• Title/Summary/Keyword: drainage-structure

Search Result 260, Processing Time 0.03 seconds

A Study on the Noise and Condensation Characteristics of Complex Structure Drainage Pipe Materials (복합 구조형 배수 배관재의 소음 및 결로 특성에 관한 연구)

  • Kim, Jae-Dol
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.72-77
    • /
    • 2016
  • The present study investigates noise and condensation characteristics of polyvinyl chloride (PVC), which is widely used for drainage piping materials, complex double structure by comparing to those of PVC single structure piping materials. In addition, effects of insulation on drainage noise has been measured experimentally. As the results of the experiments, noise reduction effect of PVC complex double structure is superior to that of PVC single structure in terms of elbow and vertical piping materials which are employed for drainage pipes of toilet bowls and bathtub. The insulation barely have effect on the noise reduction in case of the PVC single structure since there is almost no changes in noise occurrence even though the insulation is applied on both elbow and vertical piping materials. Temperature differences between inside and outside of the pipes have been measures for the PVC single and complex double structures as well. In consequence, outside temperature of the PVC complex double structure is higher than that of the PVC single structure. The condensation occurrence time of the PVC complex double structure shows a distinct difference from that of the PVC single structure, thus, the PVC complex double structure has outstanding effect on preventing the condensation.

A Study on the Application of Vertical Drainage System for Resisting Uplift of Sub-structure (지하구조물 부력방지를 위한 연직배수시스템의 적용성 연구)

  • Chun, Byung-Sik;Yeoh, Yoo-Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.183-190
    • /
    • 2001
  • A sub-structure is uplift if the floating greater than dead load of a structure. When such occasion arise, a structure sustain damage. In general, the measures for floating prevention of structure are a permanent anchor method and a drainage method. The primary construction cost of a permanent anchor method is heavy. And a drainage method is needed maintenance management long term. At this point, the measures for floating prevention of a notion being requires the other days. Therefore, at this study a simple construction and a economic vertical drainage system was developed. The findings be used in the in-situ and gave careful consideration to an application. The result of examination, this system considering a characteristic of coefficient of permeability for the ground controls occurrence of floating despite the water level rise of the ground, which a period of construction get shorter compared with other methods, which understood that measures satisfactory in the financial aspect. Especially, A structure occurring effects of flatting under the course of construction made use of it. As the result of the effect of it was confirmed by construction.

  • PDF

Analysis for the Types of Damages and Deterioration in Irrigation and Drainage Structures (농업기반 수리구조물의 노후손상 유형화 분석)

  • Kim, Kwan-Ho
    • KCID journal
    • /
    • v.14 no.1
    • /
    • pp.67-79
    • /
    • 2007
  • Concrete repair and reinforcement is a complex process, presenting unique challenges very different from those experience in the field of construction. The purpose of this study is to analyze the pattern and mechanism of deteriorations in irrigation and drainage structure. Damage and deteriorated structures are classified with several types. This provides a survey of crack repair methods, including a summary of the procedures that are being used. It is systematically evaluated with the disintegration on irrigation & drainage structure; drainage sluice gate, pumping station, drainage pumping station. Following the evaluation of the irrigation & drainage structure, a suitable repair and reinforcing procedure can be selected based on this report

  • PDF

Utilization of the Outflowing Groundwater Resources in an Underpass Structure

  • Jin, Kyu-Nam;Park, Jae-Hyeon;Lee, Jung-Min;Lee, Sang-Ho
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.117-121
    • /
    • 2013
  • For underpasses in Yeongjong Sky City business district, the guided drainage system, as a buoyancy prevention system has been designed, and is under construction. This paper investigates the safety of the guided drainage system for underpass structures being constructed in Yeongjong Sky City business district. This paper also calculates the amount of outflowing groundwater generated by the guided drainage system, and proposes alternative usages of the water. In order to investigate safety and field applicability of the guided drainage system for underpasses, characteristics of the surface flow for the area of interest have been analyzed, and the flow change of groundwater following the underpass structure construction has been evaluated using the 3-dimensional groundwater program MODFLOW. The influence of ground water on safety of the underpass structures has been calculated by FLAC2D analysis. For alternative usages for the outflowing groundwater generated by the guided drainage system, utilization methods of the outflowing groundwater in national and international resources have been researched. The amount of an outflowing groundwater to be generated in the area of interest has been analyzed, and efficient potential usages of this groundwater have been researched. When guided drainage technique is applied, the change in flow of groundwater must be evaluated and considered as safety factor relating to the buoyancy of the structure. As a result, safety factor demonstrated more than 1.2, meaning that the underpass structure is safe. The amount of subsoil drain generated by the guided drainage system was also analyzed. The quality and amount of water satisfied the standards and volume requirements, so as to make it applicable for a number of uses, such as X, Y, and Z, and should prove to be a valuable resource as the circumstances of the neighboring area change over time. These resources can be used as basic data for future urban water circulation studies, as well as generating research of alternative water usages.

