• Title/Summary/Keyword: dual detection

Search Result 293, Processing Time 0.031 seconds

Detection of 10-GHz Optical Single-/Double-Sideband Labels Using Fiber-Optic Interleavers (광섬유 인터리버를 이용한 10-GHz 광 단측파대/양측파대 레이블 검출)

  • Park, Kyoung-Deuk;Shin, Jong-Dug;Kim, Boo-Gyoun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.7C
    • /
    • pp.652-657
    • /
    • 2007
  • Optical subcarrier-multiplexed (OSCM) labels in optical label switching networks have been detected using interleavers composed of fiber-optic Mach-Zehnder interferometer. 10-GHz optical single-/double-sideband signals generated from dual-electrode Mach-Zehnder intensity modulator have been used as the OSCM labels. In the case of single-sideband signals, the upper-sideband was observed to be suppressed about 16.8 dB compared with the lower-sideband from the optical spectrum measured at the label extraction output. For the case of double-sideband signals, both sidebands appeared with small insertion loss at the interleaver output. Since we used the phase-shift method to generate single-sideband signals, the power level of the single-sideband was higher by 3 dB than that of the double-sidebands.

Peptide Nucleic Acid Probe-Based Analysis as a New Detection Method for Clarithromycin Resistance in Helicobacter pylori

  • Jung, Da Hyun;Kim, Jie-Hyun;Jeong, Su Jin;Park, Soon Young;Kang, Il-Mo;Lee, Kyoung Hwa;Song, Young Goo
    • Gut and Liver
    • /
    • v.12 no.6
    • /
    • pp.641-647
    • /
    • 2018
  • Background/Aims: Helicobacter pylori eradication rates are decreasing because of increases in clarithromycin resistance. Thus, finding an easy and accurate method of detecting clarithromycin resistance is important. Methods: We evaluated 70 H. pylori isolates from Korean patients. Dual-labeled peptide nucleic acid (PNA) probes were designed to detect resistance associated with point mutations in 23S ribosomal ribonucleic acid gene domain V (A2142G, A2143G, and T2182C). Data were analyzed by probe-based fluorescence melting curve analysis based on probe-target dissociation temperatures and compared with Sanger sequencing. Results: Among 70 H. pylori isolates, 0, 16, and 58 isolates contained A2142G, A2143G, and T2182C mutations, respectively. PNA probe-based analysis exhibited 100.0% positive predictive values for A2142G and A2143G and a 98.3% positive predictive value for T2182C. PNA probe-based analysis results correlated with 98.6% of Sanger sequencing results (${\kappa}$-value=0.990; standard error, 0.010). Conclusions: H. pylori clarithromycin resistance can be easily and accurately assessed by dual-labeled PNA probe-based melting curve analysis if probes are used based on the appropriate resistance-related mutations. This method is fast, simple, accurate, and adaptable for clinical samples. It may help clinicians choose a precise eradication regimen.

Does Simultaneous Computed Tomography and Quantitative Computed Tomography Show Better Prescription Rate than Dual-energy X-ray Absorptiometry for Osteoporotic Hip Fracture?

  • Ko, Jae Han;Lim, Suhan;Lee, Young Han;Yang, Ick Hwan;Kam, Jin Hwa;Park, Kwan Kyu
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.233-240
    • /
    • 2018
  • Purpose: This study aimed to evaluate the efficacy of simultaneous computed tomography (CT) and quantitative CT (QCT) in patients with osteoporotic hip fracture (OHF) by analyzing the osteoporosis detection rate and physician prescription rate in comparison with those of conventional dual-energy X-ray absorptiometry (DXA). Materials and Methods: This study included consecutive patients older than 65 years who underwent internal fixation or hip arthroplasty for OHF between February and May 2015. The patients were assigned to either the QCT (47 patients) or DXA group (51 patients). The patients in the QCT group underwent QCT with hip CT, whereas those in the DXA group underwent DXA after surgery, before discharge, or in the outpatient clinic. In both groups, the patients received osteoporosis medication according to their QCT or DXA results. The osteoporosis evaluation rate and prescription rate were determined at discharge, postoperative (PO) day 2, PO day 6, and PO week 12 during an outpatient clinic visit. Results: The osteoporosis evaluation rate at PO week 12 was 70.6% (36 of 51 patients) in the DXA group and 100% in the QCT group (P<0.01). The prescription rates of osteoporosis medication at discharge were 70.2% and 29.4% (P<0.001) and the cumulative prescription rates at PO week 12 were 87.2% and 60.8% (P=0.003) in the QCT and DXA groups, respectively. Conclusion: Simultaneous CT and QCT significantly increased the evaluation and prescription rates in patients with OHF and may enable appropriate and consistent prescription of osteoporosis medication, which may eventually lead to patients' medication compliance.

