• Title/Summary/Keyword: drawer

Search Result 99, Processing Time 0.03 seconds

A Study on the Patterns of Men's Drawers Panties (남성 드로즈(drawers) 팬티의 패턴 분석)

  • Lee, Jung-Jin;Lee, Jung-Soon
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.18 no.1
    • /
    • pp.169-181
    • /
    • 2016
  • This study analyzed the characteristics and patterns of men's drawers panties to get basic data for their design. For this, drawers panties in 7 different brands (4: domestic brands, 3: imported brands) in terms of a front-center shape were collected, and the shape of men's drawers panties, characteristics of the materials, dimensions & type of patterns by the part and front-center patterns were analyzed. The study results found the followings: First, in terms of the shape of men's drawers panties, the front-center part were designed to rest the penis and scrotum in a natural and comfortable manner without a pee slit. They were seamless on the sides except for one product with side seams. Second, the drawer panties were made of elastic polyurethane materials. Specifically, domestic brand items used warm, elastic and durable nylon, polyester and rayon and polyurethanes while imported brands were mostly made of absorbent and sanitary polyurethanes. Third, regarding a size of drawer panties by part, imported brands were large in waist circumference. In terms of waist breadth at the front center, there was difference depending on an oval type. In addition, the front length at the front center differed by product, revealing difference in three-dimensional effect at the front center. The side length also differed greatly by product, which means that there might be a great difference in wear comfort. Fourth, in terms of the patterns of men's drawers panties, there was difference in side seams, center back seam and front-center patterns. Among a total of 7 products, only one product had side seams, and center back seams were found in two products only. Fifth, in terms of front-center patterns, the drawer panties can be divided into three types, creating three-dimensional effect not to give any pressure on the crotch: i) the cutting line only at the bottom of the front center part where the penis is rested, ii) puff created at the front center by adding a transverse line to the center line, iii) cutting transverse line to separate the penis from the testicles.

  • PDF

Stress Radiographs under Anesthesia for Painful Chronic Lateral Ankle Instability (동통을 동반한 족관절의 만성 외측 불안정성에 있어서 마취하 스트레스 방사선 검사)

  • Choi, Jun Young;Ahn, Hee Chan;Shin, Myung Jin;Suh, Jin Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.1
    • /
    • pp.12-16
    • /
    • 2017
  • Purpose: Anterior drawer and varus stress radiographs are commonly to diagnose chronic lateral ankle instability. We compared the preoperative stress radiographs with the intraoperative radiographs under anesthesia to determine the accuracy and efficacy of stress radiographs in an outpatient clinical environment. Materials and Methods: Data was collected from patients who underwent a modified $Brostr{\ddot{o}}m$ operation for painful chronic unilateral lateral ankle instability between January 2014 and June 2016. Subjects were divided into three groups-complete tear, partial tear, and instability without rupture-according to the status of preoperative MRI findings of the anterior talofibular ligament. The anterior drawer and varus stress radiographs were taken preoperatively and intraoperatively under anesthesia. Results: Ninety-six patients, with a mean age of 29.63 years, were enrolled. There were 39, 46, and 11 patients in the complete tear, partial tear, and instability without rupture groups, respectively. On the anterior drawer and varus stress radiographs of the affected limb, talar anterior translation and varus tilting were significantly increased by 2.56 mm and $2.0^{\circ}$. The gaps between the unaffected limbs were also increased by 2.47 mm and $1.32^{\circ}$ after anesthesia. Although the stress radiographs were taken under anesthesia, the results were often smaller than the diagnostic value. Conclusion: Stress radiographs for painful chronic lateral ankle instability taken at the outpatient clinic might be inaccurate for diagnosis.

A Study on the make Fire Scenario for Residential Facility Combustible Materials

  • Kim, Dong-Eun;Lee, Dong-Yeol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.6
    • /
    • pp.137-143
    • /
    • 2021
  • In the case of residential facilities, general fire scenarios cannot be applied. Becauseit is difficult to quantify due to the types of combustibles and various fire loads. Existing research conducting surveys of combustibles, but research on fire characteristics is insufficient. Therefore, in this study, an Excel macro that can be quantified by experimenting with the HRR experiments of sofa, drawer, mattress, chair, desk and TV, which are typical combustibles. As a result of experimenting 6 loading combustibles in domestic residential facilities by using a furniture calorimeter, values of 2,391.26kW appeared from the sofa, 1,891.80kW from the drawer, 1,778.95kW from the mattress, 1,104kW from the chair, 291kW from the desk, and 135.09kW from the TV. Also, by applying the α value of the fire growth rate by classifying fire-growing speeds at NFPA 72 (National Fire Alarm Code 2007, Annex B), the mattress can be defined as Very Fast, the sofa and drawer Fast, the TV Slow, the desk Slow, and the chair Medium.

