• Title/Summary/Keyword: dynamic obstruction

Search Result 29, Processing Time 0.021 seconds

Regional Myocardial Blood Flow Estimation Using Rubidium-82 Dynamic Positron Emission Tomography and Dual Integration Method (Rubidium-82 심근 Dynamic PET 영상과 이중적분법을 이용한 국소 심근 혈류 예측의 기본 모델 연구)

  • 곽철은;정재민
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.223-230
    • /
    • 1995
  • This study investigates a combined mathematical model for the quantitative estimation of regional myocardial blood flow in experimental canine coronary artery occlusion and in patients with ischemic myocardial diseases using Rb-82 dynamic myocardial positron emission tomography. The coronary thrombosis was induced using the new catheter technique by narrowing the lumen of coronary vessel gradually, which finally led to partial obstruction of coronary artery. Thirty four Rb-82 dynamic myocardial PET scans were performed sequentially for each experiment using our 5, 10 and 20 second acquisition protocol, respectively, and six to seven regions of interest were drawn on each transaxial slices, one on left ventricular chamber for input function and the others on normal and decreased perfusion myocardial segments for the flow estimation in those regions. Two compartment model and graphical analysis method have been applied to the measured sets of regional PET data, and the rate constants of influx to myocardial tissue were calculated for regional myocardial flow estimates with the two parameter fits of raw data by the Levenberg-Marquardt method. The results showed that, (I) two compartment model suggested by Kety-Schmidt, with proper modification of the measured data and volume of distribution, could be used for the simple estimation of regional myocardial blood flow, (2) the calculated regional myocardial blood flow estimates were dependent on the selection of input function, which reflected partial volume effect and left ventricular wall motion in previously used graphical analysis, and (3) mathematically fitted input and tissue time activity curves were more suitable than the direct application of the measured data in terms of convergence.

  • PDF

Dynamic Programming Algorithm Path-finding for Applying Game (게임 적용을 위한 Dynamic Programming 알고리즘 길찾기)

  • Lee, Se-Il
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.4 s.36
    • /
    • pp.213-219
    • /
    • 2005
  • In order to move NPC's to target location at game maps, various algorithm including A* has been used. The most frequently used algorithm among them is A* with fast finding speed. But A* has the following problems. The first problem is that at randomly changing map, it is necessary to calculate all things again whenever there are any changes. And when calculation is wrong, it is not possible to search for target. The second problem is that it is difficult to move avoiding dangerous locations damaging NPC such as an obstruction. Although it is possible to avoid moving to locations with high weight by giving weight to dangerous factors. it is difficult to control in case NPC moves nearby dangerous factors. In order to solve such problems, in this thesis, the researcher applied Dynamic Programming to path-finding algorithm. As the result of its application, the researcher could confirm that the programming was suitable for changes at the map with random change and NPC's avoided the factors being dangerous to them far away. In addition. when compared to A*, there were good results.

  • PDF

Dual Stent Application on Congenital Tracheobronchial Stenosis - 1 case - (선천성 기관기관지 협착에서의 이중 스텐트의 적용 - 1례 보고 -)

  • 강문철;황성욱;김용진;김희수;김종성;성명훈
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.149-152
    • /
    • 2002
  • We report successful application of dual trachcobronchial stcnt to the diffuse tracheal stenosis. An one-month-old boy was transferred to the emergency room due to tachypnea and respiratory difficulty with COB retention. Preoperative computed tomography revealed pulmonary artery sling with diffuse tracheal stenosis. We found that the diameter of the both main bronchus was less than 3mm and the trachea was a complete ring. We divided the left pulmonary artery and implanted it to the main pulmonary artery under cardiopulmonary bypass. After that, tracheoplasty was performed with autologous pericardium. However, after the initial measures, CO2 retention and respiratory difficulty persisted due to the granulation tissue and dynamic obstruction of the airway ensued by the overlying pericardial flap. Therefore, we decided to apply a single tracheal stunt. After the insertion of tracheal stent, residual stenosis of the both main bronchus opening continued to cause respiratory difficulty Finally we applied dual tracheobronchial stent and resolved the airway obstruction.

