편영식;서창민
    • 대한기계학회논문집A
    • /
    • 제36권4호
    • /
    • pp.443-449
    • /
    • 2012
  • Ti-6Al-4V 재에 다양한 표면처리방법을 통하여 나노스킨화된 피로시험편을 제작하고 회전굽힘피로 시험과 축하중 인장압축피로시험을 수행하였다. 특히 S-N 곡선에서 초음파나노표면개질(UNSM)법은 국내특허기술로 다른 처리법들보다 우수한 결과를 보였고, UNSM 처리된 직경 5 mm 재는 6 mm 티타늄재를 대치 가능할 성능을 얻었다. UNSM 처리된 $10^6$ 사이클 이상의 장수명영역에서 피로강도가 크게 향상되는 시험결과를 얻었다. 균열발생 패턴의 분석을 통하여 Ti-6Al-4V 재는 응력의 작용형태에 따라 표면균열발생형(surface originating crack type)과 내부균열발생형(interior originating crack type)인 어안균열(fish eye crack)이 발생하는 메커니즘을 분석하였다.

아자크라운 에터를 포함한 이온교환수지에 의한 리튬 동위원소의 농축 (Enrichment of Lithium Isotope by an Ion Exchange Resin Containing Azacrown Ether)

  • 김동원;정용순;최기영;이용일;정영규;장영훈
    • 분석과학
    • /
    • 제10권6호
    • /
    • pp.403-407
    • /
    • 1997
  • Anchor group으로서 1,7,13-trioxa-4,10,16-triazacyclooctadecane($N_3O_3$)을 가지고 있는 이온교환수지를 사용하여 $^6Li$$^7Li$의 분리인자를 측정하였다. 가벼운 동위원소 $^6Li$는 액상에, 무거운 동위원소 $^7Li$는 이온교환수지상에 농축되었다. 2.0M 염화암모늄 용액을 용리액으로 사용한 컬럼 [0.9cm(내경)${\times}$20cm(높이)] 크로마토그래피에 의하여, 1.009의 분리인자, ${\alpha}$, $(^7Li/^6Li)_{resin}$/$(^7Li/^6Li)_{solution}$값을 얻었다. 이 값은 용리곡선과 동위원소비로부터 Glueckauf 이론을 적응하여 얻은 것이다.

  • PDF

메바코정(로바스타틴 20 mg)에 대한 동성로바스타틴정의 생물학적 동등성 (Bioequivalence of Dong Sung Lovastatin Tablet to Mevacor Tablet (Lovastatin 20 mg))

  • 최민구;최미희;김경식;김인화;이영주
    • 약학회지
    • /
    • 제45권2호
    • /
    • pp.220-226
    • /
    • 2001
  • A bioequivalence study of Lovastati $n^{TM}$ tablets (Dong Sung Pharmaceutical Co., Korea) to Mevaco $r^{TM}$ tablets (Choong Wae Pharmaceutical Co., Korea) was conducted according to the guidelines (No. 98-56) of Korea Food and Drug Administration (KFDA). Each tablet contained 20 mg of lovastatin. Eighteen healthy Korean male subjects received each formulation at a lovastatin dose of 80 mg (i.e., four tablets) in a 2 $\times$ 2 crossover study. There was a washout period of a week between the dose of the two formulations. Plasma concentrations of lovastatin acid were monitored by a GC/MS method for over a period of 12hr after each administration. The area under the plasma concentration-time curve from time zero to 12hr (AUC) was calculated by a linear trapezoidal method. The maximum plasma drug concentration ( $C_{max}$) and the time to reach $C_{max}$ ( $T_{max}$) were compiled from the plasma drug concentration-time data. Analysis of variance (ANOVA) of these parameters revealed that there are no differences in AUC and $C_{max}$ between the formulations. The apparent differences between the formulations in these parameters were 4.87 and 8.03% for AUC and $C_{max}$, respectively. Minimum detectable differences (%) at $\alpha$=0.1 and 1-$\beta$=0.8 were 17.84 and 15.36% for AUC and $C_{max}$ respectively. The 90% confidence intervals were -15.30~5.56 and -17.02-0.95% for AUC and $C_{max}$, respective1y. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Mevaco $r^{TM}$ tablets and Dong Sung Lovastati $n^{TM}$ tablets are bioequivalent.ivalent.ent.alent.ent.

