Fault Tree Analysis을 활용한 집진기(Bag Filter) 고장의 체계적 분석 (A System Approach to A Bag Filter Failure using Fault Tree Analysis)

  • 이근희;이동형
    • 산업경영시스템학회지
    • /
    • 제12권20호
    • /
    • pp.1-24
    • /
    • 1989
  • This paper takes aim at the reliability evaluation by application of Fault Tree Analysis and its computerization. FTA is one of the methods for evaluation of system reliability and safety analysis. The important characteristic of this paper is that computer program is written in the package program(dBaseIII+) by 16Bit/AT personal computer. The program consists of three program segments. (1) The minimal cut sets of the system fault tree are obtained by means of "Fault tree reduction algorithm" (2) The minimal path sets are obtained by inversion of the minimal cut sets determined from fault tree (3) The importance of the basic events which are presented in the minimal cut sets is obtained by means of structural importance analysis. In this paper, a Fault Tree Analysis is applied to a BAG FILTER which is a kind of dust collector.collector.

  • PDF

석탄 화력 보일러에서의 응집제 이용에 따른 초미세먼지 거동 (Effect of Coagulants on the Behavior of Ultra Fine Dust in a Coal Firing Boiler)

  • 류환우;송병호
    • 공업화학
    • /
    • 제31권1호
    • /
    • pp.84-89
    • /
    • 2020
  • 초미세먼지로 분류되는 PM2.5 (particulate matter under 2.5 ㎛) 중에서도 특히 sub-micron 입자(0.1~1.0 ㎛)의 먼지는 브라운 운동(Brownian motion)으로 집진장치의 효율에 한계를 준다. 따라서 수산화나트륨으로 활성화된 알루미늄산나트륨(NaAlO2)을 응집제(coagulant)로 선택하여 석탄을 사용하는 유동층 보일러에서 석탄의 회분에 포함된 칼륨(K)과 PM2.5의 입도분포의 거동과 영향을 확인하고자 했다. 그리고 응집제를 석탄의 무게대비 1,200 : 1 비율로 석탄에 혼합 및 분사하면서 정상 운전하는 중에 보일러의 싸이클론에서의 미세먼지(FP)와 전기집진기에서의 미세먼지(EP)를 포집 및 고찰하였다. 포집한 미세먼지를 입도분석기를 이용하여 입도분포(%)를 분석한 결과 FP에서 평균 4.87%에서 0.51%로 변화를 보임으로써 89.53% 감소하였다. EP에서의 평균 3.46%에서 0.40%로 변화를 보임으로써 88.57% 감소하였다. 포집한 미세먼지를 XRP로 칼륨을 추적한 결과 칼륨의 변화율은 FP에서 평균 1.65%에서 1.87%로 13.33% 증가하고, EP에서 평균 1.65%에서 2.03%로 17.68% 증가하였다. TMS에 의해서 확인된 총 미세먼지 농도(mg/㎥)는 1차는 2.6 mg/㎥에서 1.7~1.9 mg/㎥로 26.9~34.6% 감소하였으며, 2차는 평균 2.9 mg/㎥에서 1.7~1.9 mg/㎥로 33.3~40.4%가 감소하였다. 따라서 본 연구의 응집제가 PM2.5 초미세먼지 입자의 크기와 그로 인한 집진장치효율에 크게 영향을 미치는 것으로 확인하였다.

싸이클론과 배플 및 백필터 원리를 결합한 하이브리드형 집진기의 최적화 설계를 위한 수치해석 (A Numerical Study on an Optimum Design of a Hybrid Collector Coupled with the Principle of Cyclone, Baffle and Bag-Filter)

  • 홍성길;정유진;임기혁;유정근;손병현
    • 한국산학기술학회논문지
    • /
    • 제14권2호
    • /
    • pp.983-989
    • /
    • 2013
  • 본 연구에서는 하나의 장치 내에서 "싸이클론-관성충돌-여과포 집진"이 동시에 이루어지는 멀티 집진기의 집진 효율을 극대화시키기 위한 설계 조건을 검토하였다. 먼저 싸이클론의 입구 형상에 대한 수치 해석 결과, 접선 유입식 입구에 가이드 베인을 추가로 설계한 경우 선회류의 회전수가 많고 강하게 형성되어 사이클론부에서 조대입자의 유선 이탈을 촉진시키는데 매우 효과적인 것으로 예측되었다. 그러나 사이클론의 하단부가 벤츄리 모양이기 때문에 약 4~5 m/s의 강한 하향 흐름이 호퍼 하단까지 지속되어 분진의 재비산 가능성이 있는 것으로 나타났다. 이에, 사이클론부 하단의 벤츄리를 제거하며 분진 재비산 문제는 해소 가능할 것으로 나타났다. 충돌 차단형 배플의 간격을 조정하여 통과유속을 빠르게 한 결과, 충돌 효과는 더욱 증가할 것으로 예측되었으나 탈리 분진이 간섭을 받을 수 있는 문제점이 예상되어 배플은 기본 설계안대로 유지하는 것이 바람직할 것으로 나타났다.

