• Title/Summary/Keyword: dust collection efficiency

Search Result 108, Processing Time 0.031 seconds

Preparation of Poly(vinyl alcohol)/polypropylene Nano-filter by High Speed Centrifugal Solution Spinning (초고속 용액 원심방사를 이용한 폴리비닐알코올/폴리프로필렌 나노필터 제조)

  • Yang, Seong Baek;Lee, Jungeon;Park, Jae Min;Jung, Jae Hoon;Kim, Tae Young;Kim, Ki Young;Lee, Sang Jun;Yeum, Jeong Hyun
    • Textile Coloration and Finishing
    • /
    • v.34 no.1
    • /
    • pp.20-26
    • /
    • 2022
  • Centrifugal spinning is an emerging technique for fabricating micro-to-nano-fibers in recent years. To obtain fibers with the desired size and morphology, it is necessary to configure and optimize the parameters used in centrifugal spinning. In this study, it was controlled by changing the solution's concentration (7.5, 10, and 12.5 wt.%) and disk's rotational velocity (6,000, 8,000, and 10,000 rpm) to prepare centrifugal spun nano-filter. The morphological property, air permeability, and dust collection efficiency of the PVA/PP bi-layer nanoweb prepared by centrifugal spun PVA on the PP micron nonwoven substrate are studied using a field emission scanning electron microscope, an air permeability tester, and a filter tester equipment, and the analysis results indicate that it is suitable as a nano-filter when the concentration of PVA solution is 10 wt.% and the rotational velocity of the disk is 8,000 rpm. The resultant reduced diameter and uniform fibers also proved that an excellent dust collection efficiency filter could be made.

Flow Analysis of Yellow Dust Multi-Layer Mask for Maximization of Filtration Area (여과면적이 극대화된 황사용 주름마스크의 유동해석)

  • Jang, Sung-Cheol;Kim, Han-Joo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.4
    • /
    • pp.339-343
    • /
    • 2017
  • Masks are a portable functional product for daily use. They can protect user health by filtering harmful fine particles in the air. In the past decade, there have been approximately 10 yellow dust incidences per year, amounting to a total duration of 20 days, and they continue to increase year after year. In addition, the frequency of yellow dust incidences in Korea has increased by more than four times compared to levels from the 1970s. Statistical reports indicate that annual damages caused by yellow dust amount to more than six trillion KRW. This study developed a zero-fog multi-layer mask with a collection efficiency and yellow dust and particulate matter filtration areas that are at least thrice as effective as existing masks. The new mask also reduces pressure drag by half.

Fine Iron Dust Collection by Magnetized Mesh Filters (철성분 미세먼지 포집을 위한 자성 필터 연구)

  • Park, Haewoo;Huang, Shan;Chung, Sang Gui;Kim, Sangbum;Jo, Young Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.2
    • /
    • pp.118-130
    • /
    • 2015
  • Fine dust containing iron compounds is of current interests in metro subway as well as large scale industries including iron manufacturing and smelting works. This work attempts to find a new design of magnetic filter module for iron dust capture. It simulated the vertical rectangular duct with metal mesh which might promote electric fields in the duct space. A lab test using coal fly ash composed of 8.66% Fe with the most form of $Fe_3O_4$ and $Fe_2O_3$ showed capability of magnetic collection. It showed the capture efficiency with 80~93% for $PM_{2.5}$ depending on magnetic intensity. Ferromagnetic wire mesh contributed up to 50% of collection increment.

A numerical fluid dynamic study of a high temperature operating cyclone (고온 작동 싸이클론 유체역학적 거동 전산 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1033-1040
    • /
    • 2009
  • One thing to note in cyclone operation and design is to minimize the pressure drop with the enhancement of the efficiency of dust collection. This can be facilitated by the detailed resolution of complex fluid flow occurring inside a cyclone. To this end, the main objective of this study was to obtain the detailed fluid dynamics by the development of a reliable computation method and thereby to figure out the physics of dust collection mechanism for more extreme environment caused by high temperature and pressure condition. First of all, the computer program developed was evaluated against experimental result. That is, the numerical calculation predicts well the data of experimental pressure drop as a function of flow rate for the elevated pressure and temperature condition employed in this study. The increase of pressure and temperature generally affects significantly the collection efficiency of fine particle but the effect of pressure and temperature appears contrary each other. Therefore, the decrease of collection efficiency caused by the high operating temperature mainly due to the decrease of gaseous density can be remedied by increase of operating pressure. After the evaluation of the program, a series of parametric investigations are performed in terms of major cyclone design or operating parameters such as tangential velocity and vortex finder diameter for dusts of a certain range of particle diameters, etc. As expected, tangential velocity plays the most important effect on the collection efficiency. And the efficiency was not affected significantly by the change of the length of vortex finder but the diameter of vortex finder plays an important role for the enhancement of collection efficiency.

Deflective Behavior of Charged Particles in a Two-Stage Electrostatic Precipitator

  • Lim, Hun-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.83-91
    • /
    • 2011
  • Even if smoke, fumes, mist or dust particles are removed by electrostatic precipitators (ESPs), the occurrence of ozone, which is harmful to human body, has to be severely restricted in the indoor environments of hospitals, offices, and workshops. Therefore, the two-stage ESP generating positive corona at the ionizer is typically used because it creates less ozone than the two-stage ESP generating negative corona at the ionizer. In order to predict the collection performance and the optimal design of the two-stage ESP applied to positive high-voltage, particle concentration is experimentally investigated in this paper. In addition, particle motion within the collector section is also numerically analyzed. The positive corona discharge current of the ionizer is found to be affected by the applied voltage in the collector section but less so by the particle concentration. Particle concentration shows a minimum near the high voltage electrode of the collector section. The minimum value of the collection efficiency is almost proportional to gas velocity. When the collector length decreases, the minimum value of the collection efficiency increases. Charged particles entering the collector region are linearly deflected towards the grounded plate by an electric field. From the above experimental and numerical results, two empirical equations on the concentration ratio and the collection efficiency are derived, and are in good agreement with the experimental data.

