• 제목/요약/키워드: dynamic filtration

Search Result 42, Processing Time 0.024 seconds

Seismic resilience evaluation of RC-MRFs equipped with passive damping devices

  • Kamaludin, Puteri Nihal Che;Kassem, Moustafa Moufid;Farsangi, Ehsan Noroozinejad;Nazri, Fadzli Mohamed;Yamaguchi, Eiki
    • Earthquakes and Structures
    • /
    • 제18권3호
    • /
    • pp.391-405
    • /
    • 2020
  • The use of passive energy dissipation devices has been widely used in the construction industry to minimize the probability of damage occurred under intense ground motion. In this study, collapse margin ratio (CMR) and fragility curves are the main parameters in the assessment to characterize the collapse safety of the structures. The assessment is done on three types of RC frame structures, incorporating three types of dampers, viscoelastic, friction, and BRB dampers. The Incremental dynamic analyses (IDA) were performed by simulating an array of 20 strong ground motion (SGM) records considering both far-field and near-field seismic scenarios that were followed by fragility curves. With respect to far-field ground motion records, the CMR values of the selected frames indicate to be higher and reachable to safety margin more than those under near-field ground motion records that introduce a high devastating impact on the structures compared to far-field excitations. This implies that the near field impact affects the ground movements at the site by attenuation the direction and causing high-frequency filtration. Besides that, the results show that the viscoelastic damper gives better performance for the structures in terms of reducing the damages compared to the other energy dissipation devices during earthquakes.

신장 질환이 있는 소아에서 $^{99m}$Technetium-mercaptoacetyltriglycine ($^{99m}Tc$-MAG3) 신장 스캔에 의한 사구체 여과율 측정 (Glomerular Filtration Rate Measurements Using $^{99m}$Technetium-mercaptoacetyltriglycine Dynamic Renal Scintigraphy in Children with Renal Disease)

  • 윤인애;윤기욱;임인석;최응상;유병훈
    • Childhood Kidney Diseases
    • /
    • 제17권2호
    • /
    • pp.57-64
    • /
    • 2013
  • 목적: 소아에서 24시간 소변 수집의 단점을 대체하기 위해 $^{99m}Tc$-MAG3 신장 스캔을 통한 신기능을 측정하여, 크레아티닌 청소율과 혈청 cystatin C과 크레아티닌에 의한 사구체 여과율 추정식을 비교하여 연관성을 확인하였다. 방법: 2011년 7월부터 2012년 8월까지 101명의 18세 미만의 환자들을 대상으로 의무기록 후향적 조사로 실시하였고 $^{99m}Tc$-MAG3 신장 스캔을 시행하여 사구체 여과율을 측정하였다. 24시간 소변과 혈액을 체취하여 크레아티닌 청소율을 측정하였고 5개의 추정식을 통해 사구체 여과율을 측정하였다. 결과: 크레아티닌 청소율과 $^{99m}Tc$-MAG3 신장 스캔을 이용한 사구체 여과율의 Pearson 상관 계수는 0.389(P<0.001)이었다. $^{99m}Tc$-MAG3 신장 스캔과 Schwartz 식, Counahan-Barratt 식, MDRD 식, Cockcroft-Gault 식, Filler and Lepage 식, Bokencamp 식에 의한 사구체 여과율의 Pearson 상관 계수는 각각 0.265 (P=0.007), 0.128(P=0.044), 0.216 (P=0.030), 0.230 (P=0.021), 0.356 (P<0.001), 0.355 (P<0.001) 로 확인되었다. 사구체 및 비사구체 신질환의 비교에서 $^{99m}Tc$-MAG3 신장 스캔에 의한 사구체 여과율은 모두 유의한 상관성을 가졌고, 신기능의 저하 유무에 상관없이 $^{99m}Tc$-MAG3 신장 스캔에 의한 사구체 여과율은 크레아티닌 청소율과 유의한 연관성을 보였다. 결론: 크레아티닌 청소율과 $^{99m}Tc$-MAG3 신장 스캔에 의한 사구체 여과율 간에는 유의한 상관성이 있으며 $^{99m}Tc$-MAG3 신장 스캔에 의한 사구체 여과율은 신질환의 기원과 신기능의 정상 여부 모두에서 크레아티닌 청소율을 대체할 수 있는 방법임을 확인할 수 있었다. $^{99m}Tc$-MAG3 신장 스캔 이용 시 정확하고 빠른 결과를 얻을 수 있으리라 생각된다.

