• Title/Summary/Keyword: down sampling

Search Result 252, Processing Time 0.03 seconds

A study on water pollution of the physio-chemical conditions and phytoplankton of the Gumho River. (금호강의 이화학적 조건과 식물성 Plankton에 따른 수질오염에 관한 연구)

  • 강회양;차상은;박선섭
    • Journal of Environmental Health Sciences
    • /
    • v.8 no.1
    • /
    • pp.1-11
    • /
    • 1982
  • A study on the water pollution of Gumho river by the relationship between physio-chemical conditions and water quality level by phytoplankton was examined at 7 sampling positions during the period from Aug. 1 to Nov. 30, 1981. Examination of physio-chemicat water analysis such as temperature, pH, DO, BOD, and biological analysis are as follows: 1. pH was in the range of 6.6-7.3. 2. At all positions DO was0.5-11.9 mg/l. But at Shinchun bridge and Gangchang was 0.5-3.9 mg/l. 3. BOD was in the range of 3.4-29.2 mg/l. Banyawol, Dongchon and Gumdan was shown good condition. But at Shinchun bridge was 21.1-29.2 mg/l. 4. The plankton identification in this study period showed, Cyanophyceae is 7 genera 13 species, Bacillariophyceae is 11 genera 32 species, and Chlorophceae is 17 genera 27 species: total 35 genera 72 species. 5. In the point of phytoplankton classification, upper stream of Banyawol, Dongchon and Gumdan which BOD was 3.4-8.7 mg/l, dominant phytoplanktons were Synedra ulna, Ulothrix sp., Oscillatoria sp. and Frusturia rhomboides. At Shinchun bridge which BOD was 21.1-29.2 mg/l, Microcystis aeruginosa, Closterium acerosum and Oscillatoria sp were found a small. At 3rd gongdan which BOD was 9.2-12.5 mg/l, dominant species were Synedra ulna, Hormidium sp and Actinastrum hantzschii. At Paldal which BOD was 7.8-9.2 mg/l, dominant species were Nitzschia palea, Synedra ulna and Scenedesmus bijuga. At Gangchang of down stream which BOD was 6.9-9.2 mg/l, dominant phytoplanktons were Closterium acerosum, Microcystis aeruginosa and Actnastrum hantzschii. 6. The results of biological water analysis by saprobic system were as follows: Banyawol was from oligosaprobic to $\beta$-mesosaprobic, Dongchon and Gumdan was from $\beta$-mesosaprobic to $\beta$-mesosaprobic, Shinchun bridge was polysaprobic, 3rd gongdan was from $\alpha$-mesosaprobic to $\beta$-polysaprobic, Paldal was $\beta$-polysaprobic and Gangchang was $\alpha$-polysaprobic.

  • PDF

Mutual Authentication Protocol based on the Effective Divided Session for the Secure Transmission of Medical Information in u-Health (유헬스에서 안전한 생체정보전송을 위한 동적인 유효세션기반의 상호인증 프로토콜)

  • Lee, Byung-Mun;Lim, Heon-Cheol;Kang, Un-Ku
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.2
    • /
    • pp.142-151
    • /
    • 2011
  • All medical information over sensor networks need to transmit and process securely in the u-Health services. The reliability of transmission between u-Health medical sensor devices and gateway is very important issue. When the user moves to other place with u-Health devices, its signal strength is going down and is far from the coverage of gateway. In this case, Malicious user can be carried out an intrusion under the situation. And also rogue gateway can be tried to steal medical information. Therefore, it needs mutual authentication between sensor devices and gateway. In this paper, we design a mutual authentication protocol which divided sessions from an authenticated session are updated periodically. And in order to reduce the traffic overhead for session authentication, we also introduce dynamic session management according to sampling rate of medical sensor type. In order to verify this, we implemented the programs for the test-bed, and got an overall success from three types of experiment.

