• Title/Summary/Keyword: dust control

Search Result 470, Processing Time 0.041 seconds

Optimization of Fugitive Dust Control System for Meteorological Conditions (기상조건별 비산먼지 관리체계 최적화 연구)

  • Kim Hyun-Goo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.573-583
    • /
    • 2005
  • Fugitive dust, which is emitted in the ambient air without first passing through a stack or duct designed to control flow, is frequently generated by means of wind erosion from storage yards at Pohang Steel Wokrs. The size distribution of fugitive dust is mostly in the range of coarse particulate which is deposited as soon as emitted and less harm to human health; however $20\%$ of fugitive dust contains PM 10 known as one of most harmful airborne pollutant. Consequently, effective control and reduction of fugitive dust is strongly requested by the local society, but it is not easy so far because the generation and dispersion of fugitive dust highly depends on meteorological conditions, and it being occurred for irregularity. This research presented a fugitive dust control system for each meteorological condition by providing statistical prediction data obtained from a statistical analysis on the probability of generating the threshold velocity at which the fugitive dust begins to occur, and the frequency occurring by season and by time of the wind direction that can generate atmospheric pollution when the dispersed dust spreads to adjacent residential areas. The research also built a fugitive dust detection system which monitors the weather conditions surrounding storage yards and the changes in air quality on a real-time basis and issues a warning message by identifying a situation where the fugitive dust disperses outside the site boundary line so that appropriate measures can be taken on a timely basis. Furthermore, in respect to the spraying of water to prevent the generation of fugitive dust from the storage piles at the storage yard, an advanced statistical meteorological analysis on the weather conditions in Pohang area and a case study of fugitive dust dispersion toward outside of working field during $2002\∼2003$ were carried out in order to decide an optimal water-spraying time and the number of spraying that can prevent the origin of fugitive dust emission. The results of this research are expected to create extremely significant effects in improving surrounding environment through actual reduction of the fugitive dust produced from the storage yard of Pohang Steel Works by providing a high-tech warning system capable of constantly monitoring the leakage of fugitive dust and water-spray guidance that can maximize the water-spraying effects.

A Study on Dust Control Characteristics inside a Test Dome in the Port of Inchon (인천항 시험돔 내부의 먼지제어특성에 대한 연구)

  • Jeon, ki-Joon;D.Y. Ryu;Jung, Yong-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.E
    • /
    • pp.47-57
    • /
    • 2000
  • This study focuses on the investigation of the effects of windspeed and particle size on the dust control characteristics inside a test dome built in the Port of Inchon to reduce the fugitive dust originating from the handling of animal feed stuff in the open pile area. The flow field inside the test dome and the trajectories of the particles were calculated using a commercial CFD code, FLUENT, assuming that the animal feed stuff handling activity took place inside the test dome. It was found from the simulation results that high windspeed and small particle size give rise to the increase in both the escaped fraction and the suspended fraction of the particles emitted from the animal feed stuff handing activity. Here, high escaped fraction represents the high possibility of fugitive dust problem outside the test dome, whereas high suspended fraction means the high possibility of severe dust pollution inside the test dome. Ore simulation results clearly show that the existing test dome was not designed properly to meet the proposed goal, low escaped fraction and low suspended fraction. Hence, we suggest the need of an efficient ventilation system inside the dome to control the dust.

  • PDF

Improvement Plan of Fugitive Dust Regulations in Construction Site (건설현장 비산먼지 규정 개선방안)

  • Noh, Hyunjun;Yu, Jungho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.5
    • /
    • pp.68-76
    • /
    • 2017
  • A recent issue of fine dust is particulate matter with a diameter of less than $10{\mu}g/m^3$. It's classified as a pollutant that has a fatal effect on the human body when inhaled. The fugitive dust must be well controlled, since the adverse effects of dust on the surroundings are increased when the dust is blown away by the wind. Since the construction site is the place where the most fugitive dust is discharged in Korea, managing the fugitive dust discharged from the construction site can be an important issue to solve the problem of domestic fine dust. However, since the construction industry in Korea is the largest in Korea, it is difficult to control the emission of fugitive dust in the domestic construction site. In this paper, we compare and analyze the fugitive dust regulations applied to construction sites in major cities and propose the improvement plans to help control the fugitive dust generated in domestic construction sites.

