• 제목/요약/키워드: drainage water volume

검색결과 88건 처리시간 0.024초

GIS L-THIA를 이용한 도시화에 따른 유출과 비점원오염 영향 평가 (Assessing the impact of urbanization on runoff and non-point source pollution using the GIS L-THIA)

  • 윤라영;김동희;권혁현;신승철;손광익
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1802-1806
    • /
    • 2006
  • It is important to consider the effects of land-use changes on surface runoff, stream flow, and groundwater recharge. Expansion of urban areas significantly impacts the environment in terms of ground water recharge, water pollution, and storm water drainage. Increase of impervious area due to urbanization leads to an increase in surface runoff volume, contributes to downstream flooding and a net loss in groundwater recharge. Assessment of the hydrologic impacts or urban land-use change traditionally includes models that evaluate how land use change alters peak runoff rates, and these results are then used in the design of drainage systems. Such methods however do not address the long-term hydrologic impacts of urban land use change and often do not consider how pollutants that wash off from different land uses affect water quality. L-THIA (Long-Term Hydrologic Impact Assessment) is an analysis tool that provides site-specific estimates of changes in runoff, recharge and non point source pollution resulting from past or proposed land-use changes. It gives long-term average annual runoff for a land use configuration, based on climate data for that area. In this study, the environmental and hydrological impact from the urbanized basin had been examined with GIS L-THIA in Korea.

  • PDF

논의 배수물꼬의 유량에 관한 기초연구 (A Study on the Outlet Drain Discharge from Paddy Field)

  • 최진규;김현영;손재권
    • 한국농공학회지
    • /
    • 제39권2호
    • /
    • pp.134-142
    • /
    • 1997
  • This study was performed to evaluate the drain runoff characteristics from one paddy field, and to provide the basic data required for the determination of flood discharge and unit drainage water for drainage improvement and farmland consolidation. For this purpose, under the assumption that drain discharge from paddy field was similar to outflow of reservoir, runoff model based on storage equation was applied to the experimental field, and simulated results were compared to the measured discharge at weir point. To estimate effective storage volume of paddy field with water depth, 4 regression formula were examined such as linear, exponential, power, and combined. From the observed runoff characteristics, it was shown to be 3.3~16.3${\ell}$/sec in weir discharge, 57.2~98% in runoff ratio, and relative error of simulated result was 3.0~39.4%, 8.5 ~56.0 % for peak flow and runoff ratio, respectively. Curve number by SCS method was calculated as mean value of 96.4 using measured rainfall and runoff data, it was considered relatively high because paddy field has generally flooding depth contrary to the upland watershed area.

  • PDF

Effects of Physical Characteristics on a Nutrient-Chlorophyll Relationship in Korean Reservoirs

  • Hwang, Soon-Jin;Jeon, Ji-Hong;Ham, Jong-Hwa;Kim, Ho-Sub
    • 한국농공학회지
    • /
    • 제44권7호
    • /
    • pp.64-73
    • /
    • 2002
  • This study was performed to evaluate effects of physical characteristics of both watershed and reservoir on nutrient-chlorophyll relationship in Korean reservoirs. Simple linear models were developed with published data in Korea including 415 reservoirs and 11 multi-purpose dams, and physico-chemical parameters of reservoirs and characteristics relationship of models were analyzed. Theoretical residence time in Korean reservoirs was strongly correlated with the ratio of TA/ST (drainage area + surface area / storage volume) in the logarithmic function. As a result of monthly nutrients-chlorophyll-a regression analysis, significant Chl-a-TP relationship appeared during May~July. The high Chl-a yields per total phosphorus appeared during this time (R$\^$2/=0.51, p<0.001, N= 1088). Chlorophyll-a demonstrated much stronger relationship with TP. than TN. Seasonal algal-nutrient coupling were closely related with N:P ratio in the reservoir water, and it was, in turn, dependent on the monsoon climatic condition (precipitation). Based on the results of regression analysis and high N:P ratio, a major limiting factor of algal growth appeared to be phosphorus during this time. Unlikely TA/ST ratio, DA/SA ratio (drainage area f surface area) was likely to influence directly on the nutrient-Chl-a relationship, indicating that if storage volume and inflowing water volume were the same, algal biomass could be developed more in reservoirs with large surface area. Thus, DA/SA ratio seemed to be an important factor to affect the development of algal biomass in Korean reservoirs. With low determination coefficient of TP-Chl-a relationship, our findings indicated not only nutrient (phosphorus) but also other physical factors, such as DA/SA ratio, may affect algal biomass development in Korean reservoirs, where actual residence time appears to be more closely related to reservoir surface area rather than storage volume.

