• 제목/요약/키워드: drop rate

검색결과 1,337건 처리시간 0.024초

고점도 도료의 압력손실 및 분사량에 관한 연구 (A Study on Pressure Drop and Flow Rate of High Viscosity Paint)

  • 백재진;정몽규;신칠석;백광기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.786-791
    • /
    • 2003
  • We have studied on the main causes of pressure drop in the paint hose under the spraying with airless spray pump and suggest calculation method for selecting the optimum pressure drop during the spraying. Among many factors contributing the pressure drop during the airless spraying procedure of paint, some of the key factors and the correct method for checking pressure loss between airless pump and spray gun are addressed. We have developed pressure loss calculation method which depending on hose length and diameter, viscosity and flow rate in the painting hose during the spraying. also we have developed calculation equation for the expected spray tip flow rate which depending on pressure and specific gravity and tip size.

  • PDF

OBS망에서의 TCP 재전송을 고려한 Drop Policy의 성능 향상 (Performance Improvement of the Drop Policy based on TCP Retransmission in Optical Burst Switched Networks)

  • 김래영;김현숙;김효진;송주석
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2003년도 가을 학술발표논문집 Vol.30 No.2 (3)
    • /
    • pp.1-3
    • /
    • 2003
  • OBS망에서 버스트의 충돌로 인한 버스트의 drop은 TCP의 성능에 중요한 영향을 끼치나, 기존의 drop policy에서는 이를 고려하지 않으며 TCP에 대한 연구로는 버스트의 assembling이 주를 이루고 있다. 본 논문에서는 OBS망에서 TCP의 재전송 문제를 drop policy와 연계하여 그 성능을 향상시키고자 한다. 본 논문에서 제안하는 drop policy는 버스트의 재전송 횟수가 더 작은 버스트를 drop시키는 TCP 기반 DP이다. TCP 기반 DP 모델과 일반적인 DP 모델의 성능을 ns­2를 이용한 시뮬레이션을 통해 평가하며, 이 때 시간의 변화에 따른 TCP throughput과 패킷의 drop rate을 비교 분석한다.

  • PDF

초미세 발포 사출 시 핵 생성장치를 이용한 셀 크기의 변화 (Cell morphology of microcellular foaming injection molding products with pressure drop rate)

  • 김학빈;차성운
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.491-495
    • /
    • 2004
  • The industries use polymer materials for many purposes for they have many merits. The costs of these materials take up too great a proportion of the overall cost of products that use these materials as their major material. It is advantage for polymer industries to reduce these costs. The microcellular foaming process was developed in the early 1980s to solve this problem and proved to be quite successful. Microcellular foaming process uses inert gases such as $CO_2$, $N_2$. As these gases solve into polymer matrices, many properties are changed. The microcellular foaming process makes the glass transition temperature of polymers to low, and diminish the residual stress of polymer matrices. Besides, the microcellular foaming process has several merits, impact strength elevation, thermal insulation, noise insulation, and raw material saving etc. This characteristic of microcellular foaming process has influenced by cell morphology. The cell morphology means cell size and cell density. The cell morphology has influenced by many factors. The examples of factor are pressure drop rate, foaming temperature, foaming time, saturation pressure, saturation time etc. Among their factors, pressure drop rate is the most important factor for cell morphology in microcellular foaming injection molding process. This paper describes about the cell morphology change in accordance with the pressure drop rate of microcellular foaming injection molding process.

