• 제목/요약/키워드: distal

검색결과 3,256건 처리시간 0.029초

The Effect of Distal Aortic Pressure on Spinal Cord Perfusion in Rats

  • Park, Sung-Min;Cho, Seong-Joon;Ryu, Se-Min;Lee, Kyung-Hak;Kang, Gu
    • Journal of Chest Surgery
    • /
    • 제45권2호
    • /
    • pp.73-79
    • /
    • 2012
  • Background: Aortic cross clamping is associated with spinal cord ischemia. This study used a rat spinal cord ischemia model to investigate the effect of distal aortic pressure on spinal cord perfusion. Materials and Methods: Male Sprague-Dawley rats (n=12) were divided into three groups. In group A (n=4), the aorta was not occluded. In groups B (n=4) and C (n=4), the aorta was occluded. In group B the distal aortic pressures dropped to around 20 mmHg. In group C, the distal aortic pressure was decreased to near zero. The carotid artery and tail artery were cannulated to monitor the proximal aortic pressure and the distal aortic pressure. Fluorescent microspheres were used to measure the regional blood flow in the spinal cord. Results: After aortic occlusion, blood flow to the cervical spinal cord showed no significant difference among the three groups. In groups B and C, the thoracic and lumbar spinal cord and renal blood flow decreased. No microspheres were detected in the thoracic and lumbar spinal cord of group C. Conclusion: The spinal cord blood flow is dependent on the distal aortic pressure after thoracic aortic occlusion.

Mini Wrap-around 유리 피판술을 이용한 무지 원위부 재건술 (Microsurgical Distal Thumb Reconstruction Using a Mini Wrap-around Free Flap)

  • 권기두;안병문;여용범
    • Archives of Reconstructive Microsurgery
    • /
    • 제17권2호
    • /
    • pp.101-107
    • /
    • 2008
  • Purpose: Free flaps from the great toe are an established method for reconstruction of absent or partially amputated thumbs. However, options differ as to which technique represents the ideal solution for each level of amputation. Various methods of distal thumb reconstruction have been proposed. We prefer to transplant the entire great toe nail complex with the almost all of the pulp rather than a portion of the nail. This paper reflects our experience in using the great toe mini wrap-around flap for distal thumb reconstruction. Materials and Methods: In the period from October of 2005 to July of 2007, 9 patients were treated for traumatic thumb defects localized at the distal phalanx of the thumb. The patients included seven men and two women. The mean age was 44 years (range, 21~60) and the dominant right hand was involved in seven of nine patients. Results: The transferred flaps have survived completely in all cases. The mean range of motion in the interphalangeal joints was 51o, with 73% of the normal uninjured opposite hands. The two-point discrimination was 10.5 mm (range, 5~13 mm). In Semmes-Weinstein monofilament test, the sensibility was 4.31 in 4 cases, 3.61 in 3 cases and 2.83 in 2 cases. The pinch power was 64% (range, 55~95%) of the opposite hand. All patients were satisfied with the appearance of the reconstructed thumb and felt comfortable at final follow-up. Conclusion: We have successfully reconstructed 9 cases of traumatic distal thumb defects using the mini wrap-around free flap. The mini wrap-around free flap in great toe is an excellent alternative method for distal thumb reconstruction in selected patients.

  • PDF

하악전돌환자의 하악지시상분할골절단술 후의 원심골편의 후방경계의 골흡수에 대한 연구 (A STUDY OF BONE RESORPTION AT THE POSTERIOR BORDER OF DISTAL SEGMENT AFTER BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY OF MANIBULAR PROGNATHIC PATIENTS)

  • 이용인;임종환;노광섭;홍종락;전주홍;김창수
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권1호
    • /
    • pp.55-59
    • /
    • 2005
  • Purpose : This study is to predict the changes of the distal segment by investing the resorption of the excessive distal segment regarding the amount of setback after BSSRO. Material and Methods : 20 patients with Mandible prognathism treated by Obwegeser-Dal Pont method during the years 2000 to 2002 were selected for this study. Group A consisted of 5 males & 5 females with a setback amount of 10mm and above(Mean $10.80mm{\pm}1.03$, n=20) and Group B consisted of 2 males & 8 females with a setback amount of below 10mm.(Mean $6.10mm{\pm}1.10$, n=20) Panorama X-ray was taken at day 1, 1month, 3months, 6months, and 12months after the surgery. Resorption areas of excessive distal segment were measured on these panorama X-rays and compared. Results : There was bone resorption in both groups. Group A showed more bone resorption than Group B. Group B showed slightly higher resorption rate than Group A. However, there was no statistically significant difference between the resorption rates of Group A and Group B. (P>0.05). Conclusion : More bone resorption occurred with a larger amount of setback and about one third of the excessive distal segment underwent resorption, irrespective of the amount of setback.

