• Title/Summary/Keyword: dismount

Search Result 8, Processing Time 0.02 seconds

Analysis of Successful Landing of the Salto Backward Dismount on the Parallel Bars (평행봉 몸 접고 2회전 뒤 공중 돌아 내리기 동작에 따른 착지동작의 성공요인 분석)

  • Han, Yoon-Soo;Lee, Yong-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.2
    • /
    • pp.75-87
    • /
    • 2003
  • The purpose of this study was to identify the mechanical factors that are crucial to the successful double salto backward piked dismount on the parallel bars. The subjects were 5 national gymnasts(G1: sucessed landing, G2: failed landing), two video cameras were used to record the dismount of the subjects. It summarizes that (a) It is important to make small slope angle(X axis, Y axis) at release, whereas it makes large shoulder angle and trunk rotation angle. (b) It is important to prepare landing in advance, reducing vertical velocity and making large hip angle at BTO(body take off). (c) It is also important to make small knee angle and hip angle, and reduce the angle of trunk rotation.

Analysis of the Research Trend of Artistic Gymnastics on the Sports Biomechanics (기계체조의 운동역학적 연구동향 분석)

  • Han, Yoon-Soo;Kwon, Oh-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.93-101
    • /
    • 2007
  • The purpose of this study was to analyze the research trends of artistic gymnastics on the kinetics. This study analyzed the 76 published papers in the Journal of Korean Alliance for Health, Physical Education, Recreation & Dance and Korean Journal of Sport Biomechanics between 1995 and 2006. Papers were split into two groups for analysis, 1995-1999 and 2000-2006, and classified according to research methods, areas, and main topics. Conclusions are as follow. First, method of research were kinematical research(80.3%), kinetic(17.1%), and EMG research(2.6%). Second, areas of research were hi-bar(31.6%), vault(23.7%), parallel bars(21.1%), floor exercise(13.2%), rings(3.9%), balance beam(3.9%), uneven bars(2.6%). Last, main topic of research were focused on vault Tsukahara skill(13.9%), hi-bar flight skill(11.4%), parallel bars support skill(10.1%), hi-bar dismount skill(8.9%), floor exercise salto skill(8.9%).

Measurement of moisture contents of oil-paper in transformer with RVM (RVM을 이용한 변압기 절연유와 절연지의 온도에 따른 수분함유량 측정)

  • Han, Hee-Joon;Han, Sang-Ok;Lee, Sei-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.79-81
    • /
    • 2005
  • Chemical methods for moisture contents detection of insulation system in transformer must dismount equipment for sampling, and there is shortcoming such as acquiring partial data for measuring. Also the samples can't immediately analyze in field. The Recovery Voltage Method (RVM) will be able to measure a moisture contents at low voltage without dismounting equipment. Therefore, in advanced countries RVM would be used to measure the moisture contents which permeates to the insulation system without weighting additive degradation or mechanical damage. In this paper we have investigated for overcoming these shortcomings using the RVM, and we have measured the moisture contents of transformer insulation with temperature.

  • PDF

Numerical Analysis for Development of Vertical Falling Prevention System

  • Kwon, Oh-Heon;Kim, Sang-Tae;Kang, Ji-Woong
    • International Journal of Safety
    • /
    • v.8 no.2
    • /
    • pp.1-4
    • /
    • 2009
  • Various falling prevention systems with vertical guided rail have been supplied in order to prevent falling accidents and acquire the long life and cost down for the maintenance. Almost the imported system is composed of a guided rail and the comfort components. It has the mechanism that cannot be dismounted from the guided rail at the accident site. Thus, the aim of this study is to develop a falling prevent system that has a direct dismounting function, which can release easily from the falling accident point. This system has a high durability and robust. And the cost efficiency of the system and safety for workers also are improved remarkably. From the results, we showed the proposed new falling system is sufficiently safety and satisfies the KOSHA regulation through the numerical stress analysis. Also it is expected as the useful and effective safety device for workers.

The Kinematical Analysis of Parallel Bars Double Piked Landing Motion (평행봉 double piked 내리기 동작의 운동학적 분석)

  • Kwon, Oh-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.311-318
    • /
    • 2010
  • This study examined the double piked dismount among the landing techniques of parallel bars based on three-dimensional motion analysis. Four male national gymnasts were the subjects. This study was performed to provide quantitative data highlighting players strengths and weaknesses to enable more stable landing technique. The variables analyzed were the position and velocity of center of gravity(CG) and angles of shoulder joints, hip joints, and trunk. The results are as follows: S1 secured the height of flight with fast vertical rise. After the easy spin in the air, he conducted a stable landing maintaining a proper hip joints angle. S2, S3, and S4, however, began the backward somersault already before leaving the bars, so they moved backward greatly making it more difficult to achieve a higher flight path. As a result, they couldn't control the velocity of their backward movement at landing. For a stable landing, they have to maintain the negative shoulder angle when rising, minimize both antero-posterioror side-to-side movements by doing a strong tap using hip joints, to secure the height of flight before the somersault. Results also show that at the descent, they should conduct rapid spinning by increasing their shoulder and hip joints to the maximum while controlling their velocity.