  • PDF

자동차용 에어컨의 고밀도 응축기(SCC)에서 배플의 위치 변화에 따른 성능향상에 관한 연구 (Effects of Baffle Location on the Performance of a Super Compact Condenser in an Automotive Air Conditioning System)

  • 이명재;박복춘;백병준;염동석;한창섭
    • 한국자동차공학회논문집
    • /
    • 제5권6호
    • /
    • pp.128-140
    • /
    • 1997
  • A new super compact condenser(SCC), which has been developed recently is especially suitable for an alternative refrigerant HFC-134a due to its high performance and compactness. The SCC is composed of two pipe headers, baffles, narrow multi-rectangular channels, and louvered fin arrays. Alternating inlet and outlet by the inserted baffles in pipe headers guide refrigerant to and from the narrow multi-rectangular channels. Since the flow rate and its lengh are changed depending on the number and location of baffles, the corresponding pressure drop and heat transfer rate are changed. The present study aims to theoretically and experimentally investigate the effects of baffle location and its number on the pressure drop and thermal performance of the SCC with 40 multi-rectangular channels. The results show that the present method provides an acceptable prediction of pressure drop and heat transfer rate for a 4 pass SCC. However, the model significantly under predicts the performance of a 3 pass SCC, which may be attributed to the phase separation of refrigerant flowing through header pipes. Pressure drop is more signifi- cantly influenced than heat transfer rate by the baffle location.

  • PDF

PGSFR 제어봉집합체 낙하성능시험 (Drop Performance Test of Control Rod Assembly for Prototype Gen-IV Sodium-cooled Fast Reactor)

  • 이영규;김회웅;이재한;구경회;김종범;김성균
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.134-140
    • /
    • 2016
  • The Control Rod Assembly (CRA) controls the reactor power by adjusting its position in the reactor core during normal operation and should be quickly inserted into the reactor core by free drop under scram condition to shut down chain reactions. Therefore, the drop time of the CRA is one of important factors for the safety of the nuclear reactor and must be experimentally verified. This study presents the drop performance test of the CRA which has been conceptually designed for the Proto-type Generation IV Sodium-cooled Fast Reactor. During the test, the CRA was free dropped from a height of 1 m under different flow rate conditions and its drop time was measured. The results showed that the drop time of the CRA increased as the flow rate increased; the average drop times of the CRA were approximately 1.527 seconds, 1.599 seconds and 1.676 seconds at 0%, 100% and 200% of design flow rates, respectively.

노년남성의 체형분류에 관한 연구 (A Study on the Classification of Elderly Male's Body Type)

  • 김수현;이정란
    • 한국의류학회지
    • /
    • 제27권6호
    • /
    • pp.624-634
    • /
    • 2003
  • The purpose of this study was to classify body types of elderly male aged between 60 and 80. 40 direct items and 22 indexes were measured. The result were as follows. First. through the factor analysis of indexes, 8 factors were extracted upon factor scores, 4 clusters represented characteristics of elderly male's body type. Type 1 indicates flat and bend-forward type. Type 2 indicates fat and bend-forward type. Type 3 indicates lean-back type and is a little bit fat and the waist is round. Type 4 indicates a straight type in which the chest and the hip are developed. Second, drop was needed to discriminate elderly male's body type. 3 types of drop were extracted. The body type with big drop is Y type in which the drop distance is between 14 and 22cm. The body type with standard drop is A type in which the drop distance is between 6 and 14cm. The body type with small drop is B type in which the drop distance is between -4 and 6cm. Third, when the types of appearance rate were combined, 7 body types of elderly male showed high appearance rate; A1, B1, A2, B2, A3, A4, B4. According to the above result, flat and bended-forward type with drop A was dominant body type of elderly male.

D2EHPA에 의한 수용액속의 아연 추출에 관한 연구 (A study on Extraction of Zinc in the Aqueous Water by D2EHPA)

