• Title/Summary/Keyword: displacement current method

Search Result 313, Processing Time 0.028 seconds

전단류 하중을 받는 상부장력 라이저의 동적 응답 해석 (Dynamic Response Analysis of Top-tensioned Riser Under Sheared Current Load)

  • 김국현
    • 한국해양공학회지
    • /
    • 제27권4호
    • /
    • pp.83-89
    • /
    • 2013
  • A numerical scheme based on a mode superposition method is presented for the dynamic response analysis of a top-tensioned riser (TTR) under sheared current loads. The natural frequencies and mode shapes of the TTR have been calculated analytically for a beam with a slowly varying tension and pinned-pinned boundary conditions at the top and bottom ends. The lift coefficients and corresponding amplitudes used to estimate the vortex-induced modal force and damping for each mode were predicted via iterative calculations based on the input and output power balancing concept. Here, the power-in regions were controlled by the normal distribution function, for which the center was coincident with the lock -in location by local vortex-shedding, and the range was defined by the constant standard deviation for the reduced velocity by the local current speed. Finally, dynamic responses such as root-mean-squared displacement and stress were calculated using the mode superposition technique. In order to verify the presented scheme, a numerical calculation was performed for a TTR under an arbitrary linearly sheared current and linearly varying tension. A comparison with the results of the existing software showed that the presented scheme could give reliable and feasible solutions. Case studies were performed to investigate the effects of various current loads and tensions.

정규화법을 이용한 원전배관 용접부의 동하중 파괴저항시험 (Dynamic Fracture Testing of Welding part of Nuclear Piping by Using Normalization Method)

  • 허용;조성근;박재실;석창성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.262-267
    • /
    • 2004
  • The unloading compliance method is the most commonly used method to evaluate the fracture resistance characteristics of a material. In dynamic loading condition, the direct current potential drop(DCPD) method has been used because the unloading compliance method can not be applied due to the discontinuity of loading. However, even in the dynamic test using DCPD method, there is a problem that the voltage drops sharply on the initiation of crack. For the reason metioned above, the normalization method was suggested on ASTM E 1820 which is revised recently, as a new method to evaluate the dynamic fracture resistance characteristic. The nomalization method can be used to obtain a fracture resistance curve directly from a load-load line displacement. In this study, we obtained two fracture resistance curves from static test of welding part of nuclear piping both by unloading compliance and nomalization method. The two curves were almost same each other, so the adaptability of the nomalization method has been proved. We conducted a dynamic fracture resistance test for the same material. The fracture resistance curve from the dynamic test was obtained by normalization method and compared to that of the static test result.

  • PDF

유도전동기 벡터제어 시스템에서 DQ변환을 이용한 시간지연 보상 (Compensation of Time Delay in Induction Motor Vector Control System Using DQ Transformation)

  • 최병태;권우현;박철우
    • 제어로봇시스템학회논문지
    • /
    • 제9권12호
    • /
    • pp.1001-1008
    • /
    • 2003
  • A time-delay compensation method for vector control system is proposed that can compensate for voltage and current distortions resulting from a time delay in the overall system due to the low pass filter, hysteresis control inverter, microprocessor program computation time, and so on. The proposed scheme estimates the time delay using the difference between the Q-axis stator current command and the time-delayed actual Q-axis stator current in a synchronous reference frame, then compensates the time delay in the voltage and current using the angular displacement of a DQ transformation. Accordingly, the proposed scheme can accurately compensate for the time delay related to the overall system, thereby significantly improving the performance of the vector control system, as verified by simulation and experiment.

