• Title/Summary/Keyword: dual sensing

Search Result 151, Processing Time 0.03 seconds

Development of a Wideband Power Sensor for the Measurement of Wireless Power (무선 주파수 전력 측정을 위한 광대역 전력 센서 개발)

  • Hwang, Mun-Su;Na, In-Ho;Gu, Ja-Gyeong;Lim, Jong-Sik;Ahn, Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3600-3607
    • /
    • 2009
  • This paper describes the development of a power sensor for wireless signal over the ultra wideband range of 300~3800MHz with the detecting range of 150mW~150W. The proposed power sensor fundamentally has the function of not only detecting wireless power, but recognizing frequency and measuring VSWR. The development of the power sensor is completed through the design of dual directional coupler, design of power detector block which produces DC data using the corresponding RF input power level, and establishment of collecting the exact calibration data. The dual directional coupler has the operating frequency of 300~3800MHz with the 0.085dB of insertion loss, and directivity of 30dB at least at 3800MHz. The developed power sensor has the capability of power sensing with less than 0.25dB of resolution as well as measuring VSWR of 1.17~1.96 under the practical operating situation of very high power up to 150W at 300~3800MHz.

Imaging Performance Analysis of an EO/IR Dual Band Airborne Camera

  • Lee, Jun-Ho;Jung, Yong-Suk;Ryoo, Seung-Yeol;Kim, Young-Ju;Park, Byong-Ug;Kim, Hyun-Jung;Youn, Sung-Kie;Park, Kwang-Woo;Lee, Haeng-Bok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.174-181
    • /
    • 2011
  • An airborne sensor is developed for remote sensing on an aerial vehicle (UV). The sensor is an optical payload for an eletro-optical/infrared (EO/IR) dual band camera that combines visible and IR imaging capabilities in a compact and lightweight package. It adopts a Ritchey-Chr$\'{e}$tien telescope for the common front end optics with several relay optics that divide and deliver EO and IR bands to a charge-coupled-device (CCD) and an IR detector, respectively. The EO/IR camera for dual bands is mounted on a two-axis gimbal that provides stabilized imaging and precision pointing in both the along and cross-track directions. We first investigate the mechanical deformations, displacements and stress of the EO/IR camera through finite element analysis (FEA) for five cases: three gravitational effects and two thermal conditions. For investigating gravitational effects, one gravitational acceleration (1 g) is given along each of the +x, +y and +z directions. The two thermal conditions are the overall temperature change to $30^{\circ}C$ from $20^{\circ}C$ and the temperature gradient across the primary mirror pupil from $-5^{\circ}C$ to $+5^{\circ}C$. Optical performance, represented by the modulation transfer function (MTF), is then predicted by integrating the FEA results into optics design/analysis software. This analysis shows the IR channel can sustain imaging performance as good as designed, i.e., MTF 38% at 13 line-pairs-per-mm (lpm), with refocus capability. Similarly, the EO channel can keep the designed performance (MTF 73% at 27.3 lpm) except in the case of the overall temperature change, in which the EO channel experiences slight performance degradation (MTF 16% drop) for $20^{\circ}C$ overall temperate change.

Position Uncertainty due to Multi-scattering in the Scintillator Array of Dual Collimation Camera (복합 집속 카메라의 섬광체배열에서 다중산란에 의한 위치 불확실성)

  • Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.287-292
    • /
    • 2008
  • Position information of radiation interactions in detection material is essential to reconstruct a radiation source image. With most position sensing techniques, the position information of a single interaction inside the detectors can be precisely obtained. Each interaction position of multi-scattering inside scintillators, however, can not be individually measured and only the average of the scattering positions can be obtained, which causes the uncertainty in the measured interaction position. In this paper, the position uncertainties due to the multi-scattering were calculated by Monte Carlo simulation. The simulation model was a 50 by 50 by 5 mm $LaCl_3$(Ce) scintillator(pixel size is 2 by 2 by 5mm) which was utilized for the dual collimation camera. The dual collimation camera uses the information from both photoelectric effect and Compton scattering, and therefore, position uncertainties for both partial and full energy deposition of radiation interactions are calculated. In the case of partial energy deposition(PED), the standard deviations of positions are less than $1{\sim}2mm$, which means the uncertainty caused by multi-scattering is not significant. Because the effect of the multi-scattering with PED is insignificant, the multi-scattering has little effect on the performance of Compton imaging of dual collimation camera. In the case of full energy deposition(FED), however, the standard deviation of the positions is about twice that of the pixel size of the 1stdetector, except for 122keV incident radiations. Therefore, the standard deviations caused by multi-scatterings should be considered in the design of the coded mask of the dual collimation camera to avoid artifact on the reconstructed image. The position uncertainties of the FEDs are much larger than those of the PEDs for all radiation energies and the ratio of PEDs to FEDs increases when the incident radiation energy increases. The position uncertainties of both PEDs and FEDs are dependent on the incident radiation energy.