  • 이수경
    • 한국안전학회지
    • /
    • 제2권1호
    • /
    • pp.17-29
    • /
    • 1987
  • The extraction mechanism of Zinc from aqueous solution with D2EHPA (Di-2-Ethylhexyl Phosphoric Acid) dissolved in Kerosene was studied by the single drop method. The effect of the concentrations of reactant species on the extraction rate, Zinc and hydrogen ion in the continuous phase and D2EHPA in the dispersed, was studied for the drop rise period by the experiment. Then a theoretical analysis on the basis of Handlos-Baron modle was carried out. It becomes clear that the extraction rate was controlled by the neutral complex forming reaction at the drop surface from both analysises. From effect of the concentrations of species on the reaction rate, the extraction rate at the drop surface is considered to be as follows. $${\gamma}_{pn}=9.42{\times}10^{-7}\;\frac{[Zn^{2+}][(HR)_2]^{3/2}}{[H^+]^{3/2}}$$

  • PDF

용접식 판형열교환기에서 작동유체의 유량과 온도변화에 따른 성능특성 고찰 (Investigation of Performance Characteristics in a Welded Plate Heat Exchanger according to Mass flow rate and Temperature)

  • 함정균;김민준;안성국;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.20-26
    • /
    • 2018
  • In this study, the performance characteristics of a welded plate heat exchanger was investigated experimentally. Performance tests were carried out according to the flow rate and inlet temperature of working fluid. As a result, the heat transfer capacity increased by 335.5 kW with an increasing the flow rate and temperature difference between hot and cold side. However, the overall heat transfer coefficient was increased with the increase of flow rate, and it was not effected significantly from inlet temperature difference between hot and cold working fluid. The pressure drop was increased by 55.78 kPa with an increasing the frow rate when the flow rate ratio between hot and cold side 1:1. However, the tendency of pressure drop was difference when flow rate ratio wasn't 1:1. In case that the flow rate ratio between hot and cold side was not 1:1, the pressure drop at the low flow rate side was higher than that when the flow rate ratio was 1:1, while pressure drop of the other side was decreased compared to that when the flow rate ratio was 1:1.

Research on the Power Drop of Photovoltaic Module’s Aging Through the Thermal Shock Test

  • Kang, MinSoo;Jeon, YuJae;Kim, DoSeok;Shin, YoungEui
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권5호
    • /
    • pp.268-273
    • /
    • 2015
  • While analyzing the specimens before and after the thermal shock test, we found that the power drop rate of the bare cell was 5.08%, while the power drop rate of the ribboned cell was 16.49%. In comparative terms, the efficiency was lower at the ribboned cell than at the bare cell. While analyzing through EL (Electroluminescence) shots and cross sections, we tried to decipher the exact cause of the power drop. Although mere color change of the cell was observed at the surface of the bare cell, no abnormality could be found inside the cell. On the surface of the ribboned cell, the short circuit of gridfinger extended from the front part of the front electrode of the ribboned cells. Therefore, cracks occurred on the surface of the cell. Cracks also appeared inside the cell. While analyzing the I-V curve, we determined an increase in the leakage current and an increase of resistances in series in the bare cell. In the ribboned cell, the resistances in parallel reduced remarkably. An increase of resistances in series could also be verified. Conclusively, we deduced that the power drop rate in the bare cell is a life span of the cell itself; aging is the cause of power drop rate in cells. In case of ribboned cell, the power drop rate was directly influenced by internal cracks and an intermetallic compound layer joining the ribbon at the front electrode.

냉매 R-22, R-407C의 수평평활관내 응축압력강하에 관한 연구 (Pressure drop of R-22 and R-407C during condensation in horizontal smooth tubes)

  • 노건상;오후규;권옥배
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권4호
    • /
    • pp.70-80
    • /
    • 1996
  • Experimental results for forced convection condensation of R-22 and R-407C inside 7.5mm ID and 4000mm length of horizontal tubes are presented. The experimental data covered total flow rate from 114.3 to 267.1kg/($m^2$.s) and quality from 0 to 1. The vapor temperature and pressure drop along the tube were measured. The pressure drop for R-407C increased with flow rate similar to that of R-22. The experimental data compared with the available perdictions for pressure drop. Based on the data a prediction method was presented for the calculation of pressure drop of R-22 alternative refrigerants.

  • PDF