• Title/Summary/Keyword: drop values

Search Result 388, Processing Time 0.022 seconds

Prediction and Experiment of Pressure Drop of R22, R407C and R410A on Design Conditions of Condenser (응축기의 설계조건에서 R22, R407C, R410A의 압력강하 예측 및 실험)

  • 김창덕;박일환;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.42-53
    • /
    • 2004
  • An experimental study on the refrigerant-side pressure drop of slit fin-tube heat exchanger has been carried out. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the pressure drop on design conditions of condenser in micro-fin tube for R22 and its alternatives, R407C (R32/125/134a, 23/25/52 wt.%) and R410A (R32/125, 50/50 wt.%). Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and mass fluxes varying from 150 to 250 kg/$m^2$s for R22, R407C and R410A. The inlet air conditions are dry bulb temperature of 35$^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.43 m/s. Experiments show that pressure drop for R410A and R407C were 17.8∼20.2% and 5∼6.8% lower than those of R22 respectively for the degree of subcooling of 5$^{\circ}C$. For the mass fluxes of 200∼250 kg/$m^2$s, the deviation between the experimental and predicted values for the pressure drop was less than $\pm$20% for R22, R407C and R410A.

Evaluation of Changesin the Physical Characteristics of Raindrops Under a Canopy in Central Korea (나무 아래 빗방울(雨滴)의 물리적 특성변화 분석)

  • Kim, Jin Kwan;Kim, Min Seok;Yang, Dong Yoon;Lim, Young Shin
    • Journal of The Geomorphological Association of Korea
    • /
    • v.23 no.3
    • /
    • pp.105-122
    • /
    • 2016
  • To evaluate the changes in the physical characteristics of open rainfall related to canopy effects and rainfall intensity in Korea, the terminal velocity of raindrops and drop size distributions(DSD) were continuously measured by an optical-laser disdrometer in an open site(Op) and in two forest stands(Th1: Larix leptolepis, Th2: Pinus koraiensis) during five rainfall events in 2008. The terminal velocity, DSD and two forms of kinetic energy(KE, $Jm^{-2}$ $mm^{-1}$; KER, $Jm^{-2}$ $h^{-1}$) of open rainfall drops were determined and were compared with those of throughfall drops under two different canopy heights. The effects of the canopy and rainfall intensity, together with wind speed, on the changes in drop size and kinetic energy of throughfall were evaluated. Throughfall drops were larger than open rainfall drops. The distribution of terminal velocities for the drop sizes measured at Th2 was lower than that at Op; however, at Th1 the distribution was similar to that at Op. The total kinetic energy of throughfall at Th1 and Th2 was higher than the total kinetic energy of open rainfall, and the kinetic energy distribution for the drop sizes wassimilar to the drop size distribution. The observed throughfall-KER at Th1 was lower than an estimate previously produced using a model. The overestimation from the modeled value at Th1 was likely to be due to overestimated values of a square root transformation of fall height and its coefficient in the model because the distributions of terminal velocity for the drop size measured at Th1 were similar to those of open rainfall.

Stress relaxation effect on uniaxial compressive strength values of a silt type soil

  • Eren Komurlu
    • Geomechanics and Engineering
    • /
    • v.32 no.5
    • /
    • pp.495-502
    • /
    • 2023
  • In this study, stress relaxation tests were carried out by keeping silt type soil specimens under different strain levels. Decreases in the stress values with time data was collected to better understand the effect of the strain level on the relaxation properties of soil specimens. In addition, the stress relaxation effect on the uniaxial compressive strength (UCS) values of the specimens was investigated with a series of tests. According to the results obtained from this study, the UCS values of the silt specimens significantly vary as a result of the stress relaxation effect. The UCS values were determined to increase with an increase of relaxation strain level to a threshold value. On the other hand, the UCS values were found to be affected adversely in case of high stress levels at the initiation of the relaxation, which are close to the peak level.

