  • This study carried out to understand thermoluminescence dating of ancient tiles at Jinju Janghungri Kilin site. Also radiocarbon dating by the benzene synthesis method and Liquid scintillation counting method were performed for comparison for the agedetermination of charcoal sample at the obtained same site.1st and 2nd glow curve were obtained according to the typical method thermoluminescence. Plateau tests of revealed the proper temperature range to be $300~440^{\circ}C$ Palaeodose average values were formed to the 2.44Gy.Annual dose of ancient tiles was calculated from soil samples and ancient tiles it self by measuring alpha radiation dose, potassium concentrations and water contents respectively. Annual dose average values were calculated to be 7.012mGy/yr.The radiocarbon age(BP year) was converted to calibrated age(AD/BC year) using high precision curve. Radiocarbon ages were calculated to be AD 15~17 .Comparison of samples with their radiocarbon and thermoluminescence ages for revealed the in range the AD 15~17. This result means that the measured absolute ages are in good agreement with each other within the margin of error.

  • PDF

Comparison of Linear Accelerator and Helical Tomotherapy Plans for Glioblastoma Multiforme Patients

  • Koca, Timur;Basaran, Hamit;Sezen, Duygu;Karaca, Sibel;Ors, Yasemin;Arslan, Deniz;Aydin, Aysen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권18호
    • /
    • pp.7811-7816
    • /
    • 2014
  • Background: Despite advances in radiotherapy, overall survival of glioblastoma multiforme (GBM) patients is still poor. Moreover dosimetrical analyses with these newer treatment methods are insufficient. The current study is aimed to compare intensity modulated radiation therapy (IMRT) linear accelerator (linac) and helical tomotherapy (HT) treatment plans for patients with prognostic aggressive brain tumors. Material and Methods: A total of 20 GBM patient plans were prospectively evaluated in both linac and HT planning systems. Plans are compared with respect to homogenity index, conformity index and organs at risk (OAR) sparing effects of the treatments. Results: Both treatment plans provided good results that can be applied to GBM patients but it was concluded that if the critical organs with relatively lower dose constraints are closer to the target region, HT for radiotherapeutical application could be preferred. Conclusion: Tomotherapy plans were superior to linear accelerator plans from the aspect of OAR sparing with slightly broader low dose ranges over the healthy tissues. In case a clinic has both of these IMRT systems, employment of HT is recommended based on the observed results and future re-irradiation strategies must be considered.

광자극발광선량계와 이온함을 이용한 두경부 원발종양 및 림프절 전이성 종양의 선량 측정: 산란판과 볼루스의 비교 (Measurement of Tumor Dose Using Optically Stimulated Luminescence Detectors (OSLDs) and Ionization Chambers for Primary and Metastatic Lymph Node Cancers with Head and Neck: Comparison of Beam Spoiler and Bolus)

  • 이정옥;이재승;정동혁
    • Journal of Radiation Protection and Research
    • /
    • 제36권3호
    • /
    • pp.160-167
    • /
    • 2011
  • 본 연구는 두경부 방사선치료에서 산란판(beam spoiler)과 볼루스(bolus)를 사용함에 따라 깊이가 다른 원발종양과 림프절 전이성 종양의 선량 변화를 이온함과 광자극발광선량계(optically stimulated luminescence detectors. OSLDs)를 이용하여 치료계획검증 방법으로 교차 비교하였다. 치료계획검증은 치료계획시스템에서 얻은 동일 조사 조건을 검출기가 삽입 가능한 고체 팬텀에 모사하는 방법으로 산란판과 0.5, 1 cm 볼루스를 비교하였으며 두 선량계의 교차비교는 측정 오차가 ${\pm}$2% 미만일 때 신뢰성이 있다고 판단하였다. 연구 결과 0.5 cm 두께의 산란판과 피부간 거리가 10 cm 일 때 최적의 선량분포를 얻을 수 있었으며 볼루스에 비하여 피부선량이 작고 중심부 원발종양 선량의 감소가 작았다. 또한 두 선량계의 교차 비교는 ${\pm}$1% 이내로 유의한 결과를 보였다. 두경부 종양의 방사선치료시 산란판을 사용함으로써 피부 부작용을 줄이면서 종양에 최적의 선량분포를 달성할 수 있다고 판단되었으며 향후 임상에 적용하기 위한 연구가 시행되어야 할 것이다.

