• Title/Summary/Keyword: drop system

Search Result 1,904, Processing Time 0.029 seconds

Heat Transfer and Pressure Drop Characteristics of Secondary Refrigerants Applying to Indirect Refrigeration System (간접 냉동 시스템용 2차 냉매의 열전달과 압력강하 특성)

  • Oh, Hoo-Kyu;Son, Chang-Hyo;Jo, Hwan;Yi, Wen-Bin;Jeon, Min-Ju
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.45-50
    • /
    • 2013
  • This paper presents the comparison of heat transfer and pressure drop of various secondary refrigerants (single-phase and two-phase) in the indirect refrigeration system. The main results were summarized as follows: In case of heat transfer, it is useful to use secondary refrigerants in low evaporating temperature region and the heat transfer coefficient of single-phase is larger than two-phase secondary refrigerants. In case of pressure drop, it is useful to use secondary refrigerants in high evaporating temperature region and the pressure drop of two-phase is smaller than single-phase secondary refrigerant. Also, $CO_2$ is the best useful because pressure drop of $CO_2$ among the secondary refrigerants is the smallest.

A Study on the Adoption of Self Bag-Drop System to Enhance Airport Operation (공항운영 향상을 위한 Self Bag-Drop System(무인수하물처리시스템) 적용가능성 연구)

  • Lee, Kang-Seok;Ji, Min-Seok
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.23 no.2
    • /
    • pp.75-83
    • /
    • 2015
  • Advanced countries in the aviation industry, especially the United States and European Union, develop and commercialize their own SBD system integrated with IT convergence technology, dominating the international market. Nevertheless, most of SBD technologies in domestic airports rely on other countries. It is imperative that internal airport operators introduce the Self Bag Drop system and produce, apply, and manage the most optimized SBD system for airports and airlines. Upon analyzing the tendency and operation of the SBD system utilized in leading international airports, this is conducted to address the possibility of the future implementation in domestic airports.

Development and Application of Drop Impact Tester for Aerospace Structures (항공우주구조물 낙하충격시험기 개발 및 응용)

  • Yesol Shin;Hyejin Kim;Juho Lee
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.3
    • /
    • pp.56-64
    • /
    • 2024
  • In this study, a drop impact tester was developed to comprehensively conduct basic testing and academic research on the drop impact characteristics of aerospace structures. A drop tester enables accurate assessment of the dynamic stresses and deformations that occur when an aircraft collides with the ground, thereby enabling the verification of important design factors, such as safety and mechanical strength. The drop tester consists of an electromagnet to attach and drop the test object, a crane to adjust the drop height of the test object, and a drop support structure for vertical drops. Numerical analysis of the drop test object for the test was performed, and basic tests were performed using the drop impact tester. Through the analysis and test results, the structural shape of the landing gear was analyzed, and the behavior of each part was evaluated.

Analysis of Voltage Drop under Extended Feeding in KyungBu High Speed Line (I) (경부고속선의 전력공급 안정성 검토를 위한 연장급전 조건의 전압강하 검토 (I))

  • Kim, Joo-Rak;Lee, Chang-Mu;Jang, Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1432-1438
    • /
    • 2011
  • This paper presents the simulation of traction power supply system for the evaluation of voltage drop in Kyungbu high speed line. This simulation is performed in circumstance of extended feeding through vicinity substation. Extended feeding should be considered from design of system. Therefore, voltage drop at extended feeding must be accepted against regulation. In this paper, voltage drop is evaluated under condition of extended feeding targeting section from Shinchungju and Pyungtaek S/S.

  • PDF

In Vitro Development of Porcine Parthenogenetic Embryos under the Oil-free Culture System

  • Park, Sang-Kyu;Choi, Young-Ju;Roh, Sang-Ho
    • Journal of Embryo Transfer
    • /
    • v.25 no.4
    • /
    • pp.259-262
    • /
    • 2010
  • Optimization of the preimplantation mammalian embryo culture condition was widely focused on refining medium composition under the name of chemically defined media. However, recent research revealed that the alteration of physical environment can be a crucial factor to a successful embryo development. In this study, under the same embryo density, a novel culture device named oil-free micro tube culture (MTC) system was evaluated using porcine parthenogenetic embryos. The activated oocytes were placed into the 0.2 ml thin-wall flat cap PCR tube and cultured to the blastocyst stage. As a preliminary step, embryo density and culture medium volume were optimized under a standard drop culture system. The optimal embryo density range for in vitro culture was 0.5 embryos per ${\mu}l$ in $20\;{\mu}l$ drop (20.5%) and 1.0 embryos per ${\mu}l$ in $10\;{\mu}l$ drop (20.6%). Based on these results, we compared drop culture system and 'MTC' system in terms of the developmental rate to the blastocyst stage. In $20\;{\mu}l$ medium volume, the 'MTC' system showed similar blastocyst formation rate when compared with drop culture system (20.2% versus 20.5%, respectively) while the 'MTC' system showed lower blastocyst formation rate than drop culture system in $10\;{\mu}l$ one (12.7% versus 20.0%, respectively). Therefore the $20\;{\mu}l$ MTC system may be an alternative incubation system for short-distance embryo transport without carrying the $CO_2$ incubator and this provides novel embryo culture device to clinical veterinary embryologists.

