Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

Changes in Centration of Contact Lenses on Cornea and Blink Rate Associated with Overusage of Disposable Lenses (일일 착용 렌즈의 착용기간 초과시 유발되는 렌즈의 중심 안정 위치 및 순목횟수 변화)

  • Park, Mijung;Yang, Jae Heon;Kim, Sun Mi;Park, Sang-Il;Park, Sang Hee;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.51-58
    • /
    • 2008
  • Purpose: This study was assessed to investigate adverse effect induced by overuse of disposable soft contact lenses (CL). Methods: Three disposable lenses (etafilcon A, hilabilcon A, and nelfilcon A) were applied to 19 normal subjects free from any eye diseases for either a single day or variable periods by when subjects complained any discomforts. On the first and last days, localizations of lens' center on corneal surface and blink rates were recorded at every case. Results: Among CL wearers, 10.5% and 47.4% of total subjects quit wearing on the second day and third day, respectively. The case of stopping disposable lens wear was continuously increased with extended hour of lens application. On fourth day, 70.2% of CL wearers reported severe discomforts such as redness, dryness, irritation, pain and blurred vision. When subjects stopped CL wear, decentration of lens from the center of cornea was observed when it compared to the case of single usage of disposable CL. Also about 80% of total subjects showed increased blink rate when CL were worn for more than 2 days. These changes in lens centration and blink rate were consistantly shown regardless of lens types. Conclusions: Blurred vision and acute/chronic discomforts could occur to CL wearers by decentration of lens and increased blink rate when CL were overused more than 2 days even the numbers of two parameters measured in this study were variable by each subject or lens types. Therefore, consideration of individual characteristics and lens types is critical to prevent adverse effects may induced by overusage of disposable lens.

  • PDF

Changes in Subjective/Objective Symptoms and the Light Transmissibility of Lens Associated with Overusage of Daily Disposable Circle Contact Lenses in Normal Eyes (일회용 써클소프트렌즈의 초과 착용에 의한 정상안의 자·타각적 증상 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kwon, Hae Lim;Choi, Sae Ah;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2013
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmissibility of lens caused by over-usage of daily disposable circle contact lenses (circle lens). Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 20 normal eyes free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, non-invasive break-up time, lens centration on corneal surface and visible light transmissibility of lens were recorded at every case and compared. Results: The circle lens wearers complained discomfort when they wore the circle lens more than 15 hours, in excess of 8 hours being the recommended wearing time and the most circle lens wearers quit the lens wearing when they wore more than 30 hours. On the last day of lens wearing, the representative subjective discomforts were stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, a tendency of increased blinking rate and decreased NIBUT was observed when it compared with the values right after lens wearing. On the last day of lens wearing, the lens centration was shown to be decentrated from the pupil center compared with the centration right after the wearing. These changes in lens centration and blinking rate were consistently shown in all cases of lens wearing however, the difference in the degree of subjective and/or objective change was present depending on lens materials and subjects. The visible light transmissibility of circle lens has largely been changed. Conclusions: From these results, it was thought that the decreased NIBUT induced dryness and stiffness and decreased visible light transmissibility caused more blinking when daily disposable circle lens was exceedingly used, which provoked lens decentration and subjective discomfort. However, the difference of subjective and/or objective change was largely varied in accordance with the lens material types and individuality and thus it may occur some unexpected problems by the individual base. Therefore, the education about the necessity to comply with the recommended wearing time and the problem will be essential.

