• Title/Summary/Keyword: displacement-based seismic design

Search Result 306, Processing Time 0.028 seconds

Seismic Performance of Square RC Column Confined with Spirals (나선철근으로 횡구속된 정사각형 RC 기둥의 내진성능)

  • Ko, Seong Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.88-97
    • /
    • 2012
  • The objective of this research is to investigate the seismic performance and flexure-shear behavior of square reinforced concrete bridge piers with solid and hollow cross section. Test specimens were nonseismically designed with the aspect ratio 4.5 Two reinforced concrete columns were tested under constant axial load while subjected to lateral load reversals with increasing drift levels. Longitudinal steel ratio was 2.217 percent. The transverse reinforcement ratio As/($s{\cdot}h$), corresponding to 58 percent of the minimum lateral reinforcement required by Korean Bridge Design Specifications for seismic detailing, which represent existing columns not designed by the current seismic design specifications or designed by limited ductility concept. This study are to provide quantitative reference data for the limited ductility design concept and tendency for performance or damage assessment based on the performance levels such as cracking, yielding, collapse, etc. Failure behavior, ultimate displacement/drift ratio, displacement ductility, response modification factor, equivalent viscous damping ratio, residual deformation, effective stiffness, plastic hinge length, strain of reinforcements and nonlinear analysis are investigated and discussed in this paper.

Evaluation of ASCE 61-14 NSPs for the estimation of seismic demands in marginal wharves

  • Smith-Pardo, J. Paul.;Reyes, Juan C.;Sandoval, Juan D.;Hassan, Wael M.
    • Structural Engineering and Mechanics
    • /
    • v.69 no.1
    • /
    • pp.95-104
    • /
    • 2019
  • The Standard ASCE 61-14 proposes the Substitute Structure Method (SSM) as a Nonlinear Static Procedure (NSP) to estimate nonlinear displacement demands at the center of mass of piers or wharves under seismic actions. To account for bidirectional earthquake excitation according to the Standard, results from independent pushover analyses in each orthogonal direction should be combined using either a 100/30 directional approach or a procedure referred to as the Dynamic Magnification Factor, DMF. The main purpose of this paper is to present an evaluation of these NSPs in relation to four wharf model structures on soil conditions ranging from soft to medium dense clay. Results from nonlinear static analyses were compared against benchmark values of relevant Engineering Design Parameters, EDPs. The latter are defined as the geometric mean demands that are obtained from nonlinear dynamic analyses using a set of 30 two-component ground motion records. It was found that SSM provides close estimates of the benchmark displacement demands at the center of mass of the wharf structures. Furthermore, for the most critical pile connection at a landside corner of the wharf the 100/30 and DMF approaches produced displacement, curvature, and force demands that were reasonably comparable to corresponding benchmark values.

Seismic performance of prefabricated bridge columns with combination of continuous mild reinforcements and partially unbonded tendons

  • Koem, Chandara;Shim, Chang-Su;Park, Sung-Jun
    • Smart Structures and Systems
    • /
    • v.17 no.4
    • /
    • pp.541-557
    • /
    • 2016
  • Prefabricated bridge substructures provide new possibility for designers in terms of efficiency of creativity, fast construction, geometry control and cost. Even though prefabricated bridge columns are widely adopted as a substructure system in the bridge construction project recently, lack of deeper understanding of the seismic behavior of prefabricated bridge substructures cause much concern on their performance in high seismic zones. In this paper, experimental research works are presented to verify enhanced design concepts of prefabricated bridge piers. Integration of precast segments was done with continuity of axial prestressing tendons and mild reinforcing bars throughout the construction joints. Cyclic tests were conducted to investigate the effects of the design parameters on seismic performance. An analytical method for moment-curvature analysis of prefabricated bridge columns is conducted in this study. The method is validated through comparison with experimental results and the fiber model analysis. A parametric study is conducted to observe the seismic behavior of prefabricated bridge columns using the analytical study based on strain compatibility method. The effects of continuity of axial steel and tendon, and initial prestressing level on the load-displacement response characteristics, i.e., the strain of axial mild steels and posttensioned tendon at fracture and concrete crushing strain at the extreme compression fiber are investigated. The analytical study shows the layout of axial mild steels and posttensioned tendons in this experiment is the optimized arrangement for seismic performance.

