• 제목/요약/키워드: dose intensity

검색결과 604건 처리시간 0.026초

Contrast-Enhanced Magnetic Resonance Angiography: Dose the Test Dose Bolus Represent the Main Dose Bolus Accurately?

  • Jongmin J. Lee;Yongmin Chang;Duk-Sik Kang
    • Korean Journal of Radiology
    • /
    • 제1권2호
    • /
    • pp.91-97
    • /
    • 2000
  • Objective: To determine whether the time-intensity curves acquired by test and main dose contrast injections for MR angiography are similar. Materials and Methods: In 11 patients, repeated contrast-enhanced 2D-turbo-FLASH scans with 1-sec interval were obtained. Both test and main dose timeintensity curves were acquired from the abdominal aorta, and the parameters of time-intensity curves for the test and main boluses were compared. The parameters used were arterial and venous enhancement times, arterial peak enhancement time, arteriovenous circulation time, enhancement duration and enhancement expansion ratio. Results: Between the main and test boluses, arterial and venous enhancement times and arteriovenous circulation time showed statistically significant correlation (p < 0.01), with correlation coefficients of 0.95, 0.92 and 0.98 respectively. Although the enhancement duration was definitely greater than infusion time, reasonable measurement of the end enhancement point in the main bolus was impossible. Conclusion: Only arterial and venous enhancement times and arteriovenous circulation time of the main bolus could be predicted from the test-bolus results. The use of these reliable parameters would lead to improvements in the scan timing method for MR angiography.

  • PDF

보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획 (Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters)

  • 추성실;이상욱;서창옥;김귀언
    • Radiation Oncology Journal
    • /
    • 제19권1호
    • /
    • pp.53-65
    • /
    • 2001
  • 목적 : 비인강암 환자의 국소제어율을 향상시키기 위한 목적으로 보상 여과판을 이용한 전방위 강도변조 방사선치료방법(intensity modulated radiation therapy : IMRT)을 계획하고 기존 3차원 입체조형치료방법과 비교하여 최적의 방사선치료방법을 모색하고자 한다. 대상 및 방법 : 3-차원 입체조형치료계획으로 치료받았던 비강암환자(T4N0M0) 1예를 선택하여 치료면의 굴곡과 뼈, 공동 등 불균질 조직으로 인하여 발생되는 표적체적의 선량분포를 균일하게 만들고 주변 정상장기의 손상을 최소화하기 위한 일차 입사선량의 강도 조절을 보상여과판으로 시행 하였다. 환자는 열변성 plastic mask로 고정시킨 후 치료조준용 CT Scan (PQ5000)을 이용하여 3 mm 간격으로 scan 하고 가상조준장치(virtual simulator)와 3차원 방사선치료계획 컴퓨터$(ADAC-Pinnacle^3)$를 이용하여 보상여과판을 제작하였다. 각 조사면을 세분한 소조사선(beamlet)의 강도 가중치(weighting)를 계산하고 가중치에 따른 선량 감약을 보상여과판의 두께로 환산하여 판별이 쉽도록 도표화하였다. 방사선 치료성과의 기준은 정량적으로 평가할 수 있는 선량체적표(dose volume histogram : DVH)와 종양억제확율(tumor control probability : TCP)및 정상조직 손상확율(normal tissue complication probability : NTCP)의 수학적 관계식을 이용하여 치료효과를 평가하였다. 결과 : 전방위 IMRT에서 계획용표적체적(planning target volume: PTV)내의 최소선량과 최대선량의 차이가 입체조형치료계획보다 약간 증가하였으며 평균선량은 강도조절치료계획에서 약 $10\%$, 더 높았고 전체 방사선량의 $95\%$가 포함되는 체적(V95)은 비교적 양쪽 설계방법에서 비슷한 양상을 보이고 있었다. 주위 건강장기들의 DVH에서 방사선에 민감한 장기인 시신경, 측두엽, 이하선, 뇌간, 척수, 측두하악골관절 등은 강도조절치료계획에서 많이 보호되었다. PTV의 종양제어확율은 입체조형치료계획과 강도변조치료계획에서 모두 비교적 균일하였으며 계획선량이 50 Gy에서 80 Gy로 증가함에 따라 TCP가 0.45에서 0.56으로 완만하게 증가하였다. 척수, 측두하악골 관절, 뇌간, 측두엽, 이하선, 시신경교차, 시신경 등 정상장기의 손상확율은 입체조형치료계획보다 강도조절치료계획에서 월등히 감소되었으며 특히 뇌간(brain stem)의 NTCP는 입체조형치료계획에서 보다 강도조절치료계획에서 훨씬 적은 값(0.3에서 0.15)으로 감소되었다. 계획선량의 증가에 따른 TCP와 NTCP를 입체조형치료계획과 강도조절치료계획에서 TCP는 공히 완만한 증가를 보였으나 NTCP값은 선량증가에 비례적으로 증가하였고 입체조형치료계획이 강도조절치료계획보다 월등히 증가하였다. 결론 : 보상여과판을 이용한 전방위 강도변조 방사선치료에서 PTV내의 선량 균일도의 개선은 없었지만 뇌간, 척수강 등 정상장기의 피폭을 줄일 수 있었다. 특히 인체표면의 굴곡이 심하거나 뼈, 동공 등으로 종양에 도달하는 방사선량분포가 균일하지 않을 경우 매우 유리한 치료방법이였다. 방사선치료성적을 평가함에 있어 DVH와 TCP, NTCP 등 수학적 척도를 이용함으로서 치료성과의 예측, 종양선량의 증가(dose escalation), 방사선수술의 지표 및 방사선치료의 질적 상황을 정량적 수치로 평가할 수 있어 방사선치료성과 향상에 기여할 수 있다고 생각한다.