A Study on the Suction Power Control of Vacuum Cleaner with a Dust Sensor (먼지센서에 의한 진공청소기의 흡입력 제어에 관한 연구)

  • 백승면;김성진;이만형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.304-307
    • /
    • 1995
  • In this paper, an optical sensing system has been developed to detect the dust in vacuum cleaner. The system works well through self-tuning mechanism, even though there are systemic variance and characteristic change which is caused by the pollution on the surface of the optical elements. Using the developed sensing system, a novel suction power control system has been proposed, which is able to be used for a long time.

  • PDF

A Dust Detection Sensor System for Improvement of a Robot Vacuum Cleaner (청소 로봇 성능 향상을 위한 먼지 검출 시스템)

  • Kim, Dong-Hoe;Min, Byung-Cheol;Kim, Donghan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.10
    • /
    • pp.896-900
    • /
    • 2013
  • In this paper, we develop a dust detection sensor system capable of identifying types of dust for an improvement of a robot vacuum cleaner. The dust detection sensor system is composed of a set of infra-red sensors: a single transmitter and multiple receivers. Given the fixed amount of light transmitted from the transmitter, the amount of light coming in multiple receiver sensors varies, depending on the type and density of dust that is passing between the transmitter and the receivers. Therefore, the type of dust can be identified by means of observing the change of the amount of light from the receiver sensors. For experiments, we use two types of dust, rice and sesame, and validate the effectiveness of the proposed method.

A Study on PM10 Control in Subway Tunnels Using Natural Polysaccharide Dust Collecting Agent (천연 다당류 먼지포집제를 이용한 지하철 터널 내 PM10 제어에 대한 연구)

  • Lee, Han-Seob;Hwang, Su-Jin;Hwang, Hyun-Seok
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.122-129
    • /
    • 2017
  • Objectives: Most of the $PM_{10}$ in subway stations is spread by the train-induced wind from the tunnels. Therefore, in order to improve air quality in subway stations, it is important to remove the $PM_{10}$ from the tunnels. After the installation of PSD (platform screen doors), the influence of train-induced wind and $PM_{10}$ at the platform has decreased, but is estimated to have increased in subway tunnels. This study was conducted to investigate the control of $PM_{10}$ in subway tunnels by applying a 500-fold diluted solution mixed with a humectant using a natural polymer. Methods: For this purpose, we tested the dust reduction effect in a laboratory and corrosion test and water pollution using fish and aquatic plants for the natural dust collecting agent. In the tunnel of a subway station, we used the natural dust collecting agent over 15 days. The study was carried out on $PM_{10}$ control during operation, which accounts for more than 70% of subway dust. Results: As results, the natural dust collecting agent exhibited an excellent dust control effect, and it was safe for water quality and soil. It showed the effect of controlling $PM_{10}$ in the subway tunnel by 49.5- 64.7% over 15 days. The use of the dust collecting agent for the control of $PM_{10}$ could be confirmed in the subway. Conclusion: It is necessary to clearly explain the major portions of chemical components contained in $PM_{10}$ to figure out the characteristics of $PM_{10}$ and to develop effective reduction measures to decrease the adverse effects of $PM_{10}$ in the subway.