Calculation of the Least Significant Change Value of Bone Densitometry Using a Dual-Energy X-ray Absorptiometry System

  • Han-Kyung Seo;Do-Cheol Choi;Cheol-Min Shim;Jin-Hyeong Jo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.95-98
    • /
    • 2023
  • Purpose: The precision error of a bone density meter reflects the equipment and reproducibility of results by an examiner. Precision error values can be expressed as coefficient of variation (CV), CV%, and root mean square-SD (RMS-SD). The International Society for Clinical Densitometry (ISCD) currently recommends using RMS-SD as the precision error value. When a 95% confidence interval is applied, the least significant change (LSC) value is calculated by multiplying the precision error value by 2.77. Exceeding the LSC value reflects a significant difference in measured bone density. Therefore, the LSC value of a bone density equipment is an essential factor for accurately determining a patient's bone density. Accordingly, we aimed to calculate the LSC value of a bone density meter (Lunar iDXA, GE) and compare it with the value recommended by the ISCD. We also assessed whether the value measured by the iDXA equipment was below the LSC value recommended by ISCD. Material and Methods: The bone densities of the lumbar spine and thighs of 30 participants were measured twice, and the LSC values were calculated using the precision calculation tool provided by the ISCD (http://www.iscd.org). To check the reproducibility of the measurement, patients were asked to completely dismount from the equipment after the first measurement; the patient was then repositioned before proceeding with the second measurement. Results: The LSC values derived using the CV% values recommended by the ISCD were 5.3% for the lumbar spine and 5.0% for the thigh. The LSC values measured using our bone density equipment were 2.47% for the lumbar spine and 1.61% for the thigh. The LSC value using RMS-SD was 0.031 g/cm2 for the lumbar spine and 0.017 g/cm2 for the thigh. Conclusion: that the findings confirm that the CV% value measured using our bone density meter and the LSC value using RMS-SD were maintained very stably. This can be helpful for obtaining accurate measurements during bone density follow-up examinations.

Agent-based Modeling and Analysis of Tactical Reconnaissance Behavior with Manned and Unmanned Vehicles (에이전트 기반 유·무인 수색정찰 전술행위 모델링 및 분석)

  • Kim, Ju Youn;Han, Sang Woo;Pyun, Jai Jeong
    • Journal of the Korea Society for Simulation
    • /
    • v.27 no.4
    • /
    • pp.47-60
    • /
    • 2018
  • Today's unmanned technology, which is being used in various industries, is expected to be able to make autonomous judgements as autonomous technology matures, in the long run aspects. In order to improve the usability of unmanned system in the military field, it is necessary to develop a technique for systematically and quantitatively analyzing the efficiency and effectiveness of the unmanned system by means of a substitute for the tasks performed by humans. In this paper, we propose the method of representing rule-based tactical behavior and modeling manned and unmanned reconnaissance agents that can effectively analyze the path alternatives which is required for the future armored cavalry to establish a reconnaissance mission plan. First, we model the unmanned ground vehicle, small tactical vehicle, and combatant as an agent concept. Next, we implement the proposed agent behavior rules, e.g., maneuver, detection, route determination, and combatant's dismount point selection, by NetLogo. Considering the conditions of maneuver, enemy threat elements, reconnaissance assets, appropriate routes are automatically selected on the operation area. It is expected that it will be useful in analyzing unmanned ground system effects by calculating reconnaissance conducted area, time, and combat contribution ratio on the route.

Kinematic Analysis of Airborne Movement of Dismount from High Bar(I) (철봉 내리기 공중 동작의 운동학적 분석(I))

  • Choi, Ji-Young;Kim, Youg-Ee;Jin, Young-Wan
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.159-177
    • /
    • 2002
  • The purpose of this study was to investigate the relations between the segments of the body, the three dimensional anatomical angle and the angular velocity of the air born phase and understand the control mechanism of the high-bar movement, the somersault, the double somersault, the double somersault with full twist. For this study seven well trained university gymnastic volunteered, Zatsiorky and Seluyanov(1983, 1985)'s sixteen segment system anatomical model was used for this study. For the movement analysis three dimensional cinematographical method(Arial Performance Analysis System : APAS) was used and for the calculation of the kinematic variables a self developed program was used with the LabVIEW 5.1 graphical profromming(Johnson, 1999) program. By using Eular's equations the three dimensional anatomical Cardan angles of the joint and angular velocity were defined. As a result of this study 1. As the rotation of the body increased in the air born phase the projection angle of the CM of the total increased, this resulted the increased of the max hight of the CM. 2. In three dimensional angular velocity the Z axis(vertical direction) projection angular velocity increased as the rotation of the body increased in the airborn phase, but the Y axis and the X axis projection angular velocity did not show significant differences. 3. As the rotation of the body increased in the air born phase the angular movement of the shoulder and the hip showed significant change. These movement act as the starter in the preparation phase. 4. The somersault angle, the twist angle, the tilt angle of the upper body related to the global reference frame in the releas phase the average somersault angle of the three types of high-bar movement was $57.7^{\circ}$, $38.8^{\circ}$, $39.7^{\circ}$, the average tilt angle was $-1.5^{\circ}$, $-5.4^{\circ}$, $-8.4^{\circ}$, the average twist angle was $13.4^{\circ}$, $10.6^{\circ}$, $23.3^{\circ}$. This result showed that the somersault with full twist had the largest movement.