A Bacteriological Study on the Indoor-Shoes, Desk and Bag of Student의s (실내화, 책상, 책가방의 위생학적 고찰)

  • Kong, Dong
    • Journal of Environmental Health Sciences
    • /
    • v.4 no.1
    • /
    • pp.26-33
    • /
    • 1977
  • A bacteriological research of the school desks, bags and indoor-shoes was made from Oct. 2, 197 through May 28, 1976. The research included one girl's middle school, two boy's middle schools, two boy's high schools and 15 girl's high schools, alltogether 244 students from 28 schools, The research was analyzed and the results are as follows: 1) The research showed that 95% of the indoor-shoes materials were of cloth. Only 13% of the students carried the indoor-shoes in shoes sacks and 84.8% of them kept the shoes in schoolbags with books and lunchbox. 2) Only 5% of them cleaned their shoes every week and 79% cleaned every six. 3) 49.3% of the students kept the indoor-shoes in the school bag with other contents at home. 4) 88% of the bag was made of vinyl and 24.8% of the students carried their lunch in their bag without lunch box. 5) The research showed that 79.1% of the students never cleaned their bags. 6) In using the desk drawer, 58.2% of the students put their out-door shoes into the drawer, 18.9% of them kept their lunch in it, 11.9% used it keeping books alone and 11% keeping school bags with books. 7) 30.4% of the students had an experience of having cleaned their desks and 69.6% were unconcerned wirh desk-cleaning. 8) 34.4% of the indoor-shoes using school showed fecal coliform positive, 40.2% showed non-fecal coliform positive and 25.4% showed no reaction to IMViC. 9) The 34.4% of the fecal coliform positive showing schools, equivalant to 77 students, was composed of zero percents of girl's middle school, 18.2% of girl's high school, 36.4% of boy's middle school and 45.4% of boy's high school. 10) Among the 77 students, whose shoes showed fecal coliform positive, only 6.5% of them cleaned their shoes once in a week or a month and 62.3% of them cleaned them once in a six month. 11) The fccal coliform positive rate was higher in the cloth shoes materials than the vinyl materials. 12) The concrete-bottomed building higher positive rate (40.2%) than the wood-bottomed building (7.5%). 13) Even among the student's who frequently cleaned their desk drawer, 2.3% were in the positive, and among those who were unconcerned with drawer cleaning, 48.9% were involved in the positive. 14) In the fecal coliform positive rate of bags, 38.5% of the positive rate belonged to using indoor shoes while cleaning their class bottom with water, 53.8% belonged to using outdoor shoes while cleaning their class bottom with water, 7.7% belonged to using outdoor shoes while cleaning their class with oil.

  • PDF

Microbial Contamination in Kitchens and Refrigerators of Korea Households

  • Hong, Joonbae;Lim, Seung-Yong
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.4
    • /
    • pp.303-308
    • /
    • 2015
  • The objectives of this study were to investigate the microbial contamination level of domestic kitchen environments and to provide information to improve food safety in 50 domestic house kitchens located in Seoul, Incheon, and Gyeonggi-do. Dishcloth, chopping board, and refrigerator swabs were examined for the presence of coliforms, Salmonella spp., Campylobacter jejuni/coli, Escherichia coli, Listeria monocytogenes, and Staphylococcus aureus. The means and standard deviations of coliform counts for dishcloths was $4.8{\pm}1.84log\;CFU/100g$, chopping boards, and refrigerator drawers were $4.04{\pm}1.53$, $4.11{\pm}1.65log\;CFU/100cm^2$, respectively. Salmonella spp. and Campylobacter jejuni/coli were not detected in all samples. E. coli were detected in 3 on the dishcloths and 1 of 50 samples in the refrigerator drawer. Listeria monocytogenes was detected in the drawer of the refrigerator in 2 of 50 samples. In the case of Staphylococcus aureus, the detection on dishcloths, chopping boards, and drawers in refrigerators was 21, 12, and 14 of 50 samples, respectively. The results of microbiological tests of domestic kitchen utensils can be used to emphasize the importance of the sanitary conditions in domestic kitchen environments.

The Modified $Brostr{\ddot{o}}m$ Procedure for Chronic Lateral Ankle Instability (만성 족관절 외측 불안정성에 대한 $Brostr{\ddot{o}}m$ 변형 술식)

  • Song, Ha-Heon;Shim, Dae-Moo;Lee, Byoung-Chang;Kim, Dong-Churl;Cho, Yong-Woo;Yang, Jung-Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.81-85
    • /
    • 2004
  • Purpose: The purpose of this study is to evaluate the surgical results of modified $Brostr{\ddot{o}}m$ procedure for chronic lateral ankle instability and to assess whether or not associated injuries may affect postoperative satisfaction. Materials and Methods: Twenty- four patients with chronic lateral ankle instability were evaluated retrospectively from August 1998 to March 2002. Average age was 29.3 years. All patients were performed pre & postoperative ankle anteroposterior and lateral view, stress anterior drawer and varus test using Telos device, MRI and intraoperative arthroscopic evaluations before ligament reconstruction. Results: Of the 24 cases, 23 cases was improved more than average 12 points on AOFAS scales. On modified scales of Hamilton, 3 excellent, 20 good, 1 fair results. On stress view, average 2.2 mm difference was improved on anterior drawer test and average 1.7 degree on varus test. Associated injuries were 8 osteochondral defects, 4 anterior impingements, 2 loose bodies, 2 os subfibulare, 2 os submalleolare and 2 partial ruptures of peroneus brevis. 8 cases with no associated injuries rated excellent or good. Conclusion: The modified $Brostr{\ddot{o}}m$ procedure is believed to be an effective and successful method for chronic lateral ankle instability that didn't respond to conservative treatment. Because associated injuries in chronic lateral ankle instability may affect postoperative satisfaction, appropriate detection and treatment may need for postoperative satisfaction.