  • PDF

전립선암의 세기조절 방사선 치료시 밀도보정의 효과 (The Impact of Tissue Inhomogeneity Corrections in the Treatment of Prostate Cancer with Intensity-Modulated Radiation Therapy)

  • 한영이;박원;허승재
    • 한국의학물리학회지:의학물리
    • /
    • 제15권3호
    • /
    • pp.149-155
    • /
    • 2004
  • 목적: 전립선암의 세기조절 방사선 치료 시, 조직의 밀도보정 여부가 선량분포에 끼치는 영향을 연구한다. 재료 및 방법: 5명의 전립선 암 환자에 대하여 6 MV와 10 MV의 광자선에 대하여 각각 치료계획을 수립하였다. 각각 의 계획에서 7개의 조사선이 설정되었고, 선량계산 시에는 체조직의 밀도의 불균일성을 무시하였다. 선량 처방점인 회전중심점에서의 흡수선량과 계획표적용적(PTV)의 최대선량, 최소선량, 평균선량과 처방점선량의 95% 이상의 받는 부피(V>$_{p95%}$) 등을 측정하였다. 직장과 방광 내에서의 최대선량, 최소선량, 최방선량의 50%, 75%, 90% 이상을 받는 부피를 측정하였다. 동일한 조건에서 조직의 밀도 불균일성을 포함하여 선량분포를 재계산하고, 측정한 모든 물리량을 재 측정하였다. 결과: 밀도보정을 함으로써, 처방점에서의 흡수 선량은 6 MV에서 평균 4.9% 10 MV에서는 평균 4% 감소하였다. V>$_{p95%}$는 6 MV와 10 MV에서 각각 0.8%와 0.9% 감소하였다. PTV의 평균 흡수 선량은 6 MV와 10 MV에서 각각 4.2% 와 3.4% 감소하였다. 직장과 방광에서의 흡수선량은 약 l~2%의 차이를 보였다 결론: 전립선암의 세기변조 방사선치료시에 밀도보정을 무시하는 것은 표적에는 고려할 만한 선량의 차이를 유발하며, 주위의 위험장기에 미치는 영향은 미미하다.

  • PDF

Brachytherapy: A Comprehensive Review

  • Lim, Young Kyung;Kim, Dohyeon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권2호
    • /
    • pp.25-39
    • /
    • 2021
  • Brachytherapy, along with external beam radiation therapy (EBRT), is an essential and effective radiation treatment process. In brachytherapy, in contrast to EBRT, the radiation source is radioisotopes. Because these isotopes can be positioned inside or near the tumor, it is possible to protect other organs around the tumor while delivering an extremely high-dose of treatment to the tumor. Brachytherapy has a long history of more than 100 years. In the early 1900s, the radioisotopes used for brachytherapy were only radium or radon isotopes extracted from nature. Over time, however, various radioisotopes have been artificially produced. As radioisotopes have high radioactivity and miniature size, the application of brachytherapy has expanded to high-dose-rate brachytherapy. Recently, advanced treatment techniques used in EBRT, such as image guidance and intensity modulation techniques, have been applied to brachytherapy. Three-dimensional images, such as ultrasound, computed tomography, magnetic resonance imaging, and positron emission tomography are used for accurate delineation of treatment targets and normal organs. Intensity-modulated brachytherapy is anticipated to be performed in the near future, and it is anticipated that the treatment outcomes of applicable cancers will be greatly improved by this treatment's excellent dose delivery characteristics.

