• 제목/요약/키워드: dose equivalent

검색결과 524건 처리시간 0.03초

소음측정방법에 따른 평가소음도 비교 (A Comparison of Noise Level by Noise Measuring Methods)

  • 심철구;노재훈;박정균
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.128-136
    • /
    • 1995
  • The purpose of this study is to evaluate the difference of noise level according to noise measuring methods in the noisy working environments. Sound pressure level(SPL), equivalence sound level(Leq) and personal noise exposure dose(Dose) in the fifty-nine unit workplaces of the twenty-eight industries were measured and relating factors which were affected noise level were investigated. The results were as follows ; 1. The noise levels were $88.70{\pm}5.68dB(A)$ by SPL, $89.07{\pm}5.41dB(A)$ by Leq and $89.07{\pm}5.69$ by Dose. The differences of noise levels by three measuring methods were statistically significant(P<0.001) by repeated measure ANOV A. 2. Comparing with noise levels by general classes of noise exposure, noise levels of continuous noise were $89.14{\pm}5.19dB(A)$ by SPL, $89.45{\pm}4.65dB(A)$ by Leq and $90.04{\pm}5.09$ by Dose. Noise levels of intermittent noise were $87.90{\pm}6.52dB(A)$ by SPL, $88.40{\pm}6.63dB(A)$ by Leq and $90.10{\pm}6.80$ by Dose. The differences noise level of noise measuring methods by general classese of noise exposure were statistically not significant by repeated measure ANOV A. 3. Interaction between general classese of noise exposure and noise measuring methods for noise level was not statistically significant by repeated measure ANOVA. And the noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001) 4. Comparing with noise levels by unit workplace size, noise levels of large unit workplace were $90.73{\pm}5.87dB(A)$ by SPL, $91.32{\pm}5.50dB(A)$ by Leq and $91.82{\pm}6.06$ by Dose and noise levels of middle unit workplace were $88.31{\pm}5.26dB(A)$ by SPL, $88.41{\pm}4.83dB(A)$ by Leq and $89.69{\pm}5.05$ by Dose. And noise levels of small unit workplace were $94.89{\pm}4.10dB(A)$ by SPL, $85.35{\pm}4.11dB(A)$ by Leq and $86.87{\pm}4.98$ by Dose. The noise level differences of noise measuring methods by unit workplace size were statistically significant by repeated measure ANOV A(P<.05). 5. The noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001). But Interaction between workplace size and noise level measuring methods for noise level was not statistically significant by repeated measure ANOVA. According to the above results, there was a difference of the noise level among the three measuring methods. Therefore we must use the personal noise exposure dose using by noise dose meter, possible, to prvent occupational hearing loss in noisy working environment.

  • PDF

범용 실리콘 방사선 센서를 이용한 우주방사선 선량계 개발 (Developments of Space Radiation Dosimeter using Commercial Si Radiation Sensor)

  • 천종규;김성환
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.367-373
    • /
    • 2023
  • 비행시 승무원이나 승객은 우주방사선과 공기나 비행기 기체와 반응하여 발생한 2차 산란선 등에 의해 피폭을 받게 된다. 항공기 승무원의 경우 우주기상 환경 시뮬레이션을 이용하여 계산된 피폭선량으로 방사선 안전관리를 적용받고 있다. 하지만, 태양활동이나 고도, 비행경로 등에 따라 피폭선량이 가변적이어서 계산법보다는 항로별 측정하는 것이 권고되고 있다. 본 연구에서는 범용 Si 센서와 다중채널파고분석기를 이용하여 우주방사선 선량을 측정할 수 있는 선량계를 개발하였다. 선량계산은 미우주항공국의 우주방사선 측정장비인 CRaTER(Cosmic Ray Telescope for the Effects of Radiation)의 알고리즘을 적용하였다. 표준교정시설에서 Cs-137 662 keV 감마선으로 에너지 및 선량교정을 시행하였으며, 실험 범위에서 선량률 의존성이 없음을 확인하였다. 제작된 선량계를 이용하여 2023년 5월 두바이 인천 구간의 국제선에서 직접 선량을 측정한 결과 국내 우주방사선 선량평가코드(KREAM; Korean Radiation Exposure Assessment Model for Aviation Route Dose)로 계산된 결과와 12% 이내로 비슷하게 나타났으며, 고도와 위도가 높아짐에 따라 계산 결과와 동일하게 선량이 증가하는 것을 확인하였다. 좀 더 많은 실증적 검증 실험이 요구되는 제한점은 있지만, 항공기 내 또는 개인 피폭선량 모니터링에 가성비가 우수한 선량계로 충분한 활용 가능성을 확인하였다.

