복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구 (A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries)

  • 장지성;최원근;정재연;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

다목적 홀에서의 프론트필 스피커의 필요성 (The need of Front-fill Speaker in the Multipurpose Hall)

  • 송덕근;강준상;노정규;이선희
    • 한국위성정보통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.43-46
    • /
    • 2013
  • 영상을 적극적으로 사용하는 종교 시설과 같은 장소에서는 스크린 높이에 따라 메인 스피커의 높이가 결정된다. 이로 인해 '음상불일치'와 '저음부스팅'과 같은 음향 장애 요인이 발생하여 시각적으로 좋은 자리인 앞 좌석이 음향적으로는 좋지 않은 장소가 되고 만다. 이러한 음향적 장애를 최소화하기 위해서는 프론트필(Front-fill) 스피커를 적극적으로 도입할 필요가 있으며, 스크린 때문에 높아진 메인 스피커와의 거리 및 음압 차이에 따라 적합한 용량을 결정해야 한다. 프론트필 스피커를 적극적으로 사용하여 음상일치(音像一致)를 구현함으로써 음의 집중도를 높이고, 고음(高音) 유입이 상대적으로 부족한 앞좌석에 중고음을 보강하여 주파수 응답을 고르게 구현할 수 있다. 멀티미디어 환경에서 주요 좌석인 앞쪽 열에 메인 스피커의 부족한 부분을 보완하여 더 쾌적한 음향 환경을 구현하기 위해 프론트필 스피커를 적극적으로 도입할 필요가 있으며, 이에 대한 구체적인 기준안 제시가 필요하다.

멀티미디어 환경에서 언더발코니 스피커의 역할 (The role of Under-balcony Speaker in the Multimedia Environmental)

  • 송덕근;박은진;이선희
    • 한국위성정보통신학회논문지
    • /
    • 제10권2호
    • /
    • pp.86-89
    • /
    • 2015
  • 복층이 있는 공간의 음향 특성을 계산식, 시뮬레이션 및 실측을 통해 비교해 보았다. 언더발코니 스피커의 바로 뒤 지역은 메인스피커와 딜레이 차이가 생기며, 중/저음 부분에서 충분한 음압저하가 이뤄지지 않아 컴필터링(Comb-Filtering) 현상이 크게 발생하게 된다. 또한 언더발코니 스피커의 바로 하부 지역은 스피커와 거리가 2~3m 내외로 언더발코니 스피커의 음압이 메인 스피커보다 커져 강대상과 음상일치가 깨지게 된다. 언더발코니 스피커에서 5~6m 이상 벗어나는 지역은 음의 역자승법칙에 따라 언더발코니 스피커 하부 지역보다 10dB이상 차이가 발생하며, 메인스피커에서도 중/고역 주파수(Mid/High Frequency) 음이 유입되지 않아 주파수별 음압 편차가 크게 발생하여 집중도가 떨어지게 된다. 이러한 음향 문제를 최소화하기 위해서 메인스피커의 위치 및 출력에 따른 언더발코니 스피커의 적절한 배치와 출력이 요청된다. 발코니 하부 지역을 더 쾌적한 음향 환경으로 개선하기 위해서는 언더발코니 스피커에 대한 적절한 음향설계 방향이 제시되어야 한다.

자궁경부암의 강내치료를 위한 선량측정 (Dose Distribution&Calibration in HDR Intracavitary Irradiation for Uterine Cervical Cancer)

