• 제목/요약/키워드: dosimeters

검색결과 203건 처리시간 0.024초

Radiation Measurement of a Operational CANDU Reactor Fuel Handling Machine using Semiconductor Sensors (ICCAS 2003)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Yang-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1220-1224
    • /
    • 2003
  • In this paper, we measured the radiation dose of a fuel handling machine of the CANDU type Wolsong nuclear reactor directly during operation, in spite of the high radiation level. In this paper we will describe the sensor development, measurement techniques, and results of our study. For this study, we used specially developed semiconductor sensors and matching dosimetry techniques for the mixed radiation field. MOSFET dosimeters with a thin oxide, that are tuned to a high dose, were used to measure the ionizing radiation dose. Silicon diode dosimeters with an optimum area to thickness ratio were used for the radiation damage measurements. The sensors are able to distinguish neutrons from gamma/X-rays. To measure the radiation dose, electronic sensor modules were installed on two locations of the fuel handling machine. The measurements were performed throughout one reactor maintenance cycle. The resultant annual cumulative dose of gamma/X-rays on the two spots of the fuel handling machine were 18.47 Mrad and 76.50 Mrad, and those of the neutrons were 17.51 krad and 60.67 krad. The measured radiation level is high enough to degrade certain cable insulation materials that may result in electrical insulation failure.

  • PDF

방사선 검출기용 PET 박막의 에너지 의존성 (Energy Dependancy of the Polyethylene Terephthalate Film for Radiation Detector)

  • 백금문;김건중;김왕곤;홍진웅;이병용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.71-74
    • /
    • 2002
  • Currently small and accurate dosimeters are on the rise. In this study, the feasibility and energy dependency of the electret dosimeter that made of PET (polyethylene terephtalate) were observed by irradiating 4, 6, 15 MV photon beams from the clinical linear accelerator to develop a dosimeter for the clinical field. $10{\times}10cm$ field size of the photon beams were irradiated to the electret dosimeter where the 2.5 cm depth in the polystylene phantom from 100 cm SSD, while 300 DCV was applied to the electret dosimeter. The result showed that the absorbed dose was proportional to the charge linearly, and the volume of a dosimeter could be reduced and the signals were high enough. According to this study, it was found that the polymer electret detector could be produced as a large quantity with a small cost and showed the feasibility of a realtime measurement.

  • PDF

Novel polyvinyl alcohol film dosimeter containing 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide dye for high dose application

  • Khalid A. Rabaeh;Ahmed A. Basfar;Issra' M.E. Hammoudeh
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3383-3387
    • /
    • 2023
  • A new dyed polyvinyl alcohol (PVA) film dosimeter based on 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MMT) tetrazolium dye is proposed in this study for measuring high gamma radiation dose. Gamma cell irradiator that contains Co-60 gamma-ray source was used to expose the novel MMT-PVA films to different doses up to 25 kGy. The changed in optical property of irradiated and unirradiated films were characterized by UV-Vis spectrophotometer. The results show that the dose sensitive and the linear range of irradiated films were increased considerably with increase of MMT concentration from 1 to 5 mM. The dose response of dyed PVA film changed substantially with changing relative humidity (12-74%) as well as irradiation temperature (10-40 ℃). The absorbance of the unirradiated films does not change up to 10 days in dark while a significant increase in their absorbance was reported for similar films under fluorescent light. The irradiated dosimeters that kept in dark showed a perfect stability for 54 days. It was found that no obvious impact of dose rate on the irradiated MMT-PVA film dosimeters.

Development of a prototype TL/OSL reader for on-site use in a large-scale radiological accident

  • Hyoungtaek Kim;Chang-Young Park;Sang In Kim;Min Chae Kim;Jungil Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2113-2119
    • /
    • 2024
  • This study presents the development and characterization of a prototype TL/OSL reader for the retrospective dose assessment of individuals in radiological emergencies. The reader is portable, semi-automatic, and capable of accurate measurements. The dimension of the reader is 25 × 25 × 37 cm3 and the weight is about 15 kg. The reader consists of a sample moving stage, a heating module, an optical stimulation module, a detection module, a data acquisition (DAQ) unit, a nitrogen gas control module, and a PC with a GUI program. The reader has three measurement modes: TL, CW_OSL, and custom mode. The reader was characterized using commercial thermal luminescence dosimeters (TLD, LiF:Mg,Cu,Si) and optically stimulated dosimeters (OSLD, Al2O3:C), as well as fortuitous materials, such as display glasses and resistors of mobile phone. The results showed that the reader is capable of measuring signals with a detection limit of up to 0.02 mGy using a commercial dosimeter. In the dose recovery test using fortuitous materials, the reconstructed doses obtained three days post-irradiation closely aligned with the initially administered doses. As a result, this study suggests that the developed TL/OSL reader is a promising instrument for emergency dose assessment at accident sites.