유도전동기 벡터제어 시스템의 시간지연 보상 (Time Delay Compensation of Induction Motor Vector Control System)

  • 박철우;최연호;임성운;윤경섭;권우현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.231-231
    • /
    • 2000
  • It is proposed that a novel method which can compensate the time delay occurs in overall system, when voltage and current is measured, owing to LPF, hysteresis control inverter and microprocessor program computation time. The Proposed scheme estimates the time delay using the difference between Q-axis stator current command and time delayed Q-axis stator current in synchronous reference frame, and compensates the time delay of voltage and current using angular displacement of DQ transformation. The proposed scheme compensates accurately the time delay occurs in overall system. Therefore performance of vector control system is improved highly and it is verified by simulation and experiment.

  • PDF

Array Sensing Using Electromagnetic Method for Detection of Smelting in Submerged Arc Furnaces

  • Liu, WeiLing;Han, XiaoHong;Yang, LingZhen;Chang, XiaoMing
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.322-329
    • /
    • 2016
  • In this paper, we propose an array sensing detection method for smelting of submerged arc furnaces (SAF) based on electromagnetic radiation. AC magnetic field generated by electrode currents and molten currents in the furnace is reflected outside of the furnace. According to the spatial distribution of electromagnetic field a radiation model of SAF is built. We design a 3D magnetic field sensing array system in order to collect the magnetic field information. Through the collected information, the current distribution characteristics of SAF are described and the key parameters of smelting are obtained. Theoretical simulation and field test show that the curves acquired by the sensing array can accurately reflect the information of the relative displacement when the relative displacement between the array and electrode is 10 cm. Compared with the detection method of 3D single point, the proposed array sensing method of magnetic field obtains better results in terms of real-time and accuracy, and has good practical value for industrial measurement.

엇갈린 격자를 이용한 3차원 유한차분 시간영역 전자탐사 모델링 (Three-dimensional Finite Difference Modeling of Time-domain Electromagnetic Method Using Staggered Grid)

  • 장한길로;남명진;조성오;김희준
    • 지구물리와물리탐사
    • /
    • 제20권3호
    • /
    • pp.121-128
    • /
    • 2017
  • 국내에서 시간영역 전자탐사(time-domain/transient electromagnetic, TEM) 자료의 해석은 1차원 알고리듬에 주로 의존하고 있는 실정이기 때문에 정밀한 해석을 위하여 3차원 모델링 및 역산 해석 프로그램의 개발이 필요한 상황이다. 이 연구에서는 엇갈린 격자를 이용한 시간영역 유한차분(staggered-grid finite-difference time-domain, FDTD)법에 기초하여 3차원 TEM 반응 모델링 알고리듬을 개발하였다. 시간영역 전자탐사의 모델링을 위해 맥스웰 방정식을 현시적 중앙점 FDTD법을 이용하여 이산화하였으며 수치 안정성을 높이기 위해 가상 변위전류항을 도입하였다. 일반적으로 많이 활용되는 소형 코일 송신원을 수치적으로 구현하여 균질 반무한 공간에서의 해석해와 비교 검증하고 3차원 이상체에 대한 반응을 분석하였다. 이 연구에서 개발된 모델링 프로그램은 향후 TEM 전자탐사 자료의 정밀 해석에 기초가 될 것으로 기대한다.

수면상 단분자막의 광자격에 의한 변위전류 (The Displacement Current of Optically - stimulatred Monolayers on the Water Surface)

  • 배명한;김형우;조완제;송경호;박근호;권영수;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1971-1973
    • /
    • 1999
  • Monolayers of azo-benzene group containing fatty acids(8A5H) were made by spreading and compressing on the water surface. These monolayers were optically stimulated by illuminating the lights of 365[nm] and 450[nm] from X-non lamp, and the structural changes of the molecules were measured by the displacement current method. Also, the dynamic behaviors of these monolayers were measured by the $\pi-A$ isotherms when changing the temperatures of the water surface. As results, when the monolayers were stimulated by 365[nm] light, the positive currents which were generated by the structural changes from trans to cis were measured. But the negative currents of the structural changes from cis to trans were too weak to detect. When the temperatures of the water surface were increased, surface pressures of the monolayers increased early because of the thermal activations of the molecules, and the double liquid film phase were disappeared upon $40[^{\circ}C]$.

