A Computational Study on the Pressure Loss of Intake System for the Combat Vehicle (전투차량 흡기시스템의 압력손실에 관한 수치적 연구)

  • Moon, Seong-Mok;An, Su-Hong;Lee, Kyoung-Hoon;Woo, Kwan-Je
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.3
    • /
    • pp.25-31
    • /
    • 2012
  • A computational study on the improvement of the pressure loss of intake system, which is located at engine manifold of the combat vehicle, has been conducted using a finite-volume-based, Reynolds-Averaged Navier-Stokes (RANS) solver. The computational result of the pressure loss through the air cleaner is in good agreement with equivalent experimental data. A parametric study was done for improving of the pressure loss of intake system over the baseline case. The effects of five primary parameters such as the height of inlet, the width of interconnection pipe, the shape of drain chamber and the diameter of filter housing were considered in this study. Consequently, this computational investigation can contribute to finding an optimal guideline for the idea of improvement in the pressure loss of intake system.

Evaluation of the Smear Zone by Numerical Analysis Method (수치해석에 의한 스미어 존 평가)

  • Kang, Yun;Nam, Yelwoo;Lee, Seombeom;Kim, Hongtaek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.3
    • /
    • pp.35-40
    • /
    • 2007
  • The vertical drain method recently being used in Korea is divided into the sand drain method, the pack drain method, the paper drain method, and the PBD method according to the drainage. However, these methods generate the disturbed zone called the smear zone when the drainage is penetrated into the in-situ ground. The characteristics of the smear zone generated cause the problems that the coefficient of permeability decreases and the consolidation time becomes longer than expected in the design. Although the size of the smear zone is a very important factor directly influencing the degree of consolidation, in the existing studies, the general value for the size of the smear zone proposed has been used in the design. However, the size of the smear zone proposed by the existing studies cause a loss of economical efficiency because of the inaccuracy of the design. Hence, in this study, the characteristics on the size of the smear zone were analyzed by carrying out the three dimensional numerical analysis and the method to determine the conversion size of the smear zone considering the change of the coefficient of permeability was proposed in order to consider the change of the coefficient of permeability in the actual design.

  • PDF

Flyback switching loss analysis by capacitor charge and energy conservation

  • Jin, ChengHao;Chung, Bong-Geun;Moon, SangCheol;Koo, Gwan-Bon
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.179-180
    • /
    • 2015
  • The task of measuring losses becomes more challenging with ever increasing efficiencies and operating frequencies in power electronics applications. Generally, the process of traditional switching loss calculation in flyback converter is very complicated. MOSFET drain-source voltage and current waveforms are needed to calculate switching loss. However, as we know in switched capacitor converter, switching loss can be easily calculated by charge and energy conservation law with known initial and final capacitor voltages. In this paper, the same method is applied to fly-back converter switching loss analysis to simplify calculation procedure.

  • PDF

Applicability Analysis of Head Loss Coefficients at Surcharge Manholes for Inundation Analysis in Urban Area (도시침수해석을 위한 과부하 맨홀의 손실계수 적용성 분석)

  • Kim, Chae Rin;Kim, Jung Soo;Yoon, Sei Eui
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.395-406
    • /
    • 2018
  • The XP-SWMM model, widely used for inundation analysis of urban watersheds, underestimated the inundation area (range) because the manhole was regarded as a node and the influence of the local loss occurring in the surcharged manhole can not be considered. Therefore, it is necessary to analyze the applicability of the head loss coefficients considering the local loss in the surcharged manholes in inundation analysis using XP-SWMM. The Dorim 1 drainage section of the Dorim-river watershed, where frequent domestic flood damage occurred, was selected as the study watershed. The head loss coefficients of the surcharged manholes estimated from the previous experimental studies were applied to the inundation analysis, and the changes of the inundation area with and without the application of the head loss coefficients with manhole types were compared and analyzed. As a result of inundation simulation with the application of head loss coefficients, the matching rates were increased by 17% in comparison with the without application of them. In addition, the simulated inundation area applied only the head loss coefficients of straight path manholes and applied up to the head loss coefficients of combining manholes ($90^{\circ}$ bend, 3-way, and 4-way) were similar. Therefore, in order to accurately simulate the storm drain system in urban areas, it could be to carry out two-dimensional inundation analysis considering the head loss coefficients at the surcharged manholes. It was expected that the study results will be utilized as basic data for establishing the identification of the inundation risk area.

A Study on the Development of Grating Structure for Drain of Water (도로 배수용 그레이팅 구조의 개선에 관한 연구)

  • Kim Key-Sun;Lee Eun-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.531-538
    • /
    • 2006
  • Grating is an installed structure on the road for drain. This paper proposes a new product which can prevent the accumulation of earth and sand through the improvement of Grating structure. There were usually harmful insects and bad smell because of accumulated garbage in the frame of previous product. The product had a reverse-flowing sewage due to the bad draining in case of rain. The whole thing of the existing Grating installed with the one set of frame and main body should be changed when it was damaged. This study is to develop a structure which can separate grating main body from frame and grating main body can equip and separate after fixing frame to the manhole with cement. also install jig for the loss prevention and change for the better.

