• Title/Summary/Keyword: dual-wavelength

Search Result 126, Processing Time 0.027 seconds

Dual-wavelength Digital Holography Microscope for BGA Measurement Using Partial Coherence Sources

  • Cho, Hyung-Jun;Kim, Doo-Cheol;Yu, Young-Hun;Jung, Won-Ki;Shin, Sang-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.352-356
    • /
    • 2011
  • Dual-wavelength holography has a better axial range than single-wavelength holography, allowing unambiguous phase imaging. Partial coherence sources reduce coherent noise, resulting in improved reconstructed images. We measured a ball-grid array using dual-wavelength holography with partial coherence sources. This holography method is useful for measurement samples that exhibit coherence noise and have a step height larger than the single wavelength used in holography.

Study on Error Reduction in Dual Wavelength Digital Holography Using Modified Fine Map (수정된 화인 맵을 이용한 2-파장 홀로그래피와 잡음 제거 연구)

  • Yu, Young-Hun
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.3
    • /
    • pp.129-133
    • /
    • 2011
  • Dual-wavelength holography has better axial range than single-wavelength holography, allowing unambiguous phase imaging but at the expense of increased noise. We have studied error reduction in dual wavelength holography using a modified fine map. The fine map is successful in measurement and has shown error reduction when the height of the object is less than the appled wavelength, but is unstable when the step height is larger than that wavelength. We have modified the fine map and we have found that the modified fine map was successful in measurement and error reduction even though the height of object was larger than the wavelength.

Tunable Channel Spacing of Dual-wavelength Erbium-doped Fiber Ring Laser using a Single Fiber Bragg Grating with Two Coil Heaters

  • Sohn, Kyung-Rak;Kim, Hyung-Pyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.153-158
    • /
    • 2009
  • Stable and tunable dual-wavelength erbium-doped fiber ring laser(EDFL) using a single fiber Bragg grating(FBG) and two coil heaters is proposed and demonstrated. Installing two identical coils into a single FBG, the FBG is symmetrically divided into two different portions. While a current supply to the coil, the refractive index of the FBG under the coil is changed. The FBG can operate as a joint of two different FBGs. Due to the thermo-optic effect of a fiber, the resonance wavelength split into two peaks. The spacing between two adjacent channels was changed as much as the difference of heating power. It was tuned up to 3 nm of wavelength under the electrical power with a 1000 mW. Moreover, the lasing wavelength can be individually tuned without influencing to the adjacent channel.

A Study on Two-wavelength Digital Holography Using the Fresnel-Bluestein Transform (프레즈넬-불루스타인 변환을 이용한 2파장 디지털 홀로그래픽 연구)

  • Shin, Sanghoon;Kim, Doocheol;Yu, Younghun
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.6
    • /
    • pp.251-254
    • /
    • 2012
  • Dual-wavelength holography has a better axial range than single-wavelength holography, allowing unambiguous phase imaging. The size of a reconstructed image depends on the reconstruction distance and wavelength. The two phase image sizes of different wavelength holograms should be the same in order to apply dual-wavelength holography. The Fresnel-Bluestein transform method is proposed to eliminate the dependence on the reconstruction distance and wavelength. We found that the Fresnel-Bluestein transform is very useful for making different reconstructed image sizes experimentally. Also we applied the Fresnel-Bluestein transform to make the same reconstruction image size in dual wavelength holography.

High Power Switchable Dual-Wavelength Linear Polarized Yb-Dozped Fiber Laser around 1120 nm

  • Liu, Xiaojuan;Huang, Bangcai;Wei, Gongxiang;Han, Kezhen;Huang, Yan;Liu, Fangfang
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.716-721
    • /
    • 2016
  • A single-and dual-wavelength switchable polarized Yb-doped double-clad fiber laser around 1120 nm based on a pair of fiber Bragg gratings (FBGs) is demonstrated. The polarization-maintaining (PM) linear cavity is composed of a double clad PM Yb-doped fiber (YDF) and a pair of PM FBGs. The laser can operate in stable dual-wavelength or wavelength-switching modes due to the polarization hole burning (PHB) and the spatial hole burning (SHB) enhanced by the PM linear cavity. In dual-wavelength operation, the two orthogonally polarized wavelengths are centered at 1118.912 nm and 1119.152 nm, with an interval of 0.24 nm and a signal to noise ratio (SNR) of 35 dB. The maximum output power is 14.67 W when the launched LD pump is 24 W corresponding to an optical efficiency of 61.1%. The lasing lines switchover may be realized by adjusting the polarization controller (PC) fitted in the cavity. The two single-wavelengths are 1118.912 nm and 1119.152 nm. When the injected LD pump is 24 W, the highest output powers are 7.68 W and 8.64 W corresponding to optical efficiencies of 32% and 36% respectively. The spectral linewidth of the lasing lines are 0.075 nm and 0.07 nm, and the average numerical values of PER aredB and 19.9 dB, respectively.