Imaging diagnosis of clonorchiasis

  • Choi, Don-Gil;Hong, Sung-Tae
    • Parasites, Hosts and Diseases
    • /
    • v.45 no.2 s.142
    • /
    • pp.77-85
    • /
    • 2007
  • Among several diagnostic tools for clonorchiasis (Clonorchis sinensis infection), radiologic examinations are commonly used in clinical practices. During the 2 past decades, many reports regarding imaging findings of clonorchiasis were introduced. The basic imaging finding of clonorchiasis is diffuse dilatation of the peripheral intra-hepatic bile ducts, without dilation of the large intrahepatic or extrahepatic bile ducts. By this finding, however, active clonorchiasis cannot be differentiated from cured infection. Some recent radiologic studies suggested specific findings of active clonorchiasis. Besides direct demonstration of worms, increased periductal echogenicity on sonography and periductal enhancement on dynamic contrast-enhanced CT or MR imaging possibly represent active clonorchiasis. Those images of the liver clonorchiasis are known to be correlated with worm burdens (EPG counts) in their frequency and also severity. The images of cholangiocarcinoma associated with clonorchiasis show both the tumor with obstruction images and diffuse dilatation of the peripheral intrahepatic bile ducts. Radiological images can be a good practical alternative diagnostic method of clonorchiasis.

A Study on the Estimation of Regional Myocardial Blood Flow in Experimental Canine Model with Coronary Thrombosis using Rb-82 Dynamic Myocardial Positron Emission Tomography (실험 개에서 Rb-82 심근 Dynamic PET 영상을 이용한 국소 심근 혈류 예측의 기본 모델 연구)

  • Kwark, Cheol-Eun;Lee, Dong-Soo;Kang, Keon-Wook;Hwang, Eun-Kyung;Jeong, Jae-Min;Chang, Kee-Hyun;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.48-53
    • /
    • 1995
  • This study investigates a simple mathematical model for the quantitative estimation of regional myocardial blood flow in experimental canine coronary artery thrombosis using Rb-82 dynamic myocardial positron emission tomography. The coronary thrombosis was induced using the new catheter technique by narrowing the lumen of coronary vessel gradually, which finally led to partial obstruction of coronary artery. Ten Rb-82 dynamic myocardial PET scans were performed sequentially for each experiment using our 5, 10 and 20 second acquisition protocol, respectively, and three regions of interest were drawn on the transaxial slices, one on left ventricular chamber for input function and the other two on normal and decreased perfusion segments for the flow estimation in those regions. Single compartment model has been applied to the measured sets of regional PET data, and the rate constants of influx to myocardial tissue were calculated for regional myocardial flow estimates with the three parameter fits of raw data by the Levenberg-Marquardt method. The results showed that, (1) single compartment model suggested by Kety-Schmidt could be used for the simple estimation of regional myocardial blood flow, (2) the calculated regional myocardial blood flow estimates were dependent on the selection of input function, which reflected partial volume effect and left ventricular wall motion, and (3) mathematically fitted input and tissue time activity curves were more suitable than the direct application of the measured data in terms of convergence.

  • PDF

Successful High Flow Nasal Oxygen Therapy for Excessive Dynamic Airway Collapse: A Case Report

  • Park, Jisoo;Lee, Yeon Joo;Kim, Se Joong;Park, Jong Sun;Yoon, Ho Il;Lee, Jae Ho;Lee, Choon-Taek;Cho, Young-Jae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.4
    • /
    • pp.455-458
    • /
    • 2015
  • Excessive dynamic airway collapse (EDAC) is a disease entity of excessive reduction of the central airway diameter during exhalation, without cartilage collapse. An 80-year-old female presented with generalized edema and dyspnea at our hospital. The patient was in a state of acute decompensated heart failure due to pneumonia with respiratory failure. We accordingly managed the patient with renal replacement therapy, mechanical ventilation and antibiotics. Bronchoscopy confirmed the diagnosis of EDAC. We scheduled extubation after the improvement of pneumonia and heart condition. However, extubation failure occurred due to hypercapnic respiratory failure with poor expectoration. Her EDAC was improved in response to high flow nasal oxygen therapy (HFNOT). Subsequently, the patient was stabilized and transferred to the general ward. HFNOT, which generates physiologic positive end expiratory pressure (PEEP) effects, could be an alternative and effective management of EDAC. Further research and clinical trials are needed to demonstrate the therapeutic effect of HFNOT on EDAC.