An Experimental Study on Heat Transfer and Pressure Drop Characteristics of Carbon Dioxide During Gas Cooling Process in a Hellically Coiled Tube

  • Oh, Hoo-Kyu;Son, Chang-Hyo;Yu, Tae-Geun;Kim, Dae-Hui
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.263-271
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during 9as cooling process of $CO_2$ (R744) in a helically coiled copper tube with the inner diameter of 4.55 mm and outer diameter of 6.35 mm were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter a pre-heater and a helically coiled type gas cooler (test section). The refrigerant mass fluxes are varied from 200 to $800kg/m^2s$ and the inlet pressures of gas cooler are 7.5 to 10.0 MPa. The heat transfer coefficients of $CO_2$ in a helically coiled tube are higher than those in a horizontal tube. The Pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those predicted by Ito's correlation developed for single-phase in a helically coiled tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However. at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al correlation. Therefore, various experiments in helically coiled tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in a helically coiled tube.

Belt Pattern Making for Hip-hugger garment using 3D Body Scan Data (3차원 인체 스캔 데이터를 활용한 Hip-hugger 의류용 벨트 패턴 설계)

  • Park, Soon-Jee;Choi, Sin-Ae
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.652-659
    • /
    • 2008
  • This study was designed to testify the possibility and devise the method to manipulate the 3D body scan data to produce rounded-belt pattern adaptable to hip-type variation of women in their 20's. The results of this research were as follows : Firstly, based on drop-value distribution of hip and waist girth, 151 subjects were classified into three hip-types; Type 1 (15.23%) was 'cylinder type', showing lowest drop-value, Type 2 (69.54%) was 'average type' and Type3 (15.23%) was 'hourglass type' showing highest drop-value. Secondly, using CAD program, design lines for round shape belt were set on the surface of 3D scan data of representative subject of each type. And divided 3D surfaces were flattened onto the plane by the internal tools of CAD program. The measure, 'lifting value of round belt pattern', implying the level of curve ratio of pattern was higher in back than front. This result might be linked to the fact that the hip part is more protruded than the abdomen part. And the measures also showed highest values in Type 3(hourglass type) and lowest in Type 1(cylinder type), meaning that the pattern of Type 3 showed more rounded shape than that of Type 1. This finding implied that round belt for body type having high drop-value should be shaped more curved. Thirdly, difference ratios of outline length and area between 3D curves(body surface) and 2D plane(pattern) were 4.5% and 1.3%, respectively. This result demonstrated and solidified the feasibility of designing digital garment pattern from 3D body scan data.

Development of A Computer Program for Drop Time and Impact Velocity of the Rod Cluster Control Assembly (제어봉집합체의 낙하시간과 충격속도 계산을 위한 프로그램 개발)

  • Park, Ki-Seong;Kim, Il-Kon
    • Nuclear Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.197-204
    • /
    • 1994
  • In a PWR rod cluster control assembly(RCCA) for shutdown is released upon action of control rod drive mechanism and falls down through the guide thimble by its weight. Drop time and impact velocity of the RCCA are two key parameters with respect to reactivity insertion time and the mechanical integrity of fuel assembly. Therefore, the precise control of drop time and impact velocity is prerequisite to modifying the existing design features of the RCCA and guide thimble or newly designing them. During its falling down into the core, the RCCA is retarded by various forces acting on it such as fluid resistance caused by the RCCA movement, buoyance and mechanical friction caused by contacting inner surface of the guide thimble, etc. However, complicated coupling of the various forces makes it difficult to derive an analytical dynamic equation for the drop time and impact velocity. This paper deals with the development of a computer program containing an analytical dynamic equation applicable to the Korean Fuel Assembly(KOFA). The computer program is benchmarked with an available single control rod drop tests. Since the predicted values are in good agreement with the test results, the computer program developed in this paper can be employed to modify the exiting design features of the RCCA and guide thimble and to develope their new design features for advanced nuclear reactors.

  • PDF

Biomechanical Effects of Wearing Mouthguards during Drop Landing (드롭 착지동작 시 마우스가드 착용이 운동역학적 변인에 미치는 영향)

  • Chae, Woen-Sik;Lee, Kyu-Bok;Jung, Jae-Kwang;Lee, Haeng-Seob;Kim, Dong-Soo;Jung, Jae-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.4
    • /
    • pp.347-355
    • /
    • 2013
  • The purpose of this study was to determine the biomechanical effect of wearing the mouthguard on the lower limb during drop landing. Nine male university students who have no musculoskeletal disorder were recruited as the subjects. Linear velocity, angular velocity, vertical GRF, loading rate, joint moment, and lower extremity muscle activity were determined for each subject. For each dependent variable, paired t-test was performed to test if significant difference existed between with mouthguard (WM) and without mouthguard (WOM) conditions (p<.05). The results showed that linear velocity, angular velocity, vertical GRF and loading rate were no significant difference between the two groups. The inversion moment of the ankle joint was increased in WM compared to WOM. Average IEMG values from BF, TA, and LG in WM were significantly greater than corresponding values in WOM during IP phase. This indicates that wearing mouthguard played a vital role in muscle tuning for maintaining joint stability of the lower limb and preventing injury.