  • PDF

Estimation of Ultrasonic Attenuation Coefficients in the Frequency Domain using Compressed Sensing (압축 센싱을 이용한 주파수 영역의 초음파 감쇠 지수 예측)

  • Shim, Jaeyoon;Kim, Hyungsuk
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.167-173
    • /
    • 2016
  • Compressed Sensing(CS) is the theory that can recover signals which are sampled below the Nyquist sampling rate to original analog signals. In this paper, we propose the estimation algorithm of ultrasonic attenuation coefficients in the frequency domain using CS. While most estimation algorithms transform the time-domain signals into the frequency-domain using the Fourier transform, the proposed method directly utilize the spectral information in the recovery process by the basis matrix without the completely recovered signals in the time domain. We apply three transform bases for sparsifying and estimate the attenuation coefficients using the Centroid Downshift method with Dual-reference diffraction compensation technique. The estimation accuracy and execution time are compared for each basis matrix. Computer simulation results show that the DCT basis matrix exhibits less than 0.35% estimation error for the compressive ratio of 50% and about 6% average error for the compressive ratio of 70%. The proposed method which directly extracts frequency information from the CS signals can be extended to estimating for other ultrasonic parameters in the Quantitative Ultrasound (QUS) Analysis.

Accuracy Evaluation of Composite Hybrid Surface Rainfall (HSR) Using KMA Weather Radar Network (기상청 기상레이더 관측망을 이용한 합성 하이브리드 고도면 강우량(HSR)의 정확도 검증)

  • Lyu, Geunsu;Jung, Sung-Hwa;Oh, Young-a;Park, Hong-Mok;Lee, GyuWon
    • Journal of the Korean earth science society
    • /
    • v.38 no.7
    • /
    • pp.496-510
    • /
    • 2017
  • This study presents a new nationwide quantitative precipitation estimation (QPE) based on the hybrid surface rainfall (HSR) technique using the weather radar network of Korea Meteorological Administration (KMA). This new nationwide HSR is characterized by the synthesis of reflectivity at the hybrid surface that is not affected by ground clutter, beam blockage, non-meteorological echoes, and bright band. The nationwide HSR is classified into static (STATIC) and dynamic HSR (DYNAMIC) mosaic depending on employing a quality control process, which is based on the fuzzy logic approach for single-polarization radar and the spatial texture technique for dual-polarization radar. The STATIC and DYNAMIC were evaluated by comparing with official and operational radar rainfall mosaic (MOSAIC) of KMA for 10 rainfall events from May to October 2014. The correlation coefficients within the block region of STATIC, DYNAMIC and MOSAIC are 0.52, 0.78, and 0.69, respectively, and their mean relative errors are 34.08, 30.08, and 40.71%.

A Low-power EEPROM design for UHF RFID tag chip (UHF RFID 태그 칩용 저전력 EEPROM설계)

  • Yi, Won-Jae;Lee, Jae-Hyung;Park, Kyung-Hwan;Lee, Jung-Hwan;Lim, Gyu-Ho;Kang, Hyung-Geun;Ko, Bong-Jin;Park, Mu-Hun;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.3
    • /
    • pp.486-495
    • /
    • 2006
  • In this paper, a low-power 1Kb synchronous EEPROM is designed with flash cells for passive UHF RFID tag chips. To make a low-power EEPROM, four techniques are newly proposed. Firstly, dual power supply voltages VDD(1.5V) and VDDP(2.5V), are used. Secondly, CKE signal is used to remove switching current due to clocking of synchronous circuits. Thirdly, a low-speed but low-power sensing scheme using clocked inverters is used instead of the conventional current sensing method. Lastly, the low-voltage, VDD for the reference voltage generator is supplied by using the Voltage-up converter in write cycle. An EEPROM is fabricated with the $0.25{\mu}m$ EEPROM process. Simulation results show that power dissipations are $4.25{\mu}W$ in the read cycle and $25{\mu}W$ in the write cycle, respectively. The layout area is $646.3\times657.68{\mu}m^2$.

Position Estimation for the Permanent Magnet Spherical Motor using Optical Image Sensor (이미지 센서를 이용한 영구자석 구형모터의 위치 추정)

  • Oh, Ye-Jun;Lee, Won-Kook;Lee, Ho-Jun;Kang, Dong-Woo;Won, Sung-Hong;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.943-944
    • /
    • 2011
  • The position of the rotor in a spherical motor is usually measured by encoders. When using a encoder, It is possible to measure the angle in a very high resolution. However it is limited to measure a single-DOF using one encoder. So it is required to use 3 encoders to measure a 3-DOF. In order to connect the encoder and the motor, an additional mechanic linkages. Because of these reasons, it is difficult to apply it in various systems. Where the friction and inertia is increased when operating the motor. It could cause a negative effect in dynamic characteristic. In this paper present dual-image sensing system capable of measuring 3-DOF motions in real time eliminating the mechanical linkages. In addition we offer methods of converting sensors outputs to rotation angle which is used in the controller.