Compression-time Shortening Algorithm on JPEG2000 using Pre-Truncation Method (선자름 방법을 이용한 JPEG2000에서의 부호차 시간 단축 알고리즘)

  • 양낙민;정재호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.1C
    • /
    • pp.64-71
    • /
    • 2003
  • In this paper, we proposed an algorithm that shorten coding time maintaining image quality in JPEG2000, which is the standard, of still image compression. This method encodes only the bit plane selected as appropriate truncation point for output bitstream, obtained from estimation of frequency distribution for whole image. Wavelet characterized by multi-resolution has vertical, horizontal, and diagonal frequency components for each resolution. The frequency interrelation addressed above is maintained thorough whole level of resolution and represents the unique frequency characteristics for input image. Thus, using the frequency relation at highest level, we can pick the truncation point for the compression time decrease by estimating code bits at encoding each code block. Also, we reduced the encoding time using simply down sampling instead of low-pass filtering at low-levels which are not encoded in color component of lower energy than luminance component. From the proposed algorithm, we can reduce about 15~36% of encoding time maintaining PSNR 30$\pm$0.5㏈.

Efficient Localization of a Mobile Robot Using Spatial and Temporal Information from Passive RFID Environment (수동 RFID 환경에서의 공간/시간 정보를 이용한 이동로봇의 효율적 위치 추정 기법)

  • Kim, Sung-Bok;Lee, Sang-Hyup
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.164-172
    • /
    • 2008
  • This paper presents the efficient localization of a mobile robot traveling on the floor with tags installed, using the spatial and temporal information acquired from passive RFID environment. Compared to previous research, the proposed localization method can reduce the position estimation error and also cut down the initial cost tag installation cost. Basically, it is assumed that a mobile robot is traveling over a series of straight line segments, each at a certain constant velocity, and that the number of tags sensed by a mobile robot at each sampling instant is at most one. First, the velocity and position estimation of a mobile robot starting from a known position, which is valid for all segments except the first one. Second, for the first segment in which the starting position is unknown, the velocity and position estimation is made possible by enforcing a mobile robot to traverse at least two tags at a constant velocity with the steering angle unchanged. Third, through experiments using our passive RFID localization system, the validity and performance of the mobile robot localization proposed in this paper is demonstrated.

  • PDF

Fish Fuana in Southern River of Bukcheong and Brackish Lakes, the Shinpo District, North Korea (북한 신포지구내 북청 남대천과 기수호의 어류상)

  • Gil, Joon-Woo;Hong, Young-Pyo;Kim, Say-Wa
    • Korean Journal of Environmental Biology
    • /
    • v.25 no.3
    • /
    • pp.279-287
    • /
    • 2007
  • The purpose of the study was to introduce the fish fauna and distribution in the Shinpo district, North Korea. Sampling was carried out in October 1997, July 1998, May and October 2002, in sites located in the upstream, middle and down of the southern river of Bukcheong and three brackish lakes of Hommanpo, Daein and Hyunkum, respectively. A total of 29 species belonging to 11 families were found. Family Cyprinidae showed the prosperity in species number, comprising 28% among total species found. No natural monument fishes or rare fishes were captured. Ten commercial species, five anadromous ones and five brackish ones were identified. Feeding guilds was identified as 11 carnivores, 2 herbivores and 7 omnivores. Twenty species belonging to 7 families inhabited in the river, 18 species of 6 families in Lake Homanpo, 21 of 7 in Lake Hyunkum and 23 of 8 in Lake Daein, respectively. Ecological indices of richness, diversity and evenness were highest in Lake Daein and the dominace index was highest in Lake Hyunkum.

Identification of Red Tide-causing Organism and Characteristics of Red Tide Occurrence in the Oncheon Down Stream, Busan (온천천 하류 적조 원인생물의 동정 및 발생 특성)

