• Title/Summary/Keyword: district Dong office

Search Result 35, Processing Time 0.027 seconds

Location Characteristic of School - Moved Sites in Busan Metropolitan City (학교시설 이적지의 시설입지 전·후 특성에 관한 연구)

  • Kim, Kyung-Su;Baek, Tae-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.10 no.2
    • /
    • pp.103-111
    • /
    • 2007
  • Since the 1980's the school of Busan metropolitan city has been converted into the other land-use such as high-rise apartment houses, commercial and office buildings. School facilities are available to locate in green area due to not restricted by land use zone. And the location of school facilities were closely related with the school district, distribution of neighborhood unit, safety of students, and so on. The purpose of this study is to understand the location characteristic of school - moved sites in Busan metropolitan city.

  • PDF

PC Interlocked Terminal-based Public Offices Fees Payment Management System (PC 연동 단말기 기반의 관공서 제세공과금 수납관리 시스템)

  • Shin, Dong-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.5
    • /
    • pp.50-60
    • /
    • 2009
  • Recently, the traffic card is gradually utilized and its several supplementary services have been significantly developed. Particularly, since it is possible to pay fees for buses, taxies, subways, parking and tollgates with only one traffic card, new payment method for economically processing has been focused. This paper presents a new receipt management system which allows possibly paying with several digital cards through PC interfacing terminals. The proposed system is mainly composed of three parts: terminals, middleware, and management servers. A terminal part includes processing module for payment/charging and credit/check/debit cards, etc and its operation is fulfilled through a middleware part. A main task of a middleware part is to connect a terminal part to managing servers through middleware applications. Additionally, processing of several receipt items and monitoring of the terminals to product statistical reports based on the processed result are carried out in the middleware. A management sever part is accomplished for collecting all of transaction histories against users and charging items over allowed province and managing statistical information. The proposed system is currently utilized in the Nam-GU district office and the Nam-GU district health center, Busan, S. Korea, respectively for testing its effectiveness. We conclude from this demonstration that the system is more useful and efficient than the previous processing method especially in that variable payment ways are provided and consumption burden is reduced.

Analysis of Water Quality Fluctuations in Upstream Namhan River Watershed Using Long-term Statistical Analysis (통계적 경향 분석을 통한 남한강 상류 수계 수질 변동 해석)

  • Byeon, Sang-Don;Noh, Yeon-Jung;Lim, Kyeong-Jae;Kim, Jong-Gun;Kim, Dong-Jin;Hong, Eun-Mi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.5
    • /
    • pp.15-26
    • /
    • 2020
  • There are fifteen non-point pollution management areas in Korea and three of them (Doam lake, Daegi district and Golji-cheon) are located in the upstream of the Namhan river watershed. Many efforts to reduce non-point sources (NPS) pollution have been conducted, however, water quality pollution in the watershed is still serious. To solve these problems, it is a priority to grasp water quality using statistical techniques. In this study, a trend analysis was conducted to evaluate the effect of NPS management in the watershed. The long-term trends from 1996 to 2018 of water quality properties were analyzed using data collected from the water environment information system. Seventeen monitoring stations were selected along the main stream in Namhan river basin. Monthly water quality properties (BOD, COD, TN, TP, TN/TP ratio, Conductivity, SS and Chlorophyll-a) were collected and analyzed by Mann-Kendall test and LOWESS. The results showed that the Conductivity tended to increase in all regions and was the highest level in Jijangcheon. Organic pollution such as BOD and COD tended to increase in the Jungseon area. SS did not show a large tendency, but it showed high concentration in the Doam watershed. In all regions, 40% of water quality properties showed a tendency to 'UP', 15% of water quality properties tended to 'DOWN', and 46% indicated no tendency. In order to determine the cause of this, additional research and measures for improvement are necessary. This study will be used for the establishment of water quality policy in the future.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