  • PDF

염소의 산·염기 균형 특성에 관한 연구 (A Study on Characteristics of Acid-Base Balance in Goats)

  • 양일석;성호경
    • 대한수의학회지
    • /
    • 제25권2호
    • /
    • pp.133-144
    • /
    • 1985
  • The changes of acid-base status in vitro of the venous blood for 24 hours in ten Korean native goat were investigated. The acid-base parameters were measured within ten minutes after collection of the blood, and every hour during the first six hours and finally after twenty four hours of storage. Blood samples were stored at two different temperatures ($0-4^{\circ}C$ and $21-24^{\circ}C$). Twelve goats were induced acute acid-base disturbances by intravenous infusion of either hydrochloric acid or sodium bicarbonate and inhalated with $CO_2$ gas mixture (20% $CO_2$, 80% $O_2$) or hyperventilation were performed by means of respirator. The results were as follows; 1. Blood samples could be stored during the first two hours in ice water ($0-4^{\circ}C$) and one hour at room temperature without significant changes in pH. The magnitudes of changes were similar to those of cow, and lower than those of men and dogs. 2. The mean values of acid-base parameters in normal goat were arterial pH, 7.40; $P_{CO_2}$, 35.4mmHg; $HCO_3{^-}$, 21.8mEq/L. 3. Both the base excess and the bicarbonate showed high correlation (r=0.99) during the metabolic disturbance and were represented as $B.E.=1.38\;HCO^-{_3}-29.7$. 4. The slope of blood buffer curve obtained from the in vivo experiment was 16.3mEq/L/pH. 5. The magnitudes of changes in hydrogen ion concentration per unit change of $P_{CO_2}$ were 0.8nM/mmHg in hypercapnia and 1.0nM/mmHg in hypocapnia. 6. The ranges of acid-base parameters in normal goat urine were pH, 6.0-8.1; $P_{CO_2}$, 42-61mmHg; $HCO_3{^-}$, 2-110mEq/L. The concentration of potassium was higher (60-200mEq/L), and that of sodium was lower (8-70mEq/L) than those of human urine.

  • PDF

콘크리트재료의 열특성 및 수화열 해석 (Characterization of Thermal Properties of Concrte and Temperature Prediction Model)

  • 양성철
    • 콘크리트학회지
    • /
    • 제9권2호
    • /
    • pp.121-132
    • /
    • 1997
  • 콘크리트의 열해석은 콘크리트 초기온도, 환경조건 및 시멘트의 수화 등에 의해 특징지워진다. 이러한 상호관계를 모두 고려한 프로그램을 만들어서, 콘크리트재료의 열특성과 환경조건을 감안한 콘크리트 구조물의 온도해석을 하였다. 시멘트 수화의 특성으로는 활성화에너지, 단위열량, 수화열이 있으며 이러한 인자들에 의해 콘크리트의 내부열 발생이 영향을 받는다. 본 연구에서는 활성화에너지와 수화열을 상대강도-등가재령모델에 의해 구했으며, 단위열량은 등온열량측정법에 의해 실험적으로 구하였다. 또한 콘크리트 구조물의 온도분포를 실험적으로 구하여 수치해석모델과 비교하였다. 먼저 위에서 제시된 모든 조건들에 대한 parametric 해석을 실시하여 프로그램의 신뢰성을 확보하였다. 그리고 원주형시편을 만들어서 온도분포 및 변화를 측정하여 수치해석에 의해 예측된 온도분포와 비교하였다.

입목(立木)의 이용재적(利用材積)에 대(對)하여 (Studies on utilizing Volume)

  • 김갑덕
    • 한국산림과학회지
    • /
    • 제3권1호
    • /
    • pp.10-14
    • /
    • 1963
  • 광야소재(光陽所在) 천연성(天然性) 소나무에 대(對)하여 조사(調査)한 결과(結果)는 다음과 같다. 1. 수고성장(樹高成長) $H=4.76+0.125D+0.0026D^2$ 2. 소나무의 입목재적식(立木材積式)은 $V=0.0000839D^{2.3}H^{0.2}$ 3. 이용재적(利用材積)과 재장간(材長間)에는 Vu=0.1708-0.0230L 4. 이용율(利用率)은 재장(材長)을 2m로 했을 때 $P=27.37D^{0.3648}$ 5. 조재가능(造材可能)한 2m 재장(材長)의 수(數)는 $N=0.0863D^{1.16}$ 6. 이용재적식(利用材積式)은 재장(材長)을 2m로 했을 경우 $Vu=0.0000159D^2H^{1.3}$ 위의 결과(結果)는 종합적(綜合的)으로 재장(材長)을 2m 후 조재(造材)할 때 이용재적(利用材積)이 가장 많다는 것을 명백(明白)히 하였다.