Development of a Remote Dust Collector Bag Control System using Power Line Communication (전력선 통신을 이용한 원격 집진기 bag 제어 시스템 개발)

  • Kim, Jung-Sook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.4
    • /
    • pp.91-98
    • /
    • 2010
  • Advances in communications and control technology, the strengthening of the Internet, and the growing recognition of the urgency to reduce the risk and production cost are motivating the development of improvements in the traditional manufacturing industry. In this paper, we developed a remote dust collector bag control system which is a combination of advanced IT and traditional dust collector based on the event. At first, we made the A/D(Analog/Digital) converter using a micro processor because the differential pressure transmission, which is a sensor of the dust collector, produces analog volt data. A/D converter can provide RS-232 communication to connect with Power Line Communication(PLC) modem. And, n-bytes message format was defined for the efficient dust collector bag information transmission from a dust collector to a user. Also, we designed the data types to model the dust collector and the dust collector bag, and they were logically modeled using XML and object-oriented modeling method. In addition to that, we implemented the system for showing the dust collector bag exchange time exactly to users at real-time using various visual user interfaces.

Filtration Characteristics of the Fugitive Dust Emitting from Animal Feedstuff Handling (사료 부원료 하역과정에서 발생하는 비산먼지의 여과특성)

  • Bang Jin-Chul;Han Se-Hyun;Jung Yong-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.2
    • /
    • pp.191-199
    • /
    • 2006
  • Animal feedstuff handling is one of the major fugitive dust sources in the port of Incheon. For the effective control of fugitive dusts emitting from the port of Incheon, dust control facilities with bag filter systems should be designed properly considering the characteristic of the fugitive dusts including those from animal feedstuffs. The ultimate goal of this study is thus to develop the optimum fugitive dust control system which will be applicable for the renovation of the port. As the first step to achieve this longstanding goal, filtration characteristics of soybean shell, the largest dust sources in the port, were investigated with the specially designed filter testing apparatus for this study. The variables tested for the experiments included filter materials, dust concentrations, relative humidities, and filtration velocities. Also, the filtration characteristics of the other animal feedstuffs such as sunflower seed shell, tapioca, and palm shell were investigated to determine $K_2$ as a function of filtration velocity. The information on $K_2$ will be used to design the optimum bag filter systems for animal feedstuffs handling in the port.

Intelligent Dust Chamber Bag Control System using Case-Based Reasoning (사례기반 추론을 이용한 지능형 집진기 bag 제어 시스템)

  • Kim, Jung-Sook
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.1
    • /
    • pp.48-53
    • /
    • 2010
  • In this paper, we develop the intelligent remote dust chamber bag control system which is combination of the advanced IT and traditional dust chamber based on event. At first, the message format is defined for the efficient dust chamber bag information transmission using power line communication. Also, we define the data types to logically model the dust chamber and the dust chamber bag, and they are logically modeled using XML and object-oriented modeling method. In addition to, we apply the case-based reasoning for showing the dust chamber bag exchange time intelligently to user at real-time using casebase, that is collected by case or case-based reasoning result, and that is described using XML.

Efficacy of Fipronil-applied Canine Hair against House Dust Mites (Fipronil 적용 개 피모의 집먼지 진드기의 살진드기에 대한 효과)

  • 강선미;이충호;박옥지;임지혜;윤희정;권오경
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.215-218
    • /
    • 2002
  • It is known that house dust mites which settle on sofa, carpet, and dust in the house ignite asthma and allergic rhinitis. Dermatophagoides farinae and Dermatophagoides pteronyssinus distribute widely and densely in Korea. In this study we carried out to identify that shed hair of dogs which was applied topically with fipronil ($\Frontline^{circledR}$) kill house dust mites. We co-cultured house dust mites with fipronil-applied hair of dog during 12 hours, and then compared the death rate of mites here with that cultured without hair. The larger amount of hair, the more mites were killed. The death rate of mites was higher than control significantly until 2 weeks after $\Frontline^{circledR}$ application. Hair which had been shed at 3 days after $\Frontline^{circledR}$ application always killed the smaller number of mites than not shed. The present study suggested that the use of $\Frontline^{circledR}$ to our pets control house dust mites effectively.