• 제목/요약/키워드: dose linearity

검색결과 144건 처리시간 0.027초

Soluble Fiber Effect on Human Serum Leptin and Adiponectin: A Systematic Review and Dose-Response Meta-Analysis

  • Ali Zeinabi;Hadi Ghaedi;Seyed Ali Hosseini
    • Clinical Nutrition Research
    • /
    • 제12권4호
    • /
    • pp.320-335
    • /
    • 2023
  • Literature showed that soluble fiber has beneficial effects on cardiometabolic risk factors and leptin and adiponectin serum levels. Our aim in this meta-analysis was to determine the effect of soluble fiber supplementation on leptin and adiponectin serum levels. A systematic search was conducted using PubMed, Scopus, and ISI Web of Science for eligible trials up to December 2021. A random-effects model was used to pool calculated effect sizes. Our analysis showed that soluble fiber supplementation did not significantly affect adiponectin (standardized mean difference [SMD], -0.49 Hedges's, 95% confidence interval [CI], -1.20, 0.21, p value = 0.167; I2 = 95.4, p value < 0.001) and leptin (SMD, -0.8 Hedges's, 95% CI, -1.70, 0.08, p value = 0.076; I2 = 94.6, p value < 0.001) concentrations in comparison with placebo. However, in the subgroup, soluble fiber supplementation had a significant improvement in leptin concentration in overweight and obese patients (SMD, -0.22 Hedges's, 95% CI, -0.43, -0.01, p value = 0.048) and a non-significant beneficial effect in adiponectin level in female (SMD, 0.29 Hedges's, 95% CI, -0.13, 0.71, p value = 0.183) and diabetic patients (SMD, 0.32 Hedges's, 95% CI, -0.67, 1.32, p value = 0.526). A non-linear association between soluble fiber dosage and adiponectin (pnon-linearity < 0.001) was observed. Soluble fiber supplementation could not change the circulatory leptin and adiponectin levels. However, beneficial effects were seen in overweight and obese leptin, and increases in adiponectin may also be observed in female and diabetic patients. Further studies are needed to confirm this results.

고에너지 광자선속에서 TLD-100 chip 위에 있는 금박막(140 ${\mu}{\textrm}{m}$) 역할 (The Roles of Gold Plate (140${\mu}{\textrm}{m}$) Loaded on TLD-100 Chips in the High Energy Radiation Beams)

  • Vahc, Young-Woo;Park, Kyung Ran.
    • 한국의학물리학회지:의학물리
    • /
    • 제6권2호
    • /
    • pp.51-60
    • /
    • 1995
  • 고에너지 (6-15MV) 광자선속으로 치료할때 LiF(TLD-100) 결정은 solid water phantom 이나 환자의 피부 표면에서의 흡수선량을 측정하기 위해 열자극 발광 선량계(이하 NC-100)가 주로 사용된다. 통상 NC-100은 가열 과정을 여러회 반복하면 그 감도가 줄어드는 것으로 조사되었다. NC-100 위에 입사 광자선속 방향으로 올려놓은 140$\mu\textrm{m}$ 두께의 금박막(이하 GC-100)은 NC-100 과 다른 성질을 갖는다. 즉, 광자선속에서 GC-100 은 금박막에서 주로 쌍생성이 일어나고 부분적으로 Compton 산란이 일어나 많은 양전자와 음전자를 만들어 낸다. 그 결과 TLD-100 결정은 증가된 신호를 갖고(최대 100% 증가), 흡수 선량당 높은 반응도가 좋은 선형도를 갖으며, 선량물에 무관할 뿐만 아니라 Fluctuation error 도 $\pm$0.5% 미만으로 낮게 측정되었다. GC-100 은 주로 쌍생성이 일어나기 때문에 전자선보다 광자선에서 더욱 감도가 좋은것으로 나타난다. 그것은 금과같이 원자번호가 높은 매질에서 광자선에 의한 쌍생성의 확률이 큰것에 기인한다. 치료용 고에너지 광자선속에서 TLD-100 chip 위에 올려진 금박막은 TLD 의 신호를 크게 증가시키는 역할을 하는것으로 나타났다.