A Study on the Consciousness of the Environment Pollution Problem in Pohang City (환경문제에 관한 시민의식 조사 - 통합후 포항시민을 대상으로 -)

  • Ha, Yeong-Gil;Park, Kyung-Min;Kwon, Young-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.21 no.1
    • /
    • pp.61-73
    • /
    • 1996
  • This study conducted to determine the attitude on environment pollution by Pohang city citizens. 1,059 Pohang city citizens in the age group 20 and over were chosen and surveyed by officials's interview at Up, Myun and Dong during the period 6 September to 20 September 1995. The issue problems to be solved in Pohang city were traffic control 47.3%, environment pollution 22.7%, cultural institutions 11.6%, water service 9.9%, education system 5.1% and community security 2.1%. The 55.1% of subjects responded that responsibility for environment pollution is every citizens duty. The trash from houses were 'garbage'(48.1%), 'waste of life'(21.8%), 'reuse trash'(15.6%) and 'one use thing'(14.5%) in order. The 66.9% of subjects responded that the trash's standard envelopes can be easily tear and its texture is not good. The respondents sometimes or often had experienced foreign bodies, sediment in the water service supply. The 45.9% of the respondents use natural water as drinking water, and the water service supply(26.7%), underground water(17.0%) and buying water(9.3%) were followed. Pertaining to the air pollution(by percent) was pollution of the steel industry complex 78.0%, combustive gas 16.6% and construction dust 1.7%. The respondents at southern district complained of respiratory tract by air pollution and the respondents at northern district complained of the visual disturbance and the offensive odor(P<0.05). Water pollution problem is factory's wastewater 56.2%, home wastewater 36.4% and livestock's wastewater 5.6% in order. The respondents at southern district complained of the noise pollution by airplanes and factories at the afternoon and the respondents at northern district complained of the noise pollution by vehicles(P<0.05).

  • PDF

Transitions of Urban Parks in Busan noticed by the Chosun Planning Ordinance in the Japanese Colonial Period (일제강점기 조선시가지계획령에 고시된 부산 소재 도시공원의 변천)

  • Kim, Yeong-Ha;Yoon, Guk-Bin;Kang, Young-Jo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.1
    • /
    • pp.1-15
    • /
    • 2017
  • This study investigated the process of change of 32 urban parks designated during the period of Japanese colonial rule according to growth and development of the city in Busan. Particularly, researching included analyizing books, notification, data, and documents relevant to the history of urban planning published by Busan city. As a result, Daejeong Park, Gokwan Park, and Yongdusan Park had been utilized by Japanese residents under the Japanese colonial rule before planning of urban parks, and 32 parks legally specified in 1944 were planned by considering the prevention against disasters. After emancipation, there were an unauthorized building, housing construction, business district, public office, and school facility in the sites of the parks due to the influence of the Korean War and reorganization of urban planning. The majority of parkways and small parks downtown were eliminated. However, unexecuted parks that the government had designed on the edge of town during the Japanese colonial period have become major parks downtown through the city's growth. Yeonji Park, Yangjeong Park, and Danggok Park have been being building as a business of parks for a comfortable city, forming downtown along with the Green-Busan Policy. Thus, 32 parks designated under the Japanese colonial rule have made or got out of use reflecting on the phases of the times of modern Korean society. It turns out that these parks need an investigation about condition for land possession and purchase of the site of the parks in order for social common capital.

Utilization of Space based Digital Information for Land Information around the Acreage of a Lot (필지 중심 토지정보화를 위한 공간기반 수치정보의 활용방안)

