• Title/Summary/Keyword: dose equivalent

Search Result 524, Processing Time 0.034 seconds

A study of dose and image quality with Convergence FFDM and DBT using tissue-equivalent phantom in digital mammography (유방조직등가 팬텀을 이용한 디지털유방촬영장치의 FFDM과 DBT의 선량과 영상품질에 대한 융합 연구)

  • Yoo, Young-Sin;Han, Dong-Kyoon
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.2
    • /
    • pp.29-34
    • /
    • 2019
  • In this study, we measure dose against various density and thickness using phantom to compare FFDM to DBT of Digital mammography equipment and evaluate usefulness of DBT through compare the image quality of FFDM and DBT. We use mammography equipment, Selenia Dimensions ; this is able to examine breast by both FFDM and DBT, The results are that when the thickness of phantom is 6cm or more and density is 70% or more and the thickness of phantom is 7cm or more and density is 50% or more, AGD of DBT is lower than that of FFDM. The evaluation results of image quality are that in the tumor and small calcification group that composed by mammary tissue and fat, FFDM is great and in fibrin, DBT is great. But in the all thicknesses of BR3D phantom that reflected overlapped tissue of breasts, DBT is great in calcification group, fibrin and tumor. DBT is greater image quality and lower dose more than FFDM in Thick and high density breast, Therefore, DBT is more useful in Korean women's breast that is characterized dense breast than FFDM.

Natural radioactivity level in fly ash samples and radiological hazard at the landfill area of the coal-fired power plant complex, Vietnam

  • Loan, Truong Thi Hong;Ba, Vu Ngoc;Thien, Bui Ngoc
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1431-1438
    • /
    • 2022
  • In this study, natural radioactivity concentrations and dosimetric values of fly ash samples were evaluated for the landfill area of the coal-fired power plant (CFPP) complex at Binh Thuan, Vietnam. The average activity concentrations of 238U, 226Ra, 232Th and 40K were 93, 77, 92 and 938 Bq kg-1, respectively. The average results for radon dose, indoor external, internal, and total effective dose equivalent (TEDE) were 5.27, 1.22, 0.16, and 6.65 mSv y-1, respectively. The average emanation fraction for fly ash were 0.028. The excess lifetime cancer risks (ELCR) were recorded as 20.30×10-3, 4.26×10-3, 0.62×10-3, and 25.61×10-3 for radon, indoor, outdoor exposures, and total ELCR, respectively. The results indicated that the cover of shielding materials above the landfill area significantly decreased the gamma radiation from the ash and slag in the ascending order: Zeolite < PVC < Soil < Concrete. Total dose of all radionuclides in the landfill site reached its peak at 19.8 years. The obtained data are useful for evaluation of radiation safety when fly ash is used for building material as well as the radiation risk and the overload of the landfill area from operation of these plants for population and workers.

Bolus Effect to Reduce Skin Dose of the Contralateral Breast During Breast Cancer Radiation Therapy (유방암 방사선치료 시 반대편 유방의 피부선량 감소를 위한 볼루스 효과)

  • Won, Young Jin;Kim, Jong Won;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.289-295
    • /
    • 2017
  • The aim of this study was to evaluate the dose comparison using Radon phantom with 5 mm and 10 mm tissue equivalent materials, FIF, Wedge(15, 30 angle) and IMRT, to reduce the skin dose of the contralateral breast during breast cancer radiation therapy(Total dose: 50.4Gy). The dose was measured for each treatment plan by attaching to the 8 point of the contralateral breast of the treated region using a optical-stimulated luminance dosimeter(OSLD) as a comparative dose evaluation method. Of the OSLD used in the study, 10 were used with reproducibility within 3%. As a result, the average reduction rates of 5 mm and 10 mm in the FIF treatment plan were 37.23 cGy and 41.77 cGy, respectively, and the average reduction rates in the treatment plan using Wedge $15^{\circ}$ were 70.69 cGy and 87.57 cGy, respectively. The IMRT showed a reduction of 67.37 cGy and 83.17 cGy, respectively. The results of using bolus showed that as the thickness of the bolus increased in all treatments, the dose reduction increased. We concluded that mastectomy as well as general radiotherapy for breast cancer would be very effective for patients who are more likely to be exposed to scattered radiation due to a more demanding or complex treatment plan.