  • PDF

방사선 측정장치의 저준위 방사선 측정과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선에 관한 연구 (A Study On Low Radiation Measurement of Radiation Measuring Devices and Improvement of Reaction Speed according to the Rapid Change of Radiation Dose)

  • 이주현;이승호
    • 전기전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.544-551
    • /
    • 2014
  • 본 논문에서는 방사선 측정장치의 저준위 방사선 측정 알고리즘과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선을 위한 알고리즘 및 장치의 구성을 제안한다. 저준위 방사선 측정의 측정 정밀도를 개선하기 위한 알고리즘은 방사선 측정센서로부터 수집된 펄스의 누적평균을 기준으로 하는 듀얼 윈도우 방사선 수치 측정법을 사용한다. 방사선량의 급격한 변화에 따른 장치의 반응 속도개선을 위한 알고리즘은 신규로 입력된 6초 동안의 데이터 패턴분석을 통한 듀얼 윈도우 방사선 수치 측정법을 사용한다. 제안된 알고리즘의 검증을 위한 하드웨어 장치로는 센서 및 고전압 발생부, 제어부, 충전 및 전원회로부, 무선통신부, 디스플레이부 등으로 구성되어 있다. 제안된 알고리즘에서 사용한 듀얼 윈도우 방사선 수치 측정법을 실험한 결과, 기존 5uSv/h 수준의 저선량 한계에서 대체로 불확도가 낮아지고 선형성이 개선됨을 확인할 수 있었다. 또한 급격한 방사선량의 변화에 대한 장비의 반응속도 개선에 대해 실측실험을 통해 6초 이후에 변화된 수치가 반응함을 확인하였다. 따라서 제안된 알고리즘이 급격한 변화에 따른 장치의 반응속도가 개선됨을 확인할 수 있었다.

전자선 치료 분야의 선량 측정을 위한 반도체 화합물의 적용가능성 연구 (Study on the Applicability of Semiconductor Compounds for Dose Measurement in Electron Beam Treatment)

  • 양승우;한무재;신요한;정재훈;최윤선;조흥래;박성광
    • 한국방사선학회논문지
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2020
  • 본 연구에서는 전자선 치료에서 전자선 선량 측정 시 교차교정이 필요한 기존 평행평판형이온함을 대체하고자 하였다. 광도전성 반도체 화합물 HgI2를 사용하여 선량계로 제작하였으며, 선형가속기에서 6, 9, 12 MeV 전자선에 대한 HgI2 선량계의 특성을 분석하였다. 그리고 기존 선량계와의 대체가능성과 전자선 선량계로서의 적용 가능성을 평가하고 전자선 선량계 개발의 기초연구로써 활용하고자 하였다. 재현성 평가결과, RSD는 6, 9, 12 MeV 에너지에서 각각 0.4246%, 0.5054%, 0.8640%로 나타나 출력 신호가 안정적인 것을 나타내었다. 선형성 평가결과, 직선형 추세선의 신뢰도 지표 R2값은 6 MeV에서 0.9999, 9 MeV에서 0.9996, 12 MeV에서 0.9997로 나타나 선량이 증가함에 따라 HgI2에 출력 신호가 비례한 것을 확인할 수 있었다. 본 연구의 HgI2 선량계는 전자선 측정 적용가능성이 매우 높은 것으로 판단되며, 전자선 검출에 대한 기초연구로 활용될 수 있을 것으로 사료된다.

비파괴 검사 분야의 방사성 동위원소 위치추적을 위한 반도체 화합물의 적용 가능성 연구 (The Study on Applicability of Semi-conductive Compound for Radioactive Source Tracing Dosimeter in NDT Field)

  • 신요한;한무재;정재훈;김교태;허예지;이득희;조흥래;박성광
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.39-44
    • /
    • 2019
  • Co-60 및 Ir-192 등의 방사성 동위원소가 비파괴 검사(Non-Destructive Test; NDT) 등의 분야에서 널리 쓰임에 따라 방사선 안전관리가 매우 중요시되고 있다. 본 연구에서는 요오드화수은(Mercury(II) Iodide; $HgI_2$)의 선원추적 시스템 적용 가능성을 평가하였다. $HgI_2$로 제작된 Unit cell 센서의 신뢰도 검증을 위한 전기적 특성평가를 수행한 후, 방사선에 대한 센서의 위치의존성을 분석하고, Planning system의 선량 분포와 비교하였다. 평가결과, R-sq>0.99 이상의 선형성과 CV<0.015 이하의 재현성을 보이며 신뢰도가 높은 것으로 나타났다. 또한, 위치의존성 평가에서는 센서의 isocenter에서 최댓값이 측정되었으며, 거리에 따라 점진적 감소를 나타냈다. 그러나 Planning system 상의 선량 분포 데이터와는 최대 30%의 차이를 보였는데, 센서는 단일지점으로부터 데이터를 수집하는 Planning system과 달리 면적으로부터 수집하기 때문으로 사료된다.