  • Jung, Dae-Young;Shin, Young-Chul;Jung, Young-June
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.3
    • /
    • pp.11-22
    • /
    • 2005
  • It is necessary to arrange and analyze the collected research date to get regularity such as characteristics, merits and demerits, and possibility in city when constructing land information by analyzing linkage and utilization of cadastral information as the fundamental data for land information around the acreage of a lot and by expressing the purpose of each digital data construction with map. In short, that is the work to classify data, to make chart or map, or to analyze using statistical technique. Some information in land utilization had been used by computerization, but several problems were found in common use of total divisions. The most important problem is, in the case of drawing information, that topographical map with building boundary and land registration map with acreage boundary cannot be used together. In the case of property information, common utilization of property information that is basically needed and standard measurement of usage classification are necessary. The characteristics of the land usage data by the rearrangement of the cadastral information. etc. is presented as the basic data for the land information orientation, and the analyzing result of the data should be expressed and controlled on the map as the fundamental survey for the establishment of the land information oriented planning supports the physical space planning of the land cadaster finally. In this research, the problem in establishing current land information around acreage of a lot was found to research data to be needed in land information for utilizationof space based digital information, and was studied the method in relation to GIS.

  • PDF

Effects of Organic Acids on Growth Performance, Gastrointestinal pH, Intestinal Microbial Populations and Immune Responses of Weaned Pigs

  • Li, Zheji;Yi, Ganfeng;Yin, Jingdong;Sun, Peng;Li, Defa;Knight, Chris
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.2
    • /
    • pp.252-261
    • /
    • 2008
  • Two experiments were conducted to compare the effects of feeding organic acids and antibiotic growth promoters in weaned pigs. In Exp. 1, 96 nursery pigs (Large White$\times$Landrace; initial weight $7.80{\pm}0.07kg$) were randomly allotted into one of four dietary treatments. Pigs in treatment 1 were fed a complex starter diet. Treatments 2 to 4 were the same as treatment 1 but supplemented with antibiotics (200 ppm chlortetracycline plus 60 ppm Lincospectin), 0.5% potassium diformate or 0.5% dry organic acid blend ACTIVATE Starter DA (ASD). During the 4-week post-weaning period, pigs fed ASD or antibiotics had better gain (p = 0.03) and feed efficiency (p = 0.04) than pigs fed the control diet. On d 14 post-weaning, pigs fed the control diet had the lowest fecal lactobacilli count among all dietary treatments (p = 0.02), whereas pigs fed ASD or antibiotics had a trend for lower fecal E. coli count compared to the control pigs (p = 0.08). Serum insulin-like growth factor-1 (IGF-1) of pigs fed ASD did not differ from pigs fed the control diet (p>0.05) at d 14 after weaning. In Exp. 2, 24 weaned pigs (Large White$\times$Long White; initial weight $5.94{\pm}0.33kg$) were allotted into four groups and housed individually. Pigs were fed a control diet or diets supplemented with antibiotics (100 ppm colistin sulfate, 50 ppm Kitasamycin plus 60 ppm Olaquindox), 0.5% or 1% ASD. All pigs were orally challenged with E. coli $K88^+$ on d 5. During d 5 to 14 after challenge, pigs fed antibiotics, 0.5% or 1% ASD had better gain (p = 0.01) and feed efficiency (p = 0.03) than pigs fed the control diet. On d 14, compared to the control pigs, pigs fed 0.5% ASD had higher lactobacilli in the duodenum and pigs fed 1% ASD and antibiotics had a trend for higher lactobacilli in the ileum (p = 0.08). Pigs fed antibiotics, 0.5% or 1% ASD diets tended to have decreased ileal E. coli count compared to those fed the control diet (p = 0.08). Serum interleukin-6 and cortisol and digesta pH values were not affected by treatment or time. These results indicate that feeding ASD can improve the growth performance of weaning pigs, mainly via modulating intestinal microflora populations without affecting gastrointestinal pH or immune indices.