Preliminary Study of Neuronal Response to Dose Distribution of Radiation with MR Spectroscopy

  • Ahn, Seung-Do;Yi, Byoung-Young;Lee, Jung-Hee
    • 한국생물물리학회:학술대회논문집
    • /
    • 한국생물물리학회 2002년도 제9회 학술 발표회 프로그램과 논문초록
    • /
    • pp.25-26
    • /
    • 2002
  • The goal of radiation therapy is to maximize the tumor dose and to minimize the dose of normal tissue. In order to achieve this goal, the new radiation therapy techniques such as three dimensional conformal therapy or intensity modulated radiation therapy has been developed and tried to clinical application. The relationship between radiation dose and normal tissue response is an interesting subject in the radiation therapy field.(omitted)

  • PDF

좌측 유방 방사선치료를 위한 역치료계획의 세기변조방사선치료와 다중빔조사영역치료기법 사이의 포괄적 선량측정 분석 (A Comprehensive Dosimetric Analysis of Inverse Planned Intensity Modulated Radiation Therapy and Multistatic Fields Technique for Left Breast Radiotherapy)

  • 문성권;윤선민
    • Radiation Oncology Journal
    • /
    • 제28권1호
    • /
    • pp.39-49
    • /
    • 2010
  • 목 적: 좌측 유방의 방사선치료에 있어, 3 빔 또는 5 빔을 이용한 세기변조방사선치료(intensity modulated radiation therapy, IMRT)와 다중빔조사영역 치료기법(multistatic fields techniques, MSF) 사이의 선량학적 차이를 분석하고자 하였다. 대상 및 방법: 개선된 선량 균일성을 만들 수 있는 가능성을 지닌 두 종류의 방사선치료 기술을 서로 비교 분석하였다. 첫째, 다중빔조사영역치료로 주조사야와 소조사야를 동시에 사용하여 치료하였다. 둘째, 고정된 다엽 조준기를 사용하는 IMRT로, 3 빔 또는 5 빔을 이용하였다. 유방보존술 후 방사선치료를 받은 16명의 초기 좌측 유방암 환자들을 대상으로 방사선치료계획들을 세운 다음, 이들을 선량학적 측면에서 비교 분석하였다. 결 과: $V_{95}$와 선량균일지수의 평균값은, 이 세 치료 사이에 통계학적으로 유의한 차이가 없었다. 방사선처방선량의 110% 이상을 받는 극심한 열점은 세 치료 모두에서 관찰되지 않았다. 동측 폐와 심장의 피폭 선량측정인자들에 대한 Tukey 검정에서, 세기변조방사선치료가 다중빔조사영역치료에 비해 저선량 영역의 피폭 선량을 유의하게 증가시킨 반면, 오히려 고선량 영역에서는 다중빔조사영역치료가 방사선 피폭을 약간 증가시켰다. 결 론: 선량 균일성 개선을 위해, 통상적인 쐐기기법 대신, 세기변조방사선치료보다 쉽게 계획되고 실시 될 수 있는 다중빔조사영역치료의 적용은 초기 좌측 유방암의 방사선치료 기술로 적합하다고 생각한다.

Encapsulated Silicon Nanocrystals Formed in Silica by Ion Beam Synthesis

  • Choi, Han-Woo;Woo, Hyung-Joo;Kim, Joon-Kon;Kim, Gi-Dong;Hong, Wan-Hong;Ji, Young-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권4호
    • /
    • pp.525-528
    • /
    • 2004
  • The photoluminescence (PL) emission of Si nanocrystals synthesized by 400 keV Si ion implanted in $SiO_2$ is studied as a function of ion dose and annealing time. The formation of nanocrystals at around 600 nm from the surface was confirmed by RBS and HRTEM, and the Si nanocrystals showed a wide and very intense PL emission at 700-900 nm. The intensity of this emission showed a typical behaviour with a fast transitory increase to reach a saturation with the annealing time, however, the red shift increased continuously because of the Ostwald ripening. The oversaturation of dose derived a decrease of PL intensity because of the diminishment of quantum confinement. A strong enhancement of PL intensity by H passivation was confirmed also, and the possible mechanism is discussed.

ESR Signal in Different Cuts of Irradiated Chicken, Pork and Beef

  • Nam, Hye-Seon;Yang, Jae-Seung;Ly, Sun-Yung
    • Nuclear Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.254-260
    • /
    • 2000
  • Electron spin resonance (ESR) spectroscopy was used to detect irradiated meat containing bones (chicken, pork and beef), to investigate the effect of irradiation dose on the ESR signal intensity and to identify the stability of radicals under 9 weeks of storage. Chicken, pork and beef were irradiated with doses 0, 1, 3, 5 and 7 kGy at room temperature using a Co-60 irradiator. Bones were pieced and dried, which were placed in a quartz tube within an Electron paramagnetic resonance (EPR) spectrometer resonator cavity. The irradiated bone presented an asymmetric absorption in shape, different from that of a non-irradiated one. The signal intensity of smaller animals are lower than larger species. Variation was observed between samples of the same species depending on the calcification status of the bone. Moreover different irradiation doses produced different signal areas that make possible to estimate the absorbed dose of treated meat. The ESR signal stability after irradiation was stable in even after a 9 week storage at room temperature.

