• Title/Summary/Keyword: drop values

Search Result 390, Processing Time 0.03 seconds

Classification of Size Specifications for the Ready-made Jacket-from 28 years to 35 on the Korean adult male- (신사복 상의제작을 위한 사이즈스팩의 분류-28세에서 35세 우리나라 남성을 대상으로-)

  • 김구자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.8
    • /
    • pp.1090-1098
    • /
    • 1998
  • The purpose of this study was to classify size specifications of the Korean adult male for the men's ready-made garments, especially jacket and dress shirts. By the stratified sampling method, data were collected by the real anthropometric measurement and by the photo-graphic sources. Sample size was 532 subjects as the sample and their age range was from 28 to 35 years old. 66 variables from the direct anthropometric data in total were applied to analyze. ANOVA in SPSS WIN package was applied to the data and the expected frequency distribution of 10.000 men was calculated by the extraction of density function. This study was performed to classify size specifications by the control dimensions and at the same interval of KS-K. The drop values of 15, 12 and 9 have the high coverage rate of 26.00%, 24.29% and 21.06% respectively and are composed of the majority of 71.35% of the subjects. According to the drop values, size specifications and distribution of control and reference dimensions are predicted. About 52.12% of the expected frequency distribution without stature were covered by 12 size specifications.

  • PDF

Size Specifications of Korean Adult Male for the Ready-made Garments (기성복 제작을 위한 성인 남성의 사이즈 스팩의 분류)

  • 김구자;이순원
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.7
    • /
    • pp.1247-1257
    • /
    • 1997
  • The purpose of this study was to classify size specifications of Korean adult male for the men's ready·made garments, especially jacket and dress shirts. Concept of the comfort and fitness has become a major concern in the basic function of the ready-made garments. Data were collected by the real anthropometric measurement and by the photographic sources. Sample size was 1.290 subjects as the sample and their age range was from 19 to 54 pean old by the stratified sampling method. 66 variables from the direct anthropometric data in total were applied to analyze. ANOVA in SAS package was applied to the data and the expected frequency distribution of 10.000 men was calculated by the extraction of density function. Control dimensions for jacket and dress shirts has been designated by Bcorean Apparel Sizing System (KS-K). Therefore this study was performed to classify size specifications by the control dimensions and at the same interval of KS-K. The drop values of 15, 12 and 9 has the high coverage rate of 22.1%, 21.0% and 18.8% respectively and are composed of the majority of 61.9% of the subjects. According to the drop values, size specifications and distribution of control and reference dimensions are predicted. About 65.75% of the expected frequency distribution without stature were covered by 19 size specification.

  • PDF

Experimental and numerical analysis of fatigue behaviour for tubular K-joints

  • Shao, Yong-Bo;Cao, Zhen-Bin
    • Structural Engineering and Mechanics
    • /
    • v.19 no.6
    • /
    • pp.639-652
    • /
    • 2005
  • In this paper, a full-scale K-joint specimen was tested to failure under cyclic combined axial and in-plane bending loads. In the fatigue test, the crack developments were monitored step by step using the alternating current potential drop (ACPD) technique. Using Paris' law, stress intensity factor, which is a fracture parameter to be frequently used by many designers to predict the integrity and residual life of tubular joints, can be obtained from experimental test results of the crack growth rate. Furthermore, a scheme of automatic mesh generation for a cracked K-joint is introduced, and numerical analysis of stress intensity factor for the K-joint specimen has then been carried out. In the finite element analysis, J-integral method is used to estimate the stress intensity factors along the crack front. The numerical stress intensity factor results have been validated through comparing them with the experimental results. The comparison shows that the proposed numerical model can produce reasonably accurate stress intensity factor values. The effects of different crack shapes on the stress intensity factors have also been investigated, and it has been found that semi-ellipse is suitable and accurate to be adopted in numerical analysis for the stress intensity factor. Therefore, the proposed model in this paper is reliable to be used for estimating the stress intensity factor values of cracked tubular K-joints for design purposes.

