• Title/Summary/Keyword: dye laser

Search Result 208, Processing Time 0.031 seconds

A Spatio-Temporal Density Measurement of NO Molecules in Pulsed Barrier Discharge Using Laser Induced Fluorescence (레이져 유기형광법을 이용한 펄스 배리어 방전 공간에서의 NO분자에 대한 시·공간적 밀도변화 측정)

  • Han, Sang-Bo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.160-168
    • /
    • 2010
  • This paper tried to find out NO generation and removal mechanisms in the space of the atmospheric pulsed barrier discharge using laser induced fluorescence method, which is a very effective approach to the measurement of spatio-temporal density of specific molecules. The propagation velocity of the primary streamer reaches about $2.7{\times}10^6$[m/s] and the secondary streamer is produced in the vicinity of positive electrode after the primary streamer finished. In this work, pulse Nd:Yag and Dye lasers are used for generating the specific wavelength of 226[nm], which is possible to excite NO molecules into $A^2{\Sigma}^+{\rightarrow}X^2{\prod}$(0,0) and fluorescence signals as the transition of $A^2{\Sigma}^+{\leftarrow}X^2$(0,2) is measured. For the effective removal of NO molecules in the plasma discharge process, the lower oxygen contents are needed and the influence of secondary streamer for the reduction mechanism of NO molecules is important

Velocity Distribution Measurements in Mach 2.0 Supersonic Nozzle using Two-Color PIV Method (Two Color PIV 기법을 이용한 마하 2.0 초음속 노즐의 속도분포 측정)

  • 안규복;임성규;윤영빈
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.4
    • /
    • pp.18-25
    • /
    • 2000
  • A two-color particle image velocimetry (PIV) has been developed for measuring two dimensional velocity flowfields and applied to a Mach 2.0 supersonic nozzle. This technique is similar to a single-color PIV technique except that two different color laser beams are used to solve the directional ambiguity problem. A green-color laser sheet (532 nm: 2nd harmonic beam of YAG laser) and a red-color laser sheet (619 nm: output beam from YAG pumped Dye laser using Rhodamine 640) are employed to illuminate the seeded particles. A high resolution (3060${\times}$2036) digital color CCD camera is used to record the particle positions. This system eliminates the photographic-film processing time and subsequent digitization time as well as the complexities associated with conventional image shifting techniques for solving directional ambiguity problem. The two-color PIV also has the advantage that velocity distributions in high speed flowfields can be measured simply and accurately by varying the time interval between two different laser beams due to its high signal-to-noise ratio and thereby less requirement of panicle pair numbers for a velocity vector in one interrogation spot. The velocity distribution in the Mach 2.0 supersonic nozzle has been measured and the over-expanded shock cell structure can be predicted by the strain rate field. These results are compared and analyzed with the schlieren photograph for the velocity distributions and shock location.

  • PDF

Dye Laser Oscillator with System Monitoring Longitudinal Mode of Lasing Frequency (발진된 주파수의 종모드를 모니터하는 시스템이 부착된 색소 레이저 발진기)

  • Im, Kwon;Ko, Do-Kyung;Park, Sung-Hee;Kim, Yong-Ki;Cha, Byung-Heon;Kim, Chul-Joong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.62-63
    • /
    • 2002
  • 파장가변 색소 레이저 발진기는 반사형 회절격자에 비스듬히 입사하는 Grazing Incidence형 공진기 구조로 설계되었다.[1-2] 색소용액이 고속으로 순환되는 색소 셀에 여기광인 레이저 광원을 입사시키는 방법은 색소 셀과 색소 용액 순환방향 및 펌핑 광의 방향이 서로 수직을 이루도록 구성되어 있다. 또한, 두 개의 펌핑 광을 양방향에서 동시에 입사시킬 수 있도록 함으로써, 색소 셀 내부의 색소 용액이 여기 광을 균일하게 흡수하도록 설계하였다. (중략)

  • PDF

Estimation of Ground and Excited State Dipole Moments of Coumarin 450 by Solvatochromic Shift Method

  • Naik, L.R.;Math, N.N.
    • Journal of Photoscience
    • /
    • v.12 no.2
    • /
    • pp.57-61
    • /
    • 2005
  • The ground and excited state dipole moments of Coumarin 450 (C 450) laser dye were measured at room temperature in several solvents of varying dipole moments. The ground state dipole moment (${\mu}_g$) is estimated by using the modified Onsagar model and the excited state dipole moments (${\mu}_e$) were estimated by the method of solvatochromism as well as by utilizing the microscopic solvent polarity parameter ($E^N_T$). Further, the deviation of some of the points from the linearity of the $E^N_T$ versus Stokes shift indicates the existence of specific type of solute-solvent interaction. The excited state dipole moment of C 450 were found to be higher than those of the ground state and is interpreted in terms of the resonance structure of the molecule. A reasonable agreement has been observed between the values obtained by the method of solvatochromism and modified Onsagar model. It is observed that, corresponding to cyclohexane solution, the fluorescence maxima shift towards the red region with increasing the polarity of the solvents, hence the transition involved are of ${\pi}-{\pi}^*$ type.

