• 제목/요약/키워드: double barrier discharge

검색결과 9건 처리시간 0.022초

이중베리어방전을 이용한 $NO_x$ 제거 ($NO_x$Removal by using Double Barrier Discharge)

  • 김동욱;정영식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권1호
    • /
    • pp.37-43
    • /
    • 2000
  • In this experimental study we proposed the double dielectric barrier discharge (DDBD) reactor to produce as high an electric field as possible. The experiment are conducted for applied voltage from 15 to 20[kV], $1~4[\ell/min]$ of gas flow rate and 120[Hz] and 240[Hz] of pulse rate. Superposition discharge(SPD) generated in DDBD which combined the surface discharge with the silence discharge was the most effective to reduce the $NO_x$. In the decomposition efficiency per watt, the low pulse rate gave better efficiency than the high pulse rate. However in DeNOx rate, the high pulse rate gave better performance than the low pulse rate. $NO_x$ removal rate and efficiency increased with increasing the applied voltage in all reactors.

  • PDF

공기/석영관(空氣/石英管) 복합유전체(複合誘電體)장벽층(障壁層)의 고주파(高周波) 펄스 방전(放電) 특성(特性) (Air/Quartz Dielectric Double Barrier Pulse Discharge)

  • 이응관;우정욱;정석환;이동훈;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1556-1558
    • /
    • 1994
  • An air/quartz dielectric double barrier pulse discharge has been investigated to develop a novel si lent type ozone generator. It is found that there are very active pulsed coronas occurred in the airgap which are very useful for ozone generation. And, the corona onset voltage of the airgap of the air/quartz double barrier was enfluenced greatly by the airgap of the air/quartz dielectric double barrier, and depended greatly upon the airgap ranged of $0.0{\sim}3.0mm$ and by the quartz tube thickness ranged of $1.75{\sim}2.25mm$.

  • PDF

펄스방전을 사용한 이중베리어방전 반응기에 있어서 NOx 제거에 관한 연구 (A study on NOx removal in double barrier discharge reactor using pulse power supply)

  • 김동욱;김응복;정영식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.169-172
    • /
    • 1999
  • In this experimental study we Proposed the double dielectric barrier discharge (DDBD) reactor to produce as high an electric field as possible. The experiment are conducted for applied voltage from 15 to 20[tV], flow gas rage at 2[1/min] and pulse rate at 120[pulses/s] and 240[pulses/s]. SPD connection of DDBD which combine the surface discharge with the silence discharge was most effective to reduce the NOx. In the decomposition efficiency per watt, the low pulse rate gave hotter efficiency than that of the high pulse rate. However in DeNOx rate, the high pulse rate gave better performance than that of the low pulse rate. NOx removal rate increased with increasing the applied voltage in all reactors.

  • PDF

운모박판(雲母薄板)/강유전체소구(强誘電體小球) 복합장벽방전(複合障壁放電)의 플라즈마발생특성 (Plasma Generation of Ferroelectric Ball/Mica Sheet Double Barrier Discharge)

  • 금상택;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1314-1316
    • /
    • 1995
  • Basic discharge characteristics of a ferroelectric ball and mica sheet double barrier have been studied for learning the fundamentals of the barrier discharges and for checking the potential to be used as a plasma generator. It is found that plasma generation of the plasma generator was influenced greatly by the dielectric constant of the ferroelectric ball barrier and applied power frequency. As a result, there are optimum conditions of the dielectric constant as a barrier and the applied frequency to generate ozone effectively, which were ${\varepsilon}_r$=600 and f=4 kHz at the present experimental case.

  • PDF

Study on Reactive Non-thermal Plasma Process combined with Metal Oxide Catalyst for Removal of Dilute Trichloroethylene

  • Han Sang-Bo;Oda Tetsuji;Park Jae-Youn;Park Sang-Hyun;Koh Hee-Seok
    • 한국전기전자재료학회논문지
    • /
    • 제19권3호
    • /
    • pp.292-300
    • /
    • 2006
  • In order to improve energy efficiency in the dilute trichloroethylene removal using the nonthermal plasma process, the barrier discharge treatment combined with manganese dioxide was experimentally studied. Reaction kinetics in this process was studied on the basis of final byproducts distribution. Decomposition efficiency was improved to about $99\;\%$ at the specific energy of 40 J/L with passing through manganese dioxide. C=C ${\pi}$ bond cleavage of TCE substances gave DCAC, which has the single bond of C-C through oxidation reaction during the barrier discharge plasma treatment. Those DCAC were broken easily in the subsequent catalytic reaction due to the weak bonding energy about $3{\sim}4\;eV$ compared with the double bonding energy in TCE molecules. Oxidation byproducts of DCAC and TCAA from TCE decomposition are generated from the barrier discharge plasma treatment and catalytic surface chemical reaction, respectively. Complete oxidation of TCE into COx is required to about 400 J/L, but $CO_2$ selectivity remains about $60\;\%$.

