Performance analysis of Non-linear Power Amplifier on The DS-CDMA Systems (비선형 전력증폭기로인한 DS-CDMA 통신시스템의 성능분석)

  • 최성호;목진담;손동철;김성철;정희창
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.4
    • /
    • pp.531-538
    • /
    • 1998
  • In this paper the system performance degradation resulting from nonlinear transmitter power amplifier which is essential to increase the efficiency is analysed in a CDMA system. The power amplifier is modeled by its AM-AM, AM-PM characteristics. The effects of power amplifier's nonlinearity such as intersymbol interference, phase distonion on the RF system performance were visualized by examining the distorted time domain waveforms, signal vector constellation. And through the investigation of the power spectrum density of the transmitted signal, spectral regrowth or sideband regrowth which is result from amplitude distortion can be seen. All these characteristics result in BER performance degradation due to other user interferences and intersymbol interference. The analysis technique described here applies not only to power amplifier but also to any other nonlinear components such as mixers and switches. Also the effects of adjacent channel interference and supurious emission can be analysed between different systems.

  • PDF

An improvement of cycloconverter output using phase shifting filter (상천이 필터를 이용한 싸이클로컨버터 출력의 개선)

  • Kim, Jong-Su;Seo, Dong-Hoan;Kim, Jeong-Woo;Kim, Sung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.121-126
    • /
    • 2013
  • Cycloconverter used as a power conversion device in the speed and torque control system of AC machines has the advantage of a simple control and a large torque at low speed. In addition, because a rectifier, a DC link, and an inverter are not installed, this system is simple and suitable for large power system. If a power conversion device, which is currently used as a propulsion motor of large vessel, is changed into cycloconverter, the system is simplified and then the installation costs can be significantly reduced. However, conventional cycloconverter has the increased harmonics because the power loss is large and the waveform of output voltage is distorted, due to the high-speed switching of power semiconductor devices. In order to improve these shortcomings, this paper describes a phase shifting filter which is composed of two inputs with different phases in the primary side and one output in the secondary one. As the voltage waveforms with two different phases are added and transformed into the secondary side, these outputs are close to sinusoidal waves. Thereby the voltage waveforms, which are applied to the propulsion motors, are improved and total harmonic distortions (THDs) are significantly reduced.

Analysis of Harmonic Effects on Substation Power System and its Countermeasure (지하철 전력계통의 고조파 영향 분석 및 그 대책에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.210-220
    • /
    • 2002
  • We analysised the effect of harmonics on electric machines of substation power system barred on quantitatively measured harmonics and proposed the methods for prevention of harmonics through checking on transformer, rectifier and cable's capacities against harmonics with reference to KEPCO's electricity service standard. In order to analysis harmoninics of silicon rectifier that is power source in DC substation, computer simulations for a substation with TR of high voltage distribution switchboard are performed. Simulation results show that the total harmonic distortion factor becomes smaller for TR primary and receiving points in order rather than silicon rectifier which is harmonic generation source so that the harmonics generated frets each rectifier are outflowed to power supply and high voltage distribution switchboard The result of higher distortion factors of voltage and current for rectifier with 100% load than those with 50 % and 30% indicates that the waveform of voltage and current for the real substation power system at the office-going and the closing hours with heavy loads might be more distorted. As proposed methods for harmonic reduction, the conventional 6 pulse-type for substation is required to be replaced by 12 pulse-type for reduction of 5th and 7th harmonics. The active filter rather than the passive filter is more effective due to severe variance of rectifier loads, but the high cost is price to be paid. In view of installation area and costs, the use of 12 pulse-type transformer is desirable and then the parallel transformer and the rectifier within the substation must be replaced at the same time. Other substations with parallel feeder can use 6 pulse-type transformer.

