• Title/Summary/Keyword: dynamic monitoring system

Search Result 554, Processing Time 0.023 seconds

Study on Advanced Frequency Estimation Technique using Gain Compensation

  • Park, Chul-Won;Shin, Dong-Kwang;Kim, Chul-Hwan;Kim, Hak-Man;Kim, Yoon-Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.439-446
    • /
    • 2011
  • Frequency is an important operating parameter for the protection, control, and stability of a power system. Thus, it must be maintained very close to its nominal frequency. Due to the sudden change in generation and loads or faults in a power system, however, frequency deviates from its nominal value. An accurate monitoring of the power frequency is essential for optimum operation and prevention of wide area blackout. Most conventional frequency estimation schemes are based on the DFT filter. In these schemes, the gain error could cause defects when the frequency deviates from the nominal value. We present an advanced frequency estimation technique using gain compensation to enhance the DFT filter-based technique. The proposed technique can reduce the gain error caused when the frequency deviates from the nominal value. Simulation studies are performed using both the data from EMTP-RV software and the user-defined arbitrary signals to demonstrate the effectiveness of the proposed algorithm. Results show that the proposed algorithm achieves good performance under both steady state tests and dynamic conditions.

A Study on the Moving Object Tracking Algorithm of Static Camera and Active Camera in Environment (고정카메라 및 능동카메라 환경에서 이동물체 추적 알고리즘에 관한 연구)

  • 남기환;배철수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.2
    • /
    • pp.344-352
    • /
    • 2003
  • An effective algorithm for implementation of which detects moving object from image sequences. predicts the direction of it. and drives the camera in real time is proposed. In static camera, for robust motion detection from a dynamic background scene, the proposed algorithm performs statistical modeling of moving objects and background, and trains the statistical modeling of moving objects and background, and trains the statistical feature of background with the initial parts of sequence which have no moving objects. Active camera moving objects are segmented by following procedure, an improved order adaptive lattice structured linear predictor is used. The proposed algorithm shows robust object tracking results in the environment of static or active camera. It can be used for the unmanned surveillance system, traffic monitoring system, and autonomous vehicle.

The Fault Diagnosis of Marine Diesel Engines Using Correlation Coefficient for Fault Detection (이상감지 상관계수를 이용한 선박디젤기관의 고장진단시스템에 관한 연구)

  • Kim, Kyung-Yup;Kim, Yung-Ill;Yu, Yung-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.1
    • /
    • pp.18-24
    • /
    • 2011
  • This paper proposes fault diagnosis system which is able to diagnose the fault from present operating condition by analyzing monitored signals with present ship monitoring system without additional sensors. For this all kinds of ship's engine room monitored data are classified with combustion subsystem, heat exchange subsystem and electric motor and pump subsystem by analyzing ship's operation data. To extract dynamic characteristics of these subsystems, log book data of container ship of H shipping company are used.

An Intelligent Human-Machine Interface for Next Generation Nuclear Power Plants

  • Park, Seong-Soo;Park, Jin-Kyun;Hong, Jin-Hyuk;Chang, Soon-Heung;Kim, Han-Gon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.191-196
    • /
    • 1995
  • The intelligent human-machine interface (HMI) has been developed to enhance the safety and availability of a nuclear power plant by improving operational reliability The key elements of the HMI are the large display panels which present synopsis of the plant status and the compact, digital work stations for the primary operator control and monitoring functions. The work station consists of four consoles such as a dynamic alarm console (DAC), a system information console (SIC), a computerized operating-procedure console (COC), and a safety related information console (SRIC). The DAC provides clean alarm pictures, in which information overlapping is excluded and alarm impacts are discriminated, for quick situation awareness. The SIC covers a normal operation by offering all necessary plant information and control functions. In addition, it is closely linked with the DAC and the COC to automatically display related system information under the request of these consoles. The COC aids the operator with proper emergency operation guidelines so as to shutdown the plant safely, and it also reduces his physical/mental burden by automating the operating procedures. The SRIC continuously displays safety related information to allow the operator to assess the plant status focusing on plant safety. The proposed HMI has been validated and demonstrated with on-line data obtained from the full-scope simulator for Yonggwang Units 1,2.