  • Kim, Mi-hee;Ji, Hwa-seong;Cho, Jeong-goo;Cho, Sunja
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.3
    • /
    • pp.285-292
    • /
    • 2018
  • This study was performed in order to identify the red tide-causing organism and to understand the characteristics of the water quality during the winter of 2015 and 2016 in the Oncheon stream, a tidal river in Busan, where red tide often occurs in the wintertime. Two sites were selected on the stream and the surface water was sampled a total of 28 times during the experimental period. Twelve water quality characteristics, including water temperature, pH, DO, COD, total-N (T-N), total-P (T-P), and salinity were analyzed in order to test water quality. The cell numbers of cryptomonads were counted directly by microscopic observation. The nucleotide sequences of the partial 28S rRNA gene and psbA gene from metagenomic DNA, derived from each sampling site, were analyzed. According to the results, the alga most responsible for the bloom was identified as Teleaulax OC1 sp., which belongs to the cryptomonads. Three items of chl-a, pH, and DO were positively correlated with the cell numbers of the cryptomonads counted at the upper stream of the tidal area (St 1) while eight items of chl-a, TOC, BOD, total-N, COD, SS, pH, and DO were positively correlated with the cells located at the junction between the stream and Su-young river (St 2) in the order.

Spatial Interpretation of Monsoon Turbid-water Environment in a Reservoir (Yongdam) Discharging Surface Water, Korea (표층수를 방류하는 저수지(용담호)에서 몬순 탁수환경의 공간적 해석)

  • Shin, Jae-Ki;Hur, Jin;Lee, Heung-Soo;Park, Jae-Chung;Hwang, Soon-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.933-942
    • /
    • 2006
  • In this study, temperature, turbidity, suspended paniculate matter (SPM) distribution and mineral characteristics were investigated to explain spatial distribution of the turbid-water environment of Yongdam reservoir in July, 2005. Six stations were selected along a longitudinal axis of the reservoir and sampling was conducted in four depths of each station. Water temperature was showed the typical stratified structure by the effects of irradiance and inflow. Content of inorganic matter in suspended particles increased with the concentration of suspended particulate matter (SPM) due to the reduction of ash-free dry matter (AFDM). Turbidity ranged from 0.6 to 95.1 NTU and the maximum turbidity value of each station sharply increased toward downstream from upstream. The high turbidity layers were located at the depth between 12~16 m. Particle size ranged from 0.435 to $482.9{\mu}m$. day and silt-sized particles corresponded 91.9~98.9% and 1.1~8.0% in total numbers of SPM, respectively. Turbidity showed high correlations with clay (r=0.763, p<0.05) and silt content (r=0.870, p<0.05).Inorganic matter content (r=0.960, p<0.01) was more correlated with turbidity than organic matter (r=0.823, p<0.05). Mineral characterization using x-ray diffraction and electron probe microanalyzer demonstrated that the major minerals contained in the SPM were kaolinite, illite, vermiculite and smectite. As results of this study, surface water discharge as well as small size of the SPM were suggested as long-term interfering factors in settling down the turbid water in the reservoir.

A Study on Evaluation for the Han River Water Quality Index (한강의 수질지수 산정에 관한 연구)

  • 서정현
    • Water for future
    • /
    • v.14 no.3
    • /
    • pp.55-66
    • /
    • 1981
  • The theory and practice of water quality scoring and indexing are introduced. The monthly water analysis data are available for six stations long the down-stream Han River whthin the areal boundary of the Special City of Seoul. The data cover the period between 1975 and 1979 inclusive and contain the analytical findings on 37 water constituents including DO, BOD, temperature, total solids and etc. Sic parameters are selected form the 37 items, that, to the judgement of the writer, best reflect the water quality of the Han River. They are; dissolved oxggen saturation, pH, fecal coliform, total solids, BOD and nitrate+ammonia. For each of the six parameters, a subscore function is developed and graphically presented to facilitate the transform of a measurment of the arameter to a subscore on a common score(e.G. 0-100) The score of a sample is calculated as a fuction of the six subscores, using four different approaches; (1) the unweighted arithmetic water quality score, (2) the weighted arithmetic water quality score, (3)the unweighted multiplicative score and (4) the reduced (total) score. Independent of these calculated scores, the experts' score which is calculated by averaging the ratings of water quality experts is obtained and compared with each of the four calculated scores by means of the least square method. The experts' score compares most favorably with the "reduced" score with the correlation coefficient of 0.956 : therefore this method of water quality scoring is adopted to calculate the Han River water quality scores and indices. Water quality index data for Guiri, ukdo, Pokwangdong, Noryangjin, Yongdungpo and Kayang Stations, 1975-1979 are as follow: The overall water quality index data of the Han River between Guiri and Kayang Stations are found; 47.3 in 1976, 48.0 in 1977, 48.5 in 1978 and 54.7 in 1979, indicating the general trend towards water quality improvent in this part of the river, in terms of the increased water quality index by average 1.85 points per year during this period. Finally the optimum sampling frequencies distributed among the six stations, using an equation which takes into account the coefficients of variation of the water quality scores and indices arec calculated.alculated.