Reaction Kinetics and Dependence of Energy Efficiency in the Dilute Trichloroethylene Removal by Non-thermal Plasma Process combined with Manganese Dioxide

  • Han, Sang-Bo;Oda, Tetsuji;Park, Jae-Youn;Koh, Hee-Seok;Park, Sang-Hyun;Lee, Hyun-Woo
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.552-553
    • /
    • 2005
  • In order to improve energy efficiency in the dilute trichloroethylene removal using the nonthermal plasma process, the barrier discharge treatment combined with manganese dioxide was experimentally studied. Reaction kinetics in this process was studied on the basis of final byproducts distribution. Decomposition efficiency was improved to about 99% at the specific energy 40J/L with passing through manganese dioxide. C=C $\pi$ bond cleavage in TCE gave DCAC (single bond, C-C) through oxidation reaction during the barrier discharge plasma treatment. Those DCAC were broken easily in the subsequent catalytic reaction due to the weak bonding energy about 3 ~ 4 eV compared with the double bonding energy in TCE molecules. Oxidation byproducts of DCAC and TCAA from TCE decomposition are generated from the barrier discharge plasma treatment and catalytic surface chemical reaction, respectively. Complete oxidation of TCE into $CO_X$ is required to about 400J/L.

  • PDF

이중 베리어 방전 반응기를 사용한 $NO_x$ 제거에 관한 연구 (A Study on the Double Dielectric Barrier Discharge for $NO_x$ reduction)

  • 김동욱;김응복;정영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2182-2185
    • /
    • 1999
  • In this experimental study we propose the double dielectric barrier discharge(DDBD) reactor to produce as high an electric field as possible. DDBD reactor is designed to remove $NO_x$ at atmospheric pressures from the moving pollution source such as diesel automobile DDBD reactor consisted of two cylinder glass tubes arranged so that the gas flow was directed between the two tubes. Inside of the inner tube was filled with small metal beads and outside of the inner tube was wounded with stainless wire to form the electrode. The outer tube was surrounded by an aluminum foil In this reactor there are three electrodes, i.e. metal bead(C), helical wire(I) and aluminum foil(0). By using DDBD reactor we will report some interesting results of treatment of the gas which is the dilute mixtures of NO in N2. And then we compared thee results with the results of cylinder-wire(CW) which is one of popularly used reactor in non-thermal plasma applications.

  • PDF

경계면 수치 모델을 이용한 해안 지역 이중 양수정의 해수침투 저감 효과 (Effectiveness of Double Negative Barriers for Mitigation of Sewater Intrusion in Coastal Aquifer: Sharp-Interface Modeling Investigation)

  • 정은태;이성준;이미지;박남식
    • 한국수자원학회논문집
    • /
    • 제47권11호
    • /
    • pp.1087-1094
    • /
    • 2014
  • 해안지역에서 지하수 해수침투 저감을 위하여 해수 양수 관정을 가동할 때 해수정으로 많은 양의 담수가 낭비되는 사례가 있다. 해수 침투를 저감시키고 낭비되는 담수를 유용하게 활용하기 위하여 이중 양수정이 제안된 바 있다. 이중 양수정은 해수 양수를 위한 해안 쪽의 해수정과 담수 양수를 위한 내륙 쪽의 담수정으로 구성된다. 선행 연구에서는 담수정의 해수 비율을 최소화시키기 위한 해수정의 양수량을 산정하였으나 담수정의 해수비율이 1~15% 범위로 나타나 담수정에서 담수를 확보하기 어렵다고 판단하였다. 본 연구에서는 이송이 지배적인 상황에서 이중 양수정의 효과를 분석하였다. 연구 결과 담수정에서 저염도 지하수를 확보할 수 있음을 밝혔다. 또한 해안 유역 차원의 적정 지하수관리를 위해서는 담수정의 해수비율을 최소화하는 것 외에도 해수정으로 낭비되는 담수량을 최소화하는 것도 함께 고려해야한다.

플라즈마 공정을 이용한 고추역병균(Phytophthora capsici) 불활성화 모델의 적용 (Application of Inactivation Model on Phytophthora Blight Pathogen (Phytophthora capsici) using Plasma Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제24권11호
    • /
    • pp.1393-1404
    • /
    • 2015
  • Ten empirical disinfection models for the plasma process were used to find an optimum model. The variation of model parameters in each model according to the operating conditions (first voltage, second voltage, air flow rate, pH, incubation water concentration) were investigated in order to explain the disinfection model. In this experiment, the DBD (dielectric barrier discharge) plasma reactor was used to inactivate Phytophthora capsici which cause wilt in tomato plantation. Optimum disinfection models were chosen among ten models by the application of statistical SSE (sum of squared error), RMSE (root mean sum of squared error), $r^2$ values on the experimental data using the GInaFiT software in Microsoft Excel. The optimum models were shown as Log-linear+Tail model, Double Weibull model and Biphasic model. Three models were applied to the experimental data according to the variation of the operating conditions. In Log-linear+Tail model, $Log_{10}(N_o)$, $Log_{10}(N_{res})$ and $k_{max}$ values were examined. In Double Weibull model, $Log_{10}(N_o)$, $Log_{10}(N_{res})$, ${\alpha}$, ${\delta}_1$, ${\delta}_2$, p values were calculated and examined. In Biphasic model, $Log_{10}(N_o)$, f, $k_{max1}$ and $k_{max2}$ values were used. The appropriate model parameters for the calculation of optimum operating conditions were $k_{max}$, ${\alpha}$, $k_{max1}$ at each model, respectively.