• Title/Summary/Keyword: double pipe

Search Result 172, Processing Time 0.02 seconds

Studies on Raw Silk Cohesion for Promotion (생사의 포합향상에 관한 연구)

  • 최병희;김병호;원성희
    • Journal of Sericultural and Entomological Science
    • /
    • v.15 no.1
    • /
    • pp.37-48
    • /
    • 1973
  • The purpose of this studies is to improve the cohesion of raw silk through various analyses on cocoon drying, cooking, reeling, re-reeling, and on the properties of water. Also we investigated the correlation between silk testing items which we have reached to the following results. 1. Drying of cocoon When cocoons were slowly dried with 100$^{\circ}C$, the results of cohesion became much better. On the other hand, the results were considerably decreased in case the temperature with 115$^{\circ}C$. 2. Cooking of cocoon In case of the cooking of cocoon, we found that the result of cohesion was best with incomplete cooking, that of the control was next, while in over cooking, the results were very low. Also the results of cohesion were much better when using the method of over cooking with sericin arrestive agent than that of incomplete cooking with sericin agglutinating agent. 3. Reeling of cocoon A) When the temperature of reeling bath was 25-45$^{\circ}C$, the results of cohesion test were much better, but at the temperature below 25$^{\circ}C$ or above 45$^{\circ}C$, the results became worse. B) With out the process of croissieur, the results of cohesion were too bad, but in case of croissieur more than 1cm, cohesion became better rapidly. Further more, we understood that the results of cohesion were improving slightly with longer length of croissieur. C) When the velocity of reeling was increased, the results of cohesion also improved. The best results were shown when reeling velocity was 180-220 r.p.m. But when the velocity was increased more than 220 r.p.m., the results of cohesion got worse more or less. D) When the temperature of the drying pipe in reeling machine was raised, the results of cohesion also showed a tendency to improve. 4. Re-reeling A) We could net reach a conclusion as to have correlation between the number of dipping repeat in vacuum tank and the results of cohesion before re-reeling process. B) When we used Seracol 500 as an agglutination protective agent with l/1000 to l/2000 of water, the results of cohesion test were better. C) When we used Pearl-lite as an agglutination protective agent with 1/1000 to 1/2000 of water, the results of cohesion were considerably better. D) We gained tile best results when used Cohesion Improving Chemical, A-80, with 500-1500 times diluted. 1) Results of cohesion was improved when humidity was low or temperature was high in the rereeling machine. 5. Filature water A) The water pH near the isoelectric point of protein showed the best cohesion, but the farther water pH, the worser results were obtained. B) With the increasing of M-alkalinity in filature water, the results of cohesion were worse. Above all, we understood the tendency of the results of cohesion get worse when the M-alkalinity is increased above 200 ppm. C) By increasing the total hardness of the filature water, it improved the results of cohesion. Especially, when the total hardness was above 300ppm, the results were extremely high. 6. Effects combination of each results A) The result of effects combination in filature processes with the obtained best conditions was distinctively improved. But the results could not reach in mathematicaly double effect. When reelied under worse conditions, the results of cohesion test were too bad. There was "effect limit" for the promotion. B) Generally the results of cohesion were bad when the filature conditions(the temperature, pressure and the properties of water, etc) are processed as sericin loss to be high. On the other hand, the results were very good when lower sericin loss was controlled in filature conditions. C) When filature conditions such as reeling velocity and croissieur length provide pysical cohesion ability and when raw silk dry fast during reeling and re-reeling, we found the result of cohesion was better. 7. Correlation of silk testing items. A) A negative correlation exists between the results of cohesion test and cleanness defect. Another word, the result of cohesion test was found to be worse as cleanness defect increased. B) In cleanness, cohesion has negative correlation against the number of slugs, but we could not find any correlation against long loops, loose ends. C) Cohesion has negative correlation against average neatness and low neatness defect. The better the results of neatness respectively, the better the results of cohesion found. D) There is no correlation between tenacity and the results of cohesion test, but there was high positive correlation between the results of elongation and those of cohesion test. The more elongation, the better the results of cohesion was found.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.