• Title/Summary/Keyword: double plates

Search Result 164, Processing Time 0.018 seconds

The Results of Surgical Treatment of Comminuted Fractures of Distal humerus (원위 상완골 분쇄 골절의 수술적 치료 결과)

  • Cho Nam-Su;Park Sung-Woo;Jung Ki-Yoen;Rhee Yong-Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.2
    • /
    • pp.97-104
    • /
    • 2005
  • Purpose: To report the results of surgical treatment of comminuted fractures of distal humerus and to identify factors that affect the results. Materials and Methods: Thirty-two patients who were treated with open reduction and internal fixation for comminuted fracture of distal humerus were enrolled. According to the AO classification, A2.3 was 1 case, A3.2, 2 cases, A3.3, 8 cases, B1.3, 1 case, B2.3, 1 case, C2.2, 5 cases, C2.3, 4 cases, C3.2, 3 cases and C3.3, 7 cases. As fixation technique, 17 cases were fixed by double plates, 4 cases by only K-wires, 4 cases by only screws, 3 cases by K-wires and screws and 4 cases by one plate and screws. The mean age at the time of the operation was 49 years(range, $19{\sim}77$ years). The mean follow-up period was 16 months(range, $8{\sim}51$ months). Results: At the last follow-up, the mean maximum flexion was $116.4^{\circ}\;(range,\;85{\sim}140^{\circ})$ and the mean loss of terminal extension was $11.8^{\circ}\;(range,\;0{\sim}40^{\circ})$. The average Mayo elbow performance score was $91.4^{\circ}\;(range,\;55{\sim}100^{\circ})$. Overall 29 cases(91%) showed good to excellent results. The mean range of motion of extraarticular and intraarticular fracture group was $105.5^{\circ}\;(range,\;65{\sim}140^{\circ})$ and $104^{\circ}\;(range,\;55{\sim}140^{\circ})$, respectively. The average elbow score of both groups was$93^{\circ}\;(range,\;70{\sim}100^{\circ})$ and $90.7^{\circ}\;(range,\;55{\sim}100^{\circ})$. Over 90% showed more than good results. 30 cases(94%) showed complete bony union but two cases, nonunion. One case of the nonunion cases underwent replating with bone graft as revision surgery and total elbow arthroplasty was performed in the other case. At the last follow-up, 27 patients(84.4%) showed subjective satisfaction. Conclusion: Open reduction and internal fixation with appropriate surgical technique for comminuted fractures of distal humerus showed good results, which were not affected by age at the time of operation, fixation methods and anterior transposition of the ulnar nerve. Transolecranon approach may be considered as good choice for intraarticular comminuted fractures of distal humerus.

Application of Ordinary Kriging Interpolation Method for p-Adaptive Finite Element Analysis of 2-D Cracked Plates (2차원 균열판의 p-적응적 유한요소해석을 위한 정규크리깅 보간법의 적용)

  • Woo, Kwang-Sung;Jo, Jun-Hyung;Park, Mi-Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.4 s.74
    • /
    • pp.429-440
    • /
    • 2006
  • This paper comprises two specific objectives. The first is to examine the applicability of ordinary kriging interpolation(OK) to the p-adaptivity of the finite element method that is based on variogram modeling. The second objective Is to present the adaptive procedure by the hierarchical p-refinement in conjunction with a posteriori error estimator using the modified S.P.R. (superconvergent patch recovery) method. The ordinary kriging method that is one of weighted interpolation techniques is applied to obtain the estimated exact solution from the stress data at the Gauss points. The weight factor is determined by experimental and theoretical variograms for interpolation of stress data apart from the conventional interpolation methods that use an equal weight factor. In the p-refinement, the analytical domain has to be refined automatically to obtain an acceptable level of accuracy by increasing the p-level non-uniformly or selectively. To verify the performance of the modified S.P.R. method, the new error estimator based on limit value has been proposed. The validity of the proposed approach has been tested with the help of some benchmark problems of linear elastic fracture mechanics such as a centrally cracked panel, a single edged crack, and a double edged crack.

Current Status of the Synchrotron Small-Angle X-ray Scattering Station BL4C1 at the Pohang Accelerator Laboratory

  • Jorg Bolze;Kim, Jehan;Huang, Jung-Yun;Seungyu Rah;Youn, Hwa-Shik;Lee, Byeongdu;Shin, Tae-Joo;Moonhor Ree
    • Macromolecular Research
    • /
    • v.10 no.1
    • /
    • pp.2-12
    • /
    • 2002
  • The small-angle X-ray scattering (SAXS) beamline BL4C1 at the 2.5 GeV storage ring of the Pohang Accelerator Laboratory (PAL) has been in its first you of operation since August 2000. During this first stage it could meet the basic requirements of the rapidly growing domestic SAXS user community, which has been carrying out measurements mainly on various polymer systems. The X-ray source is a bending magnet which produces white radiation with a critical energy of 5.5 keV. A synthetic double multilayer monochromator selects quasi-monochromatic radiation with a bandwidth of ca. 1.5%. This relatively low degree of monochromatization is sufficient for most SAXS measurements and allows a considerably higher flux at the sample as compared to monochromators using single crystals. Higher harmonics from the monochromator are rejected by reflection from a flat mirror, and a slit system is installed for collimation. A charge-coupled device (CCD) system, two one-dimensional photodiode arrays (PDA) and imaging plates (IP) are available its detectors. The overall performance of the beamline optics and of the detector systems has been checked using various standard samples. While the CCD and PDA detectors are well-suited for diffraction measurements, they give unsatisfactory data from weakly scattering samples, due to their high intrinsic noise. By using the IP system smooth scattering curves could be obtained in a wide dynamic range. In the second stage, stating from August 2001, the beamline will be upgraded with additional slits, focusing optics and gas-filled proportional detectors.

A Study on Comparison Experiments for Judgement to the Nondestructive Analysis of Gold Plated Silverware Remains (비파괴분석법에 의한 은제금도금유물의 판단을 위한 비교실험 연구)

  • Sim, Myung-Bo;Yu, Hei-Sun;Kim, Soo-Ki
    • Journal of Conservation Science
    • /
    • v.27 no.1
    • /
    • pp.41-47
    • /
    • 2011
  • If the nondestructive analysis is carried out by using an X-ray Fluorescence Analyzer(XRF) for ingredient analysis with the target of gold plated silverware that plates gold on a silver basis, a singular point showing big difference at the value of weight percent(wt.%) according to the electron orbit of the principal ingredient can be confirmed. The present research made reproduced samples and carried out comparative analysis in order to suggest a basis that can judge whether the technique of gold plated silverware was used in case of remains uneasy to understand with eyes by using this singular point. As a result, the same result as analysis results of actual remains could be seen in specimens manufactured by a mercury amalgam plating method. However, in case of gold and silver alloy specimens, it could be confirmed that the difference according to the electron orbit of the principal ingredients is slight unlike plated specimens. The reason appearing at plated specimens seems to be generated while absorbing XRF beam at plated layers by double structure due to plating instead of single material. Accordingly, if this result appearing at nondestructive analysis is used, it was confirmed that the application of the technique of gold plated silverware can be judged without observing its section.