• 제목/요약/키워드: drainage-structure

검색결과 260건 처리시간 0.024초

복합 구조형 배수 배관재의 소음 및 결로 특성에 관한 연구 (A Study on the Noise and Condensation Characteristics of Complex Structure Drainage Pipe Materials)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제20권5호
    • /
    • pp.72-77
    • /
    • 2016
  • The present study investigates noise and condensation characteristics of polyvinyl chloride (PVC), which is widely used for drainage piping materials, complex double structure by comparing to those of PVC single structure piping materials. In addition, effects of insulation on drainage noise has been measured experimentally. As the results of the experiments, noise reduction effect of PVC complex double structure is superior to that of PVC single structure in terms of elbow and vertical piping materials which are employed for drainage pipes of toilet bowls and bathtub. The insulation barely have effect on the noise reduction in case of the PVC single structure since there is almost no changes in noise occurrence even though the insulation is applied on both elbow and vertical piping materials. Temperature differences between inside and outside of the pipes have been measures for the PVC single and complex double structures as well. In consequence, outside temperature of the PVC complex double structure is higher than that of the PVC single structure. The condensation occurrence time of the PVC complex double structure shows a distinct difference from that of the PVC single structure, thus, the PVC complex double structure has outstanding effect on preventing the condensation.

지하구조물 부력방지를 위한 연직배수시스템의 적용성 연구 (A Study on the Application of Vertical Drainage System for Resisting Uplift of Sub-structure)

  • 천병식;여유현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.183-190
    • /
    • 2001
  • A sub-structure is uplift if the floating greater than dead load of a structure. When such occasion arise, a structure sustain damage. In general, the measures for floating prevention of structure are a permanent anchor method and a drainage method. The primary construction cost of a permanent anchor method is heavy. And a drainage method is needed maintenance management long term. At this point, the measures for floating prevention of a notion being requires the other days. Therefore, at this study a simple construction and a economic vertical drainage system was developed. The findings be used in the in-situ and gave careful consideration to an application. The result of examination, this system considering a characteristic of coefficient of permeability for the ground controls occurrence of floating despite the water level rise of the ground, which a period of construction get shorter compared with other methods, which understood that measures satisfactory in the financial aspect. Especially, A structure occurring effects of flatting under the course of construction made use of it. As the result of the effect of it was confirmed by construction.

  • PDF

농업기반 수리구조물의 노후손상 유형화 분석 (Analysis for the Types of Damages and Deterioration in Irrigation and Drainage Structures)

  • 김관호
    • 한국관개배수논문집
    • /
    • 제14권1호
    • /
    • pp.67-79
    • /
    • 2007
  • Concrete repair and reinforcement is a complex process, presenting unique challenges very different from those experience in the field of construction. The purpose of this study is to analyze the pattern and mechanism of deteriorations in irrigation and drainage structure. Damage and deteriorated structures are classified with several types. This provides a survey of crack repair methods, including a summary of the procedures that are being used. It is systematically evaluated with the disintegration on irrigation & drainage structure; drainage sluice gate, pumping station, drainage pumping station. Following the evaluation of the irrigation & drainage structure, a suitable repair and reinforcing procedure can be selected based on this report

  • PDF

Utilization of the Outflowing Groundwater Resources in an Underpass Structure

  • Jin, Kyu-Nam;Park, Jae-Hyeon;Lee, Jung-Min;Lee, Sang-Ho
    • Environmental Engineering Research
    • /
    • 제18권3호
    • /
    • pp.117-121
    • /
    • 2013
  • For underpasses in Yeongjong Sky City business district, the guided drainage system, as a buoyancy prevention system has been designed, and is under construction. This paper investigates the safety of the guided drainage system for underpass structures being constructed in Yeongjong Sky City business district. This paper also calculates the amount of outflowing groundwater generated by the guided drainage system, and proposes alternative usages of the water. In order to investigate safety and field applicability of the guided drainage system for underpasses, characteristics of the surface flow for the area of interest have been analyzed, and the flow change of groundwater following the underpass structure construction has been evaluated using the 3-dimensional groundwater program MODFLOW. The influence of ground water on safety of the underpass structures has been calculated by FLAC2D analysis. For alternative usages for the outflowing groundwater generated by the guided drainage system, utilization methods of the outflowing groundwater in national and international resources have been researched. The amount of an outflowing groundwater to be generated in the area of interest has been analyzed, and efficient potential usages of this groundwater have been researched. When guided drainage technique is applied, the change in flow of groundwater must be evaluated and considered as safety factor relating to the buoyancy of the structure. As a result, safety factor demonstrated more than 1.2, meaning that the underpass structure is safe. The amount of subsoil drain generated by the guided drainage system was also analyzed. The quality and amount of water satisfied the standards and volume requirements, so as to make it applicable for a number of uses, such as X, Y, and Z, and should prove to be a valuable resource as the circumstances of the neighboring area change over time. These resources can be used as basic data for future urban water circulation studies, as well as generating research of alternative water usages.