Seismic Design of Buckling-Restrained Braced frame Using Equivalent Energy Concept (등가 에너지 개념을 이용한 비좌굴 가새골조의 내진설계)

  • 김진구;최현훈;원영섭
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.47-55
    • /
    • 2003
  • This study proposed a convenient seismic design procedure for buckling-restrained braced frames based on the equivalent energy concept. The design process begins with the computation of input energy from response spectrum. Then the elastic energy and plastic energy are computed based on the equal energy concept. The computed plastic energy is distributed to each story along energy distribution ratio and the cross-sectional area of each brace is computed so that all the plastic energy is dissipated by the brace. The proposed procedure was applied to the design of three-, six-, and twenty-story steel frames with buckling-restrained braces, and artificial earthquake records were used for verification of the proposed method. According to analysis results, top story displacements of the low-rise structure satisfies the given target displacement however that of the twenty-story structure was much smaller than the given target displacement.

Research on the anti-seismic performance of composite precast utility tunnels based on the shaking table test and simulation analysis

  • Yang, Yanmin;Li, Zigen;Li, Yongqing;Xu, Ran;Wang, Yunke
    • Computers and Concrete
    • /
    • v.27 no.2
    • /
    • pp.163-173
    • /
    • 2021
  • In this paper, the parameters of haunch height, reinforcement ratio and site condition were evaluated for the influence on the seismic performance of a composite precast fabricated utility tunnel by shaking table test and numerical simulation. The dynamic response laws of acceleration, interlayer displacement and steel strain under unidirectional horizontal seismic excitation were analyzed through four specimens with a similarity ratio of 1:6 in the test. And a numerical model was established and analyzed by the finite element software ABAQUS based on the structure of utility tunnel. The results indicated that composite precast fabricated utility tunnel with the good anti-seismic performance. In a certain range, increasing the height of haunch or the ratio of reinforcement could reduce the influence of seismic wave on the utility tunnel structure, which was beneficial to the structure earthquake resistance. The clay field containing the interlayer of liquefied sandy soil has a certain damping effect on the structure of the utility tunnel, and the displacement response could be reduced by 14.1%. Under the excitation of strong earthquake, the reinforcement strain at the side wall upper end and haunches of the utility tunnel was the biggest, which is the key part of the structure. The experimental results were in good agreement with the fitting results, and the results could provide a reference value for the anti-seismic design and application of composite precast fabricated utility tunnel.

Simplified procedure for seismic analysis of base-isolated structures

  • Serror, Mohammed H.;El-Gazzar, Sherif O.;Mourad, Sherif A.
    • Earthquakes and Structures
    • /
    • v.8 no.5
    • /
    • pp.1091-1111
    • /
    • 2015
  • Base isolation is an effective method for protecting structures against earthquake hazard. It elongates the period of vibration and introduces supplemental damping to the structural system. The stiffness, damping and displacement are coupled forcing the code seismic design procedure to be unnecessarily complicated. In addition, the force reduction factor -a key parameter in the design procedurehas not been well addressed by seismic design codes at the high levels of damping due to the pronounced difference between pseudo and actual accelerations. In this study, a comparison has been conducted to evaluate eight different methods, in the literature, for calculating the force reduction factor due to damping. Accordingly, a simplified seismic analysis procedure has been proposed based on the well documented N2 method. Comprehensive analysis has been performed for base-isolated structure models for direct application and verification of the proposed procedure. The results have been compared with those of the European code EC8, the nonlinear time history analysis and investigations in the literature, where good agreement has been reported. In addition, a discussion has been elaborated for the resulted response of the base-isolated structure models with respect to the dynamic characteristics of the base isolation system.

Seismic Performance Evaluation of Building Structures Using Modified Capacity Spectrum (수정된 능력스펙트럼을 이용한 건축구조물의 내진성능평가)

  • 최원호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.267-274
    • /
    • 2000
  • Current seismic design codes for building structures are based on the method which can provide enough capacity to satisfy objected performance level and exactly evaluate the seismic performance of buildings. The capacity spectrum method using the nonlinear static(pushover) analysis is becoming a popular tool for evaluating the seismic performance of existing and new building structures. By means of a graphical procedure capacity spectrum method esimates the performance level of structure by comparing the capacity of structure with the demand of earthquake ground motion on the structure. In the method the relation between base shear estimated by a nonlinear static analysis and horizontal displacement is used. Capacity spectrum is usually expressed as what represent the responses of the equivalent single degree of freedom (ESDOF) system for the building structures. However there are some problems in converting procedures into ESDOF system which include not considering the effect of higher modes of structures. The objective of this paper is to compare and verify existing methods and suggest the modified capacity spectrum for seismic performance evaluation of building structures.