전기응집 분리 막 생물반응기의 막 오염 저감 (Membrane fouling reduction using electro-coagulation aided membrane bio-reactor)

  • 김완규;홍성준;장인성
    • 한국산학기술학회논문지
    • /
    • 제19권8호
    • /
    • pp.105-114
    • /
    • 2018
  • 전기응집 (Electro-coagulation)을 활용한 분리 막 생물반응기 (Membrane Bio-Reactor) 공정의 막 오염 저감 현상을 확인하고 이를 해석하고자 하였다. 전기응집의 주요 운전 인자인 전류밀도와 접촉시간 변화가 활성슬러지 혼합액의 막 여과에 미치는 영향을 관찰하고 전기응집 과정에서 발생하는 수산화금속염이 막 오염에 미치는 역할에 대해 연구하였다. 전류밀도를 $10A/m^2$으로 높게 유지한 경우에는 전기응집 시간이 증가하여도 막 오염 감소 효과가 크지 않은 반면 $2.5A/m^2$의 낮은 전류밀도 하에서는 전기응집 시간이 증가하면 추가적인 막 오염 감소가 관찰되었다. 즉, 막 오염을 감소시키는 전류밀도와 접촉시간의 곱이 전체 막 오염 저감 정도를 지배하고 있음을 확인하였다. 또한 주어진 전류밀도와 인가시간에서 입도분포는 크게 변화하지 않은 것으로 나타나 콜로이드 입자와 막 오염 저감과는 큰 관련성이 없는 것으로 판단되었다. 그러나 전기응집을 통해 생성된 수산화알루미늄 (인산알루미늄)이 막 여과 과정에서 동적 막 (Dynamic Membrane)을 형성하여 막 오염 현상을 완화하는 것으로 확인되었다. 전기응집에서 발생한 수산화금속염이 막 표면에 동적 막을 형성하고 이로 인해 유입수의 입자성분이 직접 막 표면과 내부에 침적되는 것을 방해하고 동적 막에 주로 쌓이게 함으로써 막 오염이 감소된 것이다. 본 연구에서 밝힌 수산화금속염에 의한 동적 막의 역할은 전기응집을 활용한 MBR 공정의 후 막 오염 감소 메커니즘을 해석하는데 중요한 역할을 한다고 결론지을 수 있다.

RENAL REGULATION OF UREA EXCRETION IN SWAMP BUFFALO FED WITH HIGH PROTEIN SUPPLEMENTATION

  • Chaiyabutr, N.;Chanpongsang, S.;Loypetjra, P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제8권3호
    • /
    • pp.275-280
    • /
    • 1995
  • The effect of supplemented high protein diet intake on renal urea regulation in swamp buffalo was carried out in the present experiment Five swamp buffalo heifers weighing between 208-284 kg were used for this study. The animals were fed with a supplementary high protein diet and renal function and kinetic parameters for urea excretion were measured. This was compared to a control period where the same animals had been fed only with paragrass and water hyacinth. For 2 months the same animals were fed a mixed of paragrass, water hyacinth plus 2 kgs of a high protein supplement (protein 18.2% DM basis) per head per day. In comparison to the control period, there were no differences in the rate of urine flow, glomerular filtration rate (GFR), effective renal plasma flow (ERPF), plasma urea concentration and filtered urea. In animals supplemented with high protein intake mean values of urea clearance, excretion rate and the urea urine/plasma concentration ratio markedly increased (p < 0.05) while renal urea reabsorption significantly decreased from 40% to 26% of the quantity filtered. In this same study group urea space distribution and urea pool size increased which coincided with an increase in plasma volume (p < 0.05). Plasma protein decreased while plasma osmolarity increased (p < 0.05). Both urea turnover rate and biological half-life of $^{14}C$-urea were not affected by a supplementary high protein intake. The results suggest that animals supplemented with high protein diets are in a state of dynamic equilibrium of urea which is well balanced between urea excreted into the urine and the amount synthesized. The limitation for renal tubular urea reabsorption would be a change in extra-renal factors with an elevation of the total pool size of nitrogenous substance.