도시유역 CSOs 처리를 위한 저류형시스템 설계용량 산정 (Estimation of Storage Capacity for CSOs Storage System in Urban Area)

  • 조덕준;이정호;김명수;김중훈;박무종
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.490-497
    • /
    • 2007
  • A Combined sewer overflows (CSOs) are themselves a significant source of water pollution. Therefore, the control of urban drainage for CSOs reduction and receiving water quality protection is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as stormwater detention storage is highly dependant on the temporal variability of storage capacity available (which is influenced by the duration of interevent dry periods) as well as the infiltration capacity of soil and recovery of depression storage. As a result, a continuous approach is required to adequately size such facilities. This study for the continuous long-term analysis of urban drainage system used analytical probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model have evolved that offer much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics of the subject area using analytical probabilistic model. This study presented the average annual COSs and number of COSs when the interceptor capacity is in the range $3{\times}DWF$ (dry weather flow). Also, calculated the average annual mass of pollutant lost in CSOs using Event Mean Concentration. Finally, this study presented a decision of storage volume for CSOs reduction and water quality protection.

간척지 논 농업배수 처리에 적합한 인공습지 설계 기법 (Constructed Wetland Design Method to Treat Agricultural Drainage from Tidal Reclaimed Paddy Areas)

  • 장정렬;신유리;정지연;최강원
    • 한국관개배수논문집
    • /
    • 제18권1호
    • /
    • pp.4-17
    • /
    • 2011
  • The standard design methodology was suggested to construct wetland system for reducing non-point source pollution from Saemangeum reclaimed paddy land. To set for the design flow and concentrations, runoff and water quality survey were conducted during the irrigation period in 2008 at Gyehwa reclaimed paddy land located at near Saemangeum lake. It is rational that 1ha is the optimum constructed wetland size. To meet this size, the moderate drainage area of reclaimed paddy field was 50ha under the conditions that rainfall is 30mm, average runoff coefficient is 0.83, and runoff capture ratio is 0.6. At these condition, the runoff volume from 50ha was 10,520 $m^3/d$ including base flow during irrigation period. To select the optimum wetland system, several case studies were conducted by focusing on the tidal reclaimed land areas having wetland systems in Seokmun. Pond-Wetland system was selected as the standard model because of showing the highest reduction efficiency. Single variable regression equation were delivered to estimate effluent water concentrations from the designed wetland by using long-term monitoring data from the Seokmun experiment site. The effluent concentration from the designed wetland using these equation were showed moderately range.

  • PDF

연속 강우-유출 모의기법을 이용한 최적 CSOs 산정에 관한 연구 (A Study of Optimal-CSOs by Continuous Rainfall/Runoff Simulation Techniques)

  • 조덕준;김명수;이정호;김중훈
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.1068-1074
    • /
    • 2006
  • For receiving water quality protection a control systems of urban drainage for CSOs reduction is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as storm-water detention storage is highly dependant on the temporal variability of storage capacity available as well as the infiltration capacity of soil and recovery of depression storage. For the continuous long-term analysis of urban drainage system this study used analytical probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model has evolved that offers much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics of the subject area using analytical probabilistic model. Runoff characteristics manifested the unique characteristics of the subject area with the infiltration capacity of soil and recovery of depression storage and was examined appropriately by sensitivity analysis. This study presented the average annual CSOs, number of CSOs and event mean CSOs for the decision of storage volume.