  • PDF

세기변조 방사선치료의 환자 치료 전 선량보증에 대한 고찰 (Review on the Pre-treatment Quality Assurance for Intensity Modulated Radiation Therapy)

  • 한영이
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.213-219
    • /
    • 2013
  • 본 논문은 현재 세기변조 방사선 치료를 시행 시에 일반적으로 사용 되고 있는 환자 치료 전 품질보증의 방법 중, 2차원 선량분포를 측정하여 품질을 보증하는 방법들에 관한 이슈들을 최근 3~4년 간 발표된 논문들을 중심으로 살펴보고, 향후 품질보증 방법의 개선방향에 대하여 조명해 보고자 하였다.

유방암 접선조사에서 PBC 알고리즘과 AAA에 따른 Field-in-Field Intensity Modulated Radiation Therapy와 Conventional Radiation Therapy 전산화 치료계획에 대한 고찰 (Study on Computerized Treatment Plan of Field-in-Field Intensity Modulated Radiation Therapy and Conventional Radiation Therapy according to PBC Algorithm and AAA on Breast Cancer Tangential Beam)

  • 염미숙;배성수;김대섭;백금문
    • 대한방사선치료학회지
    • /
    • 제24권1호
    • /
    • pp.11-14
    • /
    • 2012
  • 목 적: Anisotropic Analytical Algorithm (AAA)는 Pencil Beam Convolution (PBC) 알고리즘에 비하여 2차선과 조직 불 균질에 대한 영향에 보다 더 정확한 선량계산을 제공한다. 본 연구는 유방암 접선조사 치료계획에서 PBC 알고리즘과 AAA의 선량계산 알고리즘에 따른 선량분포의 차이를 분석하고자 한다. 대상 및 방법: 선형가속기(CL-6EX, VARIAN, USA)의 6 MV 에너지를 이용한 유방암 환자 10명을 대상으로 Eclipse treatment planning system (Version 8.9, VARIAN, USA)을 사용하여 전산화 치료계획을 수립하였다. Conventional Radiation Therapy plan(Conventional plan)과 Field-in-Field Intensity Modulated Radiation Therapy plan (FiF plan)을 PBC 알고리즘을 이용하여 치료계획을 수립한 후 Monitor Unit (MU)를 고정시키고 AAA로 변경하여 선량계산하고, Dose Volume Histogram (DVH)을 이용하여 치료계획을 비교 분석하였다. 결 과: 첫 번째, Conventional plan의 PBC 알고리즘과 AAA에 따른 차이를 평가한 결과 치료용적에 대한 평균 Conformity Index (CI) 값의 차이는 PBC 알고리즘에서 0.295 높게 평가 되었다. 동측 폐에 대한 선량을 평가한 결과 $V_{47Gy}$$V_{45Gy}$는 PBC알고리즘에서 각각 5.83%, 4.04% 높게 평가되었고, Mean dose, $V_{20Gy}$, $V_{5Gy}$, $V_{3Gy}$는 AAA에서 각각 0.6%, 0.29%, 6.35%, 10.23%높게 평가되었다. 두 번째, FiF plan의 경우 치료용적에 대한 평균 CI 값의 차이는 PBC 알고리즘에서 0.165 높게 평가 되었고, 동측 폐에 대한 선량은 $V_{47Gy}$, $V_{45Gy}$, Mean dose는 PBC 알고리즘에서 각각 6.17%, 3.80%, 0.15% 높게 평가되었고, $V_{20Gy}$, $V_{5Gy}$, $V_{3Gy}$는 AAA에서 각각 0.14%, 4.07%, 4.35% 높게 평가되었다. 결 론: 유방암 접선조사에서 AAA로 계산했을 때, PBC 알고리즘에 비해 치료용적에 대한 Conformity가 Conventional plan, FiF plan 각각 0.295, 0.165 낮게 평가 되며, 동측 폐의 고 선량 영역의 선량은 적게 나타나며, 저 선량 영역의 선량은 많게 나타므로 폐에 대한 선량을 평가하는 데 선량계산 알고리즘에 따른 특징을 고려해야 할 것으로 사료된다.

  • PDF