  • PDF

접합부 회전능력에 기초한 중/저층 철골모멘트골조의 내진설계 (Seismic Design of Mid-to-Low Rise Steel Moment Frames Based on Available Connection Rotation Capacity)

  • 안재권;이철호
    • 한국강구조학회 논문집
    • /
    • 제19권6호
    • /
    • pp.715-723
    • /
    • 2007
  • 본 연구에서는 중/저층의 철골모멘트골조를 대상으로 합리적이고 실용적인 변위기반 내진설계절차를 제시하였다. 현행의 내진설계에서는 구조시스템 종별에 따라 경험적이고 획일적으로 규정된 반응수정계수를 토대로 설계가 수행되므로, 접합부가 보유한 회전능력의 적정성 여부를 검증하기가 어렵다. 본 논문에서는 실험적으로 입증된 철골모멘트골조 접합부의 가용 소성회전능력을 주요설계변수로 직접 사용하는 새로운 설계법을 제시하였다. 이 설계방안의 정립을 위해, 우선 지금까지 불분명한 관계로 남아있던 접합부의 가용 소성회전능력과 반응수정계수 사이의 관계를 합리적이고 정량적으로 정의하는 방안을 제시하였다. 이를 토대로 변위에 기반한 단계별 내진설계절차를 제시하고 비선형동적해석에 의해 방안의 타당성을 입증하였다.

A Study on the Electrical Physical Properties of Organic Thin Films for Manufacture in Power Device

  • Song, Jin-Won;Lee, Kyung-Sup
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권1호
    • /
    • pp.18-21
    • /
    • 2005
  • Monolayers of lipids on a water surface have attracted much interest as models of biological membranes, but also as precursors of multilayer systems promising many technical applications. Until now, many methodologies have been developed in order to gain a better understanding of the relationship between the structure and function of the monolayers. Maxwell displacement current (MDC) measurement has been employed to study the dielectric property of Langmuirfilms. MDC flowing across monolayers is analyzed using a rod-like molecular model. A linear relationship between the monolayer compression speed a and the molecular area Am. Compression speed a was about 30, 40, and 50 mm/min. Langmuir-Blodgett(LB) layers of Arachidic acid deposited by LB method were deposited onto slide glass as Y-type film. The structure of manufactured device is Aul Arachidic acid! AI, the number of accumulated layers are $9{\sim}21$. Also, we then examined of the Metal-Insulator-Metal(MIM) device by means of I-V. The I-V characteristics of the device are measured from -3 to+3 V. The insulation property of a thin film is better as the distance between electrodes is larger.

전력 소자용 유기박막의 전기적 특성 (Electrical Properties of Organic Thin Film for Power Device)

  • 송진원;최용성;문종대;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 영호남 합동 학술대회 및 춘계학술대회 논문집 센서 박막 기술교육
    • /
    • pp.20-22
    • /
    • 2006
  • Monolayers of lipids on a water surface have attracted much interest as models of biological membranes, but also as precursors of multilayer systems promising many technical applications. Until now, many methodologies have been developed in order to gain a better understanding of the relationship between the structure and function of the monolayers. Maxwell displacement current (MDC) measurement has been employed to study the dielectric property of Langmuir-films. MDC flowing across monolayers is analyzed using a rod-like molecular model. A linear relationship between the monolayer compression speed and the molecular area Am. Compression speed was about 30, 40, 50mm/min. Langmuir-Blodgett(LB)layers of Arachidic acid deposited by LB method were deposited onto slide glass as Y-type film. The structure of manufactured device is Au/Arachidic acid/Al, the number of accumulated layers are 9~21. Also, we then examined of the Metal-Insulator-Metal(MIM) device by means of I-V. The I-V characteristics of the device are measured from -3 to +3[V]. The insulation property of a thin film is better as the distance between electrodes is larger.

  • PDF