• 제목/요약/키워드: drops

검색결과 1,123건 처리시간 0.032초

Variation of Floating Potential in the Topside Ionosphere Observed by STSAT-1

  • Lee, Junhyun;Lee, Ensang;Lee, Jaejin;Kim, Khan-Hyuk;Seon, Jongho;Lee, Dong-Hun;Jin, Ho;Kim, Eung-Hyun;Jeon, Hyun-Jin;Lim, Seong-Bin;Kim, Taeyoun;Jang, Jaewoong;Jang, Kyung-Duk;Ryu, Kwangsun
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권4호
    • /
    • pp.311-315
    • /
    • 2014
  • In this study, we investigated the effect of space plasmas on the floating potential variation of a low-altitude, polar-orbiting satellite using the Langmuir Probe (LP) measurement onboard the STSAT-1 spacecraft. We focused on small potential drops, for which the estimation of plasma density and temperature from LP is available. The floating potential varied according to the variations of plasma density and temperature, similar to the previously reported observations. Most of the potential drops occurred around the nightside auroral region. However, unlike the previous studies where large potential drops were observed with the precipitation of auroral electrons, the potential drops occurred before or after the precipitation of auroral electrons. Statistical analysis shows that the potential drops have good correlation with the temperature increase of cold electrons, which suggests the small potential drops be mainly controlled by the cold ionospheric plasmas.

다종의 점안약이 각막염 유발균인 Staphylococcus aureus에 미치는 항균효과에 대한 실험적 연구 (The Experimental Study on Anti-bacterial Potency of Various Herbal Eye drops on Staphylococcus aureus induced keratitis)

  • 서형식
    • 대한약침학회지
    • /
    • 제11권1호
    • /
    • pp.99-107
    • /
    • 2008
  • Objectives : This experimental study was performed to investigate the effect of herbal eye drops(Sean-tang, Jinpi-san, Tangpo-san, Copitdis Rhizoma) on Staphylococcus aureus keratitis. Methods : After administering various herbal eye drops on Staphylococcus aureus, I measured MIC and the size of inhibition zone. MIC was measured by dropping from 20 to $50{\mu}{\ell}$ according to density. Anti-bacterial potency was measured by the size of inhibition zone with change of volume under 2 days culture condition. Also continuous antibacterial potency of herbal eye drops was measured by the size of inhibition zone according to 2 days and 6 days culture each under the $50{\mu}{\ell}$condition. Results : 1. MIC on Staphylococcus aureus in Sean-tang, Jinpi-san and Tangpo-san was 100%, $20{\mu}{\ell}$. 2. MIC on Staphylococcus aureus in Coptidis rhizoma was 10%, $30{\mu}{\ell}$. 3. MIC on Staphylococcus aureus in Cravit was 0.1%, $50{\mu}{\ell}$. 4. Under the 2 days culture condition, the size of inhibition zone on Staphylococcus aureus by volume for Sean-tang was 12.0mm in $50{\mu}{\ell}$, Jinpi-san was 19.0mm in $50{\mu}{\ell}$, Tangpo-san was 15.0mm in $50{\mu}{\ell}$, Coptidis rhizoma was 32.7 mm in $50{\mu}{\ell}$ and Cravit was 31mm in $50{\mu}{\ell}$, Coptidis rhizoma showed the highest anti-bacterial potency. 5. Under the $50{\mu}{\ell}$ condition, the size of inhibition zone on Staphylococcus aureus by 2 and 6 culture days for Sean-tang was 12.0mm, Jinpi-san was 19.0mm, Tangpo-san was 15.0mm, Coptidis rhizoma was 32.7mm and Cravit was 31.0 mm, which showed sameness anti-bacterial potency in 2 days and 6 days. Conclusions : The present author think that the herbal eye drops can be used to cure Staphylococcus aureus keratitis and if further study is performed, the use of the herbal eye drops will be valuable and beneficial in the clinical medicines.