중.저준위 방사성폐기물의 천층처분을 위한 인공방벽 실증시험시설의 건설 및 운전 경험 (Construction and Operational Experiences of Engineered Barrier Test Facility for Near Surface Disposal of LILW)

  • Jin-Beak Park;Se-Moon Park;Chang-Lak Kim
    • 방사성폐기물학회지
    • /
    • 제2권1호
    • /
    • pp.23-34
    • /
    • 2004
  • To validate the previous conceptual design of cover system, construction of the engineered barrier test facility is completed and the performance tests of the disposal cover system are conducted. The disposal test facility is composed of the multi-purpose working space, the six test cells and the disposal information space for the PR center. The dedicated detection system measures the water content, the temperature, the matric potential of each cover layer and the accumulated water volume of lateral drainage. Short-term experiments on the disposal cover layer using the artificial rainfall system are implemented. The sand drainage layer shows the satisfactory performance as intended in the design stage. The artificial rainfall does not affect the temperature of cover layers. It is investigated that high water infiltration of the artificial rainfall changes the matric potential in each cover layer. This facility is expected to increase the public information about the national radioactive waste disposal program and the effort for the safety of the planned disposal facility.

  • PDF

임도 횡단배수구의 유출구 피해 예측에 관한 연구 (A Study on Outlet Damage Prediction of Pipe Culverts in Forest Road)

  • 김명환;황진성;유영민;차두송
    • 한국산림과학회지
    • /
    • 제107권3호
    • /
    • pp.278-286
    • /
    • 2018
  • 본 연구는 강원대학교 학술림 임도를 대상으로 횡단배수구의 유출구 피해 유무에 영향을 미치고 있는 총 10개 인자를 조사하여 피해특성을 파악하였다. 그 결과는 다음과 같다. 임도횡단배수구 피해유무에 영향을 미치지 않은 인자는 배수구의 종단위치, 횡단위치, 토질 및 관암거 높이이며, 피해영향에 관련된 인자는 유출구 위치, 도수로 유무, 관암거 직경, 관암거 경사, 집수정 크기 등의 순으로 영향을 미치고 있다. 또한 이들 인자를 이용하여 임도횡단배수구 유출구 피해유무 예측을 위한 판별함수식을 도출하였으며, 판별적중률은 68.8%로 산출되었다.

액상화 방지를 위한 진동쇄석말뚝에 관한 기초적 연구 (A Fundamental Study on Vibrated Crushed-stone Pile for the Improvement of Liquefaction Resistance)

  • 천병식
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.105-111
    • /
    • 2000
  • If a saturate sand is subjected to ground vibrations it tends to compact and decrease in volume. if drainage is unable to occur the tendency to decrease in volume results in an increase in pore water pressure and if the pore water pressure build up to the point at which it is equal to the overburden pressure the effective stress becomes zero the sand loses its strength completely. This phenomenon is called "Liquefaction" It is associated primarily but not exclusively with saturated cohesion soils. The attention and study on liquefaction have been growing since the earthquake in Niigita Japan in 1964. Many researchers on liquefaction effect have been carried out in many countries under the potential influence of earthquake including Japan. However little research on liquefaction has been reported in Korea because Korea has been considered to be safe from earthquake. The term "liquefaction" is only known among geotechnical engineers,. In this paper overview of liquefaction and the evaluation on the applicability of vibrated crushed-stone pile as a liquefaction prevention method are presented.ethod are presented.

  • PDF

광센서를 이용한 실시간 중환자 요량감시 장치 (Real-time urine monitoring system for intensive care patient using optical sensor)

  • 김종명;이진영;홍주현;임승운;차은종;이태수
    • 센서학회지
    • /
    • 제17권1호
    • /
    • pp.81-85
    • /
    • 2008
  • This paper addressed real-time urine monitoring device for intensive care patients. The device was developed to detect and count each urine drop using optical sensor and calculate the current urine output volume and its hourly rate. In experiment, the water volume scale of drainage bottle was observed and compared with the count of the device so that the volume of each drop was found to vary with the dropping rate per minute. From this measurement, the relationship equation was derived to estimate the total water volume from the drop rate (correlation coefficient : r= 0.99). The developed device could be applied to count patient's urine drop successfully. Therefore, this device can be used to monitor intensive care patient's urine status in real-time.