• Title/Summary/Keyword: double difference model

Search Result 107, Processing Time 0.023 seconds

A Study on Intention to live in Cohousing According to Housing Value (주거가치에 따른 코하우징 거주의사에 관한 연구)

  • Cho, Jeong-Hyun;Hong, Seo-Jung;Kwak, Yu-Mi;Kwak, In-Sook;Choi, Jung-Shin
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.123-130
    • /
    • 2006
  • This is a basic study to investigate possibility to application of cohousing model into Korea. Purpose of this study is to grasp respondents' housing value, and its influence on intention to live in cohousing. Research method used for this study was a social survey. Respondents were 214 married people residing in Seoul and its outskirts by accidential sampling. The collected data were analyzed by SPSS 12.0 program using frequency, mean, average, factor analysis, t-test, one-way ANOVA, Duncan's multiple range test, multiple regression and logit analysis. Result of this study was as follows. Housing values were classified into three categories named as individualism oriented housing value, tradition oriented housing value, and economy oriented housing value. Housing values were different by respondents groups. For example, individualism oriented housing value showed difference according to age and housing area. Tradition oriented housing value showed difference according to sex, occupation, and period of residence, while economy oriented housing value showed difference according to number of family members, housing type, and home ownership. In detail, men than women, single-income family than double-income family, and detached house resident than flat resident had higher tradition oriented housing value. The younger than the elder, and Seoul resident than outskirts resident had higher economy oriented housing value. Also home owner than tenant, and the higher tradition oriented group had stronger intention to live in cohousing than others.

  • PDF

A Study on Stress Concentration Factor of Composite Laminate Mechanical Joints (복합재료 적층판 기계적 체결부 응력집중계수에 대한 고찰)

  • Kwon, Jeong-Sik;Kim, Jin-Sung;Lee, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.194-200
    • /
    • 2013
  • In this paper, the results of composite laminate mechanical joints test(ASTM D5961) are compared with the theoretical strength calculations and FEM analysis results. To calculate the S.C.F.(stress concentration factor) on joint strength, equations on metallic and composite materials in ASM Handbook used and compared with experimental results. The difference of joint strength are compared by geometrical parameters and joining types(single/double lap joint). In FEM analysis, to find efficient FEM model on composite laminate mechanical joint, several FEM models are compared with experimental test results.

The effect of impact with adjacent structure on seismic behavior of base-isolated buildings with DCFP bearings

  • Bagheri, Morteza;Khoshnoudiana, Faramarz
    • Structural Engineering and Mechanics
    • /
    • v.51 no.2
    • /
    • pp.277-297
    • /
    • 2014
  • Since the isolation bearings undergo large displacements in base-isolated structures, impact with adjacent structures is inevitable. Therefore, in this investigation, the effect of impact on seismic response of isolated structures mounted on double concave friction pendulum (DCFP) bearings subjected to near field ground motions is considered. A non-linear viscoelastic model of collision is used to simulate structural pounding more accurately. 2-, 4- and 8-story base-isolated buildings adjacent to fixed-base structures are modeled and the coupled differential equations of motion related to these isolated systems are solved in the MATLAB environment using the SIMULINK toolbox. The variation of seismic responses such as base shear, displacement in the isolation system and superstructure (top floor) is computed to study the impact condition. Also, the effects of variation of system parameters: isolation period, superstructure period, size of seismic gap between two structures, radius of curvature of the sliding surface and friction coefficient of isolator are contemplated in this study. It is concluded that the normalized base shear, bearing and top floor displacement increase due to impact with adjacent structure. When the distance between two structures decreases, the base shear and displacement increase comparing to no impact condition. Besides, the increase in friction coefficient difference also causes the normalized base shear and displacement in isolation system and superstructure increase in comparison with bi-linear hysteretic behavior of base isolation system. Totally, the comparison of results indicates that the changes in values of friction coefficient have more significant effects on 2-story building than 4- and 8-story buildings.