A Sub-Wavelength Focusing Lens Composed of a Dual-Plate Metamaterial Providing a Negative Refractive Index

  • Kim, Dong-Ho
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.1
    • /
    • pp.26-31
    • /
    • 2012
  • We have proposed a metamaterial lens that enables sub-wavelength focusing, which is shorter than an operating wavelength. Our lens is a two dimensional array of a unit cell consisting of a metallic dual-plate printed on a dielectric substrate. The unique dual-plate structure provides negativeness both in permittivity and permeability, with no help from conventional additional structures, which are normally printed on the opposite of metallic patterns. Therefore, we can focus a source (or an image) in a tiny distance shorter than the free space wavelength (${\lambda}$) at the frequencies of interest. Furthermore, since the proposed geometry does not need separate supplementary structures to acquire negative permittivity or permeability, our lens is much simpler than conventional metamaterial lenses, which is a strong point in practical applications. We have validated sub-wavelength focusing ability in a 6 GHz frequency band through an experiment of near field scanning, which provided the width of about 0.19 ${\lambda}$ at a half maximum of a peak value of an measured image. The width of the focused image through the lens is more than 4 times shorter than that without the lens, which confirms the validity of our design approach.

Dynamic Range Improvement of IM-DD Optical Link using Dual-Wavelength Dual-Parallel Modulation

  • Li, Xianghua;Yang, Chun;Zhou, Zhenghua;Chong, Yuhua
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.330-334
    • /
    • 2014
  • In this paper, we present an incoherent dual-parallel modulation linearized optical link employing two different optical wavelengths. Comparing with previous dual-parallel modulation, this linearization method prevents the recreation of distortion products and can be readily implemented. Furthermore, a dual-wavelength dual-parallel modulation linearized optical link constructed with the commercially available devices is experimentally demonstrated with a spurious-free dynamic range of $122.5dB.Hz^{4/5}$. More than 25 dB suppression of the intermodulation distortion, 15.6 dB improvement of spurious-free dynamic range and 1.5 dB improvement of compression dynamic range are achieved after linearization.

Acquirement of cross-sectional image by using wavelength swept laser within the two SOAs parallel configuration (병렬 SOA 구조의 파장가변 레이저를 이용한 단면 영상획득)

  • Kim, Hoon-Sup;Eom, Jin-Seob
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.239-244
    • /
    • 2008
  • We have realized the swept source optical coherence tomography(SS-OCT) by using the self-fabricated wavelength swept laser(wavelength tuning range : 80nm, line-width : 0.12nm, wavelength sweeping rate : 50Hz). In addition, we have used the dual balanced detector that could make a mirror image in OCT display suppressed. We can also fabricate the comb filter of Michelson interferometer type for fast-signal processing in OCT. Using this SS-OCT system for measuring an mirror, a 1mm-depth glass and an onion, we confirmed that the in vivo epidermal cross-sectional images for them can be obtained appropriately.

  • PDF

Dual Wavelength Erbium-doped Fiber Laser with Lasing Wavelength Switchability and Tunability (파장 가변 및 스위칭이 가능한 쌍파장 어븀 첨가 광섬유 레이저)

  • Park, Sang-Oh;Shim, Young-Bo;Yoon, Min-Seok;Chu, Su-Ho;Kim, Hyun-Joo;Kwon, Oh-Jang;Han, Young-Geun
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.5
    • /
    • pp.181-184
    • /
    • 2010
  • A simple technique for a flexibly tunable and switchable dual wavelength-switchable erbium-doped fiber (EDF) laser using fiber Bragg gratings is proposed and demonstrated by using both linear cavity loss controlling and homogeneous gain broadening of the EDF. The oscillating wavelength switching is successfully realized by using the modulation of the acousto-optic modulator driven by the RF signal. The wavelength spacing and lasing wavelength of the proposed wavelength-switchable laser can also be controlled by using the bending-induced tension or compression strain. The proposed tunable dual wavelength-switchable fiber laser has a lot of advantages, such as a high extinction ratio larger than 40dB and a high tunability of ~7.2 nm/$m^{-1}$.

Three-dimensional Information and Refractive Index Measurement Using a Dual-wavelength Digital Holographic

  • Shin, Sang-Hoon;Yu, Young-Hun
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.173-177
    • /
    • 2009
  • Digital holographic microscopy allows optical path difference measurement. Optical path difference depends on the both refractive index and morphology of sample. We developed a dual-wavelength in-line digital holographic microscope that can measure simultaneously the refractive index and morphology of a sample, providing highly precise three-dimensional information. Here we propose theoretical and experimental methods for dual-wavelength in-line digital holographic microscopy. The measured data were reasonable, although there was data error. By improving the experimental method, we could measure the refractive index more precisely and obtain more accurate three-dimensional information on samples.