Growth and Tield Performance of Selected Forage Crops Cultivated on Imperfectly Drained Paddy Field under Subsurface Drainage by PVC Pipes (배수 약간 불량지 논에서 PVC 파이프 암거배수에 의한 사료작물 재배)

  • 김정갑;박근제;김건엽;한민수
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.16 no.3
    • /
    • pp.219-224
    • /
    • 1996
  • Silage comkv, suwwn 19). sorghum $\times$ sudangrass(p. 988) and winter ryeNaton) were cultivated on imperfectly drained paddy field under two different draining methods, subsurface darinage by PVC pipes and open ditsched surface drainage. The crops were harvested at the stage of hard dough for corn and soft dough for wrghum and rye. The soil physical properties. soil colors. soil structure and soil wetness were improved in the subsurface drainage. Gravitational water table occured depth in 110 cm(dry season)~75cm(rain season). In soil profile description, yellowish brown with yellowish red mottles and well developed granular structure were found in the surface A horizon. The portion of solid phase in subsoils(B horizon) was reduced from 48.6%(undrained) to 43.7 %. A blocky structure with dark gray to gray were described in the open ditsched surface drainage. Severe wet depression of the crops was observed due to it's higher moisture contents, where the gravitational water occured depth in 25~37cm during the rainy season. The chemical properties of paddy soils were less affected by drainage methods. The concentration of available phosphate. organic matter and exchangeable K, Ca and Mg were decreased in the subsurface drained soils. The annual dry matter yields of com-rye cropping were 17.8 ton in the undrained, 21.6 ton in the open ditsch drainage and 35.9 ton/ha in the subsurface drainage.

  • PDF

A Study on the Structure-borne Noise and Noise Reduction of Drainage Pipes (배수관의 구조소음과 소음저감에 관한 연구)

  • Ryu, B.J.;Lee, G.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.194-202
    • /
    • 2009
  • The paper deals with the countermeasure against structure-borne noise source and noise reduction of drainage pipes. Recently, the problem the problem of the toilet drain noise of an apartment house has been become the center of public interest and a target of public grievance. Generally, the drain noise of a toilet in the apartment house has a pink noise characteristics below 2 kHz level, and therefore, the structure-borne noise has a great effect on the entire drain noise. In order to measure the transmission loss for various kinds of pipes such as PVC pipes, cast-iron pipes and newly developed AS pipes, experimental setup containing speakers as a sound source was designed and manufactured. The second-stories measurement room with a small size anechoic chamber was constructed and the noise level for different kinds of drainage pipes was measured by the sound level meter. Through the experimental research in the study, noise reduction capacity for various kinds of drainage pipes and countermeasures against structure-borne noise source are demonstrated.

  • PDF

A study on drainage system of the room-and-pillar underground structure considering groundwater conditions (지하수 유출수 조건을 고려한 주방식 지하구조의 배수시스템 연구)

  • Lee, Chulho;Hyun, Younghwan;Hwang, Jedon;Chang, Soo-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.6
    • /
    • pp.675-683
    • /
    • 2015
  • The room-and-pillar construction method for underground space is adopted from the room-and-pillar mining method which is one of the most popular underground mining method in the world. Drainage system in the room-and-pillar underground construction method can be similar with the concept of single shell in tunnel because additional reinforcement except the TSL (thin spray-on liner) is not applied in the room-and-pillar construction method. That is, to decrease groundwater level and maintain safety in tunnel, the drainage pin hole inside lining (shotcrete) can be used. However, if total amount of outflow in the underground structure is relatively small or groundwater is not detected, such drainage system will not be useful and cause additional construction cost. In this study, outflow of conventional tunnels in South Korea was investigated and the criteria to determine whether the drainage pin hole is effective was suggested. And the guided drainage system was suggested when drainage pin hole was not applied in the room-and-pillar construction method.

