• Title/Summary/Keyword: dual system

Search Result 2,715, Processing Time 0.03 seconds

Fault Tolerant Control Methods for Dual Type Independent Multi-Phase BLDC Motor under the Open-Switch Fault Conditions

  • Kim, Yong-Hyu;Heo, Hong-Jun;Park, June-Ho;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.722-732
    • /
    • 2018
  • Dual type Independent multi-phase BLDC Motor (DI-BLDCM) is designed to be robust to faulty conditions of motor and drive system. Despite the efforts of the motor design, open-switch faults of DI-BLDCM drive system cause the torque ripple of the motor. This torque ripple makes unwanted sound noise and mechanical vibration of associated systems. This paper proposes four methods for compensating the torque ripple and compares the characteristics of each proposed method. All proposed methods are able to reduce the torque ripple to similar level of the healthy condition, although the motor operates in open-switch fault conditions. However, these methods have different characteristics in various fault conditions. Therefore, from the results of the comparison, the suitable method is selected for the various fault conditions. The feasibility of the proposed methods is proved by the several experimental results.

The Mechanical Characteristic Analysis and Improvement of Precision Position Control System with AC Servo Motor and Ball Screw (AC Servo Motor와 Ball screw를 이용한 정밀 위치제어시스템의 기계적 특성 분석 및 개선)

  • Ko, Su-Chang;Jin, Kyoung-Bog
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.1 s.18
    • /
    • pp.31-36
    • /
    • 2007
  • Effect of coulomb friction and backlash on the single loop position control has been studied for the precision position control. We have showed the limit cycle on the single loop system which used a ball screw that had the backlash. Also, we have made an inner loop with a classical velocity and torque controller which was forcing the current of d axis to be zero by using a permanent-magnet synchronous motor and composed the outer loop with linear encoder for sensing a position of the loader. Also, we have used least squares fit(LSF) observer for reducing noise when we got velocity from position outputs. We have shown a good result by using the dual loop through simulation and experiment.

  • PDF

Dual structured tap selection algorithm for echo canceller (반향제거기용 이중 구조 탭선택 알고리즘)

  • 오돈성;이두수
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.4
    • /
    • pp.18-26
    • /
    • 1996
  • In this paper we propose a new dual structured tap selection algorithm for voice echo canceller in digital cellular communication system, investigating adaptive filtering algorithms for echo cancellation in long distance telephony or mobile communication system. The proposed algorithm has a two-stage processing structure that after a dispersive region in an impulse response of an echo path is found out, the tap coefficients of a short length filter are adjusted adaptively for the region, because the impuse response has a very little portion of the dispersion. Simulation results show that the proposed algorithm with 256 taps gives a performance of convergence speed superior to both full-tap normalized least mean with 256 taps gives a performance of convergence speed superior to both full-tap normalized least mean square (NLMS) and a scrub taps waiting in a queue (STWQ) algorithms by about eighty per cent, also to a tap selection algorithm by about twenty per cent. And the resutls diplay that if the more tap coefficients are used due to a long delayed dispersive zone, the proposed algorithm produces the better performance.

  • PDF

Study on the Reliability Analysis for Fault-Tolerant Dual Ethernet (고장극복 기능이 있는 이중망의 신뢰도 분석에 대한 연구)

  • Kim, Hyun-Sil
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.107-114
    • /
    • 2007
  • This paper describes the Petri Net(PN) model for reliability analysis of fault-tolerant dual Ethernet which Is applied in Naval Combat System. The network for Naval Combat System performs failure detection and auto path recovery by handling redundant path in case of temporary link failure. After studying the behavior of this kind of network, the reliability analysis model is proposed using stochastic Petri Net and continuous-time Markov chains. Finally, the numerical result is analyzed according to changing the failure rate and the recover rate of link.

The Proportional Resonant Controller for Improving the Current Distortion of the Dual buck inverter in DCM Section Connected grid system with harmonic voltage (고조파 전압이 포함된 계통과 연계된 듀얼벅 인버터의 DCM 구간에서 전류 왜곡 개선을 위한 비례공진 제어기)

  • Choi, Minjae;Cho, Younghoon;Choi, Jinuk;Moon, Youngmin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.286-287
    • /
    • 2018
  • Recently, the development of renewable energy using solar energy is drawing attention. One of these PV systems, the Dual buck Inverter, is one of the topologies used in conjunction with the system, characterized by high efficiency and shoot-through reduction. However, current distortion appears severely in grid connection. So, in this paper, the method of compensation through PR controller was verified through simulation as an analysis of current distortion components and a control method to improve them.