A Study on the Body Types of Women in the 20's Residing in Shanghai, China (중국 상해지역 20대 전반 여성의 체형연구)

  • Kang, Yeon-Kyung;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.12 no.5
    • /
    • pp.24-38
    • /
    • 2008
  • As an attempt to improve the seaming of clothes exported to China, this study is intended to strengthen the clothing industry in Korea by providing data on the body figures of Chinese women. Direct measurement was conducted on 193 women aged 19-24 residing in Shanghai, China. Then we classified and identified the body types and characteristics of Chinese women based on the drop values suggested by the National Standard of the People's Republic of China(GB/T 1335.2-1997). The following is a summary and conclusion of this study. 1. The following results were obtained by measuring the body sizes of women aged 19-24 living in Shanghai, China. 2. After having conducted a factor analysis on 111 body measurement items, 15 index items, and 11 calculation items, we were able to deduce a total of 6 factors. 3. We categorized the body types of 19-24 year-old women living in Shanghai, China according to the drop values suggested by GB/T 1335.2-1997 where D-type was added to Y, A, B, and C-types for a total of 5 categories. The characteristics of each body type following the body type structure factor are Y-type for slender type, A-type for standard type, B-type for slightly large type, and C-type for obese type.

Performance Improvement on RED Based Gateway in TCP Communication Network

  • Prabhavat, Sumet;Varakulsiripunth, Ruttikorn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.782-787
    • /
    • 2004
  • Internet Engineering Task Force (IETF) has been considering the deployment of the Random Early Detection (RED) in order to avoid the increasing of packet loss rates which caused by an exponential increase in network traffic and buffer overflow. Although RED mechanism can prevent buffer overflow and hence reduce an average values of packet loss rates, but this technique is ineffective in preventing the consecutive drop in the high traffic condition. Moreover, it increases a probability and average number of consecutive dropped packet in the low traffic condition (named as "uncritical condition"). RED mechanism effects to TCP congestion control that build up the consecutive of the unnecessary transmission rate reducing; lead to low utilization on the link and consequently degrade the network performance. To overcome these problems, we have proposed a new mechanism, named as Extended Drop slope RED (ExRED) mechanism, by modifying the traditional RED. The numerical and simulation results show that our proposed mechanism reduces a drop probability in the uncritical condition.

  • PDF

Characteristics on Evaporating Heat Transfer and Pressure Drop of HCs Refrigerants (탄화수소계 냉매의 증발 열전달 및 압력강하 특성)

  • Lee Kwang-Bae;Lee Ho-Saeng;Kim Jae-Dol;Yoon Jung-In
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.681-687
    • /
    • 2005
  • Experimental results for heat transfer characteristic and pressure gradients of HCs refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 during evaporating inside horizontal double pipe heat exchangers are presented. The test sections which has one tube diameter of 12.70 m with 0.86 mm wall thickness, another tube diameter of 9.52 mm with 0.76 mm wall thickness are used for this investigation. The local evaporating heat transfer coefficients of hydrocarbon refrigerants were higher than that of R-22. The average evaporating heat transfer coefficient increased with the increase of the mass flux. It showed the higher values in hydrocarbon refrigerants than R-22. Hydrocarbon refrigerants have higher pressure drop than R-22 in 12.7 mm and 9.52 mm. This results form the investigation can be used in the design of heat transfer exchangers using hydrocarbons as the refrigerant for the air- conditioning systems.

Characteristics on Variation of Temperature and Ozone Concentration during the Partial Solar Eclipse Event of 22 July 2009 at Busan (2009년 7월 22일 부분일식 발생 시 부산지역 기온과 오존농도의 변화 특성)

  • Jeon, Byung-Il;Oh, In-Bo
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.1049-1059
    • /
    • 2011
  • This paper examines the effects of the partial solar eclipse of 22 July 2009 across the Korean peninsular on surface temperature and ozone concentrations in over the Busan metropolitan region (BMR). The observed data in the BMR demonstrated that the solar eclipse phenomenon clearly affects the surface ozone concentration as well as the air temperature. The decrease in temperature ranging from 1.2 to $5.4^{\circ}C$ was observed at 11 meteorological sites during the eclipse as a consequence of the solar radiation decrease. A large temperature drop exceeding $4^{\circ}C$ was observed at most area (8 sites) of the BMR. Significant ozone drop (18~29 ppb) was also observed during the eclipse mainly due to the decreased efficiency of the photochemical ozone formation. The ozone concentration started to decrease at approximately 1 to 2 hours after the event and reached its minimum value for a half hour to 2 hours after maximum eclipse. The rate of ozone fall ranged between 0.18 and 0.49 ppb/min. The comparison between ozone measurements and the expected values derived from the fitted curve analysis showed that the maximum drop in ozone concentrations occurred at noon or 1 PM and was pronounced at industrial areas.

