• 제목/요약/키워드: displacer

검색결과 38건 처리시간 0.025초

일체형 스터링 냉동기의 설계, 제작 및 성능특성에 관한 연구 (A study on the performance characteristics of rotary type Stirling cryocooler)

  • 박성제;홍용주;김효봉;김양훈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권1호
    • /
    • pp.54-58
    • /
    • 2006
  • Stirling cryocooler is relatively compact, reliable, commercially available. and uses helium as a working fluid. Over the past decade and a half, there has been rapid development of Stirling cryocooler, mainly for military and space applications. Stirling cryocoolers have been widely used lot the cooling of infrared sensors and high temperature superconducting filters to the temperature of the liquid nitrogen. The Stirling cryocooler with the rotary compressor is applicable to the cooling device for the compact mobile thermal imaging system, because the cryocoolers have the compact structure and light weight. In this paper, integral Stirling cryocooler is designed, manufactured and fabricated, and performance characteristics are investigated. This cooler delivers approximately 0.6W cooling at 80K for 20W of input power from 24V DC power supply.

자유 피스톤 스털링엔진/발전기의 설계 인자 연구 (A Study on the Design of the Free-Piston Stirling Engine/Alternator)

  • 박성제;홍용주;고준석;김효봉;염한길;인세환;강인수;이청수
    • 한국수소및신에너지학회논문집
    • /
    • 제25권6호
    • /
    • pp.648-655
    • /
    • 2014
  • This paper describes the continuing effort to develope a single acting free-piston Stirling engine/alternator combination for use of the household cogeneration. Free piston Stirling engines(FPSE) use variations of working gas pressure to drive mechanically unconstrained reciprocating elements. Stirling cycle free-piston engines are driven by the Stirling thermodynamic cycle which is characterized by an externally heated device containing working gas that is continuously re-used in a regenerative, reversible cycle. The ideal cycle is described by two isothermal process connected by two constant volume processes. Heat removed during the constant volume cooling process is internally transferred to the constant volume heating process by mutual use of a thermal storage medium called the regenerator. Since the ideal cycle is reversible, the ideal efficiency is that of Carnot. Free-piston Stirling engine is have no crank and rotating parts to generate lateral forces and require lubrication. The FPSE is typically comprised of two oscillating pistons contained in a common cylinder. The temperature difference across the displacer maintains the oscillations, and the FPSE operate at natural frequency of the mass-spring system. The power is generated from a linear alternator. The purpose of this paper is to describe the design process of the single acting free-piston Stirling engine/alternator. Electrical output of the single acting free-piston Stirling engine/alternator is about 0.95 kW.

Development of high capacity stirling cryocooler

  • Ko, Junseok;Yeom, Hankil;Kim, Hyobong;Hong, Yong-Ju;In, Sehwan;Park, Seong-Je
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.51-56
    • /
    • 2015
  • Cryogenic cooling system for HTS electric power devices requires a reliable and efficient high-capacity cryocooler. A Striling cryocooler with a linear compressor can be a good candidate. It has advantages of low vibration and long maintenance cycle compared with a kinematic-driven Stirling cryocooler. In this study, we developed dual-opposed linear compressor of 12 kW electric input power with two 6 kW linear motors. Electrical performance of fabricated linear compressor is verified by experimental measurement of thrust constant. The developed Stirling cryocooler has gamma-type configuration. Piston and displacer are supported with flexure spring. A slit-type heat exchanger is adopted for cold and warm-end, and the generated heat is rejected by cooling water. In cooling performance test, waveforms of voltage, current, displacement and pressure are obtained and their amplitude and phase difference are analysed. Moreover, temperatures of cooling water, housing and linear motor are recorded and electric power parameters of driving circuit are also obtained. The developed Stirling cryocooler reaches to 47.8 K within 23.4 min. with no-load. From heat load tests, it shows cooling capacity of 440 W at 78.1 K with 6.45 kW of electric input power and 19.4 of % Carnot COP.

Performance and Reliability Characteristics of the Free Piston Free Displacer Stirling Cryocooler

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Koh, Deuk-Yong;Kim, Yang-Hoon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권2호
    • /
    • pp.46-51
    • /
    • 2004
  • This paper presents the results of a series of performance and reliability tests for the Stirling cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate specification for the performance and reliability. FPFD Stirling cryocooler is currently under development for cooling infrared detector. Manufactured Stirling cryocooler delivers approximately 0.9W cooling at 80K for 30W∼40W of input power. It takes approximately 2 minutes to cool down to 80K at the ambient temperature of 23$^{\circ}C$. Performance characteristics for the vibration, acoustic noise, EMI and leak rate of the Stirling cryocooler are evaluated. We performed low and high temperature keeping test from -32$^{\circ}C$ to +52$^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity is determined as a function of the temperatures at the compressor, hot end and cold tip at the expander. Finally, we describe the experimental facility for the MTTF evaluation and some typical results of the Stirling cryocooler.