  • PDF

Flow characteristics validation around drain hole of fan module in refrigerator (냉장고 팬 모듈의 물빠짐 구멍 주변 유동 특성 검증)

  • Jinxing, Fan;Suhwan, Lee;Heerim, Seo;Dongwoo, Kim;Eunseop, Yeom
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.102-108
    • /
    • 2022
  • In the fan module of the intercooling refrigerator, a drain hole structure was designed for stable drainage of defrost water. However, the airflow passing through the drain hole can disturb flow features around the evaporator. Since this backflow leads to an increase in flow loss, the accurate experimental and numerical analyses are important to understand the flow characteristics around the fan module. Considering the complex geometry around the fan module, three different turbulence models (Standard k-ε model, SST k-ω model, Reynolds stress model) were used in computational fluid dynamics (CFD) analysis. According to the quantitative and qualitative comparison results, the Standard k-ε model was most suitable for the research object. High-accuracy results well match with the experiment result and overcome the limitation of the experiment setup. The method used in this study can be applied to a similar research object with an orifice outflow driven by a rotating blade.

A Transformer Feedback CMOS LNA for UWB Application

  • Jeon, Ji Yeon;Kim, Sang Gyun;Jung, Seung Hwan;Kim, In Bok;Eo, Yun Seong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.754-759
    • /
    • 2016
  • A transformer feedback low-noise amplifier (LNA) is implemented in a standard $0.18{\mu}m$ CMOS process, which exploits drain-to-gate transformer feedback technique for wideband input matching and operates across entire 3~5 GHz ultra-wideband (UWB). The proposed LNA achieves power gain above 9.5 dB, input return loss less than 15.0 dB, and noise figure below 4.8 dB, while consuming 8.1 mW from a 1.8-V supply. To the authors' knowledge, drain-to-gate transformer feedback for wideband input matching cascode LNA is the first adopted technique for UWB application.

Design of Broadband FET Switch Using Drain Impedance Transformation Network (드레인 임피던스 변환회로를 이용한 광대역 FET 스위치 설계)

  • Choi, Won;No, Hee-Jung;Oh, Chung-Kyun;Koo, Kyung-Heon
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.60-63
    • /
    • 2003
  • This paper describes the design and the simulation of a V-band single pole double throw (SPDT) FET switch fur millimeter-wave applications using drain impedance transformation network with CPW transmission line. The designed switch has about 10% bandwidth at 60GHz. Insertion loss is better than 3dB fur the ON state and Isolation is larger than 30dB fer the OFF state. The maximum isolation is 43.4dB at 60GHz with input power of 10dBm. The yield analysis is done considering the effects of pHEMT variations.

  • PDF

Reverse annealing of boron doped polycrystalline silicon

  • Hong, Won-Eui;Ro, Jae-Sang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.140-140
    • /
    • 2010
  • Non-mass analyzed ion shower doping (ISD) technique with a bucket-type ion source or mass-analyzed ion implantation with a ribbon beam-type has been used for source/drain doping, for LDD (lightly-doped-drain) formation, and for channel doping in fabrication of low-temperature poly-Si thin-film transistors (LTPS-TFT's). We reported an abnormal activation behavior in boron doped poly-Si where reverse annealing, the loss of electrically active boron concentration, was found in the temperature ranges between $400^{\circ}C$ and $650^{\circ}C$ using isochronal furnace annealing. We also reported reverse annealing behavior of sequential lateral solidification (SLS) poly-Si using isothermal rapid thermal annealing (RTA). We report here the importance of implantation conditions on the dopant activation. Through-doping conditions with higher energies and doses were intentionally chosen to understand reverse annealing behavior. We observed that the implantation condition plays a critical role on dopant activation. We found a certain implantation condition with which the sheet resistance is not changed at all upon activation annealing.

  • PDF

Design and fabrication of SSPA module in Ku band for satellite terminals (Ku 대역 위성단말기용 SSPA 모듈 설계 및 제작)

  • Kim, Sun-il;Park, Sung-il
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.59-64
    • /
    • 2016
  • In this paper, a 10W GaN MMIC was designed and fabricated using the Ku-band SSPA module. For Design and fabrication of the SSPA module using Rogers(RO4003C) substrate was used for Branch-line structure. SSPA modules on budget Divider/Combiner was designed and fabricated less than the maximum insertion loss - 0.7dB. In addition, because it must be applied to the structural nature of GaN MMIC Gate Bias-Drain Bias circuit was implemented to apply the Gate-Drain sequential circuit, implemented the RF Power Detect, Temperature Detect, HPA On/Off function. Design and fabrication Ku-band SSPA Module got the measurement results that satisfy a maximum output of 15.6W, Gain 45.7dB, 19.0% efficiency.