Protective Effect of Astragalus polysaccharides on Liver Injury Induced by Several Different Chemotherapeutics in Mice

  • Liu, Wen;Gao, Fang-Fang;Li, Qun;Lv, Jia-Wei;Wang, Ying;Hu, Peng-Chao;Xiang, Qing-Ming;Wei, Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10413-10420
    • /
    • 2015
  • Side effects are an unavoidable consequence of chemotherapy drugs, during which liver injury often takes place. The current study was designed to investigate the protective effect of Astragalus polysaccharides (APS) against the hepatotoxicity induced by frequently-used chemical therapy agents, cyclophosphamide (CTX), docetaxel (DTX) and epirubicin (EPI)) in mice. Mice were divided into five groups, controls, low or high dose groups ($DTX_L$, $CTX_L$, $EPI_L$ or $DTX_H$, $CTX_H$, $EPI_H$), and low or high dose chemotherapeutics+APS groups ($DTX_L$+APS, $CTX_L$+APS, $EPI_L$+APS or $DTX_H$+APS, $CTX_H$+APS, $EPI_H$+APS). Controls were treated with equivalent normal saline for 28 days every other day; low or high dose group were intraperitoneal (i.p) injected with low or high doses of CTX, DTX and EPI for 28 days every other day; low or high dose chemotherapeutics+APS group were separately intraperitoneal (i.p) injected with chemotherapeutics for 28 days every other day and i.p with APS (100 mg/kg) for 7 days continually from the 22th to the 28th days. The body weight, serum levels of alanine aminotransferase (ALT) and aspartate aminotransferase (AST), histopathological features, and ultrastructure morphological change of liver tissues, protein expression level of caspase-3 were estimated at different time points. With high dose treatment of DTX, CTX and EPI, weight gain was inhibited and serum levels of ALT and AST were significantly increased. Sections of liver tissue showed massive hepatotoxicity in $CTX_H$ group compared to the control group, including hepatic lobule disorder, granular and vacuolar degeneration and necrosis in hepatic cells. These changes were confirmed at ultrastructural level, including obvious pyknosis, heterochromatin aggregation, nuclear membrane resolution, and chondrosome crystal decrease. Western blotting revealed that the protein levels of caspase-3 increased in $CTX_H$ group. The low dose groups exhibited trivial hepatotoxicity. More interestingly, after 100 mg/kg APS, liver injury was redecued not only regarding serum transaminase activities (low or high dose chemotherapeutics+APS group), but also from pathological and ultrastructural changes and the protein levels of caspase-3 ($CTX_H$+APS group). In conclusion, DTX, CTX and EPI induce liver damage in a dose dependent manner, whereas APS exerted protective effects.

Study on the Change of Absorbed Dose and Image Quality according to X-ray Condition of Detector in Digital Radiography(DR) (Digital Radiography(DR)에서 검출기의 X선 조건에 따른 흡수선량 및 영상화질 변화에 관한 연구)

  • Hwang, Jun-Ho;Jeong, Jae-Ho;Kim, Hyun-Soo;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.9
    • /
    • pp.99-106
    • /
    • 2017
  • This study focused on the issue that when a diagnostic detector is found to have a defect, a patient would be exposed to radiation and image quality would be degraded. Though dose analysis, an experiment was conducted to evaluate detector performance as Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR). Absorbed dose, SNR and CNR were measured using a dosimeter and a tissue equivalent phantom. The experiment was conducted to compare whether the dose value shown after being attached to the back side of the phantom matches the dose value attached behind the detector, where in the conditions of skull, chest and abdomen were set at 75 kVp, 25 mAs, 110 kVp, 8 mAs, and 80 kVp, 20 mAs, respectively. As a result, there was a difference in that the dose values attached to the back side of the detector were 0.004 mGy, 0.006 mGy, 0.003 mGy, whereas those of the back side of the phantom were 0.006 mGy, 0.016 mGy, 0.017 mGy. In order to match both values, the condition was increased and SNR and CNR also increased from 88.32, 88.10, 4.09, 1.63, 87.94, 79.97 to 93.87, 93.75, 4.91, 4.03, 92.02, 84.92. Though this study, we found that when a detector is found to have a aging, it shortens the life of equipment and increases the dose of a patient, also the improvement effect of image quality is inadequate.

Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography (복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향)

  • Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

Experimental Study on the Determination of Absorbed dose Index (흡수선량지수결정(吸收線量指數決定)에 관한 실험적(實驗的) 연구(硏究))

