• Title/Summary/Keyword: duplex stainless steel

Search Result 183, Processing Time 0.02 seconds

Property differences between GTAW and SMAW duplex stainless steel weld metal (이상계 스테인레스 강 용접부의 인성과 내식성 거동)

  • 백광기;김희진;안상곤
    • Journal of Welding and Joining
    • /
    • v.4 no.3
    • /
    • pp.58-71
    • /
    • 1986
  • Mechanical and corrosion property of duplex stainless steel weldments made by the GTAW and SMAW process were studied. Fracture toughness, general and local corrosion resistance of GTAW and SMAW weldments were evaluated in terms of Charpy V notch impact test, anodic polarization diagram, pitting corrosion rate, respectively. SMA weld metal showed much lower impact toughness and higher ductile-brittle transition temperature than GTA weld metal. Fractographic and EDX analysis on fracture surface of SMA weld metal demonstrated the existence of (Si, Ti), oxide in large amounts. Potentiodynamic anodic polarization diagram of GMA weld metal showed much lower passive current density than SMA weld metal in 4% $H_2/SO_4$ solution. And pitting corrosion rate test showed the same tendency. Relating the microstructure, chemistry and property, it can be concluded that GTA weld metal gives better toughness due to lower oxygen content, i.e. lower inclusion content, and better corrosion resistance due to higher Pitting Index(PI) than SMA weld metal.

  • PDF

Microstructure and Mechanical Property of Brazed Joint in Duplex Stainless Steel, UNS32550 (브레이징한 2상 스테인리스강 UNS32550의 미세조직 및 기계적 특성)

  • 김대업;강정윤
    • Journal of Welding and Joining
    • /
    • v.21 no.2
    • /
    • pp.64-69
    • /
    • 2003
  • The bonding phenomena and mechanical property of duplex stainless steel during brazing have been investigated. The UNS32550 was used for base metal, and the MBF50 was used for insert metal. Brazing was carried out under the various conditions (brazing temperature : 1473K, 1498K, holding time : 0∼1.8ks). There were various microconstituents in the bonded interlayer because of reaction between liquid insert metal and base metal. In the early stage of brazing, BN is formed in the bonded interlayer and base metal near the bonded layer. Cr made is formed in the bonded interlayer. The amount of BN and Cr nitrides decrease with the increase of bonding temperature and holding time. Superior shear strength of 550MPa is obtained by restraining the formation of nitrides. (Received January 17, 2003)

Low Cycle Fatigue Characteristics of Duplex Stainless Steel with Degradation under Pure Torsional Load (순수 비틀림 하중하에서 열화를 고려한 2상 스데인리스강의 저주기 피로특성)

  • Gwon, Jae-Do;Park, Jung-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.9
    • /
    • pp.1897-1904
    • /
    • 2002
  • Monotonic torsional and pure torsional low cycle fatigue(LCF) test with artificial degradation were performed on duplex stainless steel(CF8M). CF8M is used in pipes and valves in nuclear reactor coolant system. It was aged at 430$^{\circ}C$ for 3600hrs. Through the monotonic and LCF test, it is found that mechanical properties(i.e., yield strength, strain hardening exponent, strength coefficient etc.) increase and fatigue life(N$\sub$f/) decreases with degradation of material. The relationship between shear strain amplitude(${\gamma}$$\sub$a/)and N$\sub$f/ was proposed.

Study on the optimum hot forming temperature and solution heat treatment temperature for the super duplex stainless steel weld (수퍼 이상 스테인리스강 용접부의 최적 열간 성형온도 및 용체화 열처리 온도에 관한 연구)

  • Ji Chun-Ho;Choi Jun-Tae;Kim Dae-Sun
    • Proceedings of the KWS Conference
    • /
    • 2006.05a
    • /
    • pp.137-139
    • /
    • 2006
  • In order to establish the optimum hot forming temperature and solution heat treatment temperature for 25% chromium super duplex stainless steel weld, a commercial 25%Cr-10%Ni-4%Mo weld metal for super duplex stainless steel(UNS S32750) with different solution heat treatment conditions at $1100^{\circ}C,\;1050^{\circ}C,\;1025^{\circ}C\;and\;1000^{\circ}C$ for 1.5 hours has been investigated by means of optical metallography, and estimated mechanical properties. It is found that exposure to elevated temperatures at $1050^{\circ}C,\;1025^{\circ}C\;and\;1000^{\circ}C$ except $1100^{\circ}C$ brings partial decomposition of ferrite to austenite and sigma phase, which deteriorates their properties and heat treatment at $1100^{\circ}C$ shows acceptable mechanical properties.

  • PDF

The Effect of Solution Heat Treatments on the Microstructure and Corrosion Behaviour for a Duplex Stainless Steel

  • Kim, Ki-Joon;Lee, Joon-Goo;Oh, Jae-Whan;Lee, Myung-Hoon;Moon, Kyung-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.217-227
    • /
    • 2004
  • The bowl in a ship purifier suffers from high stress and high temperature in a detrimental heavy fuel oil environment. Duplex stainless steel(DSS) is a primary material to withstand this harsh condition. Newly-manufactured STS 329 grade DSS has been evaluated by various mechanical and electrochemical test methods. Eight heat treatment(HT) conditions with different temperature and time were applied to the DSS samples to improve corrosion resistance. Microstructure and polarization test results concluded the optimum HT condition was $1.090^{\circ}C$-60 minutes. Confirmation experiments for applying to a real bowl including stress corrosion cracking test exhibited the reproducibility of the optimum HT condition.