A study on vegetation and soil environmental characteristics of green roof in Daejeon Metropolitan City (대전광역시 옥상녹화 지역의 식생현황 및 토양환경 특성에 관한 연구)

  • Lee, Sang-Jin;Park, Gwan-Soo;Lee, Dong-Kun;Jang, Seong-Wan;Park, Beom-Hwan;Lee, Hang-Goo;Yun, Joon-Young;Jang, Kwan-Woo;Lee, Seung-Woo;Lee, Ho-Young;Kwon, Oh-Jung;Lee, Sook-Mee;Kil, Sung-Ho
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.4
    • /
    • pp.641-649
    • /
    • 2011
  • This study was to analyze the soil environmental characteristics and vegetation status of green roof in Daejeon Metropolitan City. The investigated floras of vascular plants are 17 families, 26 genera, 28 species in Seo-Gu Daejeon District Office Building (SG), 25 families, 49 genera, 56 species in Galma Public Library (GP), and 34 families, 57 genera, 60 species in Daejeon City Hall (DC) respectively. Although the larger area shows the more numbers of species in introduced plants and naturalized plant, the naturalized plant ratios were similar with each other. They were 10.71%, 10.71%, and 11.67% at SG, GP, and DC respectively. As a result of analysis on soil physical property, soil depths including vegetation soil and drainage soil of 3 green roofs were 30cm. The depths of vegetation soil at SG, GP, and DC were 0~8cm, 0~10cm, 0~10cm respectively. As a results of soil chemical properties of our study, soil pH of vegetation soil and drainage soil were a range of 6.42 and 7.43, and a range of 6.55 and 7.43 on the average respectively. Available-P contents of vegetation soil and drainage soil were a range of 153.33 and 366.33mg/kg, and a range of 136.67 and 242.67 mg/kg which is very high, respectively. Carbon contents in soil at vegetation soil and drainage soil were a range of 3.16 and 6.38%, and a range of 1.63 and 2.47% respectively. Carbon storage per square meter within 30 cm were 2.76 kg, 2.99 kg, and 3.66 kg at SG, GP, and DC respectively.

Outbreak of Anguillid herpesvirus-1 (AngHV-1) infection in cultured shortfin eel (Anguilla bicolor) in Korea (양식 동남아산 뱀장어, Anguilla bicolor의 Anguillid herpesvirus-1 (AngHV-1) 감염증)

  • Park, Sung-Woo;Jung, Eun-Bin;Kim, Dong-Wan
    • Journal of fish pathology
    • /
    • v.25 no.3
    • /
    • pp.151-158
    • /
    • 2012
  • Diseased eel (Anguilla bicolor) displayed severe hemorrhages in the gills, and congestion and swelling in the liver. During the epizootic, the water temperature was $28^{\circ}C$ and the morality rates were about 5%. No parasites were found on the gills and skin. Bacteria were not cultured from any internal organs using TSA or SS agar at $28^{\circ}C$ for 48 hrs. Histopathologically, the gills showed epithelial hyperplasia in the base of secondary gill lamellae and hemorrhages in the capillaries. Some cells in the proliferated interlamellar epithelia exhibited marginal hyperchromatosis. And severe vacuolated changes in the parenchymal cells and congestion in the central veins were observed in the liver. The specific amplicon (396 bp) was detected from gills and opercula of affected eel PCR using Anguillid herpesvirus-1 (AngHV-1) -specific primer sets HVAPOLVPSD (5-'GTG TCG GGC TTT GTG GTG C-3') and HVAPOLOOSN (5'-CAT GCC GGG AGT CTT TTT GAT-3'). Sequencing analysis of the amplicon demonstrated that this gene was 99% homologous to the AngHV-1 sequence deposited in GenBank. This is the first report of AngHV-1 outbreak in the farmed shortfin eels (A. bicolor) in Korea. When diseased fish were maintained for 10 days at water temperatures of $32^{\circ}C$ and $35^{\circ}C$, the cumulative mortalities were 100% and 10%, respectively. Even though the AngHV-1 genome in the gills from the eel kept at $35^{\circ}C$ was detected using PCR, the structure of gill filaments was similar with that of normal fish. Increasing the water temperature to $35^{\circ}C$ was an effective way to diminish the mortality of AngHV-1 affected eel.