  • PDF

Color Change Redox Behavior of the 1,3-Squaraine Dyes

  • Jun, Kun;Shin, Seung-Rim;Shin, Jong-Il;Park, Soo-Youl
    • Textile Coloration and Finishing
    • /
    • v.18 no.5 s.90
    • /
    • pp.53-60
    • /
    • 2006
  • The 1,3-bis(4-aminoaryl)squaraines showed color, change behavior, they were found to undergo reduction with sodium borohydride in solution to give colorless leuco compounds, which oxidized readily in air back to the colored squaraine dye. We have shown that initial observations indicated that the derivatives synthesized gave new donor-acceptor chromophores. It is also interesting to note than the oxidation of the leuco squaraines did initially produce a species absorbing about 630-680 wavelengths. The 1,3-squaraines have found many uses as near-infrared absorbers, laser dyes and photoconductive materials. Furthermore their color-change redox behavior has potential in the area of peroxidase-based bioassaysas oxidation sensitive indicator systems were investigated.

Synthesis and Characterization of Pentarylene Bisimide Derivative as NIR Colorant (NIR Colorant용 Pentarylene Bisimide의 합성 및 특성 연구)

  • Baek, Kwan;Jeong, Yeon-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.140-146
    • /
    • 2012
  • A variety of dyes are commercially available today, there is an ongoing need for new chromophoric systems and low-band-gap materials. For example, near-infrared (NIR) emission has received increased attention for applications in bioassays and medicine while NIR absorption is demanded for laser-welding of plastics or efficient blocking of heat rays. Most of the commercially available NIR materials are not suitable for such purposes owing to their insufficient stability. We have developed a novel NIR-absorbing polyaromatic dye. By extending the system of perylenebis(dicarboximide)s along the molecular long axis, we have obtained the higher homologue pentarylenebis(dicarboximide). We have tried to introduce imide functional group to pentarylene in order to increase chemical and thermal stability.

Ozone Monitoring in the Lower Tropospheric Atmosphere by LIDAR System (라이다 시스템을 이용한 하층 대류권 오존농도 측정)

  • 최성철;차형기;김덕현;김영상
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.5
    • /
    • pp.385-393
    • /
    • 2001
  • We have developed a Differential Absortion LIDAR (DIAL) method for the measurement of lower tropospheric ozone concentration. We used two laser beams from quadrupled Nd:YAG (266 nm) for the resonance wavelength and dye lasers (299.5 nm) for non -resonance wavelength. Aerosol extinction coefficients in the lower troposphere was computed by both Klett and Slope methods. To correct the SIN (Signal -Induced Noise) effect caused by photo detector, we subtracted a new-fitted baseline on the background part of a LIDAR signal, after the subtraction of the DC level. This is because SIN can be treated as an exponentially decaying tail. Using theme results, ozone profiles were obtained approximately 2km at daytime and 3km at nighttime. We compared the results derided by the Slope method with those measured by UV spectrometer. The computed results are in mostly good agreement with experimental results. In the measurement of the vertical layer, we observed the variation of the ozone profiles around the top mixed layer.

  • PDF

Simultaneous Measurements of Temperature and Velocity Fields of a Buoyant Jet Using LIE and PIV Techniques (LIE와 PIV 기법을 이용한 부력제트의 온도장과 속도장 동시측정)

  • Kim Seok;Jang Young Gil;Lee Sang Joon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.513-516
    • /
    • 2002
  • The flow structure and heat transfer characteristics of a turbulent buoyant jet were investigated experimentally. The instantaneous temperature and velocity fields in the near field were measured using a two-frame PIV and PLIF techniques. A thin light sheet illuminated a two-dimensional cross section of the buoyant jet in which Rhodamine B was added as a fluorescent dye. The intensity variations of LIF signal from Rhodamine B molecules scattered by the laser light were captured by a CCD camera after passing an optical filter. By ensemble averaging the instantaneous temperature and velocity fields, the mean temperature and velocity fields as well as the spatial distributions of turbulent statistics were obtained. The results show the flow structure and convective heat transfer of the developing shear layer in the near field.

  • PDF

Detection of Damage of Rd6G Film Using Surface Second-Harmonic Generation (표면 제2고조파 발생을 이용한 색소 Rd6G박막층의 손상 분석)

  • 유대혁;고춘수;임용식;이재형;장준성
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.272-277
    • /
    • 1994
  • The damage of a thin film of Rd6G dye was probed by Surface Second-Harmonic Generation(SSHG) method. A portion of the Rd6G thin film on glass substrate was damaged by 532 nm laser beam, and the damage was probed by detecting intensity variation of SSHG. The result was confirmed through direct observation with optical microscope.oscope.

  • PDF

펌프-촉침 방법을 이용한 피코초 순간 흡광 속도분광기 제작

  • 장두전
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.347-353
    • /
    • 1993
  • A picosecond transient absorption kinetic spectrometer using a pump-probe method is presented and compared with other methods of picosecond transient absorption measurements. This constructed kinetic spectrometer detects the transient transmittance of sample using a lock-in amplifier as a function of delay time between pump and probe pulses generated from a picosecond mode-locked cw dye laser. Typical transient absorption and ground state bleach recovery kinetic profiles measured with this spectrometer are shown. Excellent kinetic curves of transient absorption or ground state bleach recovery may be obtained at single wavelengths with this spectrometer.

  • PDF