• 제목/요약/키워드: distance meter

검색결과 237건 처리시간 0.024초

Laser를 이용한 후물 판재류 및 Slap폭 측정 적용 (Application of slab and plate width measurement using laser distance meter)

  • 최철호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1076-1078
    • /
    • 1996
  • According to ascending needs for quality assurance of plate by customer and automated measurement of dimension for slab, in plate mill, project is on preceeding to install measuring system to measure width, length and camber of slab and plate using laser distance meter. In this document, I will describe not technical point of view but idea of design for installation system.

  • PDF

A Comparative Analysis of Patient Visibility, Spatial Configuration and Nurse Walking Distance in Korean Intensive Care Units(ICUs) - Focused on single corridor, Pod and Composite type units

  • 울라 우바이드;박재승
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권4호
    • /
    • pp.37-45
    • /
    • 2016
  • Purpose: The purpose of this paper is to analyze a sample of single corridor, pod type and composite type of ICUs in terms of patient visibility, spatial configurations and nurse walking distance focused on Korean cases. Methods: The measures of static visibility were used to quantify the patient visibility (upper third part of the patient bed) from the nurse station. The measure of space programme and area distribution (patient zone percentage, staff zone percentage, circulation zone percentage, corridor length per bed, distance from nurse station (NS) to patient bed and departmental gross square meter (DGSM) per patient bed) were calculated by using AutoCAD and MS Excel programs. In the second step of analysis the values of space distribution were compared among the three type of ICUs as well as the nurse walking distance, DGSM per bed and gross factor. in the third step of analysis regression analysis was conducted for the possible correlation between visibility and space programme and area distribution factors as well as nurse walking distance factors. Results: (1) It was found that on average composite type unit offer highest value of patient visibility followed by pod type, while single corridor type unit offers the minimum value of patient visibility among the three plan typologies. (2) Average patient visibility and DGSM per bed shows a strong positive correlation ($r^2=0.75$) and p=0.026. (3) Average patient visibility and average distance from NS has a strong negative correlation ($r^2=0.78$), and P=0.02. (4) On average composite type unit offer the minimum walking distance from NS (7.22 meter) followed by pod type unit (8.35 meter) and single corridor (9.76 meter). (5) Maximum distance from NS was noted in single corridor (18.19 meter) followed by pod type unit (15.14 meter) and Composite type unit (11.1 meter). Implications: This study may contribute to the visibility analysis of existing and future ICU design in Korea to achieve maximum patient visibility and reduced nurse walking distance.

원격 측정 레벨계의 최소 탐지거리 성능 개선 방법 (A Method on the Improvement of the Minimum Detection Distance of the Remote Measurement Level Meter)

  • 박동근;이기준
    • 대한원격탐사학회지
    • /
    • 제34권3호
    • /
    • pp.535-543
    • /
    • 2018
  • 최근 레벨계는 산업현장의 안전 및 유지관리와 연관되어 넓은 측정범위가 요구되는 추세이다. 일반적으로 레벨계의 측정범위를 확보하기 위해 측정환경을 개선하여 잡음을 감소시키거나 신호처리를 통해 신호의 왜곡을 보상하게 된다. FMCW 레이다 레벨계의 잡음과 신호의 왜곡은 레벨계의 근거리 특성에 영향을 주어 최소탐지거리가 감소되는 결과를 갖게 한다. 본 논문에서는 레벨계의 근거리 영역의 잡음을 제거하기 위해 window 함수와 비트 스펙트럼의 특성을 고려한 Equalizer 필터를 적용하여 최소탐지거리 성능을 개선하며 탐지가 상대적으로 어려운 레벨계 근거리의 측정 신뢰도를 높이고 탐지영역내의 측정 범위를 향상 시키고자 한다.

습식방식의 초음파 유량계 시스템 개발에 관한 연구 (A Study on the Wet Type Ultrasonic Flow-meter System Development)

  • 이응석;권오훈;노명환;이형석
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1638-1644
    • /
    • 2005
  • This paper suggests fur the study on a fluid velocity measuring system using ultrasonic transducer. In general, the time difference method to measure the distance between transducers has been known. In this paper, the practical technology for manufacturing ultrasonic flow meter system is studied using the time difference method. The ultrasonic transducer was designed and manufactured. The transmission and receiving algorithm for ultrasonic signal was studied. The ultrasonic flow measuring system was experimented in laboratory using a water reservoir for verifying the distance measuring accuracy. Finally, it was tested in flow calibration laboratory for the velocity measuring performance. The system, designed in this study, showed 0.3 mm resolution in distance measurement. For precise flow measurement, a high speed triggering algorithm is required for ultrasonic signal receiving.