Vulnerability Case Analysis of the High Power Electromagnetic Pulse on Digital Control System (디지털 제어장치의 고출력 전자기펄스에 대한 취약성 사례 분석)

  • Woo, Jeong Min;Ju, Mun-No;Lee, Hong-Sik;Kang, Sung-Man;Choi, Seung-Kyu;Lee, Jae-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.9
    • /
    • pp.698-706
    • /
    • 2017
  • The risk of high power electromagnetic(HPEM) pulse exposure to the devices used in digital control system such as PLC(programmable logic controller) and communication cable is increasing. In this paper, two different frequency ranges HPEMs were exposed to those control systems to assess the each vulnerability. The vulnerability of the EUTs exposed from HPEM were analyzed and compared with a variation of distances and source power. As the EUTs were exposed to higher level of HPEM, the voltage and communication waveform of the control system had shown a distorted response. And the unshielded twisted pair(UTP) cable connected to the EUTs showed operation failures with induced voltage. However, the foiled twisted pair(FTP) cable shielded the connected device efficiently from the HPEM exposure. Therefore, the necessity of the protection measures against the vulnerability of HPEM exposure for the digital control system used in power facilities and industrial site were verified.

Monopsony Power of General Hospitals in Nurse Labor Market (간호사 노동시장의 수요독점에 대한 연구 - 종합병원을 중심으로 -)

  • Jeong, Hyun-Jin;Yang, Bong-Min
    • Korea Journal of Hospital Management
    • /
    • v.5 no.2
    • /
    • pp.40-58
    • /
    • 2000
  • Nurses are medical personnel, who play a key role in supporting patient care, so it is important to supply them adequately in balance with ever increasing medical demand. But there appears severe shortage of nurses in some hospitals because of their uneven distribution, especially in small sized-hospitals and rural-hospitals. As nationwide distorted distribution of nurses in Korea is just like what monopsony model(a kind of market structure model) tells us, it is attempted to explain this situation of nurse labor market in Korea on the basis of monopsony model and presented in this paper. Specifically, determinants of nurse wage and the level of their relative employment were examined, and monopsony impact on their wage and the level of relative employment controlling those determinants were studied. Major results of this study arc as follows. The most important determinant of nurse wage level in this study was the wage level of a local community where each hospital located Hospital owner's characteristics an educational function of each hospital were also important factors. With these factor controlled, it was found that monopsony power of each hospital was negativel associated with nurse wage level as expected. 1% increase in monopsony power of hospital(measured by Herfindah-Hirschman Index) reduced nurse wage by $5,674{\sim}19,19$ won(in Korean currency). With regard to the level of relative employment, the most important determinant wa the capacity for supplying nurses of the local community. Again, hospital owner characteristics and educational function of each hospital were also important. With these factors controlled, it was found that monopsony power of each hospital was negative associated with the number of nurses per bed, as expected. 1% increase in monopsony power of each hospital(again measured by Herfindah-Hirschman Index) reduced the number of nurses per 100 bed as much as $0.46{\sim}0.67$. In conclusion. structural factors of nurse labor market influence the instability of nurse labor supply in Korea. Further consideration for these market structural characteristics needed for policy making related to nurse resource allocation.

  • PDF

A New Method on the Nonlinear Distortion Analysis in the OFDM Communication System (OFDM 통신 시스템에서 비선형 왜곡분석의 새로운 분석기법)

  • 이동훈;정기호;유흥균
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.6
    • /
    • pp.538-545
    • /
    • 2002
  • In the orthogonal frequency division multiplexing (OFDM) system, the nonlinear distortion in the high power amplifier(HPA) degrades the system performance because of the high peak-to-average power ratio (PAPR). In this paper, a semi-analytical method is newly proposed for the performance evaluation of the nonlinearly distorted OFDM communication system. In the proposed method, at first, the probability density function (pdf) of the PAPR is generated by computer simulation. Then, mean and variance of the non-linear distortion noise process are computed. Next, the overall BER is found by the analytical method. When the equivalent SSPA model is applied in case of the QPSK/16-QAM and AWGN channel, the BER is calculated for the variation of the IBO(input back-off) and PAPR parameter. It is shown that the results by proposed method are very similar to those of the conventional Monte-Carlo method. The computation time can be considerably reduced than the conventional method that depends on the magnitudes of BER and IBO.