  • 김진기;김정수;김형진;권형철
    • 한국의학물리학회지:의학물리
    • /
    • 제6권1호
    • /
    • pp.13-18
    • /
    • 1995
  • 고선량의 RALS(Remote Afterloding Syetem)를 이용한 근접조사에서 선원의 위치에 따라 선량분포는 거리제곱의 반비례 형태로 변화되므로, 관심점의 흡수선량은 선원의 교정에 의해 크게 영향을 받는다. 자궁경부암 강내치료시 정확한 흡수선량을 결정하고자 선원을 교정하고, 선원의 위치에 따른 선량분포도에 의한 계산값과 반도체 검출기와 전리함을 이용한 설측값과 차이를 비교하고 보정 방법을 논의 하였다. Bulcher-RALS를 이용하여 치료에 사용된 선원의 교정은 공기커마와 사각형 아크랄 팬톰을 이용하여 r 인자에 의한 거리 역자승법칙으로 계산하였고, Co-60 선원의 8cm 거리에서 검교정된 측정기를 이용한 선량율을 비교치로 이용하였다. 선량측정치의 재현성은 팬톰내에서 0.3~1.1% 였으며, 측정치의 분포는 Bulcher-RALS 선량분포도에 의한 계산값과 팬톰측정치의 비교에서 -3~17%, 강내치료를 받은 18 명의 환자를 대상으로한 직장내 흡수선량에서 체내 실측값과 차이는 환자와 선원의 위치에 따라 -6~+21%로 측정값이 평균 6.3% 높게 나타났다.

  • PDF

전자선 에너지 및 조사야에 따른 유효선원 피부 간 거리 변화 (Variation of Effective SSD According to Electron Energies and Irradiated Field Sizes)

  • 양칠용;염하용;정태식
    • Radiation Oncology Journal
    • /
    • 제5권2호
    • /
    • pp.157-163
    • /
    • 1987
  • It is known that fixed source to skin distance (SSD) cannot be used when the treatment field is sloped or larger than the size of second collimator in electron beam irradiation and inverse square law using effective ssd should be adopted. Effective SSDs were measured in different field sizes in each 6, 9, 12, 15 and 18MeV electron energy by suing NELAC 1018D linear accelerator of Kosin Medical Center. We found important parmeters of effective SSD. 1. Minimum effective SSD was 58.8cm in small field size of $6\pm6cm$ and maximum effective SSD was 94.9cm in large field size of $25\pm25cm$, with 6MeV energy. It's difference was 36.1cm. The dose rate at measuring point was quite different even with a small difference of SSD in small field $(6\times6cm)$ and low energy (6 MeV). 2. Effective SSD increased with field size in same electron energy. 3. Effective SSDs gradually increased with the electron energies and reached maximum at 12 or 15 MeV electron energy and decreased again at 18MeV electron energy in each identical field size. And so the effective SSD should be measured in each energy and field size for practical radiotherapy.

  • PDF

단순화 이선원 모델을 이용한 전자선 선량율 계산 알고리듬에 관한 예비적 연구 (A Feasibility study on the Simplified Two Source Model for Relative Electron Output Factor of Irregular Block Shape)

  • 고영은;이병용;조병철;안승도;김종훈;이상욱;최은경
    • 한국의학물리학회지:의학물리
    • /
    • 제13권1호
    • /
    • pp.21-26
    • /
    • 2002
  • 블록을 사용한 부정형 전자선 조사면에서의 선량율(relative output factor, ROF)을 계산하는 전자선 알고리듬을 개발하고, 측정값과 계산값을 비교하여 알고리듬을 평가하였다. 전자선의 선량은 산란판, 전자선 cone 등 모든 요소를 고려한 1차선 부분과 블럭에 의한 2차선의 합으로 표시할 수 있다고 가정하였으며, 1차선은 가우스 분포를, 2차선은 거리역제곱 법칙만을 따른다고 가정하였다. 2차선 블럭 산란에 의한 각 분포는 고려하지 않았다. 이런 방법으로 전자선의 ROF를 유효 SSD, 1차선 분포 표준편차, 2차선 발생율 등 3가지의 인자만을 이용하여 선량율을 계산할 수 있는 단순한 방식을 고안하였다. 6, 9, 12, 16, 20 MeV의 전자선을 사용하여 이 모델을 검증하였다. 측정은 항상 개방 조사면의 선량 최대지점 깊이에서 실시하였으며 다양한 정사각형 치료면 측정으로 3개의 인자를 구할 수 있었다 직사각형 조사면과 부정형 조사면에 대하여 이 모델을 이용한 계산값과 측정값의 차이는 평균 1.0%이내였으며, 최대 2.1%를 넘지 않았다. 본 연구에서 개발한 알고리듬은 필요한 인자가 3개이면서 매 전자선 콘마다 5∼6회 측정으로 구할 수 있어서 임상 적용에 편리하며, 계산 결과가 정확하여 특이 오차를 보이는 유형에 관한 보완 연구를 수행하면 임상에 사용할 수 있음을 보였다.