Characteristics of Condensing Heat Transfer and Pressure Drop of HCs Refrigerants (탄화수소계 냉매의 응축 열전달 및 압력강하 특성)

  • Lee, Ho-Saeng;Lee, Kwang-Bae;Moon, Choon-Geun;Kim, Jae-Dol;Yoon, Jung-In
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1143-1148
    • /
    • 2005
  • Experimental results for heat transfer characteristic and pressure gradient of HCs refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 during condensing inside horizontal double pipe heat exchangers are presented. The test sections which have one tube diameter of 12.70 mm with 0.86 mm wall thickness, another tube diameter of 9.52 mm with 0.76 mm wall thickness are used for this investigation. The local condensing heat transfer coefficients of hydrocarbon refrigerants were higher than those of R-22. The average condensing heat transfer coefficient increased with the increase of the mass flux. It showed the higher values in hydrocarbon refrigerants than R-22. Hydrocarbon refrigerants have higher pressure drop than those of R-22 in 12.7 mm and 9.52 mm. This results from the investigation can be used in the design of heat transfer exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.

  • PDF

Prediction of Reaeration Coefficients in Rural Small Streams (농촌 소하천에서의 재폭기 계수 추정)

  • 송인홍;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.5
    • /
    • pp.163-171
    • /
    • 2001
  • Reaeration phenomena, the physical process of absorption of oxygen from atmosphere, is one of the important parameters of dissolved oxygen simulation in streams. This study was aimed at predicting reaeration coefficients in rural small streams, examining the influence of drop structure on reaeration and the seasonal fluctuation of reaeration coefficients. Reaeration coefficients of five streams including four tributaries of Bokha watershed in Gyeonggi Ichon and Onyang stream in Chungnam Onyang were measured. Constant rate injection (CRI) method using propane and Rhodamine-WT as gas and dye tracer was adopted. Reaeration coefficients ranged between 6.16 and 29.16 reciprocal day, higher than those in USGS database. Prediction equation,$k_2=CV^{0.593}$, was regressed from the measured data at 95% confidence level, with an absolute error of 21.2% and a standard error of 4.0 reciprocal days. Reaeration coefficients of experimental reaches with drop structure showed percentile increases of 42.3 to 159.2 compared to those without it, an indication that drop structure plays an important role on stream reaeration. Taking into consideration the seasonal fluctuation of reaeration coefficients, the values measured during September and October were the highest, mainly due to the removal of aquatic plants. by intensive rainfall during summer.

  • PDF

Characteristics of Condensing Heat Transfer and Pressure Drop of Hydrocarbon Refrigerants (탄화수소계 냉매의 응축 열전달 및 압력강하 특성)

  • Lee Ho-Saeng;Seong Gwang-Hoon;Tong Phan Thanh;Yoon Jung-In
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.977-983
    • /
    • 2006
  • Experimental results for heat transfer characteristic and pressure gradient of hydrocarbon refrigerants (R-290, R-600a, R-1270) and HCFC refrigerant (R-22) during condensation inside horizontal double pipe heat exchangers are presented. The test sections which have one tube diameter of 12.70 mm with 0.89 mm, 9.52 mm with 0.76 mm, 6.35 mm with 0.13 mm wall thickness are used for this investigation, respectively. The local condensing heat transfer coefficients of hydrocarbon refrigerants were higher than those of R-22. The average condensing heat transfer coefficient increased with the increase of the mass flux. It showed the higher values in hydrocarbon refrigerants than R-22. Hydrocarbon refrigerants have higher pressure drop than R-22 in 10.92 mm, 8 mm and 6.1 mm inner diameters. These results from the investigation can be used in the design of heat transfer exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.