Comparison of In Vitro Lipid Deposition and Change of Optical Characteristics on Daily Disposable Lenses (1-day) and 3-days Lenses Over 3 days (3-days lenses와 daily disposable lenses(1-day)의 착용 시간 별 지방 침착량 및 광학적 특성 변화의 비교)

  • Song, Sun Jung;Lee, Su Yeon;Kim, Ki Hong;Chu, Byoung Sun
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.2
    • /
    • pp.67-73
    • /
    • 2020
  • The study aimed to investigate in vitro lipid deposition of oleic acid, oleic acid methyl ester and cholesterol on a daily disposable (1-day lenses) and 3-days lenses over 3 days and changes of optical characteristics is also investigated. Artificial tear solutions were prepared to simulate actual tear compositions. Two types of contact lenses (1-day lenses (Senofilcon A) and 3-days lenses (silicone tripolymer)) were soaked in the artificial tear solutions within an incubator at 37 ℃ with 150 rpm for 8, 16, 24 hours. Lipid deposition (oleic acid, oleic acid methyl ester and cholesterol) were measured using high performance liquid chromatography (HPLC) instrument. In addition, measurements of oxygen transmissibility, light transmittance and observation of lens surface were conducted. The amount of lipid deposition on the 1-day lenses were 127.55 ㎍/lens for Day 1, 302.96 ㎍/lens, for Day 2, and 353.30 ㎍/lens for Day 3. The 3-days lenses were 46.22 ㎍/lens for Day 1, 66.07 ㎍/lens for Day 2, and 67.45 ㎍/lens for Day 3. Oxygen transmissibility were 81×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 48×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 1-day lenses, it were 13.23×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 9.6×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 3-days lenses. Transmittance of each lenses were 97.21% (Baseline) and 94.25% (Day 3) for the 1-day lenses, 97.65% (Baseline) and 95.15% (Day 3) for the 3-days lenses. Observation of surface deposition indicated greatest deposition for the 3-days lenses type on Day 3. Lipid deposition for both lens types increased by day and was greater for the 1-day lenses type. Surface deposition appeared to differ as it was greatest for the 3 days lens type, which may suggest other deposits such as protein may be present.

Microorganism Contamination from Wearing One-Day Disposable Contact Lenses According to Wearing Time (일일 착용 콘택트렌즈의 연속 착용에 따른 세균 오염)

  • Choi, Gang-Won;Jang, Woo-Yeong;Lee, Jong-Wook;Kim, Su-Jung
    • Korean Journal of Microbiology
    • /
    • v.46 no.2
    • /
    • pp.152-156
    • /
    • 2010
  • Disposable contact lenses, which are one type of soft contact lenses, provide convenience in use, but also cause various ocular infectious diseases. Microorganisms that cause eye diseases include Acanthamoeba, bacteria, Fungi, and so on. It is impossible to prevent microorganism contamination completely due to the use of hands as wearing contact lenses. The contamination by various microorganisms leads to infectious keratitis, but it is not well known for the exact microorganisms that affect the disease. For this reason, to identify the microorganisms, two groups that are commonly used for disinfection of lenses were divided: normal saline solution and multiple purpose solution. Using these solutions the degree of microorganism contamination was observed according to the days of 1, 3, 5, 10, and 15. Twenty students by two groups from Ophthalmic Optics department at D college in Daegu Metropolitan city participated in the experiment after their ocular health conditions were checked. During they wore one-day disposable lenses for 1, 3, 5, 10, and 15 days, bacteria were cultured in media. The results, which were Gram stained by selecting the cultured colonies, show as followings: Gram positive cocci 33%, Gram-negative cocci 2%, Gram positive bacilli 34%, and the Gram negative bacilli 31%, respectively. As for the identification of potential pathogens, VITEK system and API kit methods were used. Keratitis caused by bacteria known as Staphylococcus aureus, Pseudomonas aeruginosa were detected as a result of wearing contact lenses. This study examined the distribution of bacteria as wearing one-day disposable contact lenses and pathogenic bacteria according to the duration of wearing them. In conclusion, the importance of hygiene when using contact lenses is suggested.