  • PDF

Design of Conformal Cooling Channels for the Mould of a Plastic Drawer of a Refrigerator by Analysis of Three-Dimensional Injection Moulding (3 차원 사출성형 해석을 통한 냉장고 플라스틱 서랍 제작용 사출 성형 금형의 형상적응형 냉각수로 설계)

  • Ahn, Dong-Gyu;Park, Min-Woo;Park, Seung-Hwa;Kim, Hyung-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1487-1492
    • /
    • 2010
  • The objective of this study is to design the conformal cooling channels for the mould of a plastic drawer of a refrigerator by analysis of three-dimensional injection molding. In order to obtain the desired design of the conformal cooling channels, the influence of the diameter and the position of the conformal cooling channels on the moulding characteristics and the product qualities were quantitatively examined. From the results of the examination, an optimal design of the conformal cooling channels, which ensures uniform cooling and minimum potential deformation of the molded drawers, was estimated. By comparing the designed mould and a conventional mould with linear cooling channels from the viewpoints of the product qualities as well as cooling and cycle times, it was shown that the mould with conformal cooling channels can simultaneously improve the productivity of the injection moulding process and the product qualities.

Biomechanical evaluation of a bioactive artificial anterior cruciate ligament

  • Guerard, Sandra;Manassero, Mathieu;Viateau, Veronique;Migonney, Veronique;Skalli, Wafa;Mitton, David
    • Advances in biomechanics and applications
    • /
    • v.1 no.4
    • /
    • pp.239-252
    • /
    • 2014
  • This study aimed to assess the biomechanical performance of a new generation of artificial ligament, which can be considered "bioactive" and "biointegrated," implanted in sheep. Thirty sheep were implanted: 15 sheep received the artificial ligament grafted with a bioactive polymer (grafted) and 15 received the artificial ligament without a bioactive polymer (non-grafted). The animals were sacrificed 3 or 12 months after implantation. The knee kinematics, namely flexion-extension, anterior drawer, and varus-valgus tests, were evaluated using a fully characterized custom-made device. Afterward, the specimens were tested under uniaxial tension until failure. The flexion-extension showed significant differences between (grafted or non-grafted) artificial and native ligaments 3 months after implantation. This difference became non-significant 12 months postoperatively. The anterior tibial drawer was significantly increased 3 months after implantation and remained significantly different only for non-grafted ligament 12 months after implantation. Twelve months after implantation, the differences between grafted and non-grafted ligament biomechanical properties were significant in terms of stiffness. In terms of load to failure, grafted ligaments seem to have had slightly better performance than non-grafted ligaments 12 months postoperatively. Overall these results suggest that grafted artificial ligaments have slightly better biomechanical characteristics than non-grafted artificial ligaments 12 months after implantation in sheep.

Feasibility of Manufacturing Desk and Chair with Curved Veneer Lamination (단판 적층성형 학생용 책상.의자의 제조적성)

  • Suh, Jin-Suk;Park, Jong-Young;Han, Ki-Man
    • Journal of the Korea Furniture Society
    • /
    • v.16 no.2 s.30
    • /
    • pp.59-65
    • /
    • 2005
  • As physical condition of students improves, there is a need to develop human body-friendly desk and chair for students. In this study, desks and chairs were manufactured with curved veneer lamination under high frequency heating and pressing, using ten wood species such as Japanese red pine, Korean pine, pitch pine, Japanese larch, yellow poplar, black locust, oak, radiata pine, beech, and birch. The performance of these products were evaluated. The results obtained were summarized as follows; With high frequency heating, the turned lamination of veneers with full size sheet ($3{\times}6\;feet$) prepared by rotary lathe peeling was successfully applied for making the members of desk top, leg frames of desk and chair. Bending strengths of desk tops were relatively greater for yellow poplar, black locust and red pine, which were similar to those of beech and birch. Bending strengths of desk legs were classified into greater species group (red pine, yellow poplar, larch) and lower species group (radiata pine, Korean pine, pitch pine). Compressive strengths of chair legs in parallel direction to the lamination were greater in black locust and larch. On the other hand, differences between outer and inner gap at the top and drawer bottom of desk top were rather larger for the laminations of birch and beech, and less for those of yellow poplar and pitch pine, showing greater stability of open drawer space. In results, yellow poplar, larch, pitch pine and red pine showed good appearance and strength properties at the curved veneer lamination. Accordingly, it was believed that these domestic woods were able to substitute for birch which was being imported for the use of veneer-laminates type furniture.

  • PDF