• 제목/요약/키워드: dynamic time history analysis

검색결과 515건 처리시간 0.028초

Performance of passive and active MTMDs in seismic response of Ahvaz cable-stayed bridge

  • Zahrai, Seyed Mehdi;Froozanfar, Mohammad
    • Smart Structures and Systems
    • /
    • 제23권5호
    • /
    • pp.449-466
    • /
    • 2019
  • Cable-stayed bridges are attractive due to their beauty, reducing material consumption, less harm to the environment and so on, in comparison with other kinds of bridges. As a massive structure with long period and low damping (0.3 to 2%) under many dynamic loads, these bridges are susceptible to fatigue, serviceability disorder, damage or even collapse. Tuned Mass Damper (TMD) is a suitable controlling system to reduce the vibrations and prevent the threats in such bridges. In this paper, Multi Tuned Mass Damper (MTMD) system is added to the Ahvaz cable stayed Bridge in Iran, to reduce its seismic vibrations. First, the bridge is modeled in SAP2000 followed with result verification. Dead and live loads and the moving loads have been assigned to the bridge. Then the finite element model is developed in OpenSees, with the goal of running a nonlinear time-history analysis. Three far-field and three near-field earthquake records are imposed to the model after scaling to the PGA of 0.25 g, 0.4 g, 0.55 g and 0.7 g. Two MTMD systems, passive and active, with the number of TMDs from 1 to 8, are placed in specific points of the main span of bridge, adding a total mass ratio of 1 to 10% to the bridge. The parameters of the TMDs are optimized using Genetic Algorithm (GA). Also, the optimum force for active control is achieved by Fuzzy Logic Control (FLC). The results showed that the maximum displacement of the center of the bridge main span reduced 33% and 48% respectively by adding passive and active MTMD systems. The RMS of displacement reduced 37% and 47%, the velocity 36% and 42% and also the base shear in pylons, 27% and 47%, respectively by adding passive and active systems, in the best cases.

Seismic behavior of liquid storage tanks with 2D and 3D base isolation systems

  • Kilic, Samet;Akbas, Bulent;Shen, Jay;Paolacci, Fabrizio
    • Structural Engineering and Mechanics
    • /
    • 제83권5호
    • /
    • pp.627-644
    • /
    • 2022
  • In past major earthquakes (1994 Northridge, 1995 Kobe, Chi-Chi 1999, Kocaeli 1999), significant damages occurred in the liquid storage tanks. The basic failure patterns were observed to be the buckling of the tank wall and uplift of the anchorage system. The damages in the industrial facilities and nuclear power plants have caused the spread of toxic substances to the environment and significant fires. Seismic isolation can be used in liquid storage tanks to decouple the structure and decrease the structural demand in the superstructure in case of ground shaking. Previous studies on the use of seismic isolation systems on liquid storage tanks show that an isolation system reduces the impulsive response but might slightly increase the convective one. There is still a lack of understanding of the seismic response of seismically isolated liquid storage tanks considering the fluid-structure interaction. In this study, one broad tank, one medium tank, and one slender tank are selected and designed. Two- and three-dimensional elastomeric bearings are used as seismic isolation systems. The seismic performance of the tanks is then investigated through nonlinear dynamic time-history analyses. The effectiveness of each seismic isolation system on tanks' performance was investigated. Isolator tension forces, modal analysis results, hydrodynamic stresses, strains, sloshing heights and base shear forces of the tanks are compared. The results show that the total base shear is lower in 3D-isolators compared to 2D-isolators. Even though the tank wall stresses, and strains are slightly higher in 3D-isolators, they are more efficient to prevent the tension problem.

Collapse failure mechanism of subway station under mainshock-aftershocks in the soft area

  • Zhen-Dong Cui;Wen-Xiang Yan;Su-Yang Wang
    • Geomechanics and Engineering
    • /
    • 제36권3호
    • /
    • pp.303-316
    • /
    • 2024
  • Seismic records are composed of mainshock and a series of aftershocks which often result in the incremental damage to underground structures and bring great challenges to the rescue of post-disaster and the repair of post-earthquake. In this paper, the repetition method was used to construct the mainshock-aftershocks sequence which was used as the input ground motion for the analysis of dynamic time history. Based on the Daikai station, the two-dimensional finite element model of soil-station was established to explore the failure process of station under different seismic precautionary intensities, and the concept of incremental damage of station was introduced to quantitatively analyze the damage condition of structure under the action of mainshock and two aftershocks. An arc rubber bearing was proposed for the shock absorption. With the arc rubber bearing, the mode of the traditional column end connection was changed from "fixed connection" to "hinged joint", and the ductility of the structure was significantly improved. The results show that the damage condition of the subway station is closely related to the magnitude of the mainshock. When the magnitude of the mainshock is low, the incremental damage to the structure caused by the subsequent aftershocks is little. When the magnitude of the mainshock is high, the subsequent aftershocks will cause serious incremental damage to the structure, and may even lead to the collapse of the station. The arc rubber bearing can reduce the damage to the station. The results can offer a reference for the seismic design of subway stations under the action of mainshock-aftershocks.