  • PDF

The Prognostic Value of Lymph Node Ratio after Neoadjuvant Chemotherapy in Patients with Locally Advanced Gastric Adenocarcinoma

  • Zhu, Kankai;Jin, Hailong;Li, Zhijian;Gao, Yuan;Zhang, Qing;Liu, Xiaosun;Yu, Jiren
    • Journal of Gastric Cancer
    • /
    • 제21권1호
    • /
    • pp.49-62
    • /
    • 2021
  • Purpose: This study aimed to investigate the prognostic value of lymph node ratio (LNR) in patients with locally advanced gastric cancer who received neoadjuvant chemotherapy. Materials and Methods: We retrospectively enrolled gastric cancer patients treated with neoadjuvant chemotherapy and curative surgery at the First Affiliated Hospital of Zhejiang University from 2004 to 2015 as the study cohort. Patients with the same inclusion criteria treated in 2016-2017 were enrolled as the validation cohort. Kaplan-Meier curves were assessed using the log-rank test to analyze the differences in overall survival (OS). Multivariate survival analysis was performed using the Cox proportional hazards model. The areas under the receiver operating characteristic curve of ypN and LNR categories for predicting the actual 3-year OS were compared. Results: A total of 265 patients were included in the proposal cohort. The median number of retrieved lymph nodes (rLNs) was 32. The number of positive lymph nodes (pLNs) increased as rLN increased (P=0.037), but the LNR remained relatively constant (P=0.462). The LNR was categorized into 4 groups according to the prognosis: ypNr0, node-negative with rLN>25; ypNr1, node-negative with rLN≤25 or 00.3. In the validation cohort of 43 enrolled patients, there was a clear distinction in OS that significantly (P<0.001) varied depending on the LNR values and LNR was the only independent prognostic factor in multivariate analysis (P<0.001). Conclusions: LNR was an independent prognostic factor for survival of patients with gastric cancer after preoperative chemotherapy and might be an alternative predictor for ypN stage.

CEM BIO Film 피복시설의 환경특성과 풋고추 생육 (Greenhouse Environment and Growth of Green Pepper (Capsicum annuum L.) in Greenhouse Covered with CEM BIO Film)

  • 전희;김경제;권영삼;김현환;이시영
    • 생물환경조절학회지
    • /
    • 제9권3호
    • /
    • pp.161-165
    • /
    • 2000
  • CEM BIO P.E.필름으로 피복된 시설에서 300~1,100nm 사이의 분광투과율은 일반 P.E. 필름으로 피복된 시설보다 높았다. 전반적으로 시설내 광투과율은 이중피복, 골조, 기타시설물 때문에 노지에 비하여 절반 수준을 나타냈다. 순복사량은 CEM BIO P.E. 필름 피복시설이 5,424.5W.m$^{-2}$ 로서 일반 P.E.필름 피복시설보다 2.9% 낮았고, 광합성유효복사 투과율은 CEM BIO P.E.필름 피복시설이 3,861.2W.n$^{-2}$ 로서 일반 P.E. 필름 피복시설보다 3.8% 높았으며, 무가온기의 적산최저온도는 CEM BIO P.E. 필름 피복시설이 일반 P.E. 필름 피복시설보다 1일 평균 0.35$^{\circ}C$ 높았다. 정식후 30일의 풋고추 생육은 CEM BIO P.E. 필름 피복시설에서 초장, 경경, 엽면적, 생체중, 건물중 및 군락생산구조가 우수하였고, 과실은 과중이 11.28g으로 일반 P.E. 필름 피복시설 보다 1.25g 무거웠으며, 상품율은 2.7% 높았다. 1997년 11월 19일부터 1998년 3월 3일 사이의 수량은 CEM BIO P.E. 필름피복시설에서 7.4% 많았으나 전체적인 수량은 차이를 보이지 않았다.

  • PDF