영상의학과에서 사용되는 광자극 형광선량계와 전자식 개인선량계의 방향 의존성 비교 (The comparison of angular dependence for optical stimulated luminescence dosimeter(OSLD) and electronic personal dosimeter(EPD) used in Diagnostic Radiology)

  • 권순무;박정규;김부순
    • 디지털콘텐츠학회 논문지
    • /
    • 제16권3호
    • /
    • pp.463-470
    • /
    • 2015
  • 최근 개인선량계로 사용이 증가하고 있는 수동형 선량계인 OSLD와 능동형 선량계인 EPD의 상대 반응도(relative response), 측정 불확도(uncertainty of measurement)를 계산하여 방향의존성(angular dependence)을 비교, 분석하였다. OSLD는 수평, 수직방향의 $0^{\circ}{\sim}{\pm}90^{\circ}$ 범위에서 평균 상대 반응도는 0.97, 0.95의 작은 변화를 보였고 방향의존성에 대한 불확도는 0.65, 0.62로 전체 불확도에 미치는 영향은 미미한 것으로 판단되었다. EPD는 $0^{\circ}{\sim}{\pm}60^{\circ}$ 범위에서 수평, 수직방향 평균 상대 반응도는 0.94, 0.97로 확인되어 IEC 61526 규정을 만족하였다. 방향의존성에 대한 불확도는 수평, 수직방향에서 0.44, 0.40로 전체 불확도에 미치는 영향은 미미하였다. 그러나 수평방향에서 $+90^{\circ}$, $-90^{\circ}$ 방향의 상대 반응도는 0.60, 0.37이고 수직방향에서 $+90^{\circ}$ 방향의 반응도는 0.06으로 반응도의 큰 변화를 관찰할 수 있었다. OSLD의 방향 의존성은 $0^{\circ}{\sim}{\pm}90^{\circ}$ 범위까지 EPD에 비해 우수하였으며 EPD의 경우 구조적 특징으로 반응도가 급변하는 특정방향이 존재하였다. 따라서 수동형선량계와 보조선량계의 병행사용이 개인피폭선량측정의 정확도를 기할 수 있을 것으로 판단된다.

사고시 대응 정밀 베타선량계 개발 (Development of Precise Beta Dosimeter)

  • 이원근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.468-470
    • /
    • 1996
  • The use of thermoluminescent dosimeters (TLDs) for beta dosimetry has been encumbered by the energy-dependent responses of TLDs to beta radiation. This energy-dependent response is due to the low penetrating ability of beta particles. Thus the determination of the beta dose imparted to an exposed TLD chip can be accurately determined only if the energy distribution of beta radiation is correctly accounted for. So precise beta dosimeter used TLD chips place under several aluminum filters of varying thicknesses and developed to correctly determine doses due to radiation fields where the beta energy distribution is unknown.

  • PDF

국내 작업환경측정기관의 측정 및 분석장비 보유실태에 대한 고찰 (I) (Evaluation of the Possession of Measurement and Analytical Instruments among Domestic Work Environment Monitoring Service Providers (I))

  • 장재길
    • 한국산업보건학회지
    • /
    • 제23권3호
    • /
    • pp.250-260
    • /
    • 2013
  • Objectives: The aim of this study is to analyze the current status of the possession of measurement and analytical instruments among work environment monitoring organizations that have been designated by the Ministry of Employment and Labor (MoEL) in Korea. Methods: Data for measurement and analytical instruments were gathered by inspectors who had been assigned by the Korea Occupational Safety and Health Agency (KOSHA) and MoEL during the evaluation program for designated work environment monitoring service providers in 2012. Data for 11 monitoring instruments and nine analytical instruments were collected from 108 organizations. Basic data such as the type of service provides and the size of employment were also recorded by the inspector. Results: The total number of personal air samplers including high and low flow rates operated in Korea was 5,418, with average of 50.2. Average operation number of noise dosimeters was 35.0, while 3,780 dosimeters were used in 108 work environment monitoring organizations. There were 10,488 monitoring instruments in total. All service providers possessed at least one AAS and GC in their analytical laboratory. Total number of HPLC/MS was five, followed by ICP/MS of seven, with an average of 0.07. Conclusions: Based on the data, domestic work environment monitoring service providers possessed relatively reasonable measurement and analytical instruments. Nearly all instruments had been imported from advanced countries such as USA, UK and Japan. Periodic gathering of data on these instruments may help maintain good workplace monitoring results and the health of workers at the sites.

감마선 선량계를 개발하기 위한 상용 PIN 포토 다이오드의 응용 (Application of Commercial PIN Photodiodes to develope Gamma-Ray Dosimeters)

  • 정동화;김성덕
    • 센서학회지
    • /
    • 제9권4호
    • /
    • pp.274-280
    • /
    • 2000
  • 본 논문은 감마선 방사선 선량을 측정하기 위하여 상용 반도체를 응용하기 위한 실험적 연구에 대하여 다루었다. 실리콘 포토 다이오드는 값이 싸고 작으며 높은 효율과 견고하여 광검출기로 잘 이용되기 때문에 감마선과 같은 방사선 측정에 효과적으로 이용될 수 있다. 대부분의 PN 포토 다이오드는 이 증가함에 따라 역 방향 전류의 증가하는 특성을 가지고 있다. 그러므로 이 소자들의 공핍층이 역 방향 전류에 영향을 주므로 이 공핍층의 면적이 큰 PIN 포토 다이오드를 선택하였다. 이 연구에서는 방사선량을 검출하고 감마선 선량계를 개발하는데 적용하기 위하여, PIN 다이오드에 대해 몇 가지 실험이 수행되었다. NEC사의 PH 302와 SIEMENS사의 BPW 34와 같은 2가지 종류의 포토 다이오드를 반도체 분석장치를 사용하여 $\gamma$선 방사선원인 Co-60의 저준위 시설에서 시험하였다. 그 결과, 방사선 선량률과 다이오드의 전류 사이에 양호한 선형적 함수 관계가 나타나는 것을 확인할 수 있었다. 따라서, 이들 실리콘 PIN 포토 다이오드들은 $\gamma$선 선량계를 설계하는데 적합하게 이용될 수 있을 것이다.

  • PDF