  • PDF

표준계수 측정 시 기하학적 요인이 방사성 요오드 갑상선 섭취율에 미치는 영향 (The Effect of Geometric Factors When Measuring Standard Count for Radioactive Iodine Thyroid Uptake Rate)

  • 오주영;김정열;오기백;오신현;김재삼;이창호;박훈희
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.53-61
    • /
    • 2013
  • 방사성 요오드 갑상선 섭취율은 거대갑상선 환자의 경우 그 체적에 의한 유효 갑상선 깊이가 깊어짐으로 인한 기하학적 변동이 있는 것이 사실이다. 본 연구는 방사성 요오드갑상선 섭취율에 있어 검출기와 선원 간 거리와 유효 갑상선 깊이에 따른 기하학적 요인의 영향을 고찰하고자 하였다. $^{131}I$ 370 kBq 선원을 검출기로부터 거리를 20 cm부터 30cm까지 1 cm 간격으로 변화시키며 Captus 3000 thyroid uptake system(Capintec, NJ, USA)으로 측정하였다. 유효갑상선 깊이를 재현하기 위해 목 팬텀을 이용하여 팬텀 내 선원의 깊이를 1 cm, 2 cm, 5 cm으로 변화시키며 같은 방법으로 측정하였다. 실험 결과, 곡선추정 회귀분석 결과 모든 실험군이 거듭제곱곡선에 높은 상관관계를 보이는 것으로 나타났다($$R2{\geq_-}0.915$$). 그러므로 검출기-선원 간 거리가 20 cm보다 30 cm에서 오차가 크게 감소됨을 예상할 수 있다. 모든 실험군에서 팬텀을 쓰지 않았을 때와 유효 갑상선깊이가 1 cm이 적용되었을 때의 계수율이 서로 유의할 만한 차이가 있는 것으로 나타났다(p<0.01). 선형회귀분석 결과 깊이에 따른 계수율의 변화는 모두 감소되는 것으로 나타났으나,$284.3keV{\pm}10%$ 영역에서 깊이에 따른 계수율의 변화는 증가되는 것으로 나타났다. 이 회귀식을 통해 환자의 예상 갑상선 섭취율을 산출해 보았을 때, $364.4keV{\pm}10%$에서 1 cm 당 -6.42%, $364.4keV{\pm}20%$의 영역에 서 -5.09%의 더 낮은 오차를 보였다. 또한 거리에 따른 계수율의 변동계수는 모든 실험군에서 선형으로 증가되는 것으로 나타났다. 그 중 $364.4keV{\pm}20%$, $364.4keV{\pm}10%$ 영역은 비교적 낮은 변동계수와 증가폭을 보였다. 곧, 유효 갑상선 깊이에 따른 오차를 줄이기 위해서는 $364.4keV{\pm}20%$의 영역의 사용이 더 적절할 것으로 보인다. 그러므로 갑상선 깊이에 따른 오차는 갑상선 깊이에 따른 보정계수 적용,$364.4keV{\pm}20%$ 에너지 영역 설정, 디텍터와 선원과의 거리를 연장하였을 때 감소시킬 수 있다고 생각된다.