Welding Bead Detection Inspection Using the Brightness Value of Vertical and Horizontal Direction (수직 및 수평 방향의 밝깃값을 이용한 용접 비드 검출 검사)

  • Jae Eun Lee;Jong-Nam Kim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.4
    • /
    • pp.241-248
    • /
    • 2022
  • Shear Reinforcement of Dual Anchorage(SRD) is used to reinforce the safety of reinforced concrete structures at construction sites. Welding is used to make shear reinforcement, and welding plays an important role in determining productivity and competitiveness of products. Therefore, a weld bead detection inspection is required. In this paper, we suggest an algorithm for inspecting welding beads using image data of welding beads. First, the proposed algorithm calculates a brightness value in a vertical direction in an image, and then divides a welding bead in a vertical direction by finding a position corresponding to a 50% height point of the brightness value distribution in the image. The welding bead area is also divided in the same way for the horizontal direction, and then the segmentation image is analyzed if there is a welding bead. The proposed algorithm reduced the amount of computation by performing analysis after specifying the region of interest. In addition, accuracy could be improved by using all brightness values in the vertical and horizontal directions using the difference of brightness between the base metal and the welding bead region in the SRD image. The experiment compared the analysis results using five algorithms, such as K-mean and K-neighborhood, as a method to detect if there is a welding bead, and the experimental result proved that the proposed algorithm was the most accurate.

Position Uncertainty due to Multi-scattering in the Scintillator Array of Dual Collimation Camera (복합 집속 카메라의 섬광체배열에서 다중산란에 의한 위치 불확실성)

  • Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.287-292
    • /
    • 2008
  • Position information of radiation interactions in detection material is essential to reconstruct a radiation source image. With most position sensing techniques, the position information of a single interaction inside the detectors can be precisely obtained. Each interaction position of multi-scattering inside scintillators, however, can not be individually measured and only the average of the scattering positions can be obtained, which causes the uncertainty in the measured interaction position. In this paper, the position uncertainties due to the multi-scattering were calculated by Monte Carlo simulation. The simulation model was a 50 by 50 by 5 mm $LaCl_3$(Ce) scintillator(pixel size is 2 by 2 by 5mm) which was utilized for the dual collimation camera. The dual collimation camera uses the information from both photoelectric effect and Compton scattering, and therefore, position uncertainties for both partial and full energy deposition of radiation interactions are calculated. In the case of partial energy deposition(PED), the standard deviations of positions are less than $1{\sim}2mm$, which means the uncertainty caused by multi-scattering is not significant. Because the effect of the multi-scattering with PED is insignificant, the multi-scattering has little effect on the performance of Compton imaging of dual collimation camera. In the case of full energy deposition(FED), however, the standard deviation of the positions is about twice that of the pixel size of the 1stdetector, except for 122keV incident radiations. Therefore, the standard deviations caused by multi-scatterings should be considered in the design of the coded mask of the dual collimation camera to avoid artifact on the reconstructed image. The position uncertainties of the FEDs are much larger than those of the PEDs for all radiation energies and the ratio of PEDs to FEDs increases when the incident radiation energy increases. The position uncertainties of both PEDs and FEDs are dependent on the incident radiation energy.

  • PDF

Evaluation of p16INK4a/Ki-67 Dual Immunostaining in Liquid-based Cytology for Diagnosis of Uterine Cervical Dysplasia and Cancer (자궁경부 이형성증과 암의 진단을 위한 액상세포 검체에서 p16INK4a/Ki-67 이중면역염색의 평가)

  • Sung, Mi Hee;Lee, Hoon Taek;Shin, Min Shik;Oh, Seo Young;Kim, Wook Youn
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.3
    • /
    • pp.132-139
    • /
    • 2015
  • Recently, $p16^{INK4a}$/Ki-67 dual immunostaining has been introduced as a new biomarker protocol for early detection of uterine cervical dysplasia and cancer in liquid-based cytology (LBC). We performed the $p16^{INK4a}$/Ki-67 dual immunostaining using a CINtec$^{(R)}$ PLUS kit in a total of 109 LBC cases of cervicovaginal smear and compared its results with those from LBC, HPV hybrid capture II (HC II) test and histological diagnosis. Expression of $p16^{INK4a}$ and Ki-67 was significantly associated with cases of LSIL or higher in cytological diagnosis and cases of cervical intraepithelial neoplasia (CIN) 1 or higher in histological diagnosis (p<0.001 and p<0.001, respectively). Among forty-six cases of atypical squamous cells of undetermined significance (ASCUS) in LBC, $p16^{INK4a}$ and Ki-67 was expressed in 31 (67.4%), which were positively associated with cases of CIN I lesion or higher in histology. The sensitivity of $p16^{INK4a}$/Ki-67 dual immunostaining for finding lesions of CIN 1 or higher was 89.0%, which was higher than LBC. The specificity was 73.5%, which was higher than that of the HC II test. Based on these results, the $p16^{INK4a}$/Ki-67 dual immunostaining method can be a useful diagnostic marker for improving the sensitivity of LBC and the specificity of HC II test.