심각한 외측 회전을 동반한 전완 기형의 외과적 교정 치료 2 증례 (Surgical Correction of an Antebrachial Deformity with Severe External Rotation in Two Dogs)

  • 윤헌영;노미영;정순욱
    • 한국임상수의학회지
    • /
    • 제28권3호
    • /
    • pp.328-331
    • /
    • 2011
  • 간헐적 전지 파행을 보이는 두 마리 개가 내원하였다. 신체 검사에서 약 $90^{\circ}$ 외측 회전을 동반한 전완 기형을 두 마리 모두에서 확인 하였다. 일반 방사선 사진에서 척골 원위부 아탈구, 요골 앞쪽 휨 현상, 짧아진 요골 척골, 및 앞발의 외측 회전을 확인하였다. 외측 회전을 동반한 전완 기형의 교정을 위해 척골 원위부 골절제와 요골 원위부 쐐기형 절골술 및 요골 원위부 내측 회전을 실시 하였다. 관절 부조화를 예방하기 위해 척골 근위부 절골술을 첫 번째 개에서 실시 하였다. 수술 후 정기 검진은 수의사의 신체 검사를 통해 실시 되었으며 두 마리 모두에서 수술과 관련한 합병 증상 및 파행이 없음을 확인하였다.

Cone beam형 전산화단층촬영장치를 이용한 하악 제1대구치 근심 치근의 danger zone에 관한 연구 (Evaluation of danger zone in mesial root of mandibular first molar by cone beam computed tomography (CBCT))

  • 장유리;최용석;최기운;박상혁
    • Imaging Science in Dentistry
    • /
    • 제37권2호
    • /
    • pp.103-110
    • /
    • 2007
  • Purpose: To examine the danger zone of mesial root of mandibular first molar of patient without extraction using CBCT (cone-beam computed tomography) to avoid the risk of root perforation. Materials and Methods: 20 mandibular first molars without caries and restorations were collected, CT images were obtained by CBCT ($PSR9000N^{TM}$, Asahi Roentgen Co., Japan), reformed and analyzed by V-work 5.0 (CyberMed Inc., Korea), Distance between canal orifice and furcation was measured. In cross sectional images at 3, 4 and 5 mm below the canal orifice, distal wall thickness of mesiobuccal canal (MB-D), distal wall thickness of mesiolingual canal (ML-D), distal wall thickness of central part (C-D), mesial wall thickness of mesiobuccal canal (MB-M) and mesial wall thickness of mesiolingual canal (ML-M) were measured, Results: The mean distance between the canal orifice and the furcation of the roots is 2.40 mm, Distal wall is found to be thinner than mesial wall. Mean dentinal wall thickness of distal wall is about 1 mm, The wall thickness is thinner as the distance from the canal orifice is farther. But significant differences are not noted between 4 mm and 5 mm in MB-D and C-D, MB-D is thinner than ML-D although the differences is not significant. Conclusion: The present study confirmed the anatomical weakness of distal surface of the coronal part of the mesial roots of mandibular first molar by CBCT and provided an anatomical guide line of wall thickness during endodontic treatment.