스핀들 모드하의 전기수력학적 미립화를 통한 균일 미세액적 생성 (Generation of uniform Fine Droplets Under Spindle Mode in Electrohydrodynamic Atomization)

  • 이상용;김명찬;김상수;김유동
    • 대한기계학회논문집B
    • /
    • 제25권7호
    • /
    • pp.923-932
    • /
    • 2001
  • A series of experiments were conducted to generate fine liquid(water) drops through the electrohydrodynamic atomization process. The atomization mode depended on flow rate and DC voltage input. For water, having electric conductivity larger than 10(sup)-7S/m, the spindle mode turned out to be the only mode to generate uniform-size drops within the range of 30-450 microns that have wide applications. Within this mode, both the uniformity and the fineness of drops were improved at an optimum voltage input for a given flow rate. This optimum voltage increased with increasing of the liquid flow rate. Another important parameter considered was the nozzle material with different electric conductivity and liquid wettability. A stainless-steel nozzle (the material with high electric conductivity and high liquid wettability) and a silica nozzle (the electrically non-conducting material with low liquid wettability) were tested and compared; and more uniform drops could be obtained with the silica nozzle.

다중 분산부하 전압강하산정 프로그램 연구 (A Study of the Voltage drops computation program on multi-distributed random loads)

  • 강차녕;권세혁;조성필
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.37-42
    • /
    • 2006
  • 전선에서 전압강하는 열 손실을 의미한다. 이 열은 절연체의 특성을 변화시켜 절연성능을 저하시키게 되고 나아가 누전, 감전, 정전 및 화재 등의 사고를 일으키는 원인이 되기도 한다. 그러므로 전압강하에 대한 최적화 설계는 전기설비의 안전성과 경제성을 보장하는 중요한 요소가 되고 있다. 이에 저압의 전기설비인 가로등, 빌딩, 지하철역사 등 공공의 안전확보가 요구되는 다중 분산부하계통에서의 전압강하가 전기배선에 미치는 영향을 분석하고, 안전성 및 경제성 확보를 위한 전압강하산정 프로그램 및 최적화 방안을 연구 제시하고자 한다.

  • PDF

유동층 액-액 추출기에서 액적의 크기 및 상승속도 (Size and Rising Velocity of Liquid Drops in Liquid-Liquid Fluidized-Bed Extractors)

  • 정성현;김재한;강태규;강용;김상돈
    • 공업화학
    • /
    • 제16권1호
    • /
    • pp.34-38
    • /
    • 2005
  • 직경이 0.102 m이고 높이가 2.5 m인 유동층 액-액 추출기에서 액적의 크기와 분포 그리고 상승속도의 특성에 대하여 연구하였다. 분산상(0~0.04 m/s)과 연속상(0.02~0.14 m/s)의 유속변화, 그리고 유동고체 입자의 크기변화(1.0, 2.1, 3.1, 6.0 nm)에 따른 액적의 특성을 검토하였다. 액적의 흐름 거동은 추출기 내부에서 액적의 흐름 거동은 분산상과 연속상의 증가와 액적의 크기에 따라 상당히 영향을 받았다. 액적의 크기는 분산상의 속도가 증가함에 따라 증가하였지만, 유동입자의 크기가 증가함에 따라 따라서는 감소하는 경향을 나타내었다. 그러나 연속상의 유속이 증가함에 따른 액적의 크기는 국부적인 최대값을 나타낸 후 감소하는 경향을 나타내었다. 액적의 크기와 상승속도는 실험변수들과 잘 상관됨을 알 수 있었다.

Various Men's Body Shapes and Drops for Developing Menswear Sizing Systems in the United States

  • HwangShin, Su-Jeong;Istook, Cynthia L.;Lee, Jin-Hee
    • 한국의류학회지
    • /
    • 제35권12호
    • /
    • pp.1454-1465
    • /
    • 2011
  • Menswear body types are often labeled on garments (to indicate how the garments are designed to fit) with indicators of a size category such as regular, portly, and stout, athletic, or big and tall. A drop (relationships between the chest and waist girths) is related to the fit of a tailored suit. However, current standards are not designed for various drops or body types. There is not enough information of categorizing men's body shapes for the apparel sizing systems. In this article, a set of men's data from SizeUSA sizing survey was analyzed to investigate men's body shapes and drops. Factor analysis and a cluster analysis method were used to categorize men's body shapes. In the results, twenty-five variables were selected through the factor analysis and found four factors: girth factor, height factor, torso girth factor, and slope degree factor. According to the factor and cluster analysis, various body shapes were found: Slim Shape (SS - tall ectomorphy), Heavy Shape (HS - athletic, big & tall, endomorphy and mesomorphy), Slant Inverted Triangle Shape (SITS - regular, slight ectomorphy and slight mesomorphy weight range from normal to slightly overweight), Short Round Top Shape (SRTS - portly and stout, endomorphy). Body shapes were related to fitting categories. SS and HS were related to big & tall fitting category. SITS was related to regular. SRTS was related to portly and stout. Shape 1 (31%) and Shape 2 (26%) were related to current big & tall category. Shape 3 (34%) were related to regular. Shape 4 (9%) were in portly and stout category. ASTM D 6240 standard was the only available standard that presented a regular fitting category. Various drops were found within a same chest size group; however, this study revealed great variances of drops by body shape.