역충격형 중공사모듈의 동특성 연구 (Dynamic Characterization of Backpulsing Hollow Fiber Module System)

  • 노수홍;박상현;장진호
    • 멤브레인
    • /
    • 제11권1호
    • /
    • pp.14-21
    • /
    • 2001
  • 막오염을 줄이기 위해 고빈도 역충격 시스템을 적용한 새로운 분리막 모듈을 연구하였다. 폴리아크릴로니트릴(Polyacrilonitrile) 재질의 외경 1.4mm, 내경 0.9mm, 분획분자량 50,000인 한외여과막과 라텍스(latex)용액을 사용하여 실험하였다. 역충격을 중공사막에 적용했을 때 제안된 모델식에 의한 이론치와 실험치를 비교 분석하였고, 역충격을 적용했을 때와 하지 않았을 때의 경우를 비교하였다. 이론치를 계산하기 위해 비저항 계수(specific cake resistance), 케익성장시간상수(time constant for cake growth), 확산계수(diffusion coefficient), 그리고 4가지 오염모델의 속도상수를 구하였다. 고빈도의 역충격을 가한 모듈의 투과율은 역충격이 없을 때의 투과율보다 약 40∼120%가 증가하였고 모델을 이용한 예상값과 1∼14% 내의 오차 범위를 나타냈다. 최적 역충격 세기는 20∼40%의 범위에서 20%였고 최적 역충격 빈도수는 0.67∼3Hz 범위에서 2Hz로 나타났다.

  • PDF

Modelling of starch industry wastewater microfiltration parameters by neural network

  • Jokic, Aleksandar I.;Seres, Laslo L.;Milovic, Nemanja R.;Seres, Zita I.;Maravic, Nikola R.;Saranovic, Zana;Dokic, Ljubica P.
    • Membrane and Water Treatment
    • /
    • 제9권2호
    • /
    • pp.115-121
    • /
    • 2018
  • Artificial neural network (ANN) simulation is used to predict the dynamic change of permeate flux during wheat starch industry wastewater microfiltration with and without static turbulence promoter. The experimental program spans range of a sedimentation times from 2 to 4 h, for feed flow rates 50 to 150 L/h, at transmembrane pressures covering the range of $1{\times}10^5$ to $3{\times}10^5Pa$. ANN predictions of the wastewater microfiltration are compared with experimental results obtained using two different set of microfiltration experiments, with and without static turbulence promoter. The effects of the training algorithm, neural network architectures on the ANN performance are discussed. For the most of the cases considered, the ANN proved to be an adequate interpolation tool, where an excellent prediction was obtained using automated Bayesian regularization as training algorithm. The optimal ANN architecture was determined as 4-10-1 with hyperbolic tangent sigmoid transfer function transfer function for hidden and output layers. The error distributions of data revealed that experimental results are in very good agreement with computed ones with only 2% data points had absolute relative error greater than 20% for the microfiltration without static turbulence promoter whereas for the microfiltration with static turbulence promoter it was 1%. The contribution of filtration time variable to flux values provided by ANNs was determined in an important level at the range of 52-66% due to increased membrane fouling by the time. In the case of microfiltration with static turbulence promoter, relative importance of transmembrane pressure and feed flow rate increased for about 30%.

수지상세포 활성화를 위한 세포투과 펩타이드가 결합된 재조합 전립성 산성 인산분해효소의 정제 (Purification of Recombinant CTP-Conjugated Human prostatic acid phosphatase for activation of Dendritic Cell)

  • 이기완;류강
    • KSBB Journal
    • /
    • 제24권1호
    • /
    • pp.80-88
    • /
    • 2009
  • glandular kallikrein에 광범위한 상동성을 가지는 인간 전립성 산성 인산 가수분해 효소는, 전립선암의 대표적인 혈청 biomarkers이다. 수지상세포는 유력한 항원 제시 세포이며, 바이러스, 미생물 병원체 및 종양에 대하여 면역 계통에서 강력한 T 세포 응답을 유도할 수 있다. 따라서, 종양 특이적인 항원으로 감작된 수지상세포를 이용한 면역요법은 anti-tumor 면역 유도를 위한 강력한 방법중의 하나이다. 크레아젠(주)에서 개발된 CTP (세포막 투과성 펩티드) 기술은 세포 내로의 높은 침투 효율성을 가지며 핵산이나 단백질과 같은 생체 고분자 물질을 접합하여 세포내로 수송할 수 있는 기술이다(36). 하지만 활성형의 인간 전립성 산성 인산 가수분해 효소는 세포사멸을 매개할 수 있기 때문에, 본 연구진은 항암 치료용 백신으로의 수지상세포 감작을 위해 비활성형 형태의 다중체 (multimer) 항원을 개발하였다. 본 연구에서, 수지상 세포의 감작과 활성화에 안전하고 효율적인 다중체 형태 (multimeric form)의 세포막 투과성 펩티드가 융합된 인간 전립성 산성 인산 가수분해 효소를 얻기 위한 정제공정을 기법을 개발하였고 젤 여과 크로마토그래피, western blot과 Dynamic Light Scattering을 이용하여 확인하였다. 아울러, 정제된 다중체 형태 (multimeric form)의 세포막 투과성 펩티드가 융합된 인간 전립성 산성 인산 가수분해 효소는 수지상 세포의 감작시 세포질 내로 효과적으로 침투되었다. 결과적으로 세포의 사멸의 부작용이 없이 MHC class I 분자를 통해 수지상세포의 표면으로 효과적으로 제시되었다.