  • PDF

Online Strain Measurement at Multiple Points on a Rotating Blade with Fiber Bragg Grating Sensors and a Rotary Optical Coupler (광섬유 격자 센서와 회전 광학 커플러를 사용한 회전하는 블레이드 여러 지점에서의 온라인 변형률 측정)

  • Lee, Jong-Min;Hwang, Yo-Ha
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.1
    • /
    • pp.77-82
    • /
    • 2008
  • Strain-gauges have been dominantly used to measure strain at various points on a rotor, however, either a slip ring or telemetry has to be used to send sensor signals to data acquisition instruments at stationary side. Both slip ring and telemetry have numerous inherent problems which force severe limitations in real applications. This paper introduces a new rotor condition monitoring system using FBG(Fiber Bragg Grating) sensors and a rotary optical coupler. A single optical fiber with many FBG sensors is installed on the rotor and an optical dynamic interrogator is installed at stationary side. The sensor signal connection between rotating part and stationary part is made by the rotary optical coupling method which makes use of light's unique characteristic-light travels through space. Broad band light source from the interrogator travels to the optical fiber on the rotor and reflected FBG sensor signals travel back to the optical fiber on stationary side and are connected to the interrogator. Rotary optical coupler's insertion loss change due to rotation is compensated by using a reference sensor installed at the center of the rotor. The proposed system's performance has been successfully demonstrated by accurately measuring strains at 5 points on a blade rotating at high speed.

JsSandbox: A Framework for Analyzing the Behavior of Malicious JavaScript Code using Internal Function Hooking

  • Kim, Hyoung-Chun;Choi, Young-Han;Lee, Dong-Hoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.2
    • /
    • pp.766-783
    • /
    • 2012
  • Recently, many malicious users have attacked web browsers using JavaScript code that can execute dynamic actions within the browsers. By forcing the browser to execute malicious JavaScript code, the attackers can steal personal information stored in the system, allow malware program downloads in the client's system, and so on. In order to reduce damage, malicious web pages must be located prior to general users accessing the infected pages. In this paper, a novel framework (JsSandbox) that can monitor and analyze the behavior of malicious JavaScript code using internal function hooking (IFH) is proposed. IFH is defined as the hooking of all functions in the modules using the debug information and extracting the parameter values. The use of IFH enables the monitoring of functions that API hooking cannot. JsSandbox was implemented based on a debugger engine, and some features were applied to detect and analyze malicious JavaScript code: detection of obfuscation, deobfuscation of the obfuscated string, detection of URLs related to redirection, and detection of exploit codes. Then, the proposed framework was analyzed for specific features, and the results demonstrate that JsSandbox can be applied to the analysis of the behavior of malicious web pages.

Dynamic Yield Improvement Model Using Neural Networks (신경망을 이용한 동적 수율 개선 모형)

  • Jung, Hyun-Chul;Kang, Chang-Wook;Kang, Hae-Woon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.2
    • /
    • pp.132-139
    • /
    • 2009
  • Yield is a very important measure that can expresses simply for productivity and performance of company. So, yield is used widely in many industries nowadays. With the development of the information technology and online based real-time process monitoring technology, many industries operate the production lines that are developed into automation system. In these production lines, the product structures are very complexity and variety. So, there are many multi-variate processes that need to be monitored with many quality characteristics and associated process variables at the same time. These situations have made it possible to obtain super-large manufacturing process data sets. However, there are many difficulties with finding the cause of process variation or useful information in the high capacity database. In order to solve this problem, neural networks technique is a favorite technique that predicts the yield of process for process control. This paper uses a neural networks technique for improvement and maintenance of yield in manufacturing process. The purpose of this paper is to model the prediction of a sub process that has much effect to improve yields in total manufacturing process and the prediction of adjustment values of this sub process. These informations feedback into the process and the process is adjusted. Also, we show that the proposed model is useful to the manufacturing process through the case study.