  • PDF

Linear-Shaped Gastroduodenostomy in Totally Laparoscopic Distal Gastrectomy

  • Son, Hyaung-Mi;Lee, Sang-Lim;Hur, Hoon;Cho, Yong-Kwan;Han, Sang-Uk
    • Journal of Gastric Cancer
    • /
    • 제10권2호
    • /
    • pp.69-74
    • /
    • 2010
  • Purpose: Laparoscopic gastrectomy has been common treatment modality for gastric cancer. But, most surgeons tend to perform laparoscopy-assisted distal gastrectomy using epigastric incision. Delta-shaped anastomosis is known as intracorporeal gastroduodenostomy, but it is technically difficult and needed many staplers. So we tried to find simple and economical method, here we report on the results of liner-shaped gastroduodenostomy in totally laparoscopic distal gastrectomy. Materials and Methods: We retrospectively reviewed the medical records of 25 patients who underwent totally laparoscopic distal gastrectomy using liner-shaped anastomosis at School of Medicine, Ajou University between January to October 2009. The indication was early gastric cancer as diagnosed by preoperative workup, the anastomoses were performed by using laparoscopic linear stapler. Results: There were 12 female and 13 male patients with a mean age of $55.6{\pm}11.2$. The following procedures were performed 14 laparoscopic gastrectomies, 11 robotic gastrectomies. The mean operation time was $179.5{\pm}27.4$ minutes, the mean anastomotic time was $17.5{\pm}3.4$ minutes. The mean number of stapler cartridges was $5.6{\pm}0.8$. Postoperative complication occurred in one patient, anastomotic stenosis, and the patient required reoperation to gastrojejunostomy. The mean length of postoperative hospital stay was $6.7{\pm}1.0$ days except the complication case, and there was no case of conversion to open procedure and postoperative mortality. Conclusions: Linear-shaped gastroduodenostomy in totally laparoscopic distal gastrectomy is technically simple and feasible method.

손가락끝 손상의 치료 시 인조손톱의 유용성 (The Usefulness of the Artificial Nail for Treatment of Fingertip Injuries)

  • 최환준;권준성;탁민성
    • Archives of Plastic Surgery
    • /
    • 제37권6호
    • /
    • pp.788-794
    • /
    • 2010
  • Purpose: The fingertip is the most commonly injured part of the hand and its injury frequently results in avulsion or crushing of a segment of the nail bed and fracture of the distal phalangeal bone. Restoration of a flat and smooth nail bed is essential for regrowth of a normal nail, which is important not only for cosmetic reasons but also for tactile capability of the fingertip. It is also anatomical reduction of the distal phalanx to promote patient's cosmetics and prevent nail bed deformity. Absence or no replacement of the nail plate results in obliterated proximal skin fold. When the avulsed nail plate cannot be returned to its anatomic position or when it is absent, we use a synthetic material for splinting the nail bed and alternative reductional method for distal phalangeal bone fracture, especially, instead of hardwares. Methods: From January of 2006 to June of 2009, a total of ten patients and fourteen fingers with crushing or avulsion injuries of the fingertip underwent using the artificial nails for finger splint. We shaped artificial nails into the appropriate sizes for use as fingernail plates. We placed them under the proximal skin fold and sutured to the fold proximally and to the lateral and medial edges of the nail bed or to the distal fingertip. Our splints were as hard as K-wire and other fixation methods and more similar to anatomic nail plates. Artificial nails were kept in place for at least 3 weeks. Results: No artificial nail related complication was noted in any of the ten cases. No other nail fold or nail bed complications were observed, except for minor distal nail deformity because of trauma. Conclusion: In conclusion, in order to secure the nail bed after injury and reduce the distal phalangeal bone fracture, preparing a nail bed splint from a artificial commercial nail is a cheap and effective method, especially, for crushed or avulsion injuries of the fingertip.

Multi-slit prompt-gamma camera for locating of distal dose falloff in proton therapy

  • Park, Jong Hoon;Kim, Sung Hun;Ku, Youngmo;Kim, Chan Hyeong;Lee, Han Rim;Jeong, Jong Hwi;Lee, Se Byeong;Shin, Dong Ho
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1406-1416
    • /
    • 2019
  • In this research, a multi-slit prompt-gamma camera was developed to locate the distal dose falloff of the proton beam spots in spot scanning proton therapy. To see the performance of the developed camera, therapeutic proton beams were delivered to a solid plate phantom and then the prompt gammas from the phantom were measured using the camera. Our results show that the camera locates the 90% distal dose falloff (= d90%), within about 2-3 mm of error for the spots which are composed $3.8{\times}10^8$ protons or more. The measured location of d90% is not very sensitive to the irradiation depth of the proton beam (i.e., the depth of proton beam from the phantom surface toward which the camera is located). Considering the number of protons per spot for the most distal spots in typical treatment cases (i.e., 2 Gy dose divided in 2 fields), the camera can locate d90% only for a fraction of the spots depending on the treatment cases. However, the information of those spots is still valuable in that, in the multi-slit prompt-gamma camera, the distal dose falloff of the spots is located solely based on prompt gamma measurement, i.e., not referring to Monte Carlo simulation.