배수 약간 불량지 논에서 PVC 파이프 암거배수에 의한 사료작물 재배 (Growth and Tield Performance of Selected Forage Crops Cultivated on Imperfectly Drained Paddy Field under Subsurface Drainage by PVC Pipes)

  • 김정갑;박근제;김건엽;한민수
    • 한국초지조사료학회지
    • /
    • 제16권3호
    • /
    • pp.219-224
    • /
    • 1996
  • Silage comkv, suwwn 19). sorghum $\times$ sudangrass(p. 988) and winter ryeNaton) were cultivated on imperfectly drained paddy field under two different draining methods, subsurface darinage by PVC pipes and open ditsched surface drainage. The crops were harvested at the stage of hard dough for corn and soft dough for wrghum and rye. The soil physical properties. soil colors. soil structure and soil wetness were improved in the subsurface drainage. Gravitational water table occured depth in 110 cm(dry season)~75cm(rain season). In soil profile description, yellowish brown with yellowish red mottles and well developed granular structure were found in the surface A horizon. The portion of solid phase in subsoils(B horizon) was reduced from 48.6%(undrained) to 43.7 %. A blocky structure with dark gray to gray were described in the open ditsched surface drainage. Severe wet depression of the crops was observed due to it's higher moisture contents, where the gravitational water occured depth in 25~37cm during the rainy season. The chemical properties of paddy soils were less affected by drainage methods. The concentration of available phosphate. organic matter and exchangeable K, Ca and Mg were decreased in the subsurface drained soils. The annual dry matter yields of com-rye cropping were 17.8 ton in the undrained, 21.6 ton in the open ditsch drainage and 35.9 ton/ha in the subsurface drainage.

  • PDF

배수관의 구조소음과 소음저감에 관한 연구 (A Study on the Structure-borne Noise and Noise Reduction of Drainage Pipes)

  • 류봉조;이규섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.194-202
    • /
    • 2009
  • The paper deals with the countermeasure against structure-borne noise source and noise reduction of drainage pipes. Recently, the problem the problem of the toilet drain noise of an apartment house has been become the center of public interest and a target of public grievance. Generally, the drain noise of a toilet in the apartment house has a pink noise characteristics below 2 kHz level, and therefore, the structure-borne noise has a great effect on the entire drain noise. In order to measure the transmission loss for various kinds of pipes such as PVC pipes, cast-iron pipes and newly developed AS pipes, experimental setup containing speakers as a sound source was designed and manufactured. The second-stories measurement room with a small size anechoic chamber was constructed and the noise level for different kinds of drainage pipes was measured by the sound level meter. Through the experimental research in the study, noise reduction capacity for various kinds of drainage pipes and countermeasures against structure-borne noise source are demonstrated.

  • PDF

지하수 유출수 조건을 고려한 주방식 지하구조의 배수시스템 연구 (A study on drainage system of the room-and-pillar underground structure considering groundwater conditions)

  • 이철호;현영환;황제돈;장수호
    • 한국터널지하공간학회 논문집
    • /
    • 제17권6호
    • /
    • pp.675-683
    • /
    • 2015
  • 주방식 지하구조물은 주방식 채광법의 개념을 이용한 지하구조물 건설 방법이다. 주방식 공법에서 배수는 터널의 싱글쉘 개념과 유사하며, 주방식 지하구조의 장기적인 안정화를 위해서 복공 뒷면의 지하수를 배수하여 지하수위를 사전 저감시키는 방식이 유효하다. 그러나 배수공에 의한 지하수위 저감 방식은 지하 굴착시 굴착면에 지하수압이 작용하지 않거나 발생 용수량이 크지 않다면 배수공은 필요치 않게 된다. 본 연구에서는 지하 굴착시 발생용수량에 따른 배수공 적용 유무를 검토하여 주방식 지하구조에서 배수공 적용 유무를 판단하는 기준을 제안하고자 하며, 배수공 적용이 불필요한 구간에 대해서는 숏크리트를 통한 유도 배수시스템을 제안하고자 한다.