영상처리기법을 이용한 분무액적 크기의 측정 (Spray droplet size measurement using image processing technique)

  • 김인구;이상용
    • 대한기계학회논문집
    • /
    • 제12권5호
    • /
    • pp.1121-1129
    • /
    • 1988
  • 본 연구에서는 oil-bath를 이용한 종래의 방법에 의해 얻어진 사진으로 부터 분무액적의 수와 크기를 자동적으로 측정하는 방법을 시도하였다.특히 측정을 효과 적으로 수행하기 위해 한 영상에서 비교적 맣은 분무액적을 측정하는 방법과 붙어있는 액적들이나 이물질 등을 걸러내는데 중점을 두었으며, 아울러 본 연구를 통하여 설정 된 측정방법의 정확도를 검토하였다.

전기수력학적 분무에서 노즐재질이 입경분포에 미치는 영향 (Effect of Nozzle Material on Drop Size Distribution in Electrohydrodynamic Spraying)

  • 김명찬;이상용
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1451-1457
    • /
    • 2002
  • When an aqueous liquid such as water having high electric conductivity and high surface tension is discharged from a nozzle under a strong DC electric field, fine drops ranging from 30 to 450 microns can be obtained only through the spindle mode. In the present study, effects of the electric conductivity and the surface wettability of nozzle materials on formation of drops with this mode were investigated. For that, three nozzles with the same size but with different materials were prepared and tested; a stainless steel needle, and a plain and a metal (gold)-coated (except for the tip portion) silica needles. Uniform drops were obtained with the gold-coated silica nozzle over the wider range of the DC voltage input. That is, formation of the liquid cone and detachment of the liquid spindle (ligament) can be more stabilized and frequent with the needles having high electric conductivity but with low surface wettability at their tips.

Laboratory-scale Experiment and Model Calculation on the Washout Mechanism of Asian Dust Particles

  • Ma, Chang-Jin;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • 제7권3호
    • /
    • pp.161-168
    • /
    • 2013
  • In this study, an investigation was conducted to assess the washout mechanism of Asian dust particles through both laboratory-scale experiment and model calculation. To artificially simulate Asian dust particle, $CaCO_3$ particles were generated inside an experimental chamber. They were then scavenged by the artificial rain drops. The abundant $CaCO_3$ particles scavenged on a rain drop were successively identified by SEM observation. The concentrations of Ca in residual $CaCO_3$ particles on individual droplet were quantified by PIXE analysis. There was a tendency toward a high accumulation of Ca on a relatively small drop (e.g., <1.0 mm diameter). It is thus suggested that smaller rain drops can effectively scavenge a significant amount of Asian dust particles in ambient atmosphere. The numerical estimation can account for 92.1% and 83.2% of Ca that were measured in small (<1.0 mm diameter) and large (>2.0 mm diameter) size drops, respectively.

무진동 조이스틱을 이용한 전동 휠체어 제어에 관한 연구

  • 홍준표;권오상;이응혁;김병수;홍승홍
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1997년도 춘계학술대회논문집
    • /
    • pp.145-149
    • /
    • 1997
  • General joystick using spring only has a vibration when operaor drops the joystick. If it is used as input of motorized wheelchair, its system have a serious problem which operator fall into dangerous situation. Therefore, In this paper proposed non-vibration joustick which control a motorized wheelchair. Non-vibration joystick was designed which return to origin point when operator drops joystick by mistake. Reflected force of non- vibration joystick is defined as addition displacement and variation rate. And each parameter has elasticity of spring and viscosity of DC servo motor. Through simulation for virtual environment, we found two coefficient to return origin point smoothly when a disabled person drops the joystick. In case of larger elastic coefficient of spring than viscous coefficient, we confirmed the result has the equal vibration of general joystick (under-damping). In opposite case, joystick returned to origin point with excessive force. As a application of non-vibration joystick, we experimented wall-following controlling. In this trial, we corroborated that joystick follows smoothly around the corridors.

  • PDF