  • PDF

A Study on The Manufacturing Industries of Women's Wear in Taegu Through the Sewing Technicians (봉제기술자(縫製技術者)를 통해서 본 대구시(大邱市) 숙녀복업계(淑女服業界)의 현항(現況))

  • Kim,, Hyo-Eun;Kim, Soon-Boon
    • Journal of Fashion Business
    • /
    • v.2 no.4
    • /
    • pp.102-111
    • /
    • 1998
  • The purpose of this study is to present the basic material for the competitive, high-quality products by analyzing employees' attitude toward their job and some factors which influence the enhancement of productivity, education of workers, and facilities. This project was mainly conducted the conditions of women's wear manufacturing industries in Taegu by interviewing 143 employees in the sewing department. The result of this dissertation can be summarized as follows; 1. When it comes to the division of task in the sewing department, one team is composed of chairpersons (33.5%), assistant members (27.4%) and sub-assistant members (26.6%). The inspection of commodities as well as the enhancement of work on ironing for elaboration was divided as completion (12.6%) and finally the forms of task were made up of design sampling team (49%) and contracting team (51%). 2. Among the needle workers, as many as 60% employees had received technical education, which was by means of being passed down from the predecessors (81.6%). In terms of the period of education, from 2 to 5 years topped the list. The contents of education comprise patterning, sewing (65.2%) and ironing (20.3%). 3. The department of design takes charge of the report on working directions up to 88.2% and the working directions were used by 69.9 % of technicians. The directors of working conditions and methods were chiefs of designing department (37.7%) and those of sewing department (30.8%). The factors of defective goods were low-quality materials (50.0%), the deficiency in skills of workers. In terms of methods for preventing defects, technical education of workers, standardization of task and investment for factory automation were suggested. 4. As for their perception of present work, most of employees (80%) look upon it as a way of earning a living and 11% of them wanted to derive many things from their work. 59.2% of workers were satisfied with the product. When it comes to the incentive system provided by company, 67.0% responsed that it was not bad, and 23.9% evaluated it as 'satisfactory'.

  • PDF

A Research for Improvement of WIM System by Abnormal Driving Patterns Analysis (비정상 주행패턴 분석을 통한 WIM 시스템 개선 연구)

  • Park, Je-U;Kim, Young-Back;Chung, Kyung-Ho;Ahn, Kwang-Seon
    • Journal of Internet Computing and Services
    • /
    • v.11 no.4
    • /
    • pp.59-72
    • /
    • 2010
  • WIM(Weigh-In-Motion) is the system measuring the weight of the vehicle with a high-speed. In the existing WIM system, vehicle weight is measured based on the constant speed and the error ratio has 10%. However, because of measuring the driving pattern, that is abnormal driving pattern which is like the acceleration and down-shift of the drivers, it has the error ratio which is bigger than the real. In order to it reduces the error ratio of WIM system, the improved WIM system needs to find the abnormal driving pattern. In order to reducing the error ratio of these WIM systems, the improved WIM system can find abnormal driving patterns. In this paper, the improved WIM system which analyzes the abnormality driving pattern influencing on the error ratio of WIM system of an existing and minimizes the error span is designed. The improved WIM system has the multi step loop structure of adding the loop sensor to an existing system. In addition, the measure function defined as an intrinsic is improved and the weight measured by the abnormal driving pattern is amended. The analysis of experiment result improved WIM system can know the fact that the error span reduces by 8% less than in the existing the maximum average sampling error 22.98%.