The Strategy of Switching to Global Digital by OEM Companies in Jeonlabuk-do (전라북도 OEM업체들의 Global Digital Switch 전략)

  • Choi, Heung-Seob;Lee, Sook-Ja
    • International Commerce and Information Review
    • /
    • v.6 no.1
    • /
    • pp.157-189
    • /
    • 2004
  • Recently, Digital Switch has risen as one of the important issues on which academic and industrial world focus in order to bring organizational transformation to a company that wants to adapt itself to the rapidly changing business environment. However, the discussion in the Digital Switch has been so much concentrated in the study of each static system, model of their performance and the development of monitoring each of them, that only few theoretical research has been carried out on the dynamic process of how each system in the organization experienced the change in terms of the level of digital transformation that can occur in the whole organization facing the change of digital environment. Therefore this thesis aims to develop a new model & strategy of switching to global digital by OEM companies in Jeonlabuk-do that enables us to check out and predict the Digital Switch progress. This model is the first Digital Switch process evaluation intended for empirical study, especially by integrating the many indices that have not been examined empirically by the existing studies. We expect that the results from this research will help corporate e-business strategy planners to devise and analyze the Digital Switch strategies effectively by recognizing the companies' current situation in comparison with their previous and other firms' level, respectively.

  • PDF

Development of a Portable SpO2-based Biosignal Monitoring System (SpO2 기반 휴대형 생체 신호 모니터링 시스템 개발)

  • Lee, Hyung-Bong;Park, Sung-Wook;Chung, Tae-Yun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.5
    • /
    • pp.273-283
    • /
    • 2013
  • The traditional medical equipments are devices used by medical professionals but not used in public environment. Common people, however, require light-weight medical devices to make healthcare for themselves nowadays. Those medical devices are used to monitor personal health status such as blood pulse, blood pressure, diabetes. Also, some of them are operated in mobile environment called u-healthcare. This paper implements a portable healthcare system composed of $SpO_2$(Saturation of Partial Pressure Oxygen) sensors and a gateway for detecting hypoxemia during people's leasure activity such as climbing or hiking. The $SpO_2$ sensor is designed as watch style to support dynamic exercise and the gateway is designed as necklace style to support the elderly. The result of a performance evaluation shows that the performance of the $SpO_2$ sensor using reflection technology is not lower than that of a clairvoyant styled $SpO_2$ sensor.

Field measurements of wind-induced transmission tower foundation loads

  • Savory, E.;Parke, G.A.R.;Disney, P.;Toy, N.;Zeinoddini, M.
    • Wind and Structures
    • /
    • v.1 no.2
    • /
    • pp.183-199
    • /
    • 1998
  • This paper discusses some of the findings arising from long-term monitoring of the wind effects on a transmission tower located on an exposed site in South-West England. Site wind speeds have been measured, together with the foundation loads at the base of each of the four legs. The results show good correlation between the wind speeds and leg strains (loads) for a given wind direction, as expected, for wind speeds in excess of 10 m/s. Comparisons between the measured strains and those determined from the UK Code of Practice for lattice towers (BS8100), for the same wind speed and direction, show that the Code over-estimates most of the measured foundation loads by a moderate amount of about 14% at the higher wind speeds. This tends to confirm the validity of the Code for assessing design foundation loads. A finite element analysis model has been used to examine the dynamic behaviour of the tower and conductor system. This shows that, in the absence of the conductor, the tower alone has similar natural frequencies of approximately 2.2 Hz in the both the first (transversal) and second (longitudinal) modes, whilst for the complete system and conductor oscillations dominate, giving similar frequencies of approximately 0.1 Hz for both the first and second modes.