• Title/Summary/Keyword: distillation operation

Search Result 77, Processing Time 0.026 seconds

Desalination technology for a barge mounted plant (해상 플랜트용 담수화장치 기술개발)

  • 김재윤;박상진;송치성
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.112-116
    • /
    • 2001
  • In the paper, desalination technology for a barge mounted plant is presented. Desalination system on a barge needs high efficiency, smaller space, and stability. Therfore 4-effect distillation system (capacity of 50ton/day) is designed and constructed. During operation, detailed investigation of different opereation parameters is carried. This paper discusses about product water flowrate and recover ratio with different steam flow rate and feed water rate.

  • PDF

Feasibility Study of Gamma Ray Transmission Technique in Distillation Column Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 감마선 투과계측 증류탑 진단기술의 타당성 연구)

  • Moon, Jinho;Kim, Jongbum;Park, Jang Guen;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.115-119
    • /
    • 2013
  • The density profile measurement technology by gamma transmission has been widely used to diagnose processes in the field of refinery and petrochemical industry. This technology can reveal a clue and position of abnormal phenomenon of industrial processes during their operation. In this paper, the feasibility of the gamma transmission technology for detecting changes in the amount of fluid in a distillation column was evaluated by using Monte Carlo simulations. The simulations assumed that $^{60}Co$ (1.17, 1.33 MeV) sources and NaI (Tl) detectors (${\Phi}5{\times}5cm$) are located in opposite sides of a column and it concurrently moves in vertical direction. To determine the dependency of a spatial resolution on aperture size of a collimator, the simulation model for a tray in a column were simulated with the aperture sizes of 1 and 2 cm. The thickness of the high density area including a tray and fluid was 7.6 cm in the simulation. The spatial resolution of the tray was 8.2 and 8.5 cm, respectively. As a result, it was revealed that the conventional density profile measurement technique is not able to show the deviation of liquid level on a tray in a column.

Performance Evaluation of a Closed-Loop Pressure Retarded Membrane Distillation for Brackish Water Desalination and Power Generation (기수담수화와 전력 생산을 위한 폐루프형 압력 지연식 막 증류 공정의 성능 평가)

  • Cho, Gyu Sang;Lee, Jun-Seo;Park, Kiho
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.525-534
    • /
    • 2022
  • In this study, we investigated the applicability and optimal operating strategy of a closed-loop pressure retarded membrane distillation (PRMD) for brackish water desalination. For effective operation with net power generation, high temperature of heat source over 90 ℃ and feed flow rate at 0.6 kg/s are recommended. At 3 g/L of feed concentration, the average permeate flux and net energy density showed 8.04 kg/m2/hr and 2.56 W/m2, respectively. The average permeate flux and net energy density were almost constant in the range of feed concentration from 1 to 3 g/L. Compared to the case with seawater feed, the PRMD with brackish water feed showed higher average permeate flux and net energy density. Thus, PRMD application using brackish water feed can be more effective than that using seawater feed in terms of power generation.

Options Study for the Neutralization of Elemental Sodium During the Pyroprocessing of Used Nuclear Fuel

  • Westphal, Brian;Tolman, David;Tolman, Kevin;Frank, Steven;Herrmann, Steve;Warmann, Stephen;Marsden, Kenneth;Patterson, Michael
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2
    • /
    • pp.113-118
    • /
    • 2020
  • An options study was performed for the treatment of residual elemental sodium in driver plenums following the chopping operation during the pyroprocessing of used nuclear fuel. Given the pending availability of a multi-function furnace for distillation and consolidation operations in the Fuel Conditioning Facility, the furnace was considered for the processing of driver plenums. Although two options (oxidation and distillation) could be performed in the multi-function furnace, neither option has been developed sufficiently to date to warrant the use of the furnace for treatment operations. Thus, it was decided to defer the treatment of elemental sodium from driver plenums in the multi-function furnace until more developed technologies and/or furnaces become available. In the interim, storage of the plenums and characterization efforts are recommended.