배수갑문 물받이의 수리현상에 관한 연구 (A Study on the Hydroulic Phenomenon at the Douvstream Channel of the Drainage Sluice)

  • 이희영
    • 한국농공학회지
    • /
    • 제18권4호
    • /
    • pp.4218-4225
    • /
    • 1976
  • To insure the safety of the drainage sluice, topogrophical change due to erosion as well as capability of discharging the design flow in a very important factor. In consideration of the fact that the drainage sluice is built in the sea, its construction has many topographically restricted problems and naturally requires a completeness of research and experiment. This thesis is a comparative and analytic study of discharging flow acting on the erosion at the bottom of the structure on the basis of the measured velocity on the downstream channel of the drainage sluice. (1) The measured velocity shows a little higher values than the computed velocity, because the measured velocity was observed at the surface of the stream. There fore, it is reasonable that the compated velocity should be taken in this study. (2) The field observation was conducted to have the measurement of the flow velocity without surveying the area of flow. Therefore, the coefficient of discharge could not be computed. The survey of the area of flow is planned to be conducted along with the measurement of the flow velocity. (3) The apron of the drainage sluice is free discharging type and it was designed to be about 80m in length less than it should be. (4) The apron of free flow discharging type should have a solid foundation to protect the structure by preventing erosion damage to upstream and downstream channels against weathering of rock and strong torrent. Whether free flow discharging type or energy-dissipating type is best chosen depends on the topographical condition of the forage site, therefore, there would be a comparative study before the final decision was made about the protrection for the structure. (5) It is considered to be appropriate that the design and construction of the drainage sluice should have a complete study which is based on hydraulie model test before the type of protection is decided. (6) It is much requested that a variety of experiment equipments be installed and observed to study the protection for the drainage sluice.

  • PDF

왕겨충전에 따른 암거의 제염 효과 (Desalinization Effect of Subsurface Drainage System with Rice Hull Packing)

  • 이승헌;안열;류순호;정영상
    • 한국농공학회지
    • /
    • 제43권5호
    • /
    • pp.63-69
    • /
    • 2001
  • The main purpose of this study is to seek desalinization effect of subsurface drainage system with rice hull packing in Dae-Ho Reclaimed Land. After 4 years installed sub-surface drainage system, distribution of drained water electric conductivity (ECw) was 4.43~12.78 ds/m. The soil profile showed partial development of the soil structure and compaction of subsoils with increased bulk density. The bulk density of the subsoil was 1.42~1.66 g/cm$^3$, which might limit root growth. The soil color changed near the drainage pipe line. Distribution of soil extract solution ECe and SAR as subsurface drainage pipe position and drainage canal distance showed desalinization effect of subsurface drainage system with rice hull packing as widening effective zone of subsurface drainage pipe.

  • PDF

수리구조물의 보수보강 DB구축 (Repairing & Reforcing DB Construction for Irrigation & Drainage Structure)

  • 김관호;박광수;김명원;이준구;유정훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.189-192
    • /
    • 2006
  • Following the evaluation of the irrigation & drainage structure, a suitable repair and reinforcing procedure can be selected based on this report. Successful procedures take into account the causes of the crack. This provides a survey of crack repair methods, including a summary of the characteristics of the cracks that may be repaired with each procedure, the type of irrigation & drainage structure that have been repaired and a summary of the procedures that are used. Readers are also directly contacted to the website(http:/rri.karico.co.kr/rricon). This report is intended to support the purposes, philosophy, and needs, using easily understood graphics and photos from the construction fields. The results of this study will be distributed to the public official in technical post, the operator in construction site and the member of Korea Agricultural & Rural Infrastructure Corporation and etc.

  • PDF