Study on response of a new double story isolated structure under earthquakes

  • Hang Shan;Dewen Liu;Zhiang Li;Fusong Peng;Tiange Zhao;Yiran Huo;Kai Liu;Min Lei
    • Earthquakes and Structures
    • /
    • 제27권1호
    • /
    • pp.17-29
    • /
    • 2024
  • The traditional double story isolated structure is a derivative of the base isolated and inter-story isolated structures, while the new double story isolated structure represents a novel variation derived from the traditional double story isolated structure. In order to investigate the seismic response of the new double story isolated structure, a comprehensive structural model was developed. Concurrently, models for the basic fixed, base isolated, inter-story isolated, and traditional double story isolated structures were also established for comparative analysis. The nonlinear dynamic time-history response of the new double story isolated structure under rare earthquake excitations was analyzed. The findings of the study reveal that, in comparison to the basic fixed structure, the new double story isolated structure exhibits superior performance across all evaluated aspects. Furthermore, when compared to the base isolated and inter-story isolated structures, the new double story isolated structure demonstrates significant reductions in inter-story shear force, top acceleration, and inter-frame displacement. The horizontal displacement of the new double story isolated structure is primarily localized within the two isolation layers, effectively dissipating the majority of input seismic energy. In contrast to the traditional double story isolated structure, the new design minimizes displacements within the inter-isolation layer situated in the central part of the frame, as well as mitigates the overturning forces acting on the lower frame column. Consequently, this design ensures the structural integrity of the core tube, thereby preventing potential collapse and structural damage.

광산 발파 시 인근지역에 미치는 발파영향에 대한 환경적 접근 (Environmental Approach to Blasting Effect on the Surrounding Area when the Mine Blasting)

  • 정병훈;이승호
    • 한국지반환경공학회 논문집
    • /
    • 제16권12호
    • /
    • pp.5-12
    • /
    • 2015
  • 발파소음은 충격음이기 때문에 인체에 갑작스런 충격을 주며, 발파진동과 같은 경우에는 지반을 따라 진동이 이동하여 인근 주변의 노화된 건물, 가축과 인체에도 큰 피해를 끼칠 수 있다. 본 연구에서는 광산 굴착 시 발생하는 발파영향이 인근지역에 미치는 영향에 대하여 분석하였다. 연구대상 지역의 지반현황을 파악하기 위해 지질조사, 현장시험과 실내시험 등의 지반조사를 수행하였다. 발파진동소음에 대해서는 국내 외 적용사례와 각 기관별 허용기준을 비교하여 현장조건에 가장 적합한 기준을 설정하였다. 발파영향을 검토하기 위해 발파진동 추정 식은 현장에서 시험발파를 수행하여 측정된 발파진동 값을 활용하였다. 발파진동 추정 식을 활용한 영향원의 검토는 발파지점을 보안물건(농장, 민가 등)으로부터 최단거리로 정하여 보안물건에 미치는 영향을 검토하였다. 또한 3차원 수치해석을 수행하여 발파진동 영향검토를 수행하였다. 3차원 수치해석은 동적 발파하중에 대한 구조물의 거동을 해석하기 위해 시간이력해석을 수행하였으며, 3방향에 대한 발파진동 값을 구하였다. 시험발파에 따른 발파진동 추정 식을 이용한 발파진동 영향원 검토 결과와 발파영향에 대한 3차원 수치해석 값을 비교 분석한 결과, 유사한 결과 수치를 확인하였다.