  • Jun, Jae-Shik;Rho, Chae-Shik;Ro, Seung-Gy;Ha, Chung-Woo;Yoo, Young-Soo;Lee, Hyun-Duk
    • Journal of Radiation Protection and Research
    • /
    • v.7 no.1
    • /
    • pp.34-48
    • /
    • 1982
  • The prime purpose of this study is to realize an index quantity, absorbed dose index, defined by the ICRU for the characterization of ambient radiation level at any location for the purpose of radiation protection. The experiment has been designed to be carried out in two phases, namely, preliminary and main experiment. In the primary study a 30cm diameter sphere of polyethylene was used, while in the main experiment that of tissue equivalent material was fabricated and used. Both experiments were performed in the gamma-ray fields of $^{137}Cs\;and\;^{60}Co$, and in a neutron beam of thermal column of the TRIGA MARK-II research reactor. In the measurement of gamma-ray absorbed dose TLD-700 $(^{7}LiF)$ chips were used, and for the neutron dose both Au activation foils and TLD chips (TLD-600 $(^{6}LiF)$ and TLD-700 for the discrimination of gamma-ray contribution) were used. Theoretical assessment of the absorbed dose in the sphere phantom has been carried out in accordance with the Ehrlich's idea that deduced on the basis of Burlin's cavity theory in the case of gamma-ray irradiation. For the analysis of neutron dose fluence-KERMA rate conversion method was used. The explanation on the dose assessment is given in detail. Results obtained were numerically and statistically analyzed and the depth dose distributions are presented in the graphic forms with normalized values. In the concluding remarks, the possibility and difficulty of realizing the index quantity, including questions and problems to be solved are mentioned.

  • PDF

Radiotherapic Valuation of Paraffin Wax for Patients with Oral Cancer (구강암 환자 치료시 치과용 기초상 왁스(Paraffin Wax)의 유용성 평가)

  • Na, Kyoung-Su;Seo, Seuk-Jin;Lee, Je-Hee;Yoo, Sook-Heun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • Purpose: This study is designed to investigate radiotherapic valuation of Paraffin Wax, which is newly formed for this study and generally utilized in dentistry, and Mouth Piece and Putty impression, which are commonly used in radiotherapy, for oral cavity as a compensator. Materials and Methods: Each compensator was formed by $10{\times}10{\times}1cm$ and measured radiation dose attenuation ratio with reference of water phantom which is made of tissue-equivalent materials. Two patients with oral cancer underwent DRR (Digitally Reconstructed Radiogrph) of Offline Review Program of Aria System and Portal vision for 5 times for each material to evaluate reproducibility by each filling materials. Moreover, MU (monitor unit) changes by dose absorption were considered in the case of inevitable implication of an filling materials in the range for radiotherapy. Results: Radiation dose attenuation ratios were shown -0.7~+3.7% for Mouth Piece, +0.21~+0.39% for Paraffin Wax and -2.71~-1.76% for Putty impression. Error ranges of reproducibility of positions were measured ${\pm}3mm$ for Mouth Piece, ${\pm}2mm$ for Paraffin Wax and ${\pm}2mm$ mm for Putty impression. Difference of prescription MU from dose absorption with an filling material increased +7.8% (250 MU) in Putty impression and -0.9% (230 MU) in Paraffin Wax as converted into a percentage from the standard phantom, Water 232 MU. Conclusion: Dose reduction of boundary between cavity and tissue was observed for Mouth Piece. Mouth Piece also had low reproducibility of positions as it had no reflection of anatomy of oral cavity even though it was a proper material to separate Maxilla and Mandible during therapy. On the other hand, Putty impression was a suitable material to correctly re-position oral cavity as before. However, it risked normal tissues getting unnecessary over irradiation and it caused radiation dose decrease by -2.5% for 1cm volume in comparison of it of water phantom. Dose reduction in Paraffin Wax, Fat Tissue-Equivalent Material, was smaller than other impressions and position reproducibility of it was remarkable as it was possible to make an anatomy reflected impression. It was also well fitted to oral cavity to transfer radiation dose planned in radiotherapy. Thus, Paraffin Wax will be an ideal material in radiotherapy for patients with oral cancer.

  • PDF

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

A study on AC over-current breaker using thyristor (Thyristor를 이용한 교류과전류 차단에 관한 연구)

  • 박민호;심재명
    • 전기의세계
    • /
    • v.28 no.7
    • /
    • pp.49-55
    • /
    • 1979
  • This paper describes the mechanisms which breaks A.C. over-current protection in low voltage load. For the high speed over-current protection, it consists of thyristor switching circuit by forced commutation, IC logic gate controlled circuit and over-current detector with reed switch. Under various duty conditions, breacker was carried out several experiments and discussions. The results are as follows; (1) over-current cut off is possible within a quarter cycle (4ms at 60Hz) and clear is at least ten times faster than its electromechanical equivalent. (2) as the forced commutation thyristor circuit breaker has capability of high speed break, equivalent surgy current capacity of switching thyristor is increased more than twenty times of its rated current. (3) breaker using solid state dose not produce any harmful arc during switching period. Therefore the breaker above described may be considered an effective over-current protector for soli state power devices in industrial applications.

  • PDF