A New Index of the Bose Homogeneity for Treatment Planning

  • Yoon, Myong-Geun;Shin, Dong-Ho;Park, Sung-Yong;Lee, Se-Byeong;Kim, Tae-Hyun;Kim, Dae-Yong;Cho, Kwan-Ho
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2006년도 제33회 추계학술대회 발표논문집
    • /
    • pp.121-121
    • /
    • 2006
  • PDF

일부 동물성 한약재의 독성과 안전성등급화 - 봉독, 사독, 반묘와 오공을 중심으로 - (Toxicity and safety classification of 4 animal medicines - Focusing on venoms from bee, snake, blister beetle and scolopendrid -)

  • 박영철;이선동
    • 대한예방한의학회지
    • /
    • 제20권1호
    • /
    • pp.125-144
    • /
    • 2016
  • Objectives : About 13% of the medicines used by traditional korean medicines(TKM), are called animal medicines and are derived from non-herbal sources such as animals and insects. However, the clinical use of these preparations from animal medicines is often based on tradition and belief, rather than on evidence of toxicity and efficacy. As a result, animal medicines containing toxin have caused serious problems from injecting patients with venom. Here, various venoms frequently used as TKM were reviewed in terms of their instinct toxity and tried to estimate their safety classification. Methods : The estimation of safety classification was based on human equivalent dose(HED)-based MOS (margin of safety) and clinical dose applied for patients. Results and Conclusions : Except that of snake venom due to no clinical dose, they were evaluated as class 3 for bee venom, class 4 for cantharidin, toxin from blister beetle, and class 1 for venom from scolopendrid. In conclusion, animal medicines showed a wide range of safety classification from class 1 to class 4. This wide range is estimated to result from extremely limited applications of each venom for patients because of their strong toxicity. However, it should be cautious for application in clinics since animal medicines can produce anaphylactic reactions particularly after veinous administration even with a tiny amount of venom.

오존산화에 의한 정수장의 Microcystin제거 특성에 관한 연구 (A Study on the Removal Characteristics of Microcystin in the Water Treatement Plant by Ozonation)

  • 김민규;권재현;조영하;이진애;권오섭
    • 한국환경보건학회지
    • /
    • 제29권1호
    • /
    • pp.74-83
    • /
    • 2003
  • Microcystin, stable compounds with circular heptapeptides, is presented inside cyanobacterial cell. So far, over 30 types have been known to exist and microcystin-LR, RR among them are the most potent toxin compound. By this reason, a strong oxidant, ozone was used in this study to remove the microcystins produced by cyanobacteria. Removal efficiency of microcystin at M water treatment plant was also evaluated. Microcystin concentration was determined by protein phosphatase inhibition assay. The results showed that dissolved microcystin in raw water detected in the range of 0.011-0.028 ㎍ Microcystin-RR equivalent/l. Above 98% of microcystin was removed through overall treatment system. Therefore, the water treatability of M treatment plant seemed to be excellent. Removal efficiency of microcystin according to unit process varied as characteristics of raw water such as DOC, UV/sub 254/ and turbidity. Removal efficiency of microcystin by ozonation was investigated in laboratory according to contact time and ozone dose. Dissolved microcystin was increased by twice fold according to ozone contact time, but increased by fifth fold according to ozone dose. So, changing of ozone dose more affected microcystin release than changing of ozone contact time. Behavior of microcystin by ozonation was similar to that of DOC, and residual ozone concentration gave influence to removal ratio of microcystin. In conclusion, single ozone treatment wasn't effective on microcystin removal in case of water containing a lot of cells. Therefore, it's more effective to use ozonation process after the removal of cyanobacterial cells in advance.

ANALYSIS OF NECKING DEFORMATION AND FRACTURE CHARACTERISTICS OF IRRADIATED A533B RPV STEEL

  • Kim, Jin Weon;Byun, Thak Sang
    • Nuclear Engineering and Technology
    • /
    • 제44권8호
    • /
    • pp.953-960
    • /
    • 2012
  • This paper reports the irradiation effect on the deformation behavior and tensile fracture properties of A533B RPV steel. An inverse identification technique using iterative finite element (FE) simulation was used to determine those properties from tensile data for the A533B RPV steel irradiated at 65 to $100^{\circ}C$ and deformed at room temperature. FE simulation revealed that the plastic instability at yield followed by softening for higher doses was related to the occurrence of localized necking immediately after yielding. The strain-hardening rate in the equivalent true stress-true strain relationship was still positive during the necking deformation. The tensile fracture stress was less dependent on the irradiation dose, whereas the tensile fracture strain and fracture energy decreased with increasing dose level up to 0.1 dpa and then became saturated. However, the tensile fracture strain and fracture energy still remained high after high-dose irradiation, which is associated with a large amount of ductility during the necking deformation for irradiated A533B RPV steel.