A Numerical Study on Various Energy and Environmental System (II) (에너지${\cdot}$환경 제반 시스템에 관한 수치해석적 연구(II))

  • Jang D. S.;Park B. S.;Kim B. S.;Lee E. J.;Song W. Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1996.05a
    • /
    • pp.58-67
    • /
    • 1996
  • This paper describes some computational results of various energy and environmental systems using Patankar's SIMPLE method. The specific topics handled in this study are jet bubbling reactor for flue gas desulfurization, cyclone-type afterburner for incineration, 200m tall stack for 500 MW electric power generation, double skin and heat storage systems of building energy saving for the utilization of solar heating, finally turbulent combustion systems with liquid droplet or pulverized coal particle. A control-volume based finite-difference method with the power-law scheme is employed for discretization. The pressure-velocity coupling is resolved by the use of the revised version of SIMPLE, that is, SIMPLEC. Reynolds stresses are closed using the standard $k-{\varepsilon}$ and RNG $k-{\varepsilon}$ models. Two-phase turbulent combustion of liquid drop or pulverized coal particle is modeled using locally-homogeneous, gas-phase, eddy breakup model. However simple approximate models are incorporated for the modeling of the second phase slip and retardation of ignition without consideration of any detailed particle behavior. Some important results are presented and discussed in a brief note. Especially, in order to make uniform exit flow for the jet bubbling reactor, a well-designed structure of distributor is needed. Further, the aspect ratio in the double skin system appears to be one of important factors to give rise to the visible change of the induced air flow rate. The computational tool employed in this study, in general, appears as a viable method for the design of various engineering system of interest.

  • PDF

A Mathematical Modeling of Two-Dimensional Unsteady Flow for Long Waves in a Harbor (항내(港內) 장주기파(長週期波) 해석(解析)을 위한 2차원(二次元) 부정류(不定流)의 수학적(數學的) 모형(模型))

  • Lee, Jong Tae;Lee, Won Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.13-24
    • /
    • 1983
  • A mathematical model for the two-dimensional unsteady flow was developed by introducing Abbott's implicit finite difference operator and double sweep algorithm, which could be applied to simulate the respose of a harbor against the intrusion of long waves through the entrance connected to open sea. In order to improve its accuracy corresponding to the field phenomena, bottom resistance, Coriolis force, wind effect terms were included and wave direction and radiating effect was considered. The result of seiche test was always stable and the amplitude was accurate. Some phase shift was occured, but it could be reduced by using small values of Courant number and many points per a wave length as well. A comparision with the Ippen and Goda's theoritical and hydraulic experimental works was fulfilled.

  • PDF

A Comparative Analysys of Window Energy Performance According to the Difference Between Actual size and Standard size (창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석)

  • Kim, Seong-Beom;Lee, Su-Yeul;Kim, Dong-Yoon;Choi, Won-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.49-60
    • /
    • 2020
  • This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 ㎡. The analysis results were as follows. First, as the window glass's thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m × 1m window's thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m × 2 m window. Secondly, in the comparison of performance for increasing area with 2 m × 2 m and 3 m × 3 m windows, the 3 m × 3 m window's thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model's total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

Report on the Effects Lipemic Specimen in Anti-ds DNA Antibody Test (Anti-ds DNA 항체 검사 시 Lipemic 검체의 영향에 관한 보고)

  • Cheon, Jun Hong;Kim, Whe Jung;Kim, Sung Ho;Moon, Hyoung Ho;Yoo, Seon Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.153-157
    • /
    • 2014
  • Purpose: SLE (systemic lupus erythematosus) is an inflammatory autoimmune disease, characterized by various autoantibody. The detection of Anti double-stranded DNA (Anti-ds DNA) is important in the diagnostics of SLE, and include the American College of Rheumatology (ACR) diagnostic criteria for SLE. Also SLE disease activity and correlativity with the level Anti-ds DNA antibody have been reported and Anti-ds DNA antibody quantitative test is very useful for tracing before and after SLE treatment. When These Anti-ds DNA antibody test (Farr assay: $^{125}I$ labeled ds-DNA and bound Anti-ds DNA antibodies complex in serum is precipitated by ammonium sulfate and used to centrifugation, measured it) inhaled supernatant after centrifugation, a lipemic specimen does not facilitate the formation of precipitate and also occurs situation was inhaled with precipitate. To solve these problems, The Influence of the degree of lipemic specimen was evaluated. Materials and Methods: September 2012 to February 2013, We selected lipemic samples (n=81) of specimen commissioned by Anti-ds DNA antibody test. Lipemic samples were done pre-treatment (high-speed centrifugation: 14,000 rpm 5 mins) used a micro-centrifuge (Eppendorf Model 5415D). At the same time lipemic specimen and pre-treatment samples were performed Anti-ds DNA antibody test (Anti-ds DNA kit, Trinity Biotech, Ireland). Statistical analysis were analyzed Pearson's correlation coefficients and regression and paired t-test, and Difference (%). Results: Experimental group 1 (Lipemic Specimen Anti-ds DNA Ab concentration ${\leq}7IU/mL$) at y=0.368X+4.732, $R^2=0.023$, Pearson's correlation coefficient was 0.154, paired t-test (P=0.003), Difference (%) mean 65.7 and showed a statistically significant difference. Experimental group 2 (Lipemic Specimen Anti-ds DNA Ab concentration ${\geq}8IU/mL$) at y=0.983X+0.298, $R^2=0.994$, Pearson's correlation coefficient showed 0.997, paired t-test (P=0.181), Difference (%) mean -5.53 made no statistically significant difference. Conclusion: Lipemic sample of low Anti-ds DNA Ab concentration (2.5-7 IU/mL) and the result is obtained pre-treatment (high-speed centrifugation: 14,000 rpm 5 mins) were made a significant difference statistically. Anti-ds DNA is one of the primary auto-antibodies present in patients with SLE, and remain an important diagnostic test for SLE. Therefore, we recommend preprocessing (high-speed centrifugation: 14,000 rpm 5 mins) in order to exclude the influence of lipemic specimen.