A Study on the Hydroulic Phenomenon at the Douvstream Channel of the Drainage Sluice (배수갑문 물받이의 수리현상에 관한 연구)

  • 이희영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.4
    • /
    • pp.4218-4225
    • /
    • 1976
  • To insure the safety of the drainage sluice, topogrophical change due to erosion as well as capability of discharging the design flow in a very important factor. In consideration of the fact that the drainage sluice is built in the sea, its construction has many topographically restricted problems and naturally requires a completeness of research and experiment. This thesis is a comparative and analytic study of discharging flow acting on the erosion at the bottom of the structure on the basis of the measured velocity on the downstream channel of the drainage sluice. (1) The measured velocity shows a little higher values than the computed velocity, because the measured velocity was observed at the surface of the stream. There fore, it is reasonable that the compated velocity should be taken in this study. (2) The field observation was conducted to have the measurement of the flow velocity without surveying the area of flow. Therefore, the coefficient of discharge could not be computed. The survey of the area of flow is planned to be conducted along with the measurement of the flow velocity. (3) The apron of the drainage sluice is free discharging type and it was designed to be about 80m in length less than it should be. (4) The apron of free flow discharging type should have a solid foundation to protect the structure by preventing erosion damage to upstream and downstream channels against weathering of rock and strong torrent. Whether free flow discharging type or energy-dissipating type is best chosen depends on the topographical condition of the forage site, therefore, there would be a comparative study before the final decision was made about the protrection for the structure. (5) It is considered to be appropriate that the design and construction of the drainage sluice should have a complete study which is based on hydraulie model test before the type of protection is decided. (6) It is much requested that a variety of experiment equipments be installed and observed to study the protection for the drainage sluice.

  • PDF

Desalinization Effect of Subsurface Drainage System with Rice Hull Packing (왕겨충전에 따른 암거의 제염 효과)

  • Lee, Seung-Heon;An, Yeoul;Yoo, Sun-Ho;Jung, Yeong-Sang
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.5
    • /
    • pp.63-69
    • /
    • 2001
  • The main purpose of this study is to seek desalinization effect of subsurface drainage system with rice hull packing in Dae-Ho Reclaimed Land. After 4 years installed sub-surface drainage system, distribution of drained water electric conductivity (ECw) was 4.43~12.78 ds/m. The soil profile showed partial development of the soil structure and compaction of subsoils with increased bulk density. The bulk density of the subsoil was 1.42~1.66 g/cm$^3$, which might limit root growth. The soil color changed near the drainage pipe line. Distribution of soil extract solution ECe and SAR as subsurface drainage pipe position and drainage canal distance showed desalinization effect of subsurface drainage system with rice hull packing as widening effective zone of subsurface drainage pipe.

  • PDF

Repairing & Reforcing DB Construction for Irrigation & Drainage Structure (수리구조물의 보수보강 DB구축)

  • Kim, Kwan-Ho;Park, Kwang-Su;Kim, Myeong-Won;Lee, Joon-Gu;Yoo, Jung Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.189-192
    • /
    • 2006
  • Following the evaluation of the irrigation & drainage structure, a suitable repair and reinforcing procedure can be selected based on this report. Successful procedures take into account the causes of the crack. This provides a survey of crack repair methods, including a summary of the characteristics of the cracks that may be repaired with each procedure, the type of irrigation & drainage structure that have been repaired and a summary of the procedures that are used. Readers are also directly contacted to the website(http:/rri.karico.co.kr/rricon). This report is intended to support the purposes, philosophy, and needs, using easily understood graphics and photos from the construction fields. The results of this study will be distributed to the public official in technical post, the operator in construction site and the member of Korea Agricultural & Rural Infrastructure Corporation and etc.

  • PDF