고에너지 방사선으로 단일조사한 백서위의 병리조직학적 변화에 관한 연구 (The Pathological Changes of Stomach in Experimental Rats following Single Irradiation of Supervoltage)

  • 최명선;서원혁
    • Radiation Oncology Journal
    • /
    • 제2권1호
    • /
    • pp.25-32
    • /
    • 1984
  • The pathological changes of stomach of the rat following 1,000 rad and 1,800 rad single exposure by Cobalt-60 has been made with 50 experimental rats. The dose of 1,000 rad and 1,800 rad single exposure were equivalent of biologic effect of 2,500 rad in 2 1/2 weeks and 6,000 rad in 6 weeks. Following single exposure, the groups of rat were terminated in 1, 2, 4, 8, 12 weeks intervals and the stomach were fixed to formalin solution immediatly after dissection. The pathological changes were as follows : 1. Following 1,000 rad single exposure, the stomach show only mild to moderate submucosal edema in 4,8,12 weeks group. 1 and 2 weeks group show no changes. 2. Following 1,800 rad single exposure, $32\%(8/25)$ of rats were dead by radiation effect and all other groups of stomach revealed variable pathological changes such as submucosal edema, squamous dysplasia, squamous papilloma as well as squamous cell carcinoma. 3. Optimal tolerance dose to the stomach was $4,500\~5,000$rad when irradiation given by supervoltage. The entire stomach was included within the irradiation field, the dose to the stomach should not exceed 6,000 rad. 4. In conclusion, the radiation injury to the stomach were more direct radiation effects to the gastric mucosa rather than secondary changes of radiation injured vessels.

  • PDF

ML-6M LINAC에 장착한 Radiosurgery Cone의 Beam 특성에 대한 고찰 (Dose Characteristics of Stereotatic Radiosurgery CONE used for ML-6M Linear Accelerator)

  • 문언철;김현진;김영석
    • 대한방사선치료학회지
    • /
    • 제7권1호
    • /
    • pp.15-31
    • /
    • 1995
  • The radiosurgery treatment is one time, non surgical approach to the treatment of patients with intracranial disorders whose conditions would be difficult or dangerous to treat with conventional sugical procedures. The LINAC based radiosurgery is based on the combination of multiple isocentric arc irradiation with small fields centered in the stereotactic target. The absorption of the beam in a tissue equivalent medium, such as water, as well as the uniformity, or profile, of the beam must be precisely documented. The beam characteristics and dosimetric measurememts of the 6MV X-ray beam from a ML-6M linear accelerator are examined. The percent depth dose (PDD) and beam profile (including flatness, symmetry and penumbra) is calibrated with the radiosurgery cone in water phantom. The cone is made of lead which size is from $10{\times}10mm{\phi}$ to $30{\times}30mm{\phi}$ All of these dosimetric measurements sufficiently characterized the beam to permit safe clinical use.

  • PDF

장거리 여행용 버스에서의 멀미발생 예측에 관한 연구 (Study on the Motion Sickness Incidence in Express Buses)

  • 장한기;김승한;송치문;김성환;홍석인
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.234-240
    • /
    • 2003
  • This study aims to investigate dynamic properties of express buses in the very low frequencies which affect motion sickness incidence. Since passengers often use express buses for long distance traveling, it is a critical point whether a give rise to motion sickness or not. In the study accelerations at the three points on the floor of the six test vehicles were measured during the driving at constant speeds. By applying frequency weighting curves suggested in ISO 2631-1 and ISO 2631-3, physical amount of accelerations were changed into perceptual amount which determines incidence of motion sickness. Motion sickness dose values were calculated from the frequency weighted time history of accelerations, and compared between the vehicles, driving conditions, and the seat positions in the bus. During the driving on public road and high ways for 50 minutes vomiting incidence ratios ranged 0.4 to 0.8%, which were equivalent to 2.4 to 4.8% for 5 hours' driving. The value of 4.8 % means two among 45 passengers may vomit after the traveling, which is very serious situation. Considering the very smooth driving condition at which the data were collected, motion sickness dose values will increase in real situations

  • PDF

3D 프린트 소재에 따른 선량평가를 통한 볼루스 적용성 평가 (Evaluation of Bolus Applicability through Dose Evaluation According to 3D Print Materials)

  • 김정훈;이득희
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.241-246
    • /
    • 2019
  • 4차 산업혁명의 기술 중 3D 프린팅 기술의 소재에 따른 선량평가를 통해 볼루스 적용 가능성을 평가하였다. 선량의 평가는 몬테카를로 방식의 MCNPX프로그램을 이용하였으며, 3D 프린트 물성은 ABS, PC, PLA 세 가지로 하였다. 그리하여 볼루스 10 mm와 동일한 효과를 보이는 두께를 산정한 결과 6 MeV 전자선의 경우 ABS 10 mm, PC 9 mm, PLA 9 mm로 나타났다. 6 MV X-선의 경우 ABS 11 mm, PC 10 mm, PLA 9 mm로 나타났다. 본 실험을 통해 3D 프린터 소재로 제작하는 조직등가물질이 볼루스를 대체할 수 있음을 확인할 수 있었다.