핵의학 영상의 정량적 분석을 통한 신장기능 평가 프로그램 개발 (Development of Program for Renal Function Study with Quantification Analysis of Nuclear Medicine Image)

  • 송주영;이형구;서태석;최보영;신경섭;정용안;김성훈;정수교
    • 대한핵의학회지
    • /
    • 제35권2호
    • /
    • pp.89-99
    • /
    • 2001
  • 목적: 감마카메라로부터 획득한 신장 영상의 정량적 분석을 통해 신장 기능 평가시 사용되고 있는 기존 상용 프로그램은 사용자 임의의 기능 변경 및 추가가 어려워 응용적 측면에서 단점을 갖고 있다. 이 연구에서는 이러한 기존 상용프로그램의 단점을 극복하고, 사용자가 임상 필요에 따라 기능 변경 및 추가를 쉽게 할 수 있는 분석 프로그램을 개발하여 그 결과의 타당성을 분석하였다. 대상 및 방법: 개발된 프로그램은 IDL5.2를 사용하여 작성하였으며, windows운영시스템의 일반 개인용 컴퓨터에서 구현토록 하였다. 프로그램의 기본 성능 구현 및 사구체여과율 계산값의 타당성 검증을 위한 영상자료를 얻기 위해 10명의 정상인을 대상으로 $^{99m}Tc$-DTPA 방사성의약품을 사용하였고, 평균통과시간 계산값의 타당성 검증을 위한 영상자료를 얻기 위해 정상인 11명의 22개의 신장을 대상으로 $^{99m}Tc$-DTPA와 $^{99m}Tc$-MAG3를 사용하여 수분공급에 따른 평균통과시간 분석을 시행하였다. 신장영상은 Siemens사의 단일헤드 감마카메라(ORBITOR)를 통해 획득하였다. 정량적 분석을 위한 관심영역 설정은 수동설정 외에 자동설정 기능도 함께 개발하여 구현토록 하였다. 사구체여과율 계산을 위해 Gates방법을 사용하였고, 평균통과시간 계산을 위해 역중첩 방법과 적합한 여과 방법을 적용하여 안정된 값을 구하였다. 결과: 개발한 프로그램으로 시간별 신장영상과 각 관심영역 내에서의 시간방사능곡선을 도시할 수 있었고, 사구체여과율, 평균통과시간 및 좌 우 신장의 상대적 기능 외에 각 관심영역에서 최대방사능도달시간($T_{max}$)과 중간방사능도달시간($T_{1/2}$)과 같은 시간방사능곡선과 관련된 값들도 함께 계산하였다. 10명의 신장 영상 자료를 대상으로 개발된 프로그램으로 분석한 값들과 Siemens사의 기존 상용 분석 프로그램(MPE)으로 계산한 값들을 서로 비교, 분석한 결과, 통계학적으로 차이가 없음(최대 방사능도달시간: p=0.68, 상대신장기능: p=1.0, 사구체여과율: p=0.25)을 보여 개발한 프로그램이 타당성이 있음을 입증하였다. 평균통과시간 계산값의 타당성 검토와 관련하여, Siemens사의 상용 분석 프로그램에는 해당 기능이 없어 계산값의 비교를 통한 검증은 수행하지 못하였고, 수화(hydration)와 탈수(dehydration) 각각의 조건에 따른 신장기능 분석에 적용하였을 때, 판별 기준이 되는 유의미한 값을 산출하여 타당성 검증을 대신하였다. 결론: 이 연구에서 개발한 핵의학 영상의 정량적 분석을 통한 신장기능 분석 프로그램을 사용하여 신장 기능을 분석한 결과, 타당성 있는 결과를 도출하여 그 유용성을 입증하였다. 이 개발 프로그램은 좀 더 다양한 임상응용 목적의 분석기능을 사용자가 직접 개발, 추가하기가 용이하여 기존 상용 프로그램보다 연구적 활용범위가 크다고 사료된다.