  • PDF

CALIBRATION ISSUES OF SPACEBORNE MICROWAVE RADIOMETER DREAM ON STSAT-2

  • Singh, Manoj Kumar;Kim, Sung-Hyun;Chae, Chun-Sik;Lee, Ho-Jin;Park, Jong-Oh;Sim, Eun-Sup;Zhang, De-Hai;Jiang, Jing-Shan;Kim, Yong-Hoon
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.398-401
    • /
    • 2006
  • Dual channel Radiometer for Earth and Atmospheric Monitoring (DREAM) is the main payload on Science and Technology SATellite-2 (STSAT-2) of Korea. DREAM is two-channel microwave radiometer with linear polarization, and operating at center frequencies of 23.8 GHz and 37 GHz. An equation for DREAM calibration is derived which accounts for losses and re-radiation in the microwave components of the radiometer due to physical temperature. This paper describes the radiometric calibration equation to get antenna temperature ($T_A$) from the measured output data. At lower altitude, the measured deep space temperature is contaminated by middle atmosphere and earth radiation. In this paper, we presented the detail mathematical formulation to find the altitude up to which cold source brightness temperature is not affected by earth and middle atmosphere radiation. The DREAMPFM data is used to calculate the performance parameters (linearity, sensitivity, dynamic range, and etc.) of the system.

  • PDF

Prediction of rice growth parameters by X-band automatic scatterometer system (X-band 자동관측시스템을 이용한 벼 생육인자 추정)

  • Kim, Yi-Hyun;Hong, S.Young;Choe, Eun-Young;Lee, Hoon-Yol
    • Proceedings of the KSRS Conference
    • /
    • 2009.03a
    • /
    • pp.40-45
    • /
    • 2009
  • 본 연구에서는 기후 등의 영향을 받지 않고 레이더 산란 측정을 할 수 있는 X-band antenna 기반의 자동관측 시스템을 이용하여 벼 생육시기에 따른 후방산란계수와 벼 생육인자와의 관계를 분석하여 후방산란계수를 이용한 벼 생육인자를 추정한 것을 목적으로 하였다. 2008년도 국립농업과학원 시험포장 ($37^{\circ}$15'28.0"N, $126^{\circ}$59'21.5"E)에서 추청벼를 대상으로 생육시기별 후방산란계수를 관측하였는데 모든 편파별 후방산란계수가 벼 유수형성기 (7월 말경)까지 증가하다가 그 후 감소하다가 수확기가 가까워지는 9월 중순이후 다시 증가하는 dual-peak 현상을 보였고 특히 W-편파의 경우 9월 초순부터 후방산란계수 증가가 다른 polarization에 비해 크게 나타났다. 후방산란계수와 작물생육인자와의 관계를 분석한 결과 고주파수인 X-band는 상대적으로 바이오메스, 엽 면적지수와의 상관이 낮게 나타났지만 이삭 건물중은 VV-편파 후방산란계수와 상관관계를 보였다. 이삭 건물중과 상관관계가 높게 나타난 X-band의 W-편파 후방산란계수를 이용하여 수확기 이삭 건물중을 추정하였는데 VV-편파 후방산란계수와 이삭 건물중과는 결정계수 $(R^2)$가 0.85이었고, 이삭 건물중 실측값과 추정값을 비교해 본 결과 1:1 line에 근접하게 분포하였다 ($R^2$=0.85).

  • PDF

Water level fluctuations of the Tonle Sap derived from ALOS PALSAR

  • Choi, Jung-Hyun;Trung, Nguyen Van;Won, Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.188-191
    • /
    • 2008
  • The Tonle Sap, Cambodia, is a huge lake and periodically flooded due to monsoon climate. The incoming water causes intensive flooding that expands the lake over vast floodplain and wetland consisting mainly of forests and shrubs. Monitoring the water-level change over the floodplain is essential for flood prediction and water resource management. A main objective of this study is flood monitoring over Tonle Sap area using ALOS PALSAR. To study double-bounce effects in the lake, backscattering effect using ALOS PALSAR dual-polarization (HH, HV) data was examined. InSAR technique was applied for detection of water-level change. HH-polarization interferometric pairs between wet and dry seasons were best to measure water level change around northwestern parts of Tonle Sap. The seasonal pattern of water-level variations in Tonle Sap studied by InSAR method is similar to the past and altimeter data. However, water level variation measured by SAR was much smaller than that by altimeter because the DInSAR measurement only represents water level change at a given region of floodplain while altimeter provides water level variation at the central parts of the lake.

  • PDF