  • PDF

A Dual Radiation Monitoring System Ror Robot Working in High Radiation Field (고방사선장내 작업 로봇용 이중 방사선 감지 시스템)

  • Lee Nam-Ho;Cho Jai-Wan;Kim Seung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.9
    • /
    • pp.556-558
    • /
    • 2005
  • The effect of high irradiation on inspection systems in a nuclear power plant can be severe, especially to electronic components such as control hoards. The effect may lead to a critical malfunction or trouble to a underwater robot for inspection and maintenance of nuclear reactor. However, if information on the total accumulated dose on the sensitive parts of the robot is available, a prediction of robot's behavior in radiation environments becomes possible. To know how much radiation the robot has encountered, a dosimeter to measure the total accumulated dose is necessary. This paper describes the development effort of a dual radiation monitoring system using a SiC diode as a dose-rate meter and a p-type power MOSFET as a dose meter. This attempt using two sensors which detect same radiation improves reliability and stability at high intensity radiation detection in nuclear facilities. It uses the concept of diversity and redundancy.

Using Double Photon Transmission of Quantum Cryptography (이중광자 전송을 통한 양자비밀통신)

  • Seol, Jung-Ja;Rim, Kwang-Cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.8
    • /
    • pp.1857-1864
    • /
    • 2013
  • In this paper, we improve the quantum cryptography system using a dual photon transmission plaintext user password algorithmwas designed to implementthe exchange. Existing quantum cryptographic key transport protocols, algorithms, mainly as a quantum cryptography system using the paper, but it improved the way the dual photon transmission through the quantum algorithm re not getting transmitted plaintext.

Dual Compressor Inverter System for Refrigerator Vehicles (냉장 차량용 듀얼 컴프레서 인버터 시스템)

  • Han, Keun-Woo;Kim, Seong-Gon;Lee, Chung-Hoon;Choi, Myoung-Hyun;Jung, Young-Gook
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.292-293
    • /
    • 2017
  • In the single type mechanical compressor mounted on the refrigerated vehicle, one compressor is responsible for the refrigerator function of the air conditioner and the refrigerator, so it is difficult to maintain a certain refrigeration temperature in the summer. Particularly, in a mechanical compressor using an engine as a power source, the refrigeration quality is deteriorated due to unstable rotation of the engine. In this paper, we propose a three - phase inverter of a dual compressor system that uses an electric compressor separately from a mechanical compressor of a refrigerated vehicle. The output characteristics of the developed inverter were verified through a vehicle air conditioning simulator.

  • PDF

Development of optical dual-sensors for submersion monitoring using zigbee-based wireless sensor networks (지그비 기반 센서 네트워크를 이용한 침수감지용 광 이중센서 개발)

  • Key, Kwang-Hyun;Kim, Hyung-Pyo;Sohn, Kyung-Rak
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.184-190
    • /
    • 2010
  • In this paper, a remote submersion warning system based on multi-mode optical fiber(MMF) sensors and a wireless sensor network(WSN) are proposed. To improve the reliability and stability of the sensors, the dual optical fiber sensors combined to the optical coupler are demonstrated. A slave zigbee as a wireless sensor module was used as a platform to monitor and record the signal from the MMF sensors and then transmits these information to a master zigbee wirelessly. The monitoring system running the $LabVIEW^{(R)}$ software was connected to the internet to support the short message service(SMS) through extensible markup language(XML) web service. No matter where the managers are, they can always receive the real-time remote-monitoring data for safety check.

Dual Capillary Column System for the Qualitative Gas Chromatography: 1. Comparison Between Split and Splitless Injection Modes

  • Kim, Kyoung-Rae;Kim, Jung-Han;Park, Hyoung-Kook;Oh, Chang-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.1
    • /
    • pp.87-92
    • /
    • 1991
  • A dual capillary column system is described for the simultaneous measurement of retention index (RI) and area ratio (AR) values of each peak on two capillary columns of different polarity, DB-5 & DB-1701. Both capillary columns were connected to a common splitless injector via a deactivated fused-silica capillary tubing of 1 m length and a 'Y' splitter, the dead volume effect of which was found to be negligible. RI and AR were measured with high reproducibility(${\leq}$0.05% RSD) and with high accuracy (<10% RE), respectively. When applied to the test samples of the organic acid mixture, each acid was positively identified by the combined computer RI library search-AR comparison.