Change of Spherical Aberration with Aspheric Soft Contact Lens Wear (비구면 소프트콘택트렌즈 착용에 의한 눈의 구면수차 변화)

  • Kim, Jeong Mee;Mun, Mi-Young;Kim, Young Chul;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.365-372
    • /
    • 2012
  • Purpose: To investigate ocular higher order aberrations (HOA) and spherical aberration changes caused by an aspheric soft contact lens designed to reduce spherical aberration (SA) of the eye. Methods: Fifty subjects who have successfully experienced soft contact lenses were refitted with aspheric design (Soflens Daily Disposable: SDD, Bausch+Lomb) soft contact lens. Ocular higher order aberrations (HOA) and stand alone SA were measured and analyzed for a 4-mm pupil size using Wave-Scan Wavefront$^{TM}$ aberrometer (VISX, Santa Clara, CA, USA). High and low contrast log MAR visual acuity and contrast sensitivity function (CSF) were also measured under photopic and mesopic conditions (OPTEC 6500 Vision Tester$^{(R)}$). All measurements were conducted monocularly with an undilated pupil. Results: The RMS mean values for total HOA with SDD contact lenses were significantly lower than those at with unaided eyes (p<0.001) and a reduction for SA in the SDD was close to the baseline SA (zero ${\mu}m$) (p<0.001). For the SDD lens, there was a statistically significant correlation between the changes in the total HOA and the contact lens power (r=0.237, p=0.018) as well as between the changes in SA and the lens power (r=0.324, p=0.001). High contrast visual acuity (HCVA) and low contrast visual acuity (LCVA) with SDD lenses were $-0.063{\pm}0.062$ and $0.119{\pm}0.060$, respectively under photopic and $-0.003{\pm}0.063$ and $0.198{\pm}0.067$, respectively under mesopic condition. Contrast Sensitivity Function (CSF) with SDD lenses under both photopic and mesopic conditions was $3.095{\pm}0.068$ and $3.087{\pm}0.074$, respectively. Conclusions: The SDD contact lens designed to control SA reduced the total ocular HOA and SA of the eye, resulting in compensating for positive SA of the eyes. Thus, the optical benefits of the lens with SA control would be adopted for improving the quality of vision.

Radiation Dose Distribution of a Surgeon and Medical Staff during Orthopedic Balloon Kyphoplasty in Japan

  • Ono, Koji;Kumasawa, Takafumi;Shimatani, Keiichi;Kanou, Masatoshi;Yamaguchi, Ichiro;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.2
    • /
    • pp.86-92
    • /
    • 2022
  • Background: The present study investigated the radiation dose distribution of balloon kyphoplasty (BKP) among surgeons and medical staff, and this is the first research to observe such exposure in Japan. Materials and Methods: The study subjects were an orthopedic surgeon (n = 1) and surgical staff (n = 9) who intervened in BKP surgery performed at the National Hospital Organization Disaster Medical Center (Tokyo, Japan) between March 2019 and October 2019. Only disposable protective gloves (0.022 mmPb equivalent thickness or less) and trunk protectors were used, and no protective glasses or thyroid drapes were used. Results and Discussion: The surgery time per vertebral body was 36.2 minutes, and the fluoroscopic time was 6.8 minutes. The average exposure dose per vertebral body was 1.46 mSv for the finger (70 ㎛ dose equivalent), 0.24 mSv for the lens of the eye (3 mm dose equivalent), 0.11 mSv for the neck (10 mm dose equivalent), and 0.03 mSv for the chest (10 mm dose equivalent) under the protective suit.The estimated cumulative radiation exposure dose of 23 cases of BKP was calculated to be 50.37 mSv for the fingers, 8.27 mSv for the lens, 3.91 mSv for the neck, and 1.15 mSv for the chest. Conclusion: It is important to know the exposure dose of orthopedic surgeons, implement measures for exposure reduction, and verify the safety of daily use of radiation during surgery and examination.

A Study on the Fabrication of Laser-Induced Graphene Humidity Sensor for Mounting on a Disposable Mask (일회용 마스크에 장착을 위한 레이저 기반 그래핀 습도센서 제작에 관한 연구)

  • Lee, Jun-Uk;Shin, Yun-Ji;Yang, Hye-Jeong;Shin, Bo-Sung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.693-699
    • /
    • 2020
  • 355nm UV pulse laser is irradiated on the surface of polyimide (PI) by LDW (Laser Direct Writing) method to produce a high sensitivity flexible humidity sensor using a simple one-step process. The LDW method continuously investigates 2-D CAD data using a galvano scanner and an F-lens. This method is non-contact, so it minimizes physical strain on the PI. Laser-induced graphene (LIG) produced by lasers has a high surface area due to its high flexibility and numerous pores and oxidizers compared to conductors. For this reason, it is highly useful as a flexible humidity sensor. The humidity sensor produced in this study was attached to the inside of a mask filter, which has become a hot topic recently, and its applicability was confirmed.The measurement of humidity measured the sensitivity, reactivity, stability and recovery behavior of the sensor by measuring changes in capacitance and resistance.