자동차(自動車) 번호표(番號標)(보통 번호표(番號標)) 숫자(數字)의 가독성(可讀性)에 대한 연구(硏究) (A Study on the Readability of the Car License Plate in Korea)

  • 백승엽;조암
    • 대한인간공학회지
    • /
    • 제7권1호
    • /
    • pp.13-20
    • /
    • 1988
  • The purpose of this study is to provide basic research data on the readability of the car number license plate in Korea by experimental procedure. This study is performed by the combination of color contrasts, character forms, and stroke widths. Additionally it is focused on the distance of distinct vision and misreading rate. The results of the this study are as follows: First, as to the color contrasts, the plate which has black on yellow contrast has better readability than current contrast between white and green (white character on green plate, vice versa). Second, as the character forms, it is showed that Quasigothic and NAMEL types have less misreading rates by 42.86% and 42.15%, respectively, than current Gothic type, and they also increase distance of distant vision by 4 meter. Third, as to the stroke widths, it is showed that 12 milli-meter and 14 milli-meter of stroke widths have less misreading rates by 63.94% and 65.33 %, respectively, than current 6 milli-meter of stroke width.

  • PDF

Fluidic 유량계의 기하학적 변수가 유동률에 미치는 영향 (Effects of geometric parameters of fluidic flow meter on flow rate)

  • 박경암;윤기영;유성연
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1608-1614
    • /
    • 1997
  • The fluidic flow meter detects the gas flow rate based on the principle of fluidic oscillation instead of the conventional displacement method. It has many merits: wide rangeability, no moving mechanical parts and calibration insensitive to physical properties of fluids. The width of nozzle, size of oscillation chamber, size of target, width of outlet are tested to obtain the effects of jet oscillation on the fluidic flow meter. As the width of nozzle is too wide compared with the size of target, jet oscillation is unstable. The oscillation frequency decreases as the distance between the nozzle and target increases and also as the distance between target and outlet contraction increases. Two different vortexes exist in the front and the rear regions of the target, and they affect the oscillation frequency. The outlet contraction is very important, because the feedback flow is generated by the blocking of the flow. As the width of outlet increases, the jet oscillation frequency decreases. The linearity of this tested flow meter is quite good.

단을 가진 수평축의 비틀림진동 측정에 관한 연구 (A Study on the Torsional Vibration Measurement of the Horizontal Shaft with Disks)

  • 박일수;안찬우;김중완
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.3-8
    • /
    • 1997
  • This parer was presented for the experimental results of torsional vibrations of the horizontal rotating shaft with three disks. The torsional vibrations meter used is a laser system for non-contact measurement of torsional angular vibration velocity and torsional angular vibration displacement. The distance between the disks war changed; the one that had 76mm of disk distance war called basic model, and another that had 106mm of disk distance wide model, and other that had 46mm of disk distance narrow model. In each model, outer diameter of disk was 40mm. And 45mm, or 50mm was also used to extend the effective range of frequencies. The angula vibration displacement and the angular vibration velocity in its torsional vibration were measured to obtain the stable and the unstable regions.

  • PDF

가상현실 환경에서의 3차원 사운드 생성을 위한 거리 변화에 따른 구조적 머리전달함수 모델 (A Range Dependent Structural HRTF Model for 3-D Sound Generation in Virtual Environments)

  • 이영한;김홍국
    • 대한음성학회지:말소리
    • /
    • 제59호
    • /
    • pp.89-99
    • /
    • 2006
  • This paper proposes a new structural head-related transfer function(HRTF) model to produce sounds in a virtual environment. The proposed HRTF model generates 3-D sounds by using a head model, a pinna model and the proposed distance model for azimuth, elevation, and distance that are three aspects for 3-D sounds, respectively. In particular, the proposed distance model consists of level normalization block distal region model, and proximal region model. To evaluate the performance of the proposed model, we setup an experimental procedure that each listener identifies a distance of 3-D sound sources that are generated by the proposed method with a predefined distance. It is shown from the tests that the proposed model provides an average distance error of $0.13{\sim}0.31$ meter when the sound source is generated as if it is 0.5 meter $\sim$ 2 meters apart from the listeners. This result is comparable to the average distance error of the human listening for the actual sound source.

  • PDF

Low Cost Omnidirectional 2D Distance Sensor for Indoor Floor Mapping Applications

  • Kim, Joon Ha;Lee, Jun Ho
    • Current Optics and Photonics
    • /
    • 제5권3호
    • /
    • pp.298-305
    • /
    • 2021
  • Modern distance sensing methods employ various measurement principles, including triangulation, time-of-flight, confocal, interferometric and frequency comb. Among them, the triangulation method, with a laser light source and an image sensor, is widely used in low-cost applications. We developed an omnidirectional two-dimensional (2D) distance sensor based on the triangulation principle for indoor floor mapping applications. The sensor has a range of 150-1500 mm with a relative resolution better than 4% over the range and 1% at 1 meter distance. It rotationally scans a compact one-dimensional (1D) distance sensor, composed of a near infrared (NIR) laser diode, a folding mirror, an imaging lens, and an image detector. We designed the sensor layout and configuration to satisfy the required measurement range and resolution, selecting easily available components in a special effort to reduce cost. We built a prototype and tested it with seven representative indoor wall specimens (white wallpaper, gray wallpaper, black wallpaper, furniture wood, black leather, brown leather, and white plastic) in a typical indoor illuminated condition, 200 lux, on a floor under ceiling mounted fluorescent lamps. We confirmed the proposed sensor provided reliable distance reading of all the specimens over the required measurement range (150-1500 mm) with a measurement resolution of 4% overall and 1% at 1 meter, regardless of illumination conditions.