The Inplementation of Fault-Tolerant Dual System Using the Hot-Standby Sparing Technique (핫 스탠바이 스페어링 기법을 이용한 고장 감내 이중화 시스템 설계)

  • Shin Jin wook;Park Dong sun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.10A
    • /
    • pp.1113-1122
    • /
    • 2004
  • This paper is basically to achieve the high-availability and high-reliability of the control system from the implementation of the fault-tolerant system using the hot-standby sparing technique. To meet the objective, we design and implement a board with fault tolerance I/O bus to detect the fault. Warm-standby sparing technique is the fault tolerance technique usually used for switching control system in present. This technique can be easily implemented, but can not detect the fault quickly and can malfunction because of the hardware fault. The hot-standby sparing fault tolerant technique implemented in this paper is consists of dual processor modules and a I/O processor using fault tolerant I/O bus. The proposed method can find the faults as soon as possible, so it can prevent from wrong operation. Also it is possible to normal re-service due to the short recovering time. To implement the fault-tolerant dual system with fault detection be, two daughter, called FTMA and FTIA, boards designed and implemented are applied to the system. And we also simulated the proposed method to verify the high-availability and high-reliability of the control system using Markov process.

Detection of Monosodium Urate Crystal of Hand and Wrist in Suspected Gouty Arthritis Patients on Dual-Energy CT and Relationship with Serum Urate Level (손과 손목의 통풍관절염에서 이중에너지 CT를 이용한 요산나트륨 결정 검출과 혈중 요산 농도와의 관계)

  • Hana Choi;Jeongah Ryu;Seunghun Lee;Yeo Ju Kim;Soyoung Bang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.212-225
    • /
    • 2023
  • Purpose We retrospectively investigated the characteristics of patients with monosodium urate (MSU) deposits of the hand and wrist on dual-energy CT (DECT) compared to those without. We also attempted to determine the pattern of MSU distribution in DECT. Materials and Methods In total, 93 patients were included who had undergone DECT for evaluation of the hand or wrist pain under the clinical impression of gouty arthritis. The total volume of MSU deposits on DECT was calculated and the pattern of MSU distribution on DECT was analyzed. Also, the level of the serum urate at the time of DECT and the highest level of the serum urate of the patients were obtained from their records and the relationship between MSU and serum urate level was evaluated. Results The range of the volume of MSU deposits on DECT was 0.01-16.11 cm3 (average: 1.07 cm3). The average level of serum urate was significantly higher in the MSU positive group than that in the MSU negative group. MSU deposits were most frequently observed in the wrists followed by fingers and digitorum tendons. Conclusion On DECT, MSU deposits were most frequently detected in the wrist and related with high serum urate level.

Determination and confirmation of the carbendazim residue in soybean sprout (콩나물중 살균제 carbendazim 잔류분의 정량 및 확인)

  • Kim, Young-Gook;Park, Jong-Tae;Hong, Suk-Soon
    • The Korean Journal of Pesticide Science
    • /
    • v.2 no.3
    • /
    • pp.79-84
    • /
    • 1998
  • Tandem HPLC and atmospheric pressure chemical ionization(APcI) LC/MS method was used for the determination and confirmation of carbendazim residues in soybean sprout. Fluorescence(FL) detector was connected in tandem with the ultraviolet(UV) detector for dual detection of the carbendazim residue at the excitation and emission wavelength of 280 nm and 310 nm, respectively. The limit of detection for carbendazim was $0.1{\mu}g/kg$ sample. Recoveries of carbendazim from fortified soybean sprout at 0.5, 1.0 and 2.0 ppm were averaged 89.1%. Mass spectrometry using a APcI source confirmed the carbendazim residue in the soybean sprout sample. Fragmentation pattern on the APcI LC/MS spectrum of carbendazim was simpler than that from electron impact(EI) mass spectrum. Carbendazim produced 3 major ions including m/z 133, m/z 159 and m/z 191($M^{+}$). This method was sensitive enough to provide reliable and reproducible results for practical applications.

  • PDF

Comparison of chemiluminescence immunoassay (CIA) and immunochromatography assay(ICA) for Detecting HBsAg and Anti-HBs (B형 간염항원 및 항체 검사를 위한 화학발광면역검사법(CIA)과 면역크로마토그래피법(ICA)의 비교분석)

  • Kim, Hye-Jeong;Kim, Eun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3419-3424
    • /
    • 2013
  • Diverse immunoassays including a chemiluminescent immunoassay (CIA) are used to detect hepatitis B surface antigen (HBsAg) and antibody (anti-HBs). Recently, an increasing number of institutions have been utilizing an immunochromatography assay (ICA), which is easy to use. In this study, We evaluated ICA kits for the rapid detection of HBsAg and anti-HBs by comparing them with a CIA. A total of 120 serum hospital samples, were collected for the whole month, were assayed using ICA kit. The Concordance rate, sensitivity, specificity, positive predictive value and negative predictive value of the ICA for HBsAg based on CIA results were 97%, 97%, 100%, 100%, and 96.8%, respectively. The diagnostic performances of the ICA for Anti-HBs were 90%, 90%, 93.3%, 93.1%, and 90.3%, respectively. The ICA kit failed to detect HBsAg and anti-HBs in low reactive samples. The ICA kits for the rapid detection of HBsAg might be recommended for interpreted with caution and dual analysis in the clinical laboratory.