Sleep Duration and Cancer Risk: a Systematic Review and Meta-analysis of Prospective Studies

  • Zhao, Hao;Yin, Jie-Yun;Yang, Wan-Shui;Qin, Qin;Li, Ting-Ting;Shi, Yun;Deng, Qin;Wei, Sheng;Liu, Li;Wang, Xin;Nie, Shao-Fa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7509-7515
    • /
    • 2013
  • To assess the risk of cancers associated with sleep duration using meta-analysis of published cohort studies, we performed a comprehensive search using PubMed, Embase and Web of Science through October 2013. We combined hazard ratios (HRs) from individual studies using meta-analysis approaches. A random effect dose-response analysis was used to evaluate the relationship between sleep duration and cancer risk. Subgroup analyses and sensitivity analyses were also performed. Publication bias was evaluated using Funnel plots and Begg's test. A total of 13 cohorts from 12 studies were included in this meta-analysis, which included 723, 337 participants with 15, 156 reported cancer outcomes during a follow-up period ranging from 7.5 to 22 years. The pooled adjusted HRs were 1.06 (95% CI: 0.92, 1.23; P for heterogeneity =0.003) for short sleep duration, 0.91 (95% CI: 0.78, 1.07; P for heterogeneity <0.0001) for long sleep duration. In subgroup analyses stratified by cancer type, long duration of sleep showed an inverse relation with hormone-related cancer (HR=0.79; 95% CI: 0.65, 0.97; P for heterogeneity =0.009) and a greater risk of colorectal cancer (HR=1.29; 95% CI: 1.09, 1.52; P for heterogeneity =0.346). Further meta-analysis on dose-response relationships showed that the relative risks of cancer were 1.00 (95% CI: 0.99, 1.01; P for linear trend=0.9151) for one hour of sleep increment per day, and 1.00 (95% CI: 0.98, 1.01; P for linear trend=0.7749) for one hour of sleep increment per night. No significant dose-response relationship between sleep duration and cancer was found on non-linearity testing (P=0.5053). Our meta-analysis suggests a positive association between long sleep duration and colorectal cancer, and an inverse association with incidence of hormone related cancers like those in the breast. Studies with larger sample size, longer follow-up times, more cancer types and detailed measure of sleep duration are warranted to confirm these results.

방사선사고시 피폭선량평가를 위한 휴대전화 부품의 전자상자성공명(EPR) 특성에 대한 예비 연구 (Preliminary Study on Electron Paramagnetic Resonance(EPR) Signal Properties of Mobile Phone Components for Dose Estimation in Radiation Accident)

  • 박병룡;하위호;박선후;이진경;이승숙
    • Journal of Radiation Protection and Research
    • /
    • 제40권4호
    • /
    • pp.194-201
    • /
    • 2015
  • 본 연구에서는 전자상자성공명(electron paramagnetic resonance, EPR) 장치를 사용한 휴대전화 부품들의 EPR 특성 측정을 통해 방사선사고시 회구적 선량평가용 선량계로써 활용가능성에 대하여 확인하였다. 화면표시 방식이 다른 두 스마트폰에서 12개의 시료를 선정하여 실험에 사용하였고, 시료의 방사선조사에는 $^{137}Cs$ 감마선 그리고 EPR 측정은 실온에서 Bruker사의 ELEXSYS E500 X-Band EPR spectrometer를 사용하여 수행하였다. 먼저 각 시료에 대하여 비조사시료와 조사시료의 EPR 스펙트럼을 측정하여 방사선에 의한 라디칼 생성 여부를 확인하였고, 그 후 선량반응곡선과 시간에 따른 시그널 크기 변화를 측정하였다. 측정결과 유심 플라스틱과 IC 칩을 제외한 모든 시료에서 방사선에 의한 EPR 시그널 증가를 확인할 수 있었다. 시료 중에서 덮개유리, 카메라렌즈, 도광판, 확산시트는 결정계수 $R^2=0.93$이상의 좋은 선형상관관계를 보였다. 특히 도광판은 선량에 따른 시그널 증가량이 가장 크고 백그라운드 시그널이 없기 때문에 선량평가에 이상적인 특성을 가지고 있었지만, 72 시간 이내에 시그널이 약 50% 감소하는 약점이 있었다. 확산시트 또한 도광판과 유사한 페이딩 특성을 나타내었고, 덮개유리와 카메라렌즈는 단기간 동안에는 시그널이 안정적으로 보존되었다. 휴대전화 부품을 이용한 EPR 선량평가를 실제 대규모 방사선 사고에서 신속하게 적용하기 위해서는 더 많은 휴대전화 기종의 같은 부품에 대한 시그널 차이, 페이딩, 시료 전처리 방법 등에 대한 추가연구가 진행될 필요가 있다. 그러나 현재 결과를 바탕으로 소규모 방사선사고시 피폭환자가 소지하고 있던 휴대전화와 동일한 제품을 구입하여 비교하는 방법 또는 추가조사법을 이용한 선량평가는 가능할 것으로 판단된다.

CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰 (A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT)

  • 방승재;김영연;정일선;김정수;김영곤
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.175-180
    • /
    • 2013
  • 목 적: 방사선치료에 있어 환자자세 설정(Set-up) 오차를 줄이기 위하여 많은 장비들이 개발되어 왔다. CBCT 촬영은 Set-up 오차를 줄이고, 정확한 치료를 수행하는 최신 방법 중 하나이다. CBCT의 조사야를 조절하여 영상의질(Image quality) 향상과 피폭선량을 측정하고 분석함으로써 임상에서 최적화하여 사용할 수 있는 치료조사야(Field size)를 제시하고자 한다. 대상 및 방법: Catphan phantom을 이용하여 Half fan, Full fan mode로 조사야를 2~16 cm까지 2 cm 간격으로 촬영하였다. Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (14 cm 이상)으로 구분하여 Image quality를 평가하였다. CTDi는 CTDi phantom과 Ion chamber를 이용하여 측정 및 분석하였다. 결 과: CT값 일치도(CT number linearity)는 Small, Large field size에서 촬영한 값이 Medium field size보다 크게 나타났다. 공간분해능(Spatial resolution)은 Full fan에서 Small field size촬영을 제외하고 나머지 Field size에서 크게 차이가 나지 않았다. Half fan에서는 많은 차이를 보였다. CT 값 균일도(HU uniformity)는 Full fan에서는 Medium size를 제외하고는 제조사에서 권고하는 값을 초과하였으며, Half fan에서는 모든 Field size가 Full fan에서는 Medium field size에서는 안정된 값으로 분석되었다. CT 피폭선량(CTDi)는 Medium field size에서 증가 할수록 루트함수의 그래프의 형태로 나타났다. 결 론:Small field size에서는 Image quality와 실용성의 측면에서도 적절하지 않은 것으로 사료된다. Medium field size는 Large field size에서 보다 Image quality도 우수하고 환자의 피폭선량을 줄일 수 있으므로 본 논문에서는 CBCT 촬영 시 Field size 8~10 cm 촬영이 유용하다고 사료된다.