공용 사장교의 동적특성을 반영하는 버페팅 응답보정법 (Buffeting Response Correction Method based on Dynamic Properties of Existing Cable-Stayed Bridge)

  • 김병철;임성순
    • 대한토목학회논문집
    • /
    • 제33권1호
    • /
    • pp.71-80
    • /
    • 2013
  • 설계를 위한 교량의 해석모델은 구조물의 안전성을 확보하기 위해 자중 및 외부하중은 되도록 크게, 구조물의 강성은 되도록 작게 평가하는 것이 일반적이다. 때문에 설계모델을 이용한 버페팅 응답은 실제 공용교량의 버페팅 응답과 차이를 나타낸다. 공용교량의 버페팅 응답을 정확하게 예측하기 위해서는 공용교량의 동적특성을 계측하여 해석모델이 계측값을 반영하도록 수정하여야 한다. 일반적으로, 실제교량과 동일한 고유진동수를 갖는 MBM(Measurement -based Model)을 구축하기 위해 설계모델의 다양한 물성치를 파라미터로 조정하며 계측된 고유진동수와 일치시키는 MTM(Manual Tuning Method)이 사용되고 있다. MTM은 파라미터의 초기치 설정에 따른 임의성이 높고 여러 수렴점을 가질 수 있어 분석에 상당한 노력이 소요된다. 본 연구는 버페팅해석에 널리 적용되고 있는 단일모드 주파수영역 해석법이 구조물의 모드형상, 고유진동수 및 감쇠비의 동적특성만을 이용하는 점에 착안하여 MTM과정 없이 설계모델의 버페팅 응답을 공용교량의 버페팅 응답으로 보정하는 BRCM(Buffeting Response Correction Method)을 제안하였다. BRCM은 설계모델의 모드형상 별 버페팅 응답을 공용교량의 고유진동수만으로 보정하는 방법이다. 공용교량의 고유진동수는 상시진동에 의한 계측 가속도로부터 산정하였다. BRCM의 적용성을 단순보 모델의 시간이력 버페팅해석을 수행하여 수치적으로 평가하였으며 공용교량모델을 이용한 버페팅해석결과, BRCM과 MTM의 응답 차이는 3% 이하로 나타났다. 공용교량의 실시간 계측시스템에 BRCM을 도입할 경우 사장교의 유지관리 효율성을 높일 수 있을 것으로 기대된다.

타입 말뚝의 지지력 증가효과 특성 (The Characteristics of the Set-up Effect of Driven Piles)

  • 조천환
    • 한국지반공학회논문집
    • /
    • 제19권4호
    • /
    • pp.235-246
    • /
    • 2003
  • 국내의 경우 이 등(1994)의 연구를 시작으로 국지 현장별로 타입말뚝의 지지력 증가효과에 대한 사례연구들이 있었다. 그러나 충분한 시험자료를 바탕으로 한 지지력 증가효과에 대한 전반적인 검토는 아직 미흡한 실정이고, 또한 지지력 증가효과에 지반조건 및 말뚝의 형상이 미치는 영향에 대해서는 아직 보고 된 바 없다. 타입말뚝의 지지력 증가효과를 실무적으로 이용하기 위해서는 현장에서 실구조물에 적용된 말뚝에 대한 시험자료의 분석을 실시하는 것이 필요하다. 본 연구에서는 말뚝기초의 설계 및 향후 사질토에서의 지지력 증가효과 등의 연구를 위한 기본 자료로 활용하기 위해 실구조물에 적용되는 다양한 시험말뚝의 시공과 동재하시험 자료 분석을 통해 지지력 증가효과에 대한 현상을 알아보았다. 말뚝의 동재하시험의 분석 결과, 말뚝지지력의 증가는 토질별로도 영향을 받지만 조성이력에도 영향을 받는 것으로 분석되었으며, 특히 사질토에도 상당한 지지력 증가효과가 나타났다. 이러한 말뚝의 지지력의 증가는 주로 주면부에서 발생하였으며, 선단형상에 따른 지지력 증가효과는 점성토에서는 폐단말뚝이 크고, 사질토에서는 개단말뚝이 큰 것으로 나타났다.

MarkIII LNG 방열 시스템의 강도평가를 위한 삼각형 충격 하중에 대한 구조응답에 대한 연구 (Study on Structural Strength of Mark III type LNG Cargo Containment System by Idealized Triangular Impulse Load)