Magnetic refrigerator for hydrogen liquefaction

  • Numazawa, T.;Kamiya, K.;Utaki, T.;Matsumoto, K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권2호
    • /
    • pp.1-8
    • /
    • 2013
  • This paper reviews the development status of magnetic refrigeration system for hydrogen liquefaction. There is no doubt that hydrogen is one of most important energy sources in the near future. In particular, liquid hydrogen can be utilized for infrastructure construction consisting of storage and transportation. Liquid hydrogen is in cryogenic temperatures and therefore high efficient liquefaction method must be studied. Magnetic refrigeration which uses the magneto-caloric effect has potential to realize not only the higher liquefaction efficiency > 50 %, but also to be environmentally friendly and cost effective. Our hydrogen magnetic refrigeration system consists of Carnot cycle for liquefaction stage and AMR (active magnetic regenerator) cycle for precooling stages. For the Carnot cycle, we develop the high efficient system > 80 % liquefaction efficiency by using the heat pipe. For the AMR cycle, we studied two kinds of displacer systems, which transferred the working fluid. We confirmed the AMR effect with the cooling temperature span of 12 K for 1.8 T of the magnetic field and 6 second of the cycle. By using the simulation, we estimate the total efficiency of the hydrogen liquefaction plant for 10 kg/day. A FOM of 0.47 is obtained in the magnetic refrigeration system operation temperature between 20 K and 77 K including LN2 work input.

GM형 맥동관 냉동기의 저온부 경사도에 따른 냉각 성능 특성 연구 (Orientation dependence of GM-type pulse tube refrigerator)

  • 고준석;김효봉;박성제;홍용주;염한길;이청수;강인수;고득용
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권3호
    • /
    • pp.48-52
    • /
    • 2012
  • This paper describes experimental study on the orientation dependence of GM-type pulse tube refrigerator with helium and neon as working gas. A pulse tube refrigerator generates refrigeration work with gas expansion by gas displacer in the pulse tube. The pulse tube is only filled with working gas and there exists secondary flow due to large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube with orifice valve as a phase control device is fabricated and tested. The fabricated pulse tube refrigerator is tested with two different working gases of helium and neon. First, optimal valve opening and operating frequency are determined with experimental results of no-load test. And then, the variation of no-load temperature as orientation angle of cold-head is measured for two different working gases. Effect of orientation dependence of cold-head as working gas is discussed with experimental results.

Development of an Alignment Method for Retarders in isoSTED Microscopy

  • Ilkyu Park;Dong-Ryoung Lee
    • Current Optics and Photonics
    • /
    • 제8권4호
    • /
    • pp.421-426
    • /
    • 2024
  • The use of stimulated emission depletion (STED) microscopy has significantly improved resolution beyond the limits imposed by diffraction; Furthermore, STED microscopy adopts a 4Pi-geometry to achieve an isotropic improvement in resolution. In isoSTED microscopy, a polarizing beam splitter and retarders are used in a 4Pi cavity to split beams of identical power, generating constructive and destructive interference for lateral and axial resolution improvements, respectively. The precise alignment of the retarders is crucial for optimizing the performance of isoSTED microscopy, because this orientation affects the quality of the depletion focus, necessitating zero intensity at the center. Incomplete destructive interference can lead to unwanted fluorescence inhibition, resulting in degraded resolution and contrast. However, measuring the intensity and polarization state in each optical path of the 4Pi cavity is complex and requires additional devices such as a power meter. Here, we propose a simple and accurate alignment method for the 4Pi cavity in isoSTED microscopy. Our approach demonstrates the equal allocation of power between upper and lower beam paths and achieves complete destructive interference using a polarizing beam displacer and a single CCD camera positioned outside the 4Pi cavity.

스터링 기관의 피스톤 밀봉 기구에 관한 연구 (Studies on Piston Seal Mechanism of Stirling Engine)

  • 김태한
    • Journal of Biosystems Engineering
    • /
    • 제17권4호
    • /
    • pp.305-313
    • /
    • 1992
  • Stirling 기관(機關)의 피스톤 Seal부분에서의 마찰저항(摩擦抵抗)을 감소(減少)시킴과 동시 에 작동가스의 누설량(漏泄量)을 감소(減少)시켜서 기관출력(機關出力)을 증대(增大)시킬 목적(目的)으로 재질(材質) 및 밀봉(密封) 형식(形式)이 서로 다른 Piston ring식 밀봉기구(密封機構)와 금속(金屬) Bellows를 이용한 밀봉기구(密封機構)를 시작(試作)해서 마찰저항(摩擦抵抗)과 작동가스의 누설량(漏泄量)을 조사(調査)하고, 이들 밀봉기구(密封機構)를 실험(實驗) 기관(機關)에 장착(裝着)해서 운전시험(運轉試驗)을 통해 각 밀봉기구(密封機構)의 성능(性能)을 검토(檢討)하였다. 그 결과(結果) Bellows를 Power piston의 Actuator로 시작(試作)한 밀봉기구(密封機構)가 다른 Piston-ring식(式) 밀봉기구(密封機構)에 비(比)해, 피스톤링과 실린더벽 사이의 마찰저항(摩擦抵抗) 및 작동(作動)가스의 누설량(漏泄量)이 현저하게 감소(減少)하였으며, D-type은 B-type에 비해 도시출력(圖示出力)은 약 1.6배, 축출력(軸出力)은 약 1.2배로 증가(增加)하였다.

  • PDF