역류형 컬럼 부선기를 이용한 석탄회정제에 관한 연구 (Removal of Unburned Carbon from Fly Ash using Countercurrent Column Flotation Cell)

  • 이전언;이제군
    • 자원리싸이클링
    • /
    • 제8권5호
    • /
    • pp.51-58
    • /
    • 1999
  • 석탄화력 발전소에서 발생하는 수백만 톤의 석탄회는 콘크리트 혼화재 및 건축자재로 재활용이 가능함에도 불구하고 과다한 미연탄소 함량으로 인해 대부분 회사장(Ash Pond) 되는데, 이로 인해 환경오염유발, 회사장 포화에 따른 발전소의 수명 감소, 그리고 재활용 가능한 자원의 낭비와 같은 문제가 발생한다. 본 연구는 석탄회 내의 미연탄소분을 분리하여 미연탄소분 함량이 낮은 고순도 석탄회를 회수하기 위해 직류관 믹서(In-Line Mixer) 발생기키는 역류형 컬럼부선기를 이용하였다. 이때 입자 표면에 소수성의 특성을 강화시키는 포스제의 증가에 따른 석탄회와 미연탄소 입자의 분리 특성을 분석하였다. 석탕회 톤당 8ι의 포수제를 사용한 역류형 컬럼 부선기를 이용하여 미연탄소분 함유량이 7%인 석탄회를 분리 실험한 결과 미연탄소분 함유량 0.5%인 고순도 석탄회를 88.2% 회수하였다. 그리고 질량 평균입경이 21.2$mu extrm{m}$인 석탄회를 분리 실험하여 입도를 분석한 결과 분리 정도에 따라 입도는 뚜렷하게 구별되어 나타났는데, 분리효율이 증가할수록 정제 석탄회의 경우 입도는 조대해져 입도 분포의 양극화 현상이 뚜렷하게 나타났다. 포수제의 투입량이 증대함에 따라 미연탄소 입자의 계면에 소수성이 강화되어 분리 특성이 향상되었으며, 이때 회수한 고순도 석탄회의 입도는 미세화 되는 경향이 나타났다.

  • PDF

미세먼지(PM10)와 초미세먼지(PM2.1)의 농도와 폐포 침착율 조사 (Investigation of the Concentration of PM2.1 & PM10 and Alveolar Deposition Ratio)

  • 김성천
    • 한국환경보건학회지
    • /
    • 제45권2호
    • /
    • pp.126-133
    • /
    • 2019
  • Objectives: In this study, a nine-stage cascade impactor was used to collect dust, and the concentration of $PM_{2.1}$ & $PM_{10}$ and alveolar deposition ratio were investigated. Methods: This study was conducted at Kunsan National University from May to June 2016. A nine-stage Cascade Impactor was used to analyze the concentrations of fine and ultrafine dust and to estimate the alveolar deposition rate by particle size of atmospheric dust particles. The pore size of each stage of the collector used in this study gradually increased from F to 0, with the F-stage as the last stage. Results: The mass fraction of PM showed a bimodal distribution divided into $PM_{2.1}$ & $PM_{10}$ based on $2.1-3.1{\mu}m$. The average mass fraction of particulate matter in the range of $2.1-3.1{\mu}m$ was 44%, and the area occupied by $PM_{2.1}$ was similar. Therefore, the Gunsan area is considered to be a region where there are similar effects from anthropogenic and natural sources. Conclusion: Dust collecting efficiency increased with the stage of collecting fine dust, and the efficiency of collection was very low at the stage of collecting ultra-fine dust. The seasonal overall efficiency of the Cascade Impactor was 44% in spring and 37.4% in summer, and the average overall efficiency was 40.7%. The alveolar deposition rate of $PM_{2.1}/PM_{10}$ during the sampling period was estimated to be about 75% deposited in the alveoli.