Assessment of Coal Combustion Safety of DTF using Response Surface Method (반응표면법을 이용한 DTF의 석탄 연소 안전성 평가)

  • Lee, Eui Ju
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.8-13
    • /
    • 2015
  • The experimental design methodology was applied in the drop tube furnace (DTF) to predict the various combustion properties according to the operating conditions and to assess the coal plant safety. Response surface method (RSM) was introduced as a design of experiment, and the database for RSM was set with the numerical simulation of DTF. The dependent variables such as burnout ratios (BOR) of coal and $CO/CO_2$ ratios were mathematically described as a function of three independent variables (coal particle size, carrier gas flow rate, wall temperature) being modeled by the use of the central composite design (CCD), and evaluated using a second-order polynomial multiple regression model. The prediction of BOR showed a high coefficient of determination (R2) value, thus ensuring a satisfactory adjustment of the second-order polynomial multiple regression model with the simulation data. However, $CO/CO_2$ ratio had a big difference between calculated values and predicted values using conventional RSM, which might be mainly due to the dependent variable increses or decrease very steeply, and hence the second order polynomial cannot follow the rates. To relax the increasing rate of dependent variable, $CO/CO_2$ ratio was taken as common logarithms and worked again with RSM. The application of logarithms in the transformation of dependent variables showed that the accuracy was highly enhanced and predicted the simulation data well.

Chaoticity Evaluation of Ultrasonic Signals in Welding Defects by 6dB Drop Method (6dB Drop법에 의한 용접 결함 초음파 신호의 카오스성 평가)

  • Yi, Won;Yun, In-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.7 s.166
    • /
    • pp.1065-1074
    • /
    • 1999
  • This study proposes the analysis and evaluation method of time series ultrasonic signal using the chaotic feature extraction for ultrasonic pattern recognition. Features extracted from time series data using the chaotic time series signal analysis quantitatively welding defects. For this purpose analysis objective in this study is fractal dimension and Lyapunov exponent. Trajectory changes in the strange attractor indicated that even same type of defects carried substantial difference in chaoticity resulting from distance shills such as 0.5 and 1.0 skip distance. Such differences in chaoticity enables the evaluation of unique features of defects in the weld zone. In experiment fractal(correlation) dimension and Lyapunov exponent extracted from 6dB ultrasonic defect signals of weld zone showed chaoticity. In quantitative chaotic feature extraction, feature values(mean values) of 4.2690 and 0.0907 in the case of porosity and 4.2432 and 0.0888 in the case of incomplete penetration were proposed on the basis of fractal dimension and Lyapunov exponent. Proposed chaotic feature extraction in this study enhances ultrasonic pattern recognition results from defect signals of weld zone such as vertical hole.

Classification of Size Specifications for the Ready-made Jacket-from 28 years to 35 on the Korean adult male- (신사복 상의제작을 위한 사이즈스팩의 분류-28세에서 35세 우리나라 남성을 대상으로-)

  • 김구자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.8
    • /
    • pp.1090-1098
    • /
    • 1998
  • The purpose of this study was to classify size specifications of the Korean adult male for the men's ready-made garments, especially jacket and dress shirts. By the stratified sampling method, data were collected by the real anthropometric measurement and by the photo-graphic sources. Sample size was 532 subjects as the sample and their age range was from 28 to 35 years old. 66 variables from the direct anthropometric data in total were applied to analyze. ANOVA in SPSS WIN package was applied to the data and the expected frequency distribution of 10.000 men was calculated by the extraction of density function. This study was performed to classify size specifications by the control dimensions and at the same interval of KS-K. The drop values of 15, 12 and 9 have the high coverage rate of 26.00%, 24.29% and 21.06% respectively and are composed of the majority of 71.35% of the subjects. According to the drop values, size specifications and distribution of control and reference dimensions are predicted. About 52.12% of the expected frequency distribution without stature were covered by 12 size specifications.

  • PDF