A Study on the Contamination of Solution with Suction used in Tracheostomy Patients (기관지절개술 환자의 흡인시 사용하는 용액의 오염수준 변화 연구)

  • Lim Yun-Hee;Yu Kwang Soo
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.185-200
    • /
    • 1998
  • It has been contributed to public health that the hospital has multiplied in the aspect of number and has been a large size with development of modern medical science, meanwhile the problem of hospital infection is coming out seriously. Respiratory hospital infection among hospital infections develops, very commonly from patients having taken the operation of intubation or tracheostomy, which results from a big factor that the infection developed from medical appliances used for respiration aids, contamination of solution and infection of medical staff. This study is separated into four steps-the time to use normal saline and distillation water for storaging catheter which are the cause of the infection of solution to store distillation water and catheter, not to say the catheter used when the patient who should get tracheostomy operation takes suction. The purpose of this study is to offer the basic data which are needed to check contamination degree as time goes by and nurse intervention and grope for a new nursing intervention. The target of this study is hospitalized 1D an intensive care unit having 700 sickbeds which is located in IKSAN city and it targeted patients before 7 days passed after an operaion of a tracheostormy. Materials collected were analyzed by SPSS PC+ figures program. The result of this study were as follows ; 1. The gradual contamination levels of the normal saline used In suction are showing that colony increase in proportion to the length of time. 2. while colony increases in normal saline with the lapse of time. distillation water mixed with 5cc of potadine did not show any sign of the formation of colony from its preparation until it was used for 8 hours. 3. Such variables as the period of intubation insertion. the length of hospitalization in I.C.U. the age and the level of contamination of normal saline have no inter-relationship. Therefore. as the length of normal saline used In suction. the contamination level increases with the excelleration of the contamination speed. 4. Regarding the number of suction and the contamination level of the normal saline. We can observe correlation contamination level in the 3 step of suction(mean value:13.4) and the saline which was used for one hours(r=0.702. P=0.00l). four hours(r=0.694. P=0.00l). eight hours(r=0.488. P=0.029). Further we can observe contamination in the 4 step of suction (mean value: 17 .8) well as saline used for eight hours; [for one hours (r=0.64l. P=0.002). four hours (r=0.670. P=0.00l). eight hours (r=0.57 4. P=0.008)]. Thesedays clinics use normal saline by changing it. three times a day. however. the timing of saline change and the current suction methoed should be changed given the one hour used normal saline contamination number 79.850. Regarding the number of suction and the contamination lend of the normal saline.

  • PDF

Development of Machine Learning-Based Platform for Distillation Column (증류탑을 위한 머신러닝 기반 플랫폼 개발)

  • Oh, Kwang Cheol;Kwon, Hyukwon;Roh, Jiwon;Choi, Yeongryeol;Park, Hyundo;Cho, Hyungtae;Kim, Junghwan
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.565-572
    • /
    • 2020
  • This study developed a software platform using machine learning of artificial intelligence to optimize the distillation column system. The distillation column is representative and core process in the petrochemical industry. Process stabilization is difficult due to various operating conditions and continuous process characteristics, and differences in process efficiency occur depending on operator skill. The process control based on the theoretical simulation was used to overcome this problem, but it has a limitation which it can't apply to complex processes and real-time systems. This study aims to develop an empirical simulation model based on machine learning and to suggest an optimal process operation method. The development of empirical simulations involves collecting big data from the actual process, feature extraction through data mining, and representative algorithm for the chemical process. Finally, the platform for the distillation column was developed with verification through a developed model and field tests. Through the developed platform, it is possible to predict the operating parameters and provided optimal operating conditions to achieve efficient process control. This study is the basic study applying the artificial intelligence machine learning technique for the chemical process. After application on a wide variety of processes and it can be utilized to the cornerstone of the smart factory of the industry 4.0.

In-service Investigation on the Flow Dynamics of a Trayed Column from the Measurement of an Internal Density by using a Gamma Absorption Technique (Gamma Absorption Technique를 이용한 Trayed Column의 가동 중 내부 밀도분포 측정에 의한 유체 유동상태 진단)

  • Kim, Jae-Ho;Kim, Jong-Bum;Kim, Jin-Seop;Lee, Na-Young;Lee, Sung-Sik;Jang, Seok-Joon;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • A distillation tower is one of the important facilities which separates and refines a crude oil stream according to certain boiling points. Its operation efficiency can affect the productivity of a refinery substantially. The objective of this study is to elucidate some operational information on the internal conditions of a distillation tower from a measurement of density profile by using a sealed gamma-ray source and a radiation detector. Gamma radiation counts were measured by a BGO detector positioned diametrically outside the tower-wall, opposite to the gamma source(Co-60) as the detector and the source were lowered concurrently. From the results, structural abnormality of the trays was not found inside the tower. Considering the flow distribution patterns, however, a vapor phase was dominantly formed at the upper part of the tower and a liquid phase at the lower part. From the gamma scanning of the distillation tower, it is anticipated that the gamma absorption technique can be used as an important tool for confirming the structural soundness of trays and investigating flow distribution in refinery facilities.