  • PDF

Seismic response of a high-rise flexible structure under H-V-R ground motion

  • We, Wenhui;Hu, Ying;Jiang, Zhihan
    • Earthquakes and Structures
    • /
    • v.23 no.2
    • /
    • pp.169-181
    • /
    • 2022
  • To research the dynamic response of the high-rise structure under the rocking ground motion, which we believed that the effect cannot be ignored, especially accompanied by vertical ground motion. Theoretical analysis and shaking table seismic simulation tests were used to study the response of a high-rise structure to excitation of a H-V-R ground motion that included horizontal, vertical, and rocking components. The use of a wavelet analysis filtering technique to extract the rocking component from data for the primary horizontal component in the first part, based on the principle of horizontal pendulum seismogram and the use of a wavelet analysis filtering technique. The dynamic equation of motion for a high-rise structure under H-V-R ground motion was developed in the second part, with extra P-△ effect due to ground rocking displacement was included in the external load excitation terms of the equation of motion, and the influence of the vertical component on the high-rise structure P-△ effect was also included. Shaking table tests were performed for H-V-R ground motion using a scale model of a high-rise TV tower structure in the third part, while the results of the shaking table tests and theoretical calculation were compared in the last part, and the following conclusions were made. The results of the shaking table test were consistent with the theoretical calculation results, which verified the accuracy of the theoretical analysis. The rocking component of ground motion significantly increased the displacement of the structure and caused an asymmetric displacement of the structure. Thus, the seismic design of an engineering structure should consider the additional P-△ effect due to the rocking component. Moreover, introducing the vertical component caused the geometric stiffness of the structure to change with time, and the influence of the rocking component on the structure was amplified due to this effect.

Comparison of Performance Evaluation Methods Based on the Estimation of Nonlinear Seismic Responses for Multistory Building (건축구조물의 비선형 지진응답 산정을 위한 내진성능평가 방법의 비교)

  • 최원호;이동근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.349-356
    • /
    • 2002
  • There has been an increasing trend toward the use of pushover analysis as a tool for evaluating the seismic resistant and safety of a building structure in the performance based earthquake engineering field. The ATC-40 document proposed a nonlinear static procedure based on the Capacity Spectrum Method to determine earthquake-induced demand given the structure pushover curve, which a curve representing base shear versus roof displacement. However, the procedure is conceptually simple, iterative and time consuming method and may sometimes lead to no solution or multiple solutions. A new improved method of seismic performance evaluation for moment frame building, which take into account the previously mentioned deficiencies of currently used elastic design procedures, is presented in this paper. The results of nonlinear static and nonlinear time history analysis of an example high-rise steel moment frame designed by the proposed method are presented and discussed.

  • PDF

A Study on the Dynamic Behaviour of Composite Breakwaters Based on Dynamic Analysis Considering Effective Stresses (유효응력을 고려한 동해석을 통한 직립식 방파제의 동적 거동에 대한 연구)

  • Youngjin Jeon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.25 no.11
    • /
    • pp.45-53
    • /
    • 2024
  • In the current work, finite difference analysis was conducted by investigating the influence of dynamic analysis, considering effective stress, on the dynamic response of composite breakwaters. For comparison, the seismic behavior of breakwaters during the Kobe earthquake was analyzed, and performance-based seismic design was validated through centrifuge model test data, accompanied by a parametric study. The composite breakwaters damaged by the Kobe earthquake were verified through numerical analysis based on effective stress analysis, and validation of both centrifuge model tests and numerical analysis methods was conducted. The results of numerical analysis confirmed the seismic resistance based on the performance-based. And the results of analysis identified similar vertical displacement and liquefaction have confirmed through excess pore pressures. Also this study was conducted on the based on performance-based seismic deign, focusing on the results of acceleration, displacement, pore pressure, and liquefaction. Therefore the purpose of this study is to verify the results of pore pressure and liquefaction through the application and non-application of Finn model to compare the determination of liquefaction by the effective stress analysis.