두경부암의 근접방사선 치료 (Brachytherapy for Head and Neck Cancer)

  • 류성렬
    • 대한두경부종양학회지
    • /
    • 제7권1호
    • /
    • pp.3-9
    • /
    • 1991
  • Brachytherapy is a method of radiotherapy in advantage to achieve better local control with minimum radiation toxicity in comparison with external irradiation because radiation dose is distributed according to the inverse square low of gamma-ray emitted from the implanted sources. The main characteristics of brachytherapy are delivering of higher dose to target volume shortening of total treatment period and sparing of normal tissue. Recent development of iridium ribbons for low dose rate implant provides improvement of technology of brachytherapy in terms of safety and efficiency. High dose rate method. on the other hand, is effective to avoid unnecessary expoure of medical personnel.

  • PDF

Investigation of Dose Distribution in Mixed Neutron-Gamma Field of Boron Neutron Capture Therapy using N-Isopropylacrylamide Gel

  • Bavarnegin, Elham;Khalafi, Hossein;Sadremomtaz, Alireza;Kasesaz, Yaser;Khajeali, Azim
    • Nuclear Engineering and Technology
    • /
    • 제49권1호
    • /
    • pp.189-195
    • /
    • 2017
  • Gel dosimeters have unique advantages in comparison with other dosimeters. Until now, these gels have been used in different radiotherapy techniques as a reliable dosimetric tool. Because dose distribution measurement is an important factor for appropriate treatment planning in different radiotherapy techniques, in this study, we evaluated the ability of the N-isopropylacrylamide (NIPAM) polymer gel to record the dose distribution resulting from the mixed neutron-gamma field of boron neutron capture therapy (BNCT). In this regard, a head phantom containing NIPAM gel was irradiated using the Tehran Research Reactor BNCT beam line, and then by a magnetic resonance scanner. Eventually, the $R_2$ maps were obtained in different slices of the phantom by analyzing T2-weighted images. The results show that NIPAM gel has a suitable potential for recording three-dimensional dose distribution in mixed neutron-gamma field dosimetry.

Comparative Analysis of Cosmic Radiation Exposure Dose Due to the Russian Detour Route

  • Hee-Bok Ahn;Jaeyoung Kwak;Junga Hwang
    • Journal of Astronomy and Space Sciences
    • /
    • 제40권2호
    • /
    • pp.59-66
    • /
    • 2023
  • Since the World Health Organization (WHO) officially announced a global pandemic on March 12, 2020, the aviation industry in the world has been experiencing difficulties for a long time. Meanwhile, the Ukraine war broke out in February, and from March 15, domestic airlines must operate air routes bypassing Russian airspace despite the longer flight time. Therefore, as the flight time increases, the cosmic radiation exposure dose of the crew members is also expected to increase. Here we compare the radiation exposure dose between the route doses for the eastern United States and Europe before and after the detour route usage. Through the comparison analysis, we tried to understand how cosmic radiation changes depending on the flight time and the latitude and which one contributes more. We expect that this study can be used for the policy update for the safety management of cosmic radiation for aircrews in Korea.

비소세포폐암의 방사선 치료기법간의 선량분포의 비교 (Comparison of Dose Distribution between the Techniques of Non-small Cell Lung Cancer)