A Study on the Characteristics of Cavitation Erosion of Super Duplex Stainless Steel (슈퍼 듀플렉스 스테인리스강의 캐비테이션 마모 특성에 대한 연구)

  • Jeon, Soon-Hyeok;Kim, Soon-Tae;Lee, In-Sung;Park, Yong-Soo
    • Journal of Korea Foundry Society
    • /
    • v.30 no.4
    • /
    • pp.142-146
    • /
    • 2010
  • To elucidate the characteristics of cavitation erosion of super duplex stainless steel, a cavitation erosion test, an optical microstructure, a hardness test, and a transmission electron microscope (TEM) analysis were conducted. As aging time at $475^{\circ}C$ increased, the hardness of ferrite phase increased whereas that of austenite phase was nearly constant. The reason why the cavitation erosion resistance increased with an increase of aging time was due to the formation of W-rich phases (${\alpha}$') of a nanometer scale with the high hardness that were precipitated within ${\alpha}$-grains and at ${\alpha}$-grain boundaries during aging, compared with that of the solution annealed alloy.

A Study on the Precipitation of σ Phase in Super Duplex Stainless Steel (슈퍼 2상 스테인리스강의 σ상 석출에 관한 연구)

  • Gang, Chang-Yong;Klm, Ick-Soo
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.5
    • /
    • pp.286-291
    • /
    • 2001
  • This study was carried out to investigate the influence of ${\sigma}$ phase on the microstructure and mechanical properties in super duplex stainless steel. The precipitation of ${\sigma}$ phase during isothermal heat treatment showed the type S curves with a certain incubation period. The precipitation of ${\sigma}$ phase was precipitated at ferrite phase and interface of ferrite and austenite. Under the state of isothermal transformation, the precipitation of ${\sigma}$ phase was stimulated by applied stress. With increasing of volume fraction of precipitated ${\sigma}$ phase, tensile strength was increased and elongation was decreased with linear relationship, while in case of precipitated ${\sigma}$ phase was 5% over, impact value was rapidly decreased.

  • PDF

Effect of Treatment Temperature and Gas Content on the Characteristics of Surface Layer of Low Temperature Plasma Nitrided Duplex Stainless Steel. (Duplex Stainless Steel (2205)의 Low Temperature Plasma Nitriding 처리시 처리온도 및 가스함량에 따른 S-phase 거동)

  • Lee, In-Seop
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.291-292
    • /
    • 2015
  • Duplex Stainless Steel의 Plasma Nitriding 처리 시 가스량과 처리온도가 표면 특성에 미치는 영향을 조사하였다. $N_2$함량 및 처리 온도가 각각 10%에서 25%로 $400^{\circ}C$에서 $430^{\circ}C$로 증가함에 따라서 질소가 과고용된 S-phase의 두께 및 표면 경도가 증가하였으나, 내부 식성은 $Cr_2N$$(Fe,Cr)_4N$이 석출하여 감소하였다. 질소를 10%로 고정하고 $CH_4$함량을 증가시키면 1%일 때 S-phase의 두께가 최대가 되며 그이후로 감소하였다. 처리온도 $400^{\circ}C$일 때 질소함량이 10%, $CH_4$ 함량이 5%일 경우 내식성이 모재보다 증가하였다.

  • PDF

Effects of Nitrogen on Deformation Behavior of Duplex Stainless Steel (이상 스테인리스강의 변형거동에 미치는 질소의 영향)

  • 이형직;장영원
    • Transactions of Materials Processing
    • /
    • v.12 no.4
    • /
    • pp.284-289
    • /
    • 2003
  • The effects of nitrogen on the deformation behavior of duplex stainless steel have been studied. The variation of strength was correlated with the characteristic microstructures pertaining to nitrogen. Analysis based on Hall-fetch relation confirmed that nitrogen enhances phase-boundary strengthening effect. The evolution of dislocation structure, slip traces and misorientation distribution during deformation were also characterized to elucidate the effect of nitrogen on inelastic deformation mechanism. It has been verified in this study that the higher nitrogen content provides a dual-phase microstructure with smaller strength difference between austenite and ferrite resulting into the earlier transfer of inelastic deformation from austenite to ferrite.

Fatigue Crack Propagation of Super Duplex Stainless Steel and Time-Frequency Analysis of Acoustic Emission (수퍼 2상 스테인리스강의 피로균열 진전특성과 음향방출신호의 시간-주파수 해석)

  • Lee, Sang-Kee;Do, Jae-Yoon;Nam, Ki-Woo;Kang, Chang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.73-78
    • /
    • 2000
  • On this study, the fatigue crack propagation of super duplex stainless steel is investigated in conditions of various volume fraction of austenite phase by changing heat treatment temperature. And we analysed acoustic emission signals during the fatigue test by time-frequency analysis methods. As the temperature of heat treatment increased, volume fraction of austenite decreased and coarse grain was obtained. The specimen heat treated at $1200^{\circ}C$ had longer fatigue life and slower rate of crack growth. As a result of time-frequency analyze of acoustic emission signals during fatigue test, main frequency was $200{\sim}300kHz$ having no correlation with heat treatment and crack length, and 500kHz was obtained by dimple and separate of inclusion

  • PDF