A Study on Voltage Drop Compensation by STATCOM Considering Dynamic Characteristics of the 3-Phase Induction Motor in Electric Railway Systems (전기철도 3상유도전동기의 기동특성을 고려한 STATCOM에 의한 전압강하 보상에 관한연구)

  • Hwang, Sung-Ho;Oh, Min-Hyuk;Lee, Byung-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.337-339
    • /
    • 2005
  • The purpose of this paper is to compensate the voltage drop of the power system in the AC High-Speed Railway (HSR). Reactive power compensation is often the most effective way to improve system voltage drop. The suitable modeling of the electric railway system should be applied to the EMTP. the dynamic characteristics of 3-Phase Induction Motor in Electric Railway Systems is considered for precise modeling. it is shown through EMTP simulation that voltage drop can be compensated effectively by STATCOM.

  • PDF

The Effect of Air Vent Holes and Stacking Methods of Fruits and Vegetables Boxes on Static Pressure Drop in Pressure Cooling System (청과물상자의 통기공 및 상자적재방법이 정압강하에 미치는 영향)

  • 김의웅;김병삼;남궁배;정진웅;김동철;금동혁
    • Journal of Biosystems Engineering
    • /
    • v.20 no.4
    • /
    • pp.360-367
    • /
    • 1995
  • The effect of air vent holes, stacking methods of boxes and clearance between boxes on static pressure drop, were measured to design of pressure cooling system. Static pressure drops in air vent hole of carton box were measured for different hole opening ratio from 1% to 5%. Static pressure drop was expressed as a function of superficial velocity as second-degree polynomial. At given static pressure in plenum chamber, static pressure drop in boxes was shown as second-degree polynomial of the number of carton box in series stacking method, as first-degree polynomial in height and parallel stacking method. In pressure cooling of 24 boxes of Tsugaru apple, air flow rates through clearance between the boxes were shown 1.27 and 1.65 times than those of through the inside of boxes at the plenum pressure of 10mmAq and 20mmAq, respectively.

  • PDF

Design and Analysis of Instantaneous Voltage Drop Compensator (순간전압강하 보상기의 설계와 해석)

  • Lee, Taeck-Kie;Hyun, Dong-Seok;Hwang, Yong-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.478-481
    • /
    • 1991
  • This paper discusses the principle and structure of instantaneous voltage drop compensator, which protects damage from instantaneous voltage drop in systems such as computer, variable speed drive, high voltage discharge-lamp, magnet switch. When instantaneous voltage drop occurs, control circuits detect it, then produce output voltage the same as normal condition voltage. Instantaneous voltage drop compensator has condenser bank as energy storage component, so system can be made small, light weight compared with UPS. In normal state, utility source transfers power, and in instantaneous voltage drop state, the energy of condenser bank transfers power through inverter, so high efficiency, compact, and especially low cost system can be manufactured.

  • PDF

Analysis of Metal Transfer using Dynamic Force Balance Model in GMAW (동적 힘 평형 모델을 이용한 GMA 용접의 용적이행 해석)

  • 최재형;이지혜;유중돈
    • Journal of Welding and Joining
    • /
    • v.19 no.4
    • /
    • pp.399-405
    • /
    • 2001
  • A dynamic force balance model is proposed in this work as an extension of the previous static force balance model to predict metal transfer in arc welding. Dynamics of a pendant drop is modeled as the second order system, which consists of the mass, spring and damper. The spring constant of a spherical drop at equilibrium is derived in the closed-form equation, and the inertia force caused by drop vibration is included in the drop detaching condition. While the inertia force is small in the low current range, it becomes larger than the gravitational force with current increase. The inertia force reaches half of the electromagnetic force at transition current, and has considerable effects on drop detachment. The proposed dynamic force balance model predicts the detaching drop size more accurately than the static force balance model.

  • PDF