  • PDF

신장 Depth 측정 방법에 따른 GFR 값의 최적화 (Optimization of GFR value according to Kidney Depth Measurement Methods)

  • 권형진;문일상;노경운;강건욱
    • 핵의학기술
    • /
    • 제23권2호
    • /
    • pp.25-28
    • /
    • 2019
  • GFR 검사는 신장의 기능을 평가하는 지표이다. 정확한 진단을 위해서 GFR 값은 상당히 중요하다. 체내검사와 체외검사 GFR 값을 비교하였고, 모든 GFR 값 기준은 체외검사로 하였다. 성인 환자 30명을 대상으로 하였다. 정상적인 위치에 신장이 있는 환자 27명과 특이한 위치에 신장이 있는 환자 3명(1. 선천적 신장 기형 환자, 2. 신장 이식 환자, 3. 마제형 신장 환자)을 대상으로 하였다. 검사 장비로는 GE Healthcare Infinia Hawkeye SPECT를 사용하였다. 체내검사 방법은 검사 30분전 물 $500m{\ell}$를 드시게 하였고, 환자 table과 detector 1, 2의 거리를 32 cm으로 하였고, $^{99m}Tc-DTPA$ 555 MBq으로 전체 주사기 계수(full syringe counts)를 측정한 후 신장 동적검사를 하였다(flow-1분, clearance-20분). 그리고 빈 주사기 계수(empty syringe counts)를 측정하였고, 3가지 방법(1. tonnensen 2. taylor 3. manual)으로 신장의 깊이를 측정하여 GFR 값을 구하였다. 모든 GFR 값은 gates method로 구하였다. 체외검사는 채혈을 통해서 GFR 값을 구하였다. 정상적인 위치에 있는 환자들의 경우는 체내검사와 체외검사의 GFR 값은 유의미한 차이가 없었다 (p> 0.05). 하지만 특이한 위치에 신장이 있는 환자의 경우는 수동(manual)방법으로 신장의 깊이를 측정하여 구한 GFR 값이 체외검사 GFR 값과 상당히 비슷하게 나왔고, 편차는 다음과 같다(1.선천적 신장 기형 환자: 6.4%, 2. 신장 이식 환자: 22.0%, 3번째 마제상 신장 환자: 2.0%). 그러므로 정상적인 위치에 신장이 있는 성인 환자들에 대해서는 어떤 방법으로 신장의 깊이를 이용하여 구하여도 체외검사 GFR 값과 유의미한 차이는 없었고, 특이한 위치에 신장이 있는 환자들에 대해서는 수동방법으로 신장의 깊이를 측정하여 GFR 값을 구하는 것이 가장 효과적이라고 사료된다.

Imaging Plate를 이용한 의료용 광자선의 선량측정 (Application of an imaging plate to relative dosimetry of clinical x-ray beams)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.117-122
    • /
    • 2000
  • 해상도가 뛰어나며 디지털영상으로 저장하므로 공간에 제약을 받지 않으며 재사용이 가능하다는 장점으로 현재 국내 병원에서는 Imaging Plate(IP)가 필름을 대체해가고 있는 추세에 있다. 본 연구는 진단용으로 사용되는 If를 이용하여 치료영역에서 선량측정용도로의 가능성 여부를 알아보고자 하였다. 실험을 하는데 사용되었던 IP는 Fuji사의 ST-V$_{A}$라는 모델이고 가속기는 Varian 2100C의 6 MV 광자선을 사용하였다. 먼저 전리함으로 측정한 심부선량을 기준으로 If로 측정한 값과 비교를 하였다. 조사문 선량(portal dose)을 측정하기 위하여 SSD=100 cm 위치에 두께 14 cm 되는 폴리스틸렌 팬텀을 놓고 그 밑에 전자포탈영상기구(Electronic Portal Imaging Device: EPID)가 위치한 지점에서 상대적 흡수선량(Off Axis Ratio: OAR)을 측정 그리고 계산하였다. 이때 전리함, 필름(Kodak X-Omat V) 및 IP를 전자포탈영상기구와 같은 위치에 놓고 측정을 하였고 이에 더하여 EGS4 몬테칼로전산모사를 통하여 조사문 선량을 계산하였다. 심부선량(PDD)을 측정한 결과 IP는 BaFBr:Eu$^{2+}$의 인광물질로 이루어져 있기 때문에 물보다 전자밀도가 높아 산란선에 매우 민감함을 알 수 있었다. 따라서 현재 진단영역에서 사용되고있는 IP는 심부선량측정계로는 적합하지 않다. 그러나 IP는 반음영외부부분(outside penumbra)을 제외한 조사문 선량측정에 비교적 정확한 것으로 밝혀졌다 또한 IP를 치료위치 확인용으로 사용할 수 있을 것으로 기대된다.

  • PDF