Risk Factors for the Development of Incisional Hernia in Mini-laparotomy Wounds Following Laparoscopic Distal Gastrectomy in Patients with Gastric Cancer

  • Jang, Eun Jeong;Kim, Min-Chan;Nam, So-Hyun
    • Journal of Gastric Cancer
    • /
    • 제18권4호
    • /
    • pp.392-399
    • /
    • 2018
  • Purpose: To determine the incidence of incisional hernia (IH) in mini-laparotomy wounds and analyze the risk factors of IH following laparoscopic distal gastrectomy in patients with gastric cancer. Materials and Methods: A total of 565 patients who underwent laparoscopic distal gastrectomy for gastric cancer at Dong-A University Hospital, Busan, South Korea, between June 2010 and December 2015, were enrolled. IH was diagnosed through physical examination or computed tomography imaging. Incidence rate and risk factors of IH were evaluated through a long-term follow-up. Results: Of those enrolled, 16 patients (2.8%) developed IH. The median duration of follow-up was 58 months (range, 25-90 months). Of the 16 patients with IH, 15 (93.7%) were diagnosed within 12 months postoperatively. Multivariate analysis showed that female sex (odds ratio [OR], 3.869; 95% confidence interval [CI], 1.325-11.296), higher body mass index (BMI; OR, 1.229; 95% CI, 1.048-1.422), and presence of comorbidity (OR, 3.806; 95% CI, 1.212-11.948) were significant risk factors of IH. The vast majority of IH cases (15/16 patients, 93.7%) developed in the totally laparoscopic distal gastrectomy (TLDG) group. However, the type of surgery (i.e., TLDG or laparoscopy-assisted distal gastrectomy) did not significantly affect the development of IH (P=0.060). Conclusions: A median follow-up of 58 months showed that the overall incidence of IH in mini-laparotomy wounds was 2.8%. Multivariate analysis showed that female sex, higher BMI, and presence of comorbidity were significant risk factors of IH. Thus, surgeons should monitor the closure of mini-laparotomy wounds in patients with risk factors of IH undergoing laparoscopic distal gastrectomy.

The Radiologic Comparison of Operative Treatment Using a Hook Plate versus a Distal Clavicle Locking Plate of Distal Clavicle Fracture

  • Yoon, Byungil;Kim, Jae Yoon;Lee, Jae-Sung;Jung, Hyoung Seok
    • Clinics in Shoulder and Elbow
    • /
    • 제21권4호
    • /
    • pp.227-233
    • /
    • 2018
  • Background: The purpose of this study was to compare the radiologic results of patients who underwent surgery with a hook plate and a locking plate in distal clavicle fractures. Methods: Sixty patients underwent surgical treatment for Neer type IIa, IIb, III, and V distal clavicle fracture. Twenty-eight patients underwent fracture fixation with a hook plate and 32 with a locking plate. Coracoclavicular distance was measured on standard anteroposterior radiographs before and after the surgery, and union was confirmed by radiograph or computed tomography taken at 6 months postoperatively. Other radiologic complications like osteolysis was also checked. Results: Bony union was confirmed in 59 patients out of 60 patients, and 1 patient in the hook plate group showed delayed union. Coracoclavicular distance was decreased more in the hook plate group after surgery (p<0.01). After 6 weeks of the hook plate removal, the coracoclavicular distance was increased a little compared to before metal removal, but there was no difference compared to the contralateral shoulder. Eleven out of 28 patients (39.3%) showed osteolysis on the acromial undersurface in the hook plate group. Conclusions: Both the hook plate group and the locking plate group showed satisfactory radiologic results in distal clavicle fractures. Both hook plate and locking plate could be a good treatment option if it is used in proper indication in distal clavicle fracture with acromioclavicular subluxation or dislocation.