Two-Dimensional Model for the Prediction of Inundation Area in Urbanized Rivers (도시하천에서의 홍수범람도 작성을 위한 2차원 모형의 개발)

  • 한건연;박재홍
    • Water for future
    • /
    • v.28 no.6
    • /
    • pp.119-131
    • /
    • 1995
  • Two-dimensional diffusion and kinematic hydrodynamic models have been studied for preparing the flood inundation map. The models have been tested by applying to one-dimensional dam-break problem. The results have good agreements compared with those of dynamic wave model. The diffusion wave model produces the mass conservation error close to zero. Floodwave analyses for two-dimensional floodplain with obstruction and channel-floodplain show both stable and efficient results. The model presented in this study can be used for flood inundation map and flood warning system.

  • PDF

Speed Control of PIG Flow in Natural Gas Pipeline (천연가스배관 내 피그흐름의 속도제어)

  • Nguyen, Tan Tien;Kim, Dong-Kyu;Rho, Yong-Woo;Kim, Sang-Bong
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.253-258
    • /
    • 2001
  • This paper introduces a simple nonlinear adaptive control method for pipeline inspection gauge (PIG) flow in natural gas pipeline. The dynamic behavior of the PIG depends on the different pressure across its body and the bypass flow through it. The system dynamics includes: dynamics of driving gas flow behind the PIG, dynamics of expelled gas in front of the PIG, and dynamics of the PIG. The method of characteristics (MOC) and Runger-Kuta method are used to solve the dynamics of flow. The PIG velocity is controlled through the amount of bypass flow across its body. A simple nonlinear adaptive controller based on the backstepping method is introduced. To derive the controller, three system parameters should be measured: the PIG position, its velocity and the velocity of bypass flow across the PIG body. The simulation has been done with a pipeline segment in the KOGAS low pressure system, Ueijungboo-Sangye line to verify the effectiveness of the proposed controller. Three cases of interest are considered: the PIG starts to move at its launcher, the PIG arrives at its receiver and the PIG restarts after stopping in the pipeline by obstruction. The simulation results show that the proposed nonlinear adaptive controller attained good performance and can be used for controlling the PIG velocity.

  • PDF

Surgical Treatment of Discrete Subaortic Stenosis (대동맥판막하 막상협착증의 수술요법)

  • No, Jun-Ryang;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.165-173
    • /
    • 1986
  • During the 4 year period from 1982 through 1985, twelve patients have undergone operations for discrete subaortic stenosis with good short-term clinical result at Department of Thoracic and cardiovascular Surgery, S.N.U.H. According to the cineangiographic and operative findings, nine of the 12 patients were classified as Deutsch type I, the other 3 as type II, and eleven of the 12 had one or more associated anomalies of the cardiovascular system such as PDA[5], VSD[5], left SVC[2], MS[1], COA[1], supramitral membrane[1], DORY[1], right aortic arch[1], DCRV[1], and TOF[1] [one with Shone`s complex], and three of them had secondary cardiac disorders such as aortic regurgitation[3],mitral regurgitation[2], and tunnel shaped dynamic obstruction of left ventricular outflow tract[2]. We have performed membrane resection via oblique aortotomy with retraction of the aortic cusps in 7 cases and via VSD from right cardiac chamber in 5 cases with large VSD and have also performed the operations on the correctable associated anomalies. There was only one operative death in patient with associated TOF due to neurologic complication and no other postoperative difficulties except in one patient with transient heart block resolved spontaneously on postoperative 3rd day. To our knowledge, this article is the first report of operation for discrete subaortic stenosis in Korean literature.