  • PDF

A Study on the Energy Saving Methods of a House by Passive System (건축적 수법을 통한 주택의 에너지 절약 방안에 관한 연구)

  • 김용식
    • Journal of the Korean housing association
    • /
    • v.13 no.2
    • /
    • pp.73-78
    • /
    • 2002
  • Recently, the energy consumption has been sharply increased and the environmental pollution has been serious, resulted in increased use of fossil fuel. These facts are applied to most fields, and are especially important issues in the field of architecture. The energy consumption rate of building is about 30% of all energy consumption, and the rate of residential is about 20% of the rate of building and is increasing gradually. The purpose of this article is firstly to analyse an actual energy consumption rate of model building and compare it with alternative methods, which are applied passive system to, and secondly to suggest an optimal passive method for saving energy. The conclusion of this study is as follows; 1) As compared with the existing house on actual energy consumption rate, 6% in changing orientation to a south, 9% in using double low-e glazing and 23% in shading is decreased. 2) The change of insulation from 50 to 100mm did not show dramatical difference in energy consumption rate. 3) As changed indoor temperature at 2$0^{\circ}C$ in winter and 27$^{\circ}C$ in summer, the rate shows a reduction of 14% compared with the existing condition.

A Study on the Characteristics of Idle Vibration due to the Type of Constant Velocity Joints (등속조인트 방식에 따른 공회전 진동특성 연구)

  • Sa, Jong-Sung;Shin, Yang-Hyun;Kang, Tae-Won;Kim, Chan-Mook
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.183-190
    • /
    • 2008
  • This paper deals with the characteristics of idle vibration due to the type of constant velocity joints. Based on the kinematics model of constant velocity joints, a offset between the tripod center and tullip center plays a important role in generating unwelcome forces. Moreover, it induced additional forces in lateral direction of a vehicle movement according to the angle of the spider in idle vibration. The difference of mass for each constant velocity joint types affect the natural frequency of the driveshaft and the powertrain. When the static torque is applied to the constant velocity joints, the natural frequencies of the driveshaft are reduced nearby 50Hz. There will be a big opportunity that the dirveshaft and constant velocity joints would be a transfer path of idle vibration at D or R gear range. Experiments indicate that TJ type is better than SFJ and DOJ in idle vibration.

Numerical studies on cavitation behavior in impeller of centrifugal pump with different blade profiles

  • Song, Pengfei;Zhang, Yongxue;Xu, Cong;Zhou, Xin;Zhang, Jinya
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.2
    • /
    • pp.94-101
    • /
    • 2015
  • To investigate the influence of blade profiles on cavitation behavior in impeller of centrifugal pump, a centrifugal pump with five different blade profiles impellers are studied numerically. The impellers with five different blade profiles (single arc, double arcs, triple arcs, logarithmic spiral and linear-variable angle spiral) were designed by the in-house hydraulic design code using geometric parameters of IS 150-125-125 centrifugal pump. The experiments of the centrifugal pump have been conducted to verify numerical simulation model. The numerical results show that the blade profile lines has a weak effect on cavitation inception near blade inlet edge position, however it has the key effect on the development of sheet cavitation in impeller, and also influences the distribution of sheet cavitation in impeller channels. A slight changing of blade setting angle will induce significant difference of cavitation in impeller. The sharp changing of impeller blade setting angle causes obvious cavitation region separation near the impeller inlet close to blade suction surface and much more flow loss. The centrifugal pump with blade profile of setting angle gently changing (logarithmic spiral) has the super cavitation performance, which means smaller critical cavitation number and lower vapor cavity volume fraction at the same conditions.