  • PDF

방사선근접치료 분야의 선량 측정을 위해 제조된 Lead(II) Iodide 선량계의 적용가능성 연구 (The Study on Applicability of Manufactured Lead(II) Iodide Dosimeter for Dose Measurement in Brachytherapy)

  • 양승우;한무재;박성광
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.789-794
    • /
    • 2021
  • 근접방사선치료는 방사선동위원소를 신체 내부에 넣어 종양에 방사선을 집중적으로 조사하는 치료법이다. 근접방사선 치료는 고선량율의 방사선동위원소 선원을 사용하기 때문에 정확한 선원의 위치 및 선량등을 파악하는 것이 매우 중요하다. 하지만 임상에서는 ruler, autoradiograph등을 통하여 육안으로 부정확하게 평가하는 실정이다. 이에 본 연구에서는 Lead(II) Iodide(PbI2) 물질을 사용하여 방사선근접치료에 사용할 수 있는 선량계를 개발하고, 재현성, 선형성, PID 항목을 분석하여 적용가능성을 평가하였다. 재현성 평가 결과, RSD 값은 1.41%로 평가기준 1.5%를 만족하였다. 선형성 평가결과, R2값은 0.9993으로 평가기준 0.9990을 만족하였다. PID 평가 결과 50% 선량 감약지점에서 거리의 역자승 법칙의 이론값과 비교하여 0.06 cm의 차이만을 나타내었다. 본 실험에서 제작된 선량계는 모든 평가에서 기준치를 만족하는 결과값을 나타내어 방사선근접치료 영역에서의 선량계 적용 가능성이 충분한 것으로 판단된다.

방사성동위원소를 이용한 비파괴 검사 시 작업환경 내 공간선량률 평가 (Evaluation of Spatial Dose Rate in Working Environment during Non-Destructive Testing using Radioactive Isotopes)

  • 조용인;김정훈;배상일
    • 한국방사선학회논문지
    • /
    • 제16권4호
    • /
    • pp.373-379
    • /
    • 2022
  • 비파괴 검사에 사용되는 방사선원은 투과력이 높고 주변 물질과의 충돌을 통해 산란선을 야기하며 이는 주변 공간선량 변화를 발생시킨다. 이에 본 연구는 몬테카를로 모의 모사를 활용하여 비파괴 검사 시 작업환경 내 선원별 공간선량 분포를 평가 및 분석하고자 하였다. 본 연구는 모의 모사 코드인 FLUKA를 활용하여 비파괴 검사에서 사용되는 60Co(3,700 GBq), 192Ir(1,850 GBq), 75Se(2,960 GBq) 선원을 모의모사하고, 산출된 선량률을 보건물리학회 자료와 비교하여 선원항의 신뢰성을 확보하였다. 이후 방사선안전시설(RT-room) 내 비파괴 검사를 설계하여 선원으로부터 거리에 따른 공간선량률을 평가하였다. 공간선량률 평가 결과, 75Se 선원이 정면 위치에서 가장 낮은 선량 분포를 보였으며, 60Co는 75Se에 비해 약 15배, 192Ir 보다 약 2배 높은 선량을 나타내었다. 또한 거리에 따른 공간선량 분포는 선원과의 거리가 증가할수록 거리 역자승 법칙에 따라 감소되는 경향을 나타내었다. 예외적으로 60Co, 192Ir, 75Se 선원 모두 2 m 지점 이내에서 선량이 다소 증가하는 것을 확인하였다. 방사성동위원소를 이용한 비파괴 검사 시 작업환경 내 피폭선량 관리를 위해 75Se 선원과 같은 낮은 에너지를 방출하는 선원의 사용과 작업 시 방사선안전시설 내 선원과의 거리를 4 m 이상으로 유지한다면, 방사선작업종사자의 피폭선량 최적화에 도움 될 것으로 판단된다. 추후 본 연구 결과를 토대로 비파괴 검사 시 방사선안전시설 내 종사자의 안전관리를 위한 보조자료로서 활용될 것으로 사료된다.