  • 황세윤;김성찬;이장현;노인식
    • 한국전산구조공학회논문집
    • /
    • 제27권6호
    • /
    • pp.615-624
    • /
    • 2014
  • LNG 방열 시스템의 선형 동적해석 모델을 사용하여 슬로싱 충격 압력을 구조해석에 적용 시 사용되는 이상화된 삼각파 압력에 대해서 검토하였다. 삼각파 압력의 최대값, 지속시간, 비대칭성의 충격파에 대한 구조 안전성 평가를 위해서 멤브레인 구조의 허용기준과 슬로싱 압력에 관련된 간략화된 파괴압력에 대해 검토하고, 슬로싱 충격 압력의 지속시간과 비대칭성으로 특징 지워진 이상화된 삼각파 형상의 압력을 고려한 일련의 선형 동적해석을 수행하여 설계기준으로 사용할 파괴압력을 도출하였다. 본 논문에서 제시한 방법을 통해서 방열시스템 구조 요소의 안전성을 평가하기 위한 파괴 압력을 선정할 수 있고 모형실험을 통한 슬로싱 압력과의 비교를 통하여 방열시스템의 구조안전성을 평가할 수 있을 것이라 판단된다. 또한 해석결과를 통해 방열시스템에서의 최대 응력은 매우 짧은 순간의 충격하중 하에서는 압력의 비대칭성 보다는 하중 지속시간에 많은 영향을 받고 있음을 검토하였다.

국내 기존 학교건축물의 내진보강 후 비선형 거동특성 (Nonlinear Behavior of Seismic-Strengthened Domestic School Building)

  • 류승현;윤현도;김선우;이강석;김용철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.243-253
    • /
    • 2011
  • 본 논문은 내진설계규정이 적용되지 않은 국내 철근콘크리트 학교 건물에 관한 해석적 연구이다. 일본의 내진진단과 비선형 정적 및 동적 해석을 통하여 대상 건축물의 내진 성능을 평가하였다. 일본의 내진진단 방법에 기초하여 철근 콘크리트 학교 건물의 부족한 내진 성능을 파악하였다. 또한, 횡하중을 받는 학교 건물의 내진거동이 해석적으로 평가되었다. 건축물의 내진 보강을 위하여 1,300kN의 내력을 받는 전단벽과 K형 가새골조가 사용되었다. 비선형 정적해석 결과, 보강에 의한 전단내력은 보강 전에 비하여 30%이상의 향상을 보이는 것으로 나타났으며, 전단벽 보강 시 최대 하중 이후에서 가새골조 보강에 비해 큰 강성저하를 나타내었다. 또한, 성능점 산정 결과에서 가새골조로 보강된 건축물이 전단벽으로 보강된 건축물에 비해 30% 이상의 변형능력을 보였다. 한편 비선형 동적해석의 시간이력해석 결과에서는 가새골조와 전단벽에 의해 보강된 건축물의 최대 변위가 보강량이 증가할수록 감소하는 경향을 나타내었다. 본 연구는 이 외에도 지진 지역에서의 건축물의 내진성능 향상을 위해 다양한 지반 조건과 지진파를 고려되어야 한다고 판단된다.

항만 구조물의 내진성능 향상을 위한 배면 지반의 보강방안에 관한 연구 (The Study on Improvement Methods for The Seismic Performance of Port Structures)

  • 김병일;홍강한;김진해;한상재
    • 한국지반신소재학회논문집
    • /
    • 제18권4호
    • /
    • pp.151-165
    • /
    • 2019
  • 본 연구에서는 저유동성 몰탈 채움을 통한 기존 항만 구조물의 내진성능 향상을 위해 시공 위치에 따라 4가지(자중증가, 활동력 감소 등) 보강방안을 제시하였으며, 이론적 방법 및 수치해석적 방법으로 보강 시 효과(안정성, 시공성, 경제성)를 분석하여 최적 방안을 제시하였다. 본 연구 결과 인공지진파를 적용한 동적 시간이력해석을 수행한 결과 보강 후 수평변위는 보강 전 수평변위에 비해 감소하였으나 보강 방안별 지진시 변위 억제 효과는 큰 차이가 없는 것으로 평가되었다. 강도감소법과 한계평형해석법을 적용하여 원호활동 파괴특성을 검토한 결과 수동말뚝 형태의 개량 방안이 다른 보강방법에 비해 안전성이 높은 것으로 평가되었다. 이는 보강체로 인해 활동 파괴면의 전단강도가 증가하였기 때문이다. 또한, 시공성 및 경제성을 분석한 결과 토압 저감형태(Type 02)와 수동말뚝 형태(Type 03)가 우수한 것으로 나타났다. 다만, 수동말뚝 형태의 경우, 설계법 적용 사례가 미미하고, 지반 조건에 따라 시공이 불가하거나 경제성이 급격히 저감되는 등 여러 가지 제약조건을 가지고 있어 적용시 주의가 요구된다.