  • 이승철;김영재;장성주
    • 한국방사선학회논문지
    • /
    • 제10권4호
    • /
    • pp.233-239
    • /
    • 2016
  • 방사선 치료시 최근 많이 쓰이고 있는 IMRT, Tomotherapy, mArc(modulation arc therapy)의 치료법을 선량적인 측면에서 상호 비교하고자 한다. 비소세포성 폐암의 환자를 대상으로 하여 치료계획용적에 58.0 Gy를 처방선량을 기준으로 설정하였으며 주변 정상장기는 척수, 식도, 간을 설정 하였다. PTVmean는 mArc의 경우 57.60 Gy, Tomotherapy가 61.04 Gy, IMRT는 58.95 Gy이었다. 식도(Esophagus)의 평균선량은 mArc가 2.84 Gy였고, Tomotherapy가 5.14 Gy, IMRT가 1.84 Gy로 나타났다. 간(Liver)은 mArc는 19.44 Gy, Tomotherpy가 12.22 Gy, IMRT는 21.97 Gy이었고 척수(Spinal Cord)은 mArc 5.72 Gy, Tomotherapy가 7.08 Gy, IMRT는 6.15 Gy로 측정되었다. 또한, 선량포함도와 선량체적곡선 등의 자료를 관찰해 본 결과 mArc와 Tomotherapy 그리고 IMRT의 결과와 현저한 차이를 보이지는 않았다. 하지만, 본 연구는 폐암이라는 질환으로 한정하였었고 실험군의 수가 적은 단점을 가지고 있으므로 좀 더 많은 질환과 환자를 대상으로 연구를 폭넓게 진행 한다면 환자 맞춤형 치료기법을 개발하여 적용될 것으로 사료된다.

Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

  • Jeong, Dae-Kyo;Lee, Sang-Chul;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제42권2호
    • /
    • pp.65-70
    • /
    • 2012
  • Purpose : The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Materials and Methods : Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. Results : The effective dose was the highest for Somatom Sensation 10 (425.84 ${\mu}Sv$), followed by AZ3000CT (332.4 ${\mu}Sv$), Somatom Emotion 6 (199.38 ${\mu}Sv$), and 3D eXaM (111.6 ${\mu}Sv$); it was the lowest for Implagraphy (83.09 ${\mu}Sv$). The CBCT showed significant variation in dose level with different device. Conclusion : The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

Comparison of the Breast Dose based on the Existence of the Bismuth Breast Protection Shield for Automatic Exposure Control and Manual Exposure Control with the Coronary Artery CT Angiography

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • International Journal of Contents
    • /
    • 제7권4호
    • /
    • pp.103-107
    • /
    • 2011
  • The effective dose and the organ absorbed dose, which are given to a breast in the cases of using and not using the bismuth breast protection shield for the protection of a breast with the coronary artery CT angiography, have been measured and compared for the manual exposure control (MEC)and the automatic exposure control (AEC). In the cases of using and not using the bismuth breast protection shield, it has been found that the measured dose shows the reduction of about 23 to 26% for the MEC and about 22 to 25% for the AEC when the shield is used compared to the case of not using it. By comparing the shield and non-shield cases for the AEC and the MEC, it can be said that the value measured by carrying out the scanning process with the AEC mode has decreased by about 24 to 30% compared to the case of applying the MEC mode. Such a result shows that it is recommended to use the AEC mode for the reduction of the patient's exposure dose during the CT examination.

정류방식에 따른 장치의 정확도와 출력 파형의 비교 (Comparison of Accuracy and Output Waveform of Devices According to Rectification Method)

  • 이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.603-610
    • /
    • 2018
  • This study examined the following: accuracy of the exposure conditions in the inverter device and three-phase device; output waveform over the exposure conditions; and average and standard deviation of the output waveform. After assessing whether the dose corresponding to the theoretical dose was presented, the following conclusions were obtained: 1. The accuracy of the tube voltage(kVp) and tube current(mA) exposure time(sec) was within the tolerable level prescribed in Korea's Safety Management Standards. In the error, Inverter device was large the tube voltage and exposure time, the three-phase device was large the tube current. 2. In terms of the output waveform of the exposure conditions and the average and standard deviation of the output waveform, the higher tube voltage and larger tube current resulted in greater standard deviation in pulsation. Moreover, the standard deviation of pulsation was shown to be greater in the inverter device than the three-phase device; there was also greater standard deviation in the inverter device considering the exposure time. 3. Regarding the exposure conditions over the output dose, all linearity showed the coefficient of variation which had an allowable limit of error within 0.05. Although the output dose ratio for the inverter device was 1.00~1.10 times no difference that of the three-phase device, there was almost no difference in dose ratio between the tube currents.