Recent Research and Development on Aerosol Cyclones-Review

  • Lee, K.W.;Kim, H.T.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.E
    • /
    • pp.59-68
    • /
    • 2000
  • In this paper Various aerosol cyclones that are developed recently form Kwangju Institute of Science and Technology(KJIST) for increasing collection efficiency or for decreasing pressure drop are reviewed. For the first time, new sets of experimental data are reported on the particle collection efficiency of cyclones with modified surface bodies namely, spiral guide body, circumferential groove body, and vertical groove body. Multi-cylinder cyclones by adding one or two additional cylindrical walls into the conventional cyclone are also described. Ad an attempt to increase the collection efficiency of small particles, electrocyclone using an externally applied electric field was designed and operated. In addition, factors affecting the cyclone performance were studied including flowrate, body and outlet sizes, cyclone dust outlet, and gas property.

  • PDF

Characteristics of long-term operated Electrostatic airclean filter for air-conditioner (장시간사용(長時間使用)한 공조용(空調用) 전기집진(電氣集塵)필터의 특성(特性))

  • Hong, Young-Ki;Kang, Kwang-Ok;Lee, Sung-Hwa;Son, Sang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.453-455
    • /
    • 1995
  • In electrostatic airclean filter, the collection efficiency defends on particle charge in the ionizer section. The effect of electrostatic airclean filter condition (deposition of dust, variation of corona discharge current) on corona discharge characteristics was well studied. However, it seems not to be studied on corona discharge characteristics of electrostatic airclean filter respect to contaminated electrode which is caused by practical use. In this paper, Long-term(60days) effects are studied experimentally by two methods. The one is ozone concentration, the other is collection efficiency. Generation of ozone level was increased but collection efficiency was slightly reduced in long-term used electrostatic airclean filter.

  • PDF

Dust Removal Efficiency and Operation Characteristics of Metal Filters for Coal Gasification Fines and Standard Dust Sample (금속필터를 사용한 석탄가스화 분진 및 표준 분진의 집진 효율과 운전특성)

  • Yun, Yongseung;Chung, Seok Woo;Lee, Seung Jong
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.461-468
    • /
    • 2019
  • Demand for improving dust removal efficiency in coal power plants and the dust removal requirement to the level of capturing fine particulate matter and ultrafine particles have been increasing. While bag filter and electrostatic precipitator (ESP) are typically used for dust removal in the processes operating at atmospheric pressure, metal filters or ceramic filters are employed for dust which is produced at high temperature/pressure system as in coal gasification. For dust removal at the high temperature/pressure conditions, two metal filters of five compressed/sintered layers were manufactured and applied to analyze the dust removal characteristics. Manufactured metal filters exhibited more than 99% dust removal efficiency on coal gasification fine particulates in mass basis. To evaluate the fine particulate removal efficiency of less than $2.5{\mu}m$, JIS standard fine sample was used and confirmed the removal efficiencies of 97% and 70~82% on the fine particulates of $1{\sim}2.5{\mu}m$ size range. For the size range of less than $1{\mu}m$, dust removal efficiency of manufactured metal filters significantly degraded with smaller particle size. Improving methods are proposed to overcome the limitations in applying to fine dust of less than $1{\mu}m$.

Collection Characteristics of Multi-layer Multi-stage Porous Plate System (다층 다단 다공성 플레이트 시스템의 집진 특성)

  • Kim, I.K.;Yoa, S.J.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.10-16
    • /
    • 2010
  • The main object of this study is to investigate the collection characteristics of multi-layer multi-stage porous plate system experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as inlet velocity, tube diameter, inlet concentration, and stage number, etc. In results, the pressure drop becomes 22 to $115mmH_2O$ with increment of stage number (1 to 5) of porous plate system at tube velocity 15 m/s and tube diameter ${\Phi}8$. In case of fly ash and 5 stage, the collection efficiency becomes 90.5 to 95.7% increasing the tube velocity 12 to 15 m/s at inlet concentration $3g/m^3$ and tube diameter ${\Phi}8$. Additionally, it is estimated that the collection efficiencies of 5 stage are 94.3, 95.6 and 99.1% for fly ash, steel dust and based power, respectively (${\Phi}8$ tube, $V_t$ = 12m/s, inlet concentration $3g/m^3$).

Dust Collection Characteristics of Multi-layer Multi-stage Porous Plate System with Ionizer and Dielectric-substance (이오나이저 및 유전체 방식을 도입한 다층 다단 다공성 플레이트 시스템의 집진특성)

  • Yoa, Seok-Jun
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.63-72
    • /
    • 2013
  • The main purpose of this study is to analyze the collection characteristics of multi-layer multi-stage porous plate system with ionizer and dielectric-substance experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with experimental parameters such as applied voltage, inlet velocity, stage number and inlet particle concentration, etc. In results, for multi-layer multi-stage porous plate system of inflow type, at 5 stage and $v_{in}$=2.58 m/s, the pressure drop becomes lower 15 $mmH_2O$ as 95 $mmH_2O$ than that of non-inflow type system. It is estimated that for the present system with ionizer and dielectric-substance, the collection efficiency represents 98.5% showing higher 5.2% comparing to that of multi-layer multi-stage porous plate system without ionizer and dielectric-substance at 5 stage, $v_{in}$=2.58 m/s and inlet concentration $3g/m^3$(fly ash).