Prediction of Distillation Column Temperature Using Machine Learning and Data Preprocessing (머신 러닝과 데이터 전처리를 활용한 증류탑 온도 예측)

  • Lee, Yechan;Choi, Yeongryeol;Cho, Hyungtae;Kim, Junghwan
    • Korean Chemical Engineering Research
    • /
    • v.59 no.2
    • /
    • pp.191-199
    • /
    • 2021
  • A distillation column, which is a main facility of the chemical process, separates the desired product from a mixture by using the difference of boiling points. The distillation process requires the optimization and the prediction of operation because it consumes much energy. The target process of this study is difficult to operate efficiently because the composition of feed flow is not steady according to the supplier. To deal with this problem, we could develop a data-driven model to predict operating conditions. However, data preprocessing is essential to improve the predictive performance of the model because the raw data contains outlier and noise. In this study, after optimizing the predictive model based long-short term memory (LSTM) and Random forest (RF), we used a low-pass filter and one-class support vector machine for data preprocessing and compared predictive performance according to the method and range of the preprocessing. The performance of the predictive model and the effect of the preprocessing is compared by using R2 and RMSE. In the case of LSTM, R2 increased from 0.791 to 0.977 by 23.5%, and RMSE decreased from 0.132 to 0.029 by 78.0%. In the case of RF, R2 increased from 0.767 to 0.938 by 22.3%, and RMSE decreased from 0.140 to 0.050 by 64.3%.

Operation of dry distillation process on the production of radionuclide 131I at Puspiptek area Serpong Indonesia, 2021 to 2022

  • Chaidir Pratama;Daya Agung Sarwono;Ahid Nurmanjaya;Abidin Abidin;Triyatna Fani;Moch Subechi;Endang Sarmini;Enny Lestari;Yanto Yanto;Kukuh Eka Prasetya;Maskur Maskur;Fernanto Rindiyantono;Indra Saptiama;Anung Pujiyanto;Herlan Setiawan;Tita Puspitasari;Marlina Marlina;Hasnel Sofyan;Budi Setiawan;Miftakul Munir;Heny Suseno
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1526-1531
    • /
    • 2024
  • 131I is a fission product produced in a nuclear reactor by irradiating tellurium dioxide, with a half-life of 8.02 day. The most important and widely used method for making 131I is irradiation using a nuclear reactor and post-irradiation followed by dry distillation. The advantage of the dry distillation process is that the process and the equipment are relatively simple, namely TeO2 (m.p. 750 ℃), which can withstand heating during reactor irradiation. Based on TeO2 irradiation by neutron following the technique of dry distillation was explained for production of 131I on a large scale. A dry distillation followed the radioisotope production operation using the 30 MW GA Siwabessy nuclear reactor to meet national demand. TeO2 targets are 25 and 50 g irradiated for 87-100 h. The resulting 131I activity is 20.29339-368.50335GBq. According to the requirements imposed on the radionuclide purity of the preparation, the contribution of 131I training in the resulting preparation was not less than 99.9 %

Recovery of Ammonium Salt from Nitrate-Containing Water by Iron Nanoparticles and Membrane Contactor

  • Hwang, Yu-Hoon;Kim, Do-Gun;Ahn, Yong-Tae;Moon, Chung-Man;Shin, Hang-Sik
    • Environmental Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.111-116
    • /
    • 2012
  • This study investigates the complete removal of nitrate and the recovery of valuable ammonium salt by the combination of nanoscale zero-valent iron (NZVI) and a membrane contactor system. The NZVI used for the experiments was prepared by chemical reduction without a stabilizing agent. The main end-product of nitrate reduction by NZVI was ammonia, and the solution pH was stably maintained around 10.5. Effective removal of ammonia was possible with the polytetrafluoroethylene membrane contactor system in all tested conditions. Among the various operation parameters including influent pH, concentration, temperature, and contact time, contact time and solution pH showed significant effects on the ammonia removal mechanism. Also, the osmotic distillation phenomena that deteriorate the mass transfer efficiency could be minimized by pre-heating the influent wastewater. The ammonia removal rate could be maximized by optimizing operation conditions and changing the membrane configuration. The combination of NZVI and the membrane contactor system could be a solution for nitrate removal and the recovery of valuable products.