  • PDF

고감도 형광판을 이용한 실시간 IMRT 선량 분석 가능성 연구

  • 고영은;이병용;안승도;이상욱;김종훈;신성수;최은경
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.36-36
    • /
    • 2003
  • 목적 : 고감도 형광판과 필름을 이용하여 실시간으로 선량을 측정하여 IMRT 선량분포를 검증하는데 사용하는 가능성을 알아보고자 하였다. 대상 및 방법 : 본 연구에서 개발한 물팬텀은 지름 25cm 아크릴 원통과 원통의 중앙부분에 삽입되는 고감도 형광판으로 구성되어 있다. 이를 사용하여 dose linearity correction factor를 구하기 위해 dmax 지점에서 6MV x-ray를 고감도형광판에 조사하여 blurring correction factor를 구하였다. CCD를 이용하여 고감도 형광판에서 나오는 영상을 수집하였다. 고감도 형광판에서 수집한 영상의 x축 profile은 RTP에서 얻은 profile과 비교하였고, 이온전리함으로 scanning한 데이터를 이용하여 고감도 형광판과 물에서 빛에 의한 산란선 때문에 발생하는 blurring effect를 교정하였다. 여기서 계산된 blurring effect factor를 고감도 형광판에서 수집된 영상에 적용하였다. 결과 : CCD 카메라는 형광판의 전 영역을 감지할 수 있고, 조사시간은 형광판의 중첩된 영상의 선량에 비례하였다. 물팬텀에서 형광판의 blurring effect 는 가우시안 분포로 표현할 수 있었다. 또한 Deconvolution kernel은 원통 팬텀에서 지름 $\pm$5cm 이내의 범위에 위치하였고, 따라서 형광판 영상으로부터의 실제 선량분 포를 뽑아낼 수 있었다. RTP 에서 계산된 선량분포와 blurring correction factor로 교정한 후 중첩시켜 얻은 고감도 형광판 영상의 선량분포는 일치하였다. 결론 : 정기적인 IMRT 선량 검증에 대한 실시간 선량측정 방법이 개발되었다. 고감도 형광판 영상과 CCD 카메라를 사용한 물팬텀으로, IMRT 치료계획에 대한 선량분포를 검증할 수 있는 가능성을 보였다.비의 회전에 의한 오차 보정, 필름의 광학적 밀도에 관한 보정 등 여러 가지 계통적 오차들에 대한 보정들이 선량분포 확인과정의 이해와 그 기준마련에 도움이 되겠지만 우리가 다룬 원점 불일치에 비해서 상대적으로 무시할 수 있었다. 마지막으로 선량분포 확인의 최종목표인 3 차원 선량분포 확인의 실제 적용을 위한 연구가 최적화 알고리듬을 이용하여 실험 중에 있다.\times$5cm, 10$\times$10cm, 15$\times$l5cm, 20$\times$20cm인 경우, 측정하여 얻은 PSF가 0.8%, 0.2%, 0.4%, 0.2%로 약간 높지만, 두 값은 매우 유사한 것으로 나타났다. 그리고, 기존의 BSF를 이용해 구한 TAR과 BJR 25에서 권고하는 PSF를 이용해 구한 TAR을 비교한 결과 field size 에 따라 약 1%-1.5% 정도로 BSF를 이용하여 구한 TAR보다 PSF를 이용하여 구한 TAR이 1.3% 정도 높게 나타났지만, 이것은 두 값의 절대적인 차이일 뿐, 실제로는 PSF를 이용하여 구한 TAR이 측정해서 구한 TAR과는 매우 유사한 값을 보여주고 있다. 결론 : 기존의 BSF를 이용해 구한 TAR과 PSF를 이용해 구한 TAR을 비교하였을 때, 약 1.3% 정도 높게 내고 있지만, 기존의 TAR보다는 PSF를 이용해 구한 TAR이 BJR 25와 잘 일치하고 있으므로 Co-60 원격치료용 방사선 조사장치를 사용할 경우 BSF보다는 PSF를 사용하는 것이 타당한 것으로 사료된다.tokines의 변화는 비록 통계학적인 차이는 없지만 비타민 C를 사용한 환자의 cytokines이 모두 사용하지 않은 환자에 비해 감소하였음을 보였다. 비타민 C는 부작용이 거의 없는 안전한 약으로서 말기 암 환자에서 비타민 C사용은 임상 증상을 호전시키는 데 도움

  • PDF

Analysis of Residual Triflumizole, an Imidazole Fungicide, in Apples, Pears and Cucumbers Using High Performance Liquid Chromatography

  • Khay, Sathya;EI-Aty, A.M. Abd;Choi, Jeong-Heui;Shim, Jae-Han
    • Toxicological Research
    • /
    • 제24권1호
    • /
    • pp.87-91
    • /
    • 2008
  • The present study was conducted to monitor the level of triflumizole residues in fruits (apple and pear) and vegetable (cucumber) samples in order to assess risk posed by the presence of such residues to the consumer. Triflumizole was applied at a recommended dose rate to apple and pear pulps and to a cucumber sample. The samples were collected at harvesting time following several treatments (three and/or four treatments). Triflumizole was extracted with methanol and re-extracted into dichloromethane. The presence of triflumizole was determined by HPLC with UV detection at 238 nm following the cleanup of the extract by open preparative chromatographic column with Florisil. The versatility of this method was evidenced by its excellent linearity (> 0.999) in the concentration range between 0.2 and 4.0 mg/kg. The mean recoveries evaluated from the untreated samples spiked at two different fortification levels. 0.1 and 0.4 mg/kg, and ranged from 87.5${\pm}$0.0 to 93.3${\pm}$2.6 for the tested fruits and vegetable, respectively, and the repeatability (as relative standard deviation) from three repetitive determinations of recoveries were no larger than 6%. The calculated limit of detection was 0.02 mg/kg and the minimum detectable level of 4 ng for triflumizole was easily detected. When triflumizole was sprayed onto the apple trees three times at 50-40-30 and 40-30-21 days prior to harvesting and four times onto the pear trees at 40-30-21-14 days prior to harvesting, the mean residual amounts of 0.05 and 0.06 mg/kg for apples and pears, respectively, were not detected in all of the treatments. When the cucumber sample was fumigated four times at 7, 5, 3 and 1 day prior to harvesting, the mean residual amount was not detectable. Triflumizole can be used safely when sprayed (wettable powder, 30% active ingredient) and fumigated (10%) 4 times at 14 and 1 day prior to harvesting to protect the fruits and vegetable, respectively.