Survey on a Disposal Method of Contact Lenses after Use (콘택트렌즈 사용 후 폐기처분에 대한 실태 조사)

  • Park, Il-nam;Kwon, Min-sun;Park, Ji-woong;Lee, Ki-Seok;Jung, Mi-A;Lee, Hae-Jung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.553-560
    • /
    • 2018
  • Purpose : To investigate a disposal method of disposing contact lenses and the recognition of environmental pollution by micro plastics which may be caused by the wrong disposal method of domestic contact lens wearers. Methods : Two hundred sixty one adults(124 males, 137 females, mean age $21.48{\pm}3.14years$) were participated in this study. They were given the questionnaire survey on contact lenses purchasing place, type of contact lenses, duration of wearing contact lenses, the disposal method of disposing contact lenses and the recognition of the occurrence of environmental pollution. Results : It appeared that eyeglass shop(50.0%) and contact lens shop(48.3%) were the main purchasing places, and the most common type of contact lenses were disposable lenses(38.5%) and daily wearing lenses(52.5%). On the duration of wearing contact lenses they answered more than 5 years(29.3%), less than 1 year (26.0%), less than 1 year to less than 3 years (26.0%), and on wearing a contact lens during a week they did 1-2 days (32.0%), 1 week (28.0%), 5-6 days (22.4%) and 3-4 days (17.6%). It was shown "no(78.3%)" and "yes(21.7%)" to the questionnaire of whether they received information or education about a disposal method at the place where the contact lens was purchased, and "no(87.5%)" and "yes(12.5%)" to the questionnaire of whether they received information or education from schools, public institutions or public media such as the internet. As for the disposal methods, landfill waste(45.6%), recycled garbage(29.6%), and drainage(16.8%) from the sink or toilet responded in order. Although men were more educated and informed about disposal than women (t=3.63189, p<0.00001), women were more aware of environmental pollution(t=2.44269, p=0.01605). Conclusion : In order to reduce the environmental pollution issue caused by the contact lens which does not decompose at the sewage treatment facility and become micro plastics, it is urgent to provide information about correct disposal methods after using contact lenses and to educate contact lens wearers.

Clinical Evaluation of Prism-stabilized Toric Soft Contact Lens Fit (프리즘 안정화 디자인 토릭 소프트 콘택트렌즈 피팅에 대한 임상 평가)

  • Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • Purpose: This study was to evaluate the clinical performance of 1-Day disposable toric soft contact lenses (TSCL) and to compare the visual performance with glasses and TSCL. Methods: In a two-week investigation of 'prism ballast' designed TSCL, occular refractions in 15 (30 eyes) healthy subjects were within the range of -2.75 D TO -8.00 D spherical power and -0.75 DC to -2.25 DC cylinderical power (with-the-rule). Subjects were assessed the clinical performance (orientation, centration, movement, tightness, rotation recovery, symptoms) of TSCL and compared binocular vision and contrast sensitivity with corrected glasses and TSCL at initial and two-week follow-up visits. Results: The prism-ballast design TSCL achieved better orientation, rotation recovery and symptoms over 2 week period. There was no statistically significant difference between spectacles and TSCL with respect to measuring binocular vision and contrast sensitivity. Conclusions: The clinical performance was good with prism-ballast design toric soft contact lenses. Evaluation of binocular vision and contrast sensitivity did not show the differences between spectacles and TSCL correction. This study suggests that TSCL wearers can be achieved similar visual performance for spectacles wearers.