카트리지 필터 여과집진기 충격기류시스템의 최적탈진조건에 관한 실험적 연구 (Experimental Study on Optimum Pulse Jet Cleaning Conditions of a Cartridge Filter System)

  • 박승욱;하현철;김성준
    • 한국산업보건학회지
    • /
    • 제25권4호
    • /
    • pp.542-553
    • /
    • 2015
  • Objectives: Many types of dust collector are used for industrial ventilation, with the most common types being the cylinder bag filter system, rectangular bag filter system and cylinder type cartridge filter system. The cylinder type cartridge bag filter, which has more filtering area than other types of bag filter, can increase the pulse time and extend the useful life of the filter. This can save operational costs and installation area. Materials: This study used cylinder type cartridge bag filter equipment and tested the impact of vibration level and filter pressure with different pulse jet cleaning conditions. The final, cleaning efficiency was calculated through input dust mass and cleaning dust mass Conclusions: Two optimum cleaning condition groups were found. The first condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.2 s pulse time with an H-10 type nozzle. The second condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.3 s pulse time with an H-10 type nozzle.

반응표면법을 활용한 축류형 사이클론 구조 최적화 설계에 관한 연구 (A Study on Optimum Design of an Axial Cylcone structure using Response Surface Method)

  • 조진일;윤준호;조영광;석현호;김태성
    • 한국입자에어로졸학회지
    • /
    • 제17권3호
    • /
    • pp.71-79
    • /
    • 2021
  • Ultrafine dust, which is emitted from industrial factories or all kinds of vehicles, threatens the human's respiratory system and our environment. In this regard, separating airborne particles is essential to mitigate the severe problem. In this work, an axial cyclone for the effective technology of eliminating harmful dust is investigated by numerical simulation using Ansys 2020, Fluent R2. In addition, the optimized structure of the cyclone is constructed by means of multi objective optimization based on the response surface method which is a representative method to analyze the effect of design parameter on response variables. Among several design parameters, the modified length of the vortex finder and dust collector is a main point in promoting the performance of the axial cyclone. As a result, the optimized cyclone exhibits remarkable performance when compared to the original model, resulting in pressure drop of 307 Pa and separator efficiency of 98.5%.

Air Shot Blast 작업실 내부 환기 시스템 개선에 관한 수치해석 (Numerical Analysis on the Ventilation System Improvement in Air Shot Blast Room)

  • 진도훈
    • 한국산업융합학회 논문집
    • /
    • 제25권5호
    • /
    • pp.861-868
    • /
    • 2022
  • The purpose of this study is to design an effective atmospheric environment system through the design of the dust collection in the air shot room being operated in a domestic shipyard. The ventilation system in the current air shot room mostly uses a dust collecting filter to filter internal particles and releases them in the atmosphere. A conventional design was made too much. In order to prevent an error and draw an optimal design, Computational fluid dynamics (CFD) tried to be applied only to air shot room. In the advanced design technique, computer simulation was conducted to secure basic design data. In order to find the basic design of the ventilation system and the flow field in the air shot room at propeller mold workplace of a shipyard, the CFD was conducted. In the case of Model-1 as a conventional workplace, where air flows in the inlet due to the subatmospheric pressure generated by inhalation of an air blower and flows out to the outlet, a discharge flow rate was somewhat low, and there was the holdup zone in the room. In the case of Model-2 as an improved model, the ventilation system was improved in the Push-Pull type, and the holdup of the internal flow field was improved.

터널 굴착시 작업현장의 분진농도 실태조사 (System Analysis of Dust Concentration at the Field of Tunnel Excavation)

  • 박종순;안대현;심명진;정지승;유진오;엄명헌;김재용
    • 공업화학
    • /
    • 제18권2호
    • /
    • pp.126-129
    • /
    • 2007
  • 원할한 교통망 요구에 따라 도로의 확충이 요구되고, 산악지형이 많은 국토의 특성을 고려할 때 터널이 많이 요구된다. 이러한 터널 공사에서 많은 오염 물질은 천공, 발파, 버럭처리 숏크리트 과정에서 발생되었다. 특히 급기 팬만을 가동 할 경우 분진과 같은 오염물질은 발파 후 4 h이 지나도록 $5000{\mu}g/m^3$ 이상을 나타내었으며, 발파 직후에는 높은 분진 농도로 인하여 30 min 이상 작업을 중단할 수밖에 없었다. 또한 건식 집진기를 가동 할 경우에도 일정 시간 까지는 분진의 제거는 가능하였으나 발파 후 3 h이 지나면 집진 효율이 없는 것으로 나타났다. 본 논문 에서는 분진입자들의 거동과 분진제거장치의 사용에 대해 중점적으로 연구하였다. 또한 건식집진기와 습식집진기의 사용에 있어 각각에 대한 집진제거효율을 비교검토하는 것이 매우 중요하다 결론을 얻었다.