  • PDF

99mTc-DISIDA HEPATOBILIARY SCINTIGRAM IN EVALUATION OF CLONORCHIS SINENSIS INFESTATION IN ENDEMIC REGION (간흡충증 간염에서의 $^{99m}Tc-DISIDA$ 간담도스캔)

  • Yum, Ha-Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.2
    • /
    • pp.25-41
    • /
    • 1985
  • 간흡충증은 한국 및 동남아세아에 널리 분포되어 있는 중요한 풍토병의 하나로서 진단은 전통적으로 분변검사에 의존하여 오고 있다. 최근 들어 담관내 간흡충 및 이의 합병증의 진단을 위해 ERCP 및 contrast cholangiogram등이 시도되었으나 실제에 이용하기에는 많은 제약이 있다 하겠다. 저자는 간흡충증에 있어서 최근 소개된 $^{99m}Tc-DISIDA$ hepatobiliary scintigraphy의 진단적 의의를 규명하고자 1982년부터 1983년까지 고신의대 부속 복음병원에서 검진한 간흡충증 환자 90명을 대상으로 하여 $^{99m}Tc-DISIDA$ hepatobiliary scintigraphy와 formalin-ether 원침법에 의한 분변검사를 시행하였다. $^{99m}Tc-DISIDA$ scintigram소견은 간내 담관 bile flow 및 총수담관 bile flow defect, 그리고 간세포기능의 정도에 따라 자료를 분석하였고 그외 합병증의 진단은 병록 기록, 수술 소견, ERCP 등에 의존하여 결론을 얻었다. $^{99m}Tc-DISIDA$ scintigraphy는 특이한 양상의 bile flow dynamics를 나타내었으며 간내 주담관의 intermittent irregular focal bile flow defect 및 tile flow stasis를 나타내고 말초담관의 bile flow defect는 경미하고 60분 내에 담관 bile flow activity의 완전한 배설을 나타내는 경우를 mild pattern, 간내 담관의 심한 irregular bile flow dynamics 및 간내담관의 심한 irregularity (담관내벽의 심한 불규칙성), 총수담관, 간내 주담관 및 말초 담관까지 심하게 irregular bile flow stasis를 나타내며 bile flow activity의 완전 베설이 $60\sim90$분사이 혹은 90분이상까지 인지된 경우를 moderate-severe pattern으로 분류하였다. 1) 분변검사상 간흡충증은 95검사중 70검사(환자 86명중 67명)에서 양성을 보여 분변 충난검사의 양성율은 73.7%였고 음성율은 26.3%였다. 2) $^{99m}Tc-DISIDA$ hepatobiliary scintigraphy는 90명중 70명에서 특이한 Cs-bile flow양성을 보였으며 양성율은 77.8%였으며 음성율은 22.2%였다. 3) $^{99m}Tc-DISIDA$ hepatobiliary scintigram양성율을 나타낸 환자 70명중 11명은 mild pattern, 59명은 moderate-severe pattern을 나타냈으며 그중 21명은 여러가지 간세포 기능 및 담관에 영향을 미치는 질환과 합병했지만 특이한 Cs-bile flow pattern을 dominent하게 나타내었으며 합병된 여러 질환들도 bile flow pattern상 인지 할 수 있었다. 4) $^{99m}Tc-DISIDA$ hepatobiliary scintigram 음성율을 나타낸 환자 20명중 8명은 만성간염, 5명은 간경변증, 3명은 재발성 농양성담관염(recurrent pyogenic cholangitis)과 간내담도의 stricture 및 담관담석증이 합병되었으며 scintigram상 합병증의 pattern을 나타냈고 4명에서는 low CBD obstruction을 나타내었으며 후에 CBD stone, CBD carcinoma, gall bladder Ca.의 porta hepatis 전이 및 clonorchis worms의 cluster에 의한 obstruction이 operation 및 ERCP로서 진단 되었다. 5) $^{99m}Tc-DISIDA$ hepatobiliary scintigraphy pattern은 현재의 자각증상과 관계된 dominent disease를 나타내었으며, 공간 점유병소도 multiple project images를 시행하므로서 쉽게 발견할 수 있었다. 이와 같이 간흡충증에 있어서 $^{99m}Tc-DISIDA$ hepatobiliary scintigram은 환자의 자각증상과 관계된 질환을 규명하는 데 필요한 정보를 얻었을 수 있었으며 간내담관의 damage정도를 규명하는데 필요한 procedure임이 판명되었다.

  • PDF