Performance Improvement of Power Analysis Attacks based on Wavelet De-noising (웨이블릿 잡음 제거 방법을 이용한 전력 분석 공격 성능 개선)

  • Kim, Wan-Jin;Song, Kyoung-Won;Lee, Yu-Ri;Kim, Ho-Won;Kim, Hyoung-Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.9B
    • /
    • pp.1330-1341
    • /
    • 2010
  • Power analysis (PA) is known as a powerful physical attack method in the field of information security. This method uses the statistical characteristics of leaked power consumption signals measured from security devices to reveal the secret keys. However, when measuring a leakage power signal, it may be easily distorted by the noise due to its low magnitude values, and thus the PA attack shows different performances depending on the noise level of the measured signal. To overcome this vulnerability of the PA attack, we propose a noise-reduction method based on wavelet de-noising. Experimental results show that the proposed de-noising method improves the attack efficiency in terms of the number of signals required for the successful attack as well as the reliability on the guessing key.

Harmonic Signal Linearization of Nonlinear Power Amplifier Using Digital Predistortion for Multiband Wireless Transmitter (다중 대역 송신을 위한 디지털 사전 왜곡 기법을 이용한 비선형 전력 증폭기의 고조파 신호 선형화)

  • Oh, Kyung-Tae;Ku, Hyun-Chul;Kim, Dong-Su;Hahn, Cheol-Koo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1339-1349
    • /
    • 2008
  • In this paper, a nonlinear relationship between an input complex envelope and an output complex envelope of m-th harmonic zone is theoretically analyzed, and AM/$AM_m$ and AM/$PM_m$ are defined. A scheme to extract these characteristics from measured in-phase and quadrature-phase data is suggested. The proposed analysis is verified with a fundamental-fundamental and fundamental-third harmonic measurements for a InGaP power amplifier(PA). Based on the harmonic-band nonlinear analysis and extraction scheme, a new technique to send a signal in m-th harmonic band with a harmonic signal Linearization Digital Predistortion(DPD) scheme is presented. A numerical analysis and a Look-Up Table(LUT) based DPD algorithms to linearize output signal on m-th harmonic zone are developed. For a 16- and a 64-QAM input signals, a DPD for third harmonic signal linearization is implemented, and output spectrum and signal constellation are measured. The wholly distorted signals are linearized, and thus the measured Error Vector Magnitudes (EVM) are 6.4 % and 6.5 % respectively. The results show that a proposed scheme linearizes a nonlinearly distorted harmonic band signals. The proposed nonlinear analysis and predistortion scheme can be applied to multiband transmitter in next generation software defined radio(SDR)/cognitive radio(CR) wireless system.

Dispersion-Managed Optical Transmission Link Adding of Non-Midway OPC (Non-Midway OPC를 추가한 분산 제어 광전송 링크)

  • Lee, Seong-Real
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.5
    • /
    • pp.408-414
    • /
    • 2020
  • The method of overcoming the limitation of optical phase conjugator applied into optical long-haul link for transmitting high capacity wavelength division multiplexed (WDM) channels was investigated. The configuration of optical link was based on dispersion-managed link, in which dispersion compensating fiber inserted into each fiber span with single mode fiber, and optical phase conjugator was added into suitable location of link. The maximum number of fiber spans as a function of the launch power of WDM channels in optical link with optical phase conjugator placed at the proposed location was induced and compared for analyzing the compensation performance of the distorted WDM channels. It was confirmed that the more optical phase conjugator depart from the midway of total transmission length, the less the distorted WDM channels was compensated, however, it was also confirmed that the degradation of compensation can be overcome by the suitable value of residual dispersion per span and by the reasonable choice of fiber span controlling total dispersion accumulated in overall transmission link.

Digital Radiography Images Restoration with Wiener Filter in Wavelet Domain (웨이블릿영역에서 위너필터를 이용한 디지털 방사선 영상 복원)

  • Jeong, Jae-Won;Kim, Dong-Youn
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.6
    • /
    • pp.58-64
    • /
    • 2009
  • Digital radiography (DR) images are corrupted by the additive noise, and also distorted by system impulse response. These unwanted phenomena are obstacles to obtain the desired image. To recover the original image, we applied multiscale Wiener filters in wavelet domain for DR images. The multiscale Wiener filter is first proposed by Chen for the restoration of fractal signals which are distorted by the system impulse response and additive noise. In this paper, we extended the multiscale Wiener filter to the two dimensional data. To compare the performance of ours with others, some simulations are given for a couple of wavelet filters with different wavelet levels, system impulse reponses and various noise power. When the addive noise powers are between 20-32 dB, the signal to noise ratio(SNR